At least 775 records · Page 43

Elucidation of Local Ordering and Atomic-Scale Structure in Polymer-Derived SiOC

Silicon oxycarbide (SiOC) is a versatile ceramic material with tunable microstructure and compositions that can be modulated through precursor chemistry and processing conditions. Though there are several noteworthy uses of SiOC across a range of application spaces, the difficulties in elucidating the short- to medium-range order within these materials have limited the maturation of strategies to precisely control SiC x O 4–x compositions for user-tailored applications. In this contribution, we implement a range of synchrotron scattering and spectroscopy methods coupled with stochastic modeling techniques to elucidate changes in local chemistry and structure associated with the pyrolysis of a commercially available SiOC polymer precursor. Stochastic modeling approaches provide valuable insights into decoupling local Si–O and Si–C environments while confirming predominate heterogeneous phases in materials. Using pyrolysis temperatures between 250 to 800 °C results in a heterogeneous material predominately composed of SiOC and amorphous SiO 2 domains. At 1100 °C, redistribution of Si–C pairs in the SiOC network and Si–O from the SiO 2 domains create a more ordered SiOC phase with local cubic SiC-like ordering. In addition, residual carbon leads to a detectable carbon phases at 1100 °C that persist at higher temperatures. These efforts address the difficulties of obtaining atomic-scale insights into the local structure and nanoscale heterogeneities in SiOC, providing pathways toward establishing structure–property relationships for future materials development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the electron-ion collider

We analyze beam-induced depolarizing effects in the hydrogen jet target (HJET) at the relativistic heavy ion collider (RHIC), which has been used for absolute hadron beam polarimetry and shall be employed at the electron-ion collider (EIC). The EIC’s higher bunch repetition frequencies and shorter bunch durations shift beam harmonics to frequencies that can resonantly drive hyperfine transitions in hydrogen, threatening to depolarize the target atoms. Using frequency-domain analysis of beam harmonics and hyperfine transition frequencies, we establish a photon emission threshold above which beam-induced fields are too weak to cause significant depolarization. For EIC injection (23.5 GeV) and flattop (275 GeV), beam-induced depolarization through the bunch structure renders operation at the current RHIC magnetic guide field at the target (𝐵 0 =120⁢ mT) untenable. Increasing the magnetic guide field at the target to 𝐵 0 ≈ 400⁢ mT moves all hyperfine transition frequencies to at least 3 times the cutoff frequency, ensuring reliable absolute beam polarimetry with the required 1% precision at the EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A static quantum embedding scheme based on coupled cluster theory

Here, we develop a static quantum embedding scheme that utilizes different levels of approximations to coupled cluster (CC) theory for an active fragment region and its environment. To reduce the computational cost, we solve the local fragment problem using a high-level CC method and address the environment problem with a lower-level Møller–Plesset (MP) perturbative method. This embedding approach inherits many conceptual developments from the hybrid second-order Møller–Plesset (MP2) and CC works by Nooijen [J. Chem. Phys. 111, 10815 (1999)] and Bochevarov and Sherrill [J. Chem. Phys. 122, 234110 (2005)]. We go beyond those works here by primarily targeting a specific localized fragment of a molecule and also introducing an alternative mechanism to relax the environment within this framework. We will call this approach MP-CC. We demonstrate the effectiveness of MP-CC on several potential energy curves and a set of thermochemical reaction energies, using CC with singles and doubles as the fragment solver, and MP2-like treatments of the environment. The results are substantially improved by the inclusion of orbital relaxation in the environment. Using localized bonds as the active fragment, we also report results for N=N bond breaking in azomethane and for the central C–C bond torsion in butadiene. We find that when the fragment Hilbert space size remains fixed (e.g., when determined by an intrinsic atomic orbital approach), the method achieves comparable accuracy with both a small and a large basis set. Additionally, our results indicate that increasing the fragment Hilbert space size systematically enhances the accuracy of observables, approaching the precision of the full CC solver.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Terrestrial density of strongly-coupled relics

