Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Effect of Apex Flap Deflection on Vertical Tail Buffeting

A computational study of the effect of vortex breakdown location on vertical tail buffeting is conducted. The position of the breakdown is modified by employing an apex flap deflected by an experimentally determined optimal angle. The delayed breakdown flow and buffeting response is then compared to the nominal undeflected case. This multidisciplinary problem is solved sequentially for the fluid flow, the elastic tail deformations and the grid displacements. The fluid flow is simulated by time accurately solving the unsteady, compressible, Reynolds-averaged Navier-Stokes equations using an implicit, upwind, flux-difference splitting finite volume scheme. The elastic vibrations of the tails are modeled by uncoupled bending and torsion beam equations. These equations are solved accurately in time using the Galerkin method and a five-stage Runge-Kutta-Verner scheme. The grid for the fluid dynamics calculations is continuously deformed using interpolation functions to disperse the displacements smoothly throughout the computational domain. An angle-of-attack of 35 deg.is chosen such that the wing primary-vortex cores experience vortex breakdown and the resulting turbulent wake flow impinges on tile vertical tails. The dimensions and material properties of the vertical tails are chosen such that the deflections are large enough to insure interaction with the flow, and the natural frequencies are high enough to facilitate a practical computational solution. Results are presented for a baseline uncontrolled buffeting case and a delayed breakdown case in which the apex flap has been deflected 15 deg. The flap was found to be very effective in delaying the breakdown, increasing the location from 50%c to 94%c, which resulted in a 6% increase in lift coefficient and pitching moment. However, the integrated buffet loads and tip responses were roughly equivalent for the two cases.

Massey, Steven J.↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectrics Under Extreme Electric Fields: In Situ Studies on Nanoscale Mechanisms (Final Technical Report)

The lack of materials that can function reliably under extreme electric fields is a critical roadblock to achieving higher energy efficiency and extended service lifetime of devices in electricity generation, transmission, and consumption. Materials typically fail at two or three orders of magnitude below their theoretical dielectric breakdown strength. Identifying the origins of premature dielectric breakdown using state-of-the-art characterization tools will, therefore, enable the design and discovery of transformational materials capable of approaching their intrinsic limits. The vast improvement in the resolution power of imaging tools, combined with the recently developed in situ electric biasing technique, has made high resolution observations of dielectric breakdown as it happens possible. The overall goal of the project is to directly image the dynamic processes of defect formation, accumulation, and interaction with preexisting defects (e.g., dislocations, domain walls, and grain boundaries in crystalline dielectric films) under electric fields up to 1,000 MV/m with a temporal resolution better than 5 microseconds. Using the newly acquired, custom-made Hysitron PI95 transmission electron microscopy (TEM) specimen holder, in situ TEM observations of breakdown at the sub nanometer resolution will be made on representative dielectric compounds with progressive complexities: the linear dielectric SiO 2 , CuO, and TiO 2 , the ferroelectric BaTiO 3 nanocrystals and nanocubes. Through direct observation of the breakdown event at high spatial and temporal resolutions, the nanoscale mechanisms for the failure of dielectrics under intense electric fields will be identified. The results of the project will be applied to the design and processing of new dielectric materials with higher efficiency, improved reliability, and a prolonged lifetime. Such new dielectrics are urgently needed for modernizing energy infrastructures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-premixed counterflow methane flames in DC/AC/NS electric fields

The response of counterflow diffusion flames to sub-breakdown DC and AC electric fields, as well as their superposition with ns pulse discharge waveforms, is studied in the plane-to-plane electrode geometry. Sub-breakdown DC and low-frequency AC electric fields cause the flame displacement toward the grounded electrode, in the direction of the applied field, indicating that the body force on the positive ions exceeds that on the electrons and negative ions. As the AC frequency increases, the flame response becomes less pronounced, due to the reduction of the electrohydrodynamic (EHD) body force impulse over the AC half-period. The electric field in the electrode gap is determined by ps Electric Field Induced Second Harmonic (E-FISH) generation, with absolute calibration using sub-breakdown ns pulses overlapped with the measured electric field waveform. The results show that the electric field distribution across the flame in the current saturation regime follows the Laplacian field. This indicates that the space charge density in the gap is too low to distort the applied DC or AC field, consistent with the kinetic modeling predictions. Combining a nanosecond pulse discharge with a sub-breakdown DC field generates a diffuse plasma across the entire gap. Time-resolved and spatially resolved measurements of the electric field in the discharge indicate the ionization wave propagation between the electrodes. The present results do not exhibit a detectable flame displacement enhancement by ns discharge pulses combined with a sub-breakdown field, observed previously. Kinetic modeling calculations show that the absence of this effect in the plane-to-plane geometry is due to the rapid plasma self-shielding. This indicates that alternative electrode geometries limiting the self-shielding would be more effective for the plasma / electric field enhanced flameholding and flame stabilization applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Depolymerization of lignin for biological conversion through sulfonation and a chelator-mediated Fenton reaction

