Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Spitzer Operations: Scheduling the Out Years

Spitzer Warm Mission operations have remained robust and exceptionally efficient since the cryogenic mission ended in mid-2009. The distance to the now exceeds 1 AU, making telecommunications increasingly difficult; however, analysis has shown that two-way communication could be maintained through at least 2017 with minimal loss in observing efficiency. The science program continues to emphasize the characterization of exoplanets, time domain studies, and deep surveys, all of which can impose interesting scheduling constraints. Recent changes have significantly improved on-board data compression, which both enables certain high volume observations and reduces Spitzer's demand for competitive Deep Space Network resources.

Spitzer↗

Development and Capabilities of ISS Flow Boiling and Condensation Experiment

An experimental facility to perform flow boiling and condensation experiments in long duration microgravity environment is being designed for operation on the International Space Station (ISS). This work describes the design of the subsystems of the FBCE including the Fluid subsystem modules, data acquisition, controls, and diagnostics. Subsystems and components are designed within the constraints of the ISS Fluid Integrated Rack in terms of power availability, cooling capability, mass and volume, and most importantly the safety requirements. In this work we present the results of ground-based performance testing of the FBCE subsystem modules and test module which consist of the two condensation modules and the flow boiling module. During this testing, we evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, heat loss from different modules and components, and performance of the test modules. These results will be used in the refinement of the flight system design and build-up of the FBCE which is manifested for flight in late 2017-early 2018.

microgravity↗

Apollo Experience Report: Crew Station Integration. Volume 5: Lighting Considerations

The lighting requirements for the Apollo spacecraft are presented. The natural lighting factors are discussed in terms of major constraints. A general description of the external and internal lighting systems for the command and lunar modules is presented with a discussion of the primary approach and design criteria followed during development. Some of the more difficult problems encountered during the implementation of a new lighting system are reviewed.

Wheelwright, C. D.↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

SU-E-T-370: Evaluating Plan Quality and Dose Delivery Accuracy of Tomotherapy SBRT Treatments for Lung Cancer

Purpose: This study evaluated the plan quality and dose delivery accuracy of stereotactic body radiotherapy (SBRT) helical Tomotherapy (HT) treatments for lung cancer. Results were compared with those previously reported by our group for flattening filter (FF) and flattening filter free (FFF) VMAT treatments. This work forms part of an ongoing multicentre and multisystem planning and dosimetry audit on FFF beams for lung SBRT. Methods: CT datasets and DICOM RT structures delineating the target volume and organs at risk for 6 lung cancer patients were selected. Treatment