The simplest cosmologies motivate the consideration of dark matter subcomponents that interact significantly with normal matter. Moreover, such strongly coupled relics may have evaded detection to date if upon encountering the Earth they rapidly thermalize down to terrestrial temperatures, T ⊕ ∼ 300 K ∼ 25 meV , well below the thresholds of most existing dark matter detectors. This shedding of kinetic energy implies a drastic enhancement to the local density, motivating the consideration of alternative detection techniques sensitive to a large density of slowly moving dark matter particles. In this work, we provide a rigorous semianalytic derivation of the terrestrial overdensities of strongly coupled relics, with a particular focus on millicharged particles (MCPs). We go beyond previous studies by incorporating improved estimates of the MCP-atomic scattering cross section, new contributions to the terrestrial density of sub-GeV relics that are independent of the Earth’s gravitational field, and local modifications that can arise due to the cryogenic environments of precision sensors. We also generalize our analysis in order to estimate the terrestrial density of thermalized MCPs that are produced from the collisions of high-energy cosmic rays and become bound by the Earth’s electric field. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Production of microchannel plates using nano-scale additive manufacturing

Microchannel plate (MCP) detectors have been the workhorse detector for many applications, including space borne ultra-violet imaging and spectrographic instruments. Recent advances in additive manufacturing (AM) have enabled fabrication of complex structures with nano-scale resolution facilitating the production of highly customizable MCPs. Using AM to produce MCPs potentially has many advantages over traditional fused glass substrates, including better material control (e.g., more robust glasses or ceramics), better control of microscopic features (e.g., unique pore geometries to improve performance), and better control of macroscopic features (e.g., printing precision curved surfaces for focal plane matching). Through a collaboration with industry, national laboratory, and university partners, small format microcapillary array substrates were produced using a standard polymer photoresin. In conclusion, these substrates were functionalized using atomic layer deposition and their performance was compared to current state-of-the-art Pb-glass and borosilicate-glass MCPs.

36 MATERIALS SCIENCE↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

Fabrication of nanoporous doped metal oxide coatings via selective infiltration of a block copolymer template: The case of Al-doped zinc oxide

Conductive nanoporous conformal coatings are important for various applications including touchscreens, displays, and electrochromic windows, though design of such coating with controlled porosity and composition remains challenging. We propose a sequential infiltration synthesis (SIS) method for the fabrication of nanoporous conductive aluminum-doped zinc oxide (AZO) films by infiltrating block copolymer (BCP) templates, specifically polystyrene-block-polyvinyl pyridine (PS-b-P4VP), with diethyl zinc and trimethyl aluminum precursors. Tunability of both porosity and electrical conductivity is achieved by precisely controlling the swelling behavior of the polymer templates and adjusting the number of SIS cycles. Further, our results reveal that porosity levels can reach up to 80 %, with resistivity as low as ~7.83 Ωcm. Using conductive atomic force microscopy (C-AFM) and Hall effect measurements, we show that lower concentrations of aluminum doping relative to zinc (around 1: 17) results in higher conductivity of the AZO films. Additionally, AZO is based on zinc oxide (ZnO) which is cost-efficient, abundant and less toxic than commonly used transparent conductive oxides such as indium tin oxide (ITO) and fluorine-doped tin oxide (FTO). Therefore, this novel approach opens new possibilities for creating highly porous, conformal, conductive AZO coatings with customizable porosity and composition, making them ideal candidates for diverse optoelectronic applications.

36 MATERIALS SCIENCE↗

Frequency reproducibility of solid-state thorium-229 nuclear clocks

Solid-state thorium-229 ( 229 Th) nuclear clocks are set to provide new opportunities for precision metrology and fundamental physics. Taking advantage of inherent low sensitivity of a nuclear transition to its environment, orders of magnitude more emitters can be hosted in a solid-state crystal compared with current optical lattice atomic clocks. Furthermore, solid-state systems needing only simple thermal control are key to the development of field-deployable compact clocks. Here we explore and characterize the frequency reproducibility of the 229 Th:CaF 2 nuclear clock transition, a key performance metric for all clocks. We measure the transition linewidth and centre frequency as a function of the doping concentration, temperature and time. We report the concentration-dependent inhomogeneous linewidth of the nuclear transition, limited by the intrinsic host crystal properties. We determine an optimal working temperature for the 229 Th:CaF 2 nuclear clock at 196(5) K, at which the first-order thermal sensitivity vanishes. This would enable in situ temperature co-sensing using different quadrupole-split lines, reducing the temperature-induced systematic shift below the 10 −18 fractional frequency uncertainty level. At 195 K, the reproducibility of the nuclear transition frequency is 220 Hz (fractionally 1.1 × 10 −13 ) for two differently doped 229 Th:CaF 2 crystals over 7 months. Furthermore, these results form the foundation for understanding, controlling and harnessing the coherent nuclear excitation of 229 Th in solid-state hosts and for their applications in constraining temporal variations of fundamental constants.

