Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below- threshold ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Effect of reactor radiation on the operation of a neodymium inorganic liquid laser

The radiation parameters of a neodymium liquid laser based on phosphorus oxychloride are measured upon irradiation of the laser medium by neutrons and gamma-rays from a BARS-6 two-zone reactor. This irradiation increases the laser energy by 20%-30% compared to the laser energy in the absence of irradiation. The lasing threshold is observed to decrease with increasing the irradiation dose. In the case of simultaneous optical and nuclear pumping of the laser medium, the free-running regime of laser operation converts to the regime of high-power pulses. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined Photoneutron And X Ray Interrogation Of Containers For Nuclear Materials

Effective cargo inspection systems for nuclear material detection require good penetration by the interrogating radiation, generation of a sufficient number of fissions, and strong and penetrating detection signatures. Inspection systems need also to be sensitive over a wide range of cargo types and densities encountered in daily commerce. Thus they need to be effective with highly hydrogenous cargo, where neutron attenuation is a major limitation, as well as with dense metallic cargo, where x-ray penetration is low. A system that interrogates cargo with both neutrons and x-rays can, in principle, achieve high performance over the widest range of cargos. Moreover, utilizing strong prompt-neutron ({approx}3 per fission) and delayed-gamma ray ({approx}7 per fission) signatures further strengthens the detection sensitivity across all cargo types. The complementary nature of x-rays and neutrons, used as both probing radiation and detection signatures, alleviates the need to employ exceedingly strong sources, which would otherwise be required to achieve adequate performance across all cargo types, if only one type of radiation probe were employed. A system based on the above principles, employing a commercially-available 9 MV linac was developed and designed. Neutrons are produced simultaneously with x-rays by the photonuclear interaction of the x-ray beam with a suitable converter. A total neutron yield on the order of 10{sup 11} n/s is achieved with an average electron beam current of 100 {mu}A. If fissionable material is present, fissions are produced both by the high-energy x-ray beam and by the photoneutrons. Photofission and neutron fission dominate in hydrogenous and metallic cargos, respectively. Neutron-capture gamma rays provide information on the cargo composition. The prompt neutrons resulting from fission are detected by two independent detector systems: by very efficient Differential Die Away Analysis (DDAA) detectors, and by direct detection of neutrons with energies higher than 3 MeV using a recently developed fluorine-based threshold activation detector (TAD). The delayed gamma-ray signals are measured with high efficiency with the same TAD and with additional lower-cost plastic scintillators.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation into the formation of the scrape-off layer density shoulder in JET ITER-like wall L-mode and H-mode plasmas

The low temperature boundary layer plasma (scrape-off layer or SOL) between the hot core and the surrounding vessel determines the level of power loading, erosion and implantation of material surfaces, and thus the viability of tokamak-based fusion as an energy source. Here, this study explores mechanisms affecting the formation of flattened density profiles, so-called 'density shoulders', in the low-field side (LFS) SOL, which modify ion and neutral fluxes to surfaces—and subsequent erosion. There is evidence against local enhancement of ionization inducing shoulder formation. We find that increases in SOL parallel resistivity, Λ div (=[ L || ν ei Ω i ]/ c s Ω e ), postulated to lead to shoulder growth through changes in SOL turbulence characteristics, correlates with increases in SOL shoulder amplitude, A s , but only under a subset of conditions (D 2 -fuelled L-mode density scans with outer strike point on the horizontal target). Λ div fails to correlate with A s for cases of N 2 seeding or during sweeping of the strike point across the horizontal target. The limited correlation of Λ div and A s is also found for H-mode discharges. Thus, while it may be necessary for Λ div to be above a threshold of ~1 for shoulder formation and/or growth, another mechanism is required. More significantly, we find that in contrast to parallel resistivity, outer divertor recycling, as quantified by the total outer divertor Balmer D α emission, I – D α , does scale with A s where Λ div does and even where Λ div does not. Divertor recycling could lead to SOL density shoulder formation through: (a) reducing the parallel to the field flow (loss) of ions out of the SOL to the divertor; and (b) changes in radial electric fields which lead to E × B poloidal flows as well as potentially affecting SOL turbulence birth characteristics. Therefore, changes in divertor recycling may be the sole process involved in bringing about SOL density shoulders or it may be that it acts in tandem with parallel resistivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated size-specific CT dose monitoring program: Assessing variability in CT dose

Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

60 APPLIED LIFE SCIENCES↗

Measurement of low energy ionization signals from Compton scattering in a charge-coupled device dark matter detector [Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector]

In this paper, an important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental γ rays. We report detailed measurements of low-energy spectra from Compton scattering of γ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by γ rays from 57 Co and 241 Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically motivated parametrization of the data that describes the Compton spectrum at low energies for any incident γ-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threshold photoneutron cross sections for {sup 208,207,206}Pb isotopes