The generating value from lignin through depolymerization and biological conversion to valuable fuels, chemicals, or intermediates has great promise but is limited by several factors including lack of cost-effective depolymerization methods, toxicity within the breakdown products, and low bioconversion of the breakdown products. High yield depolymerization of natural lignins requires cleaving carbon-carbon bonds in addition to ether bonds. To address that need, we report that a chelator-mediated Fenton reaction can efficiently cleave C-C bonds in sulfonated polymers at or near room temperature, and that unwanted repolymerization can be minimized through optimizing reaction conditions. This method was used to depolymerize lignosulfonate from M w = 28,000 g/mol to M w = 800 g/mol. The breakdown products were characterized by SEC, FTIR and NMR and evaluated for bioavailability. The breakdown products are rich in acid, aldehyde, and alcohol functionalities but are largely devoid of aromatics and aliphatic dienes. A panel of nine organisms were tested for the ability to grow on the breakdown products. Growth at a low level was observed for several monocultures on the depolymerized LS in absence of glucose. Much stronger growth was observed in the presence of 0.2% glucose and for one organism we demonstrate doubling of melanin production in the presence of depolymerized LS. The results suggest that this chelator-mediated Fenton method is a promising new approach for biological conversion of lignin into higher value chemicals or intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems

This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), was conducted in collaboration with Temple University. The report describes the research activities with Task 1 at ORNL: foam fracturing testing system development and experimental study on foam fracturing, and Task 2 at Temple University: foam testing and foam characterization. Main findings are: 1. A foam fracturing test system has been developed at ORNL, which can be used to perform foam fracturing under pressure up to 6,000 psi. The system monitors foam density during fracturing online and is capable of testing materials in both monotonic and cyclic (up to 50 Hz) injections. 2. Foam fracturing tests were carried out on Charcoal black granite specimens with a blind borehole to the middle length. Two diameters of blind borehole were tested; G2 series: 9.53 mm and G3 series: 4.76 mm. N2-in-water foam was used with AOS as a surfactant. 3. There was a hole-size effect on fracture initiation pressure. The effect is smaller in the case of foam, which was influenced by the high penetrability of gas in foam. Breakdown pressure showed a behavior just as that of fracture pressure; namely an increased value for small hole samples, while the effect in water fracture was more impressive than in foam fracture. 4. Water mass was reduced in foam fracturing within similar range of breakdown pressures. In G2 series, it was decreased from 10.44 g for water fracturing to 5.17 g, representing more than 50% water reduction. Therefore, there is the potential to reduce water use in EGS stimulation through foam fracturing. 5. Use of cyclic injection has the potential to reduce the breakdown pressure and seismicity in EGS application. Experiments using 4-s cycle period found that specimens can be fractured with a low number of cycles. The fatigue pressure was approximately 64 - 77% of monotonic breakdown pressure for water fracturing and 58 - 94% of the breakdown pressure for foam fracturing. 6. A foam stability testing system has been developed that can test foam at 220 Deg C to 2,000 psi. Tested components of candidate foams included two gases: N2 and CO2; 4 surfactants: AOS, SDS, NP-40 and CTAC; 5 stabilizing agents: guar, bentonite clay, borate salt, silica NPs, and GO. 7. N2 and AOS provided the most stable performance over the tested ranges. Furthermore, the AOS foam with stabilizing agents of guar and borate salt (crosslinker) offered the highest half-life of 20 minutes at 200 Deg C and 1,000 psi. 8. Arrhenius equation and modified power law have been demonstrated to fit well the half-time vs. temperature and pressure data, respectively. These relations can be useful to provide the suggestion for future foam stability study. This submission contains the supporting data developed during the project: 1) A final technical report 2) Granite fracturing data in monotonic and cyclic injections with water and N2 foam Foam performance data in various temperatures and pressures, including half-time, is submitted separately.