Atomic and molecular physics↗

Ultrafast x-ray imaging of coherently controlled molecular dynamics in real space and time

Coherent control aims to manipulate chemical processes on the latent length and timescales of atoms and bonds, scales that are intrinsic to molecular dynamics but not directly resolved by most experimental probes. As a result, existing coherent-control experiments, which overwhelmingly rely on spectroscopic observables, leave a crucial blind spot: the direct, real-space recovery of all atomic and molecular rearrangements in response to coherently controlled excitations. Here, we overcome this limitation by integrating a Tannor-Kosloff-Rice pump-control-probe scheme with ultrafast X-ray scattering to capture snapshots of the wavepacket motion in a benchmark molecular system. We demonstrate this by photoexciting diatomic iodine vapor with a visible pump pulse, selectively steering the wavepacket toward ground-state recombination or dissociative pathways with a time-delayed near-IR control pulse, and recording the dynamics with angstrom and femtosecond precision with an ultrashort hard X-ray probe pulse. By comparing these structural observations with numerical solutions of the time-dependent Schrödinger equation, we reveal how coherent control actively reshapes the molecular charge density distribution. Our results pave the way for leveraging structural feedback as a control handle and provide a fundamental microscopic visualization of quantum decoherence and energy redistribution at the atomic level.

Hopper, Thomas R. [SLAC National Accelerator Labor↗

Spin–orbit coupling of electrons on separate lanthanide atoms of Pr 2 O 2 and its singly charged cation

Although it plays a critical role in the photophysics and catalysis of lanthanides, spin–orbit coupling of electrons on individual lanthanide atoms in small clusters is not well understood. The major objective of this work is to probe such coupling of the praseodymium (Pr) 4f and 6s electrons in Pr 2 O 2 and Pr 2 O 2 +. The approach combines mass-analyzed threshold ionization spectroscopy and spin–orbit multiconfiguration second-order quasi-degenerate perturbation theory. The energies of six ionization transitions are precisely measured; the adiabatic ionization energy of the neutral cluster is 38 045 (5) cm –1 . Most of the electronic states involved in these transitions are identified as spin–orbit coupled states consisting of two or more electron spins. The electron configurations of these states are 4f 4 6s 2 for the neutral cluster and 4 f 46 s for the singly charged cation, both in planar rhombus-type structures. Finally, the spin–orbit splitting due to the coupling of the electrons on the separate Pr atoms is on the order of hundreds of wavenumbers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A practical approach to calculating magnetic Johnson noise for precision measurements

Magnetic Johnson noise is an important consideration for many applications involving precision magnetometry, and its significance will only increase in the future with improvements in measurement sensitivity. The fluctuation–dissipation theorem can be utilized to derive analytic expressions for magnetic Johnson noise in certain situations, but when used in conjunction with finite element analysis tools, the combined approach is particularly powerful as it provides a practical means to calculate the magnetic Johnson noise arising from conductors of arbitrary geometry and permeability. In this paper, we demonstrate this method to be one of the most comprehensive approaches presently available to calculate thermal magnetic noise. In particular, its applicability is shown to not be limited to cases where the noise is evaluated at a point in space but also can be expanded to include cases where the magnetic field detector has a more general shape, such as a finite-size loop, a gradiometer, or a detector that consists of a polarized atomic species trapped in a volume. Furthermore, some physics insights gained through studies made using this method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chemical structure and complex growth modes of magnesium silicate hydrate: Nanoparticle orientation, aggregation, and fusion

The extent of utilization of magnesium silicate hydrate (MSH) in construction is limited partly because of insufficient data ascertaining the kinetics of its precipitation. In this report MSH grown homogeneously or heterogeneously in the range of magnesium to silicon solution molar concentration ratios, [Mg]/[Si] = 0.5-1.5, and temperature = 25-80 °C was analyzed for its chemical structure and morphology. Infrared spectroscopy and geochemical modeling show that increasing the [Mg]/[Si] ratio results in less silicate polymerization in MSH. Atomic force microscopy reveals the presence of nanoparticles that aggregate and fuse to form films. Oriented attachment of nanoparticles and features indicative of enhanced crystallinity were observed at higher temperatures and longer reaction times. These data provide direct evidence for the persistence of hierarchical structures (i.e., nanoparticles forming 3D microparticles and 2D film layers) at the nanoscale to mesoscale. These findings offer insights into the precise chemical synthesis of MSH and its widespread use as a binder for construction purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar data uncertainty impacts on MCMC methods for r-process nucleosynthesis