Photoneutron cross sections for three Pb isotopes ({sup 206}Pb, {sup 207}Pb, {sup 208}Pb) near neutron threshold were measured with the laser inverse-Compton scattering gamma rays at the National Institute of Advanced Industrial Science and Technology. The cross section data are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultraviolet photodissociation dynamics of the phenyl radical

Ultraviolet (UV) photodissociation dynamics of jet-cooled phenyl radicals (C{sub 6}H{sub 5} and C{sub 6}D{sub 5}) are studied in the photolysis wavelength region of 215-268 nm using high-n Rydberg atom time-of-flight and resonance enhanced multiphoton ionization techniques. The phenyl radicals are produced from 193-nm photolysis of chlorobenzene and bromobenzene precursors. The H-atom photofragment yield spectra have a broad peak centered around 235 nm and are in good agreement with the UV absorption spectra of phenyl. The H + C{sub 6}H{sub 4} product translational energy distributions, P(E{sub T})'s, peak near {approx}7 kcal/mol, and the fraction of average translational energy in the total excess energy, , is in the range of 0.20-0.35 from 215 to 268 nm. The H-atom product angular distribution is isotropic. The dissociation rates are in the range of 10{sup 7}-10{sup 8} s{sup -1} with internal energy from 30 to 46 kcal/mol above the threshold of the lowest energy channel H +o-C{sub 6}H{sub 4} (ortho-benzyne), comparable with the rates from the Rice-Ramsperger-Kassel-Marcus theory. The results from the fully deuterated phenyl radical are identical. The dissociation mechanism is consistent with production of H +o-C{sub 6}H{sub 4}, as the main channel from unimolecular decomposition of the ground electronic state phenyl radical following internal conversion of the electronically excited state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge segregation in weakly ionized microgels

Here we investigate microgels synthesized from N-isopropylacrylamide (NIPAM) copolymerized with a large mol% of acrylic acid, finding that when the acid groups are partially ionized at high temperatures, competition between ion-induced swelling and hydrophobic deswelling of poly(NIPAM) chains results in microphase separation. In cross-linked microgels, this manifests as a dramatic decrease in the ratio between the radius of gyration and the hydrodynamic radius to ~0.2, indicating that almost all the mass of the microgel is concentrated near the particle center. We also observe a concurrent decrease of the polymer network length scale via small-angle neutron scattering, confirming the presence of a dense, deswollen core surrounded by a diffuse, charged periphery. We compare these results to those obtained for a system of charged ultralow-cross-linked microgels; the form factor shows a distinct peak at high q when the temperature exceeds a threshold value. Lastly, we successfully fit the form factor to theory developed to describe scattering from weakly charged gels in poor solvents, and we tie this behavior to charge segregation in the case of the cross-linked microgels.

59 BASIC BIOLOGICAL SCIENCES↗

On the mechanism of formation of excited states of the {sup 8}Be nucleus in the reaction {sup 12}C({gamma}, 3{alpha})

The reaction {sup 12}C({gamma}, 3{alpha}) was studied with the aid of a diffusion chamber placed in a magnetic field, filled with a methane-helium mixture, and irradiated with bremsstrahlung photons of endpoint energy 150 MeV. The total reaction cross section was measured in the energy range E{sub {gamma} }< 40 MeV. The ground state; the first, second, and unseparated third and fourth excited states; and highly excited states (in the range 19.9 < E{sub x} < 25.2 MeV) of the {sup 8}Be nucleus manifested themselves in the distribution of events with respect to the energy of the relative motion of two alpha particles. A resonance that is characterized by the energy of E{sub 0} = 0.72 MeV and the width of {Gamma} = 0.80 MeV and which was identified as a ghost anomaly was found between the ground state and the first excited state. Partial cross sections were measured for various channels. Excited states are formed in narrow photon-energy intervals, and their partial cross sections are of a resonance shape. It is found that the energy corresponding to the maximum of the partial cross section for the ith level, E{sub m}{sup i}, and the excitation energy of the next level, E{sub 0}{sup i+1}, are correlated: E{sub m}{sup i} = E{sub 0}{sup i+1} + {epsilon}, where {epsilon} is the reaction threshold. The results are qualitatively explained on the basis of a model that assumes photon absorption by an alpha-particle pair.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of analog states in the T=1/2 A=27 mirror system from low excitation energies to the region of hydrogen burning in the {sup 26}Al{sup g,m}(p,{gamma}){sup 27}Si reactions