15 GEOTHERMAL ENERGY↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Vacuum Insulator Flashover Physics LDRD Report

Large, pulsed power and high voltage systems often employ a stack of insulators to separate a vacuum section away from water or oil sections. The size of this insulator stack often drives overall costs and feasibility of these systems. An electric breakdown along the insulator surface is a primary failure mechanism and is especially impactful if it occurs while power is still being delivered downstream. This report describes a set of experimental and modeling investigations into the cause of these breakdowns, especially focusing on the much less well-understood anode-initiated breakdowns that occur during early parts of power delivery. Additionally, new diagnostics for assessing relevant material properties and behavior of insulators are described. These results describe breakdown behavior and evolution at new temporal and spatial fidelities and provide hypotheses and some answers as to how these breakdowns can occur. This new understanding of the roles of different physics phenomena guide modifications and trade-offs in generating newer insulator stack designs that are smaller and/or have higher electrical stress thresholds.

42 ENGINEERING↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Leading edge vortex dynamics on a pitching delta wing

The leading edge flow structure was investigated on a 70 deg flat plate delta wing which was pitched about its 1/2 chord position, to increase understanding of the high angle of attack aerodynamics on an unsteady delta wing. The wing was sinusoidally pitched at reduced frequencies ranging from k being identical with 2pi fc/u = 0.05 to 0.30 at chord Reynolds numbers between 90,000 and 350,000, for angle of attack ranges of alpha = 29 to 39 deg and alpha = 0 to 45 deg. The wing was also impulsively pitched at an approximate rate of 0.7 rad/s. During these dynamic motions, visualization of the leading edge vorticies was obtained by entraining titanium tetrachloride into the flow at the model apex. The location of vortex breakdown was recorded using 16mm high speed motion picture photography. When the wing was sinusoidally pitched, a hysteresis was observed in the location of breakdown position. This hysteresis increased with reduced frequency. The velocity of breakdown propagation along the wing, and the phase lag between model motion and breakdown location were also determined. When the wing was impulsively pitched, several convective times were required for the vortex flow to reach a steady state. Detailed information was also obtained on the oscillation of breakdown position in both static and dynamic cases.

Lemay, Scott P.↗

Avalanche photodiode photon counting receivers for space-borne lidars

Avalanche photodiodes (APD) are studied for uses as photon counting detectors in spaceborne lidars. Non-breakdown APD photon counters, in which the APD's are biased below the breakdown point, are shown to outperform: (1) conventional APD photon counters biased above the breakdown point; (2) conventional APD photon counters biased above the breakdown point; and (3) APD's in analog mode when the received optical signal is extremely weak. Non-breakdown APD photon counters were shown experimentally to achieve an effective photon counting quantum efficiency of 5.0 percent at lambda = 820 nm with a dead time of 15 ns and a dark count rate of 7000/s which agreed with the theoretically predicted values. The interarrival times of the counts followed an exponential distribution and the counting statistics appeared to follow a Poisson distribution with no after pulsing. It is predicted that the effective photon counting quantum efficiency can be improved to 18.7 percent at lambda = 820 nm and 1.46 percent at lambda = 1060 nm with a dead time of a few nanoseconds by using more advanced commercially available electronic components.

Sun, Xiaoli↗

The Fundamental Gain Limitation of High-Rate Gaseous Detectors and Optimum Designs for High-Rate Applications

We have performed a systematic study of the breakdown mechanism of high-rate detectors: MSGC, MGC, MICROMEGAS and GEM, recently chosen or considered as candidates for high-luminosity applications, together with newly elaborated designs such as high-rate wire chambers, thin gap parallel-plate chamber and super-high-rate RPC's. It was found for all these that the maximum breakdown-limited dramatically with incident flux and further decreases in the presence of alpha particles which are typical of the backgrounds in high-energy experiments. It was determined that the key parameter that limits a detector's performance is the effective current density in the avalanche, and that above a certain value breakdowns occur. At these limits the subsequent breakdowns take place by a mechanism which does not seem to have been previously reported in the literature. We present the results of this study together with a qualitative theory of this new type of breakdown and suggestions for optimizing high-rate detectors which we have verified experimentally.