In recent work, we developed a Markov Chain Monte Carlo (MCMC) procedure to predict the ground state masses capable of forming the observed Solar r-process rare-earth abundance peak. By applying this method to nucleosynthesis calculations which make use of distinct astrophysical conditions and comparing our results to the latest precision mass measurements, we are able to shed light on the conditions/masses capable of producing a rare-earth peak which matches Solar data. Here we examine how our mass predictions change when using a few different sets of r-process Solar abundance residuals that have been reported in the literature. We explore how the differing error estimates of these Solar evaluations propagate through the Markov Chain Monte Carlo to our mass predictions. We find that Solar data which reports the rare-earth peak to have its highest abundance at mass number A = 162 can require distinctly different mass predictions from data with the peak centered at A = 164. Nevertheless, we find that two important general conclusions from past work, regarding the inconsistency of ‘cold’ astrophysical outflows with current mass measurements and the need for local stability at N = 104 in ‘hot’ scenarios, remain robust in the face of differing Solar data evaluations. Additionally, we show that the masses our procedure finds capable of producing a peak at A < 164 are not in line with the latest precision mass measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Measurement of the Be 7 L / K Capture Ratio in Ta-Based Superconducting Tunnel Junctions

We report a high-statistics measurement of the L / K orbital electron capture ratio in 7 Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction radiation detector that was used to identify the signals from different decay channels. The measured L/K capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. Furthermore, this is the first experiment that uses superconducting tunnel junctions for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

6 ≤ A ≤ 19↗

Measurement Error and Resolution in Quantitative Stable Isotope Probing: Implications for Experimental Design

Quantitative stable isotope probing (qSIP) estimates isotope tracer incorporation into DNA of individual microbes and can link microbial biodiversity and biogeochemistry in complex communities. As with any quantitative estimation technique, qSIP involves measurement error, and a fuller understanding of error, precision, and statistical power benefits qSIP experimental design and data interpretation. We used several qSIP data sets—from soil and seawater microbiomes—to evaluate how variance in isotope incorporation estimates depends on organism abundance and resolution of the density fractionation scheme. We assessed statistical power for replicated qSIP studies, plus sensitivity and specificity for unreplicated designs. As a taxon’s abundance increases, the variance of its weighted mean density declines. Nine fractions appear to be a reasonable trade-off between cost and precision for most qSIP applications. Increasing the number of density fractions beyond that reduces variance, although the magnitude of this benefit declines with additional fractions. Our analysis suggests that, if a taxon has an isotope enrichment of 10 atom% excess, there is a 60% chance that this will be detected as significantly different from zero (with alpha 0.1). With five replicates, isotope enrichment of 5 atom% could be detected with power (0.6) and alpha (0.1). Finally, we illustrate the importance of internal standards, which can help to calibrate per sample conversions of %GC to mean weighted density. These results should benefit researchers designing future SIP experiments and provide a useful reference for metagenomic SIP applications where both financial and computational limitations constrain experimental scope.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of wafer scale MoS 2 atomic layers grown by metal–organic chemical vapor deposition using organo-metal, organo-sulfide, and H 2 S precursors

Transition Metal Dichalcogenides (TMDs) are a unique class of materials that exhibit attractive electrical and optical properties which have generated significant interest for applications in microelectronics, optoelectronics, energy storage, and sensing. Considering the potential of these materials to impact such applications, it is crucial to develop a reliable and scalable synthesis process that is compatible with modern industrial manufacturing methods. Metal–organic chemical vapor deposition (MOCVD) offers an ideal solution to produce TMDs, due to its compatibility with large-scale production, precise layer control, and high material purity. Optimization of MOCVD protocols is necessary for effective TMD synthesis and integration into mainstream technologies. Additionally, improvements in metrology are necessary to measure the quality of the fabricated samples more accurately. In this work, we study MOCVD of wafer-scale molybdenum disulfide (MoS 2 ) utilizing two common chalcogen precursors, H 2 S and DTBS. We then develop a metrology platform for wafer scale samples quality assessment. For this, the coalesced films were characterized using Raman spectroscopy, atomic force microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Kelvin probe force microscopy. We then correlate the structural analysis of these grown films with electrical performance by using aerosol jet printing to fabricate van der Pauw test structures and assess sheet resistance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