The reactions {sup 26}Al{sup g}(p, {gamma}){sup 27}Si and {sup 26}Al{sup m}(p, {gamma}){sup 27}Si are important for influencing the galactic abundance of the cosmic {gamma}-ray emitter {sup 26}Al{sup g} and for the excess abundance of {sup 26}Mg found in presolar grains, respectively. Precise excitation energies and spin assignments of states from the ground state to the region of astrophysical interest in {sup 27}Si, including the identification and pairing of key astrophysical resonances with analog states in the mirror nucleus {sup 27}Al, are reported using {gamma} rays observed in the {sup 12}C + {sup 16}O fusion reaction. The detailed evolution of Coulomb energy differences between the states in {sup 27}Si and {sup 27}Al is explored, including the region above the astrophysical reaction thresholds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-C-BRE-09: Performance Comparisons of Patient Specific IMRT QA Methodologies Using ROC Analysis

Purpose: To evaluate the ability of a selection of patient-specific QA methods to accurately classify IMRT plans as acceptable or unacceptable based on a multiple ion chamber (MIC) phantom. Methods: Twenty-four IMRT plans were selected (20 previously failed the institutional QA), and were measured on a MIC phantom to assess their dosimetric acceptability. These same plans were then measured using film (Kodak EDR2) and ion chamber (Wellhofer cc04), ArcCheck (Sun Nuclear), and MapCheck (Sun Nuclear) (delivered AP field-by-field, AP composite, and with original gantry angles). All gamma analyses were performed at 2%/2mm, 3%/3mm, and 5%/3mm. By using the MIC results as a gold standard, the sensitivity and specificity were calculated across a range of cut-off thresholds (% pixels passing for gamma analysis, and % dose difference for ion chamber), and were used to form ROC curves. Area under the curve (AUC) was used as a metric to quantify the performance of the various QA methods. Results: Grouping device’s AUC’s revealed two statistically significant different groups: ion chamber (AUC of 0.94), AP composite MapCheck (AUC of 0.85), ArcCheck (AUC of 0.84), and film (AUC of 0.82) were in the better performing group, while original gantry angles and AP field-by-field MapCheck (AUC of 0.65 and 0.66, respectively) matched less well with the gold standard results. Optimal cut-offs were also assessed using the ROC curves. We found that while often 90% of pixels passing is used as a criteria, the differing sensitivities of QA methods can lead to device and methodology-based optimal cutoff thresholds. Conclusion: While many methods exist to perform the same task of patient-specific IMRT QA, they utilize different strategies. This work has shown that there are inconsistencies in these methodologies in terms of their sensitivity and specificity to dosimetric acceptability. This work was supported by Public Health Service grants CA010953, CA081647, and CA21661 awarded by the National Cancer Institute, United States Department of Health and Human Services.

60 APPLIED LIFE SCIENCES↗

Investigation of the spatial resolution of an online dose verification device

Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm{sup 2} slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using {chi}-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the {chi}-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in-field points below {chi} of 1.0 for fields 1 and 2, respectively (with an average {chi} of 0.29 for IMRT field 1 and 0.24 for IMRT field 2). Conclusions: The LSF for a new novel online detector has been measured at 6 MV using a narrow slit technique, and this measurement has been validated by Monte Carlo simulation. The detector response function derived from line spread function has been applied to recover measured IMRT fields. The results have shown that the device measures IMRT fields accurately within acceptable tolerance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mitigation of hot electrons from laser-plasma instabilities in high-Z, highly ionized plasmas

Intense lasers interacting with under-dense plasma can drive laser-plasma instabilities (LPIs) that generate largeamplitude electron plasma waves (EPWs). Suprathermal or “hot” electrons produced in the EPWs are detrimental to inertial confinement fusion (ICF), by reducing capsule implosion efficiency through preheat, and also present an unwanted source of background on x-ray diagnostics. Mitigation of hot electrons was demonstrated in the past by altering plasma conditions near the quarter-critical density, n c /4, with the interpretation of reduced growth of the twoplasmon decay (TPD) instability. Here, we present measurements of hot electrons generated in laser-irradiated planar foils of material ranging from low- to high-Z, where the fraction of laser energy converted to hot electrons, fhot was reduced by a factor of 10 3 going from CH to Au. This correlates with steepening density gradient length-scales that were also measured. Radiation hydrodynamic simulations produced electron density profiles in reasonable agreement with our measurements. According to the simulations, both multi-beam TPD and stimulated Raman scattering were predicted to be above threshold with linear threshold parameters that decreased with increasing Z due to steepening length-scales, as well as enhanced laser absorption and increased EPW collisional and Landau damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherence and quasistable states in a strong infrared field