Fonte, Paulo↗

Progress in Navier-Stokes Simulation of Delta Wing Maneuver Aerodynamics

This paper will summarize recent progress in the numerical simulation of high incidence vortical flow about a generic 65 degree sweep delta wing using the three dimensional, time-dependent, Reynolds averaged, Navier-Stokes (RANS) equations. Computations have been carried out at 15 and 30 degrees angle of attack under subsonic turbulent flow conditions, and compared with experimental data provided by Hanff, Jenkins, and their colleagues. This work has already been published elsewhere and widely disseminated. Computations carried out at 15 degrees angle of attack included static roll angles ranging up to 65 degrees, and a large-amplitude (40 degree), high rate (7 Hz), forced roll motion. There was very good agreement between computed and experimental forces and moments, and static surface pressures. There was a significant hysteresis of the dynamic rolling moment due to the high rate of roll motion. At this angle of attack, no vortex breakdown was observed in the computations or experiment. Computations were also carried out at 30 degrees angle of attack, where vortex breakdown was present in both the computations and experiment. There was overall good agreement in the computed and experimental forces and moments. The static rolling moment varied with roll angle in a highly nonlinear manner, and exhibited three stable trim points and two unstable trim points. This behavior was attributed to the presence of vortex breakdown. Two large-amplitude (30 degrees), high-rate (10 Hz) forced roll motions were computed. The dynamics of the vortex breakdown motion was dramatically visualized by tracking the time-dependent motion of particles released near the delta wing apex. This numerical visualization is analogous to experimental smoke flow techniques. In one of the dynamic cases the breakdown was found to move off the wing, convected downwind of the trailing edge, and later reformed near the trailing edge through an instability of the vortex core. A damped free-to-roll motion was also computed by releasing the wing from rest at 40 degrees of roll. The wing went to the same trim point as in the experiment.

Chaderjian, Neal M.↗

Gas Composition Sensing Using Carbon Nanotube Arrays

This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.

Li, Jing↗

On the interaction of a wind turbine wake with a conventionally neutral atmospheric boundary layer

In this work, we investigate the dynamics of wind turbine tip-vortex breakdown in a conventionally neutral atmospheric boundary layer (ABL). To this end, high-resolution data are collected from large-eddy simulations of a wind turbine operating within a neutral ABL and studied by means of proper orthogonal decomposition (POD) and Fourier analysis. The high resolution of the generated data in both space and time allows us to gain insight into the tip-vortex breakdown mechanisms by (i) capturing the energy modes of the coherent structures, (ii) studying their contribution to the tip-vortex breakdown through their power spectra functions and mean kinetic energy (MKE) flux, and (iii) analysing the growth rate of each contributing perturbation frequency along tip vortices. Our analysis shows that under a fully turbulent scenario, the growth rate of perturbations along the tip vortices is largest for low wave numbers, i.e. long-wave perturbations. Additionally, the MKE flux reaches its highest value at two diameters downstream of the rotor plane, a behaviour that can be attributed to the coexistence of multiple interacting POD modes, with the streamwise vortex roller mode being the primary contributor to the total MKE flux budget, contributing approximately . Finally, comparisons with a laminar, uniform flow scenario subject to a single-frequency perturbation highlight the differences between the two ambient flow conditions. In the non-turbulent, uniform flow scenario, the growth rate attains its maximum value at a wave number corresponding to the out-of-phase mutual-inductance mechanism, whereas the MKE flux exhibits local minima and maxima along the wake and at different downstream locations depending on the perturbation frequency. Our analyses suggest that the breakdown of the wind turbine tip vortices under a fully turbulent neutral ABL inflow is due to complex interactions across a range of excitation frequencies, in which the mutual-inductance instability may not be the dominant one.

17 WIND ENERGY↗

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of Coupled Hydraulic Fracturing Simulators Using Laboratory-Scale Experiments

In this work, we aim to verify the predictions of the numerical simulators, which are used for designing field-scale hydraulic stimulation experiments. Although a strong theoretical understanding of this process has been gained over the past few decades, numerical predictions of fracture propagation in low-permeability rocks still remains a challenge. Against this background, we performed controlled laboratory-scale hydraulic fracturing experiments in granite samples, which not only provides high-quality experimental data but also a well-characterized experimental set-up. Using the experimental pressure responses and the final fracture sizes as benchmark, we compared the numerical predictions of two coupled hydraulic fracturing simulators—CSMP and GEOS. Both the simulators reproduced the experimental pressure behavior by implementing the physics of Linear Elastic Fracture Mechanics (LEFM) and lubrication theory within a reasonable degree of accuracy. The simulation results indicate that even in the very low-porosity (1–2 %) and low-permeability (10 -18 m 2 - 10 -19 m 2 ) crystalline rocks, which are usually the target of EGS, fluid-loss into the matrix and unsaturated flow impacts the formation breakdown pressure and the post-breakdown pressure trends. Therefore, underestimation of such parameters in numerical modeling can lead to significant underestimation of breakdown pressure. The simulation results also indicate the importance of implementing wellbore solvers for considering the effect of system compressibility and pressure drop due to friction in the injection line. The varying injection rate as a result of decompression at the instant of fracture initiation affects the fracture size, while the entry friction at the connection between the well and the initial notch may cause an increase in the measured breakdown pressure.

15 GEOTHERMAL ENERGY↗