We study the quasistability of UV-pulse-train-excited H atoms in a strong infrared (IR) laser as a function of the phase delay of the UV pulse train relative to the IR laser. The UV pulse train contains two frequency components. When the two components have frequencies separated by two IR photons, the population of surviving electrons is modulated by up to ten percent. When electrons are excited to right above or below the threshold, the survival probabilities have inverted phase delay dependence, which can be explained classically. When the two frequencies are one IR photon apart, the angular symmetry of the quasistable electrons is broken, and the asymmetry is also controlled by the phase delay. Here, the asymmetrical distribution can be observed while the IR is on and smoothly evolves to a nonzero asymmetry that only weakly depends on the duration of the IR field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Additional {alpha}-particle optical potential tests below the Coulomb barrier

New results of ({alpha},{gamma}) and ({alpha},n) reaction cross section measurements close to the reaction thresholds support the setting up of recent parameters of the {alpha}-particle optical model potential (OMP) below the Coulomb barrier. Particular features of the {alpha}-particle optical potential at energies below the Coulomb barrier explain the failure of using the OMP parameters obtained by analysis of only {alpha}-particle elastic scattering at higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of the IceCube neutrino detector to dark matter annihilating in dwarf galaxies

In this paper, we compare the relative sensitivities of gamma-ray and neutrino observations to the dark matter annihilation cross section in leptophilic models such as have been designed to explain PAMELA data. We investigate whether the high energy neutrino telescope IceCube will be competitive with current and upcoming searches by gamma-ray telescopes, such as the Atmospheric Cerenkov Telescopes (H.E.S.S., VERITAS, and MAGIC), or the Fermi Gamma-Ray Space Telescope, in detecting or constraining dark matter particles annihilating in dwarf spheroidal galaxies. We find that after 10 years of observation of the most promising nearby dwarfs, IceCube will have sensitivity comparable to the current sensitivity of gamma-ray telescopes only for very heavy (m{sub X} > or approx. 7 TeV) or relatively light (m{sub X} < or approx. 200 GeV) dark matter particles which annihilate primarily to {mu}{sup +{mu}-}. If dark matter particles annihilate primarily to {tau}{sup +{tau}-}, IceCube will have superior sensitivity only for dark matter particle masses below the 200 GeV threshold of current Atmospheric Cerenkov Telescopes. If dark matter annihilations proceed directly to neutrino-antineutrino pairs a substantial fraction of the time, IceCube will be competitive with gamma-ray telescopes for a much wider range of dark matter masses. K. F. would like to thank the Aspen Center for Physics and the Texas Cosmology Center, and P. S. would like to thank MCTP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoionization and photofragmentation of the C 60 + molecular ion

Cross-section measurements are reported for single and double photoionization of C$+\atop{60}$ ions in the photon energy range 18-150 eV accompanied by the loss of zero to seven pairs of carbon atoms, as well as for fragmentation without ionization resulting in loss of two to eight pairs of C atoms in the photon energy range 18-65 eV. Absolute measurements were performed by merging a beam of C$+\atop{60}$ molecular ions with a beam of monochromatized synchrotron radiation. Product channels involving dissociation yielding smaller fullerene fragment ions account for nearly half of the total measured oscillator strength in this energy range. The sum of cross sections for the measured product channels is compared to a published calculation of the total photoabsorption cross section of neutral C 60 based on time-dependent density-functional theory. Lastly, this comparison and an accounting of oscillator strengths indicate that with the exception of C$+\atop{58}$, the most important product channels resulting from photoabsorption were accounted for in the experiment. Threshold energies for the successive removal of carbon atom pairs accompanying photoionization are also determined from the measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Metallicity inhomogeneities in local star-forming galaxies as a sign of recent metal-poor gas accretion

We measure the oxygen metallicity of the ionized gas along the major axis of seven dwarf star-forming galaxies. Two of them, SDSSJ1647+21 and SDSSJ2238+14, show ≅0.5 dex metallicity decrements in inner regions with enhanced star formation activity. This behavior is similar to the metallicity drop observed in a number of local tadpole galaxies by Sánchez Almeida et al., and was interpreted as showing early stages of assembling in disk galaxies, with the star formation sustained by external metal-poor gas accretion. The agreement with tadpoles has several implications. (1) It proves that galaxies other than the local tadpoles present the same unusual metallicity pattern. (2) Our metallicity inhomogeneities were inferred using the direct method, thus discarding systematic errors usually attributed to other methods. (3) Taken together with the tadpole data, our findings suggest a threshold around one-tenth the solar value for the metallicity drops to show up. Although galaxies with clear metallicity drops are rare, the physical mechanism responsible for them may sustain a significant part of the star formation activity in the local universe. We argue that the star formation dependence of the mass-metallicity relationship, as well as other general properties followed by most local disk galaxies, is naturally interpreted as side effects of pristine gas infall. Alternatives to the metal-poor gas accretion are examined as well.

79 ASTRONOMY AND ASTROPHYSICS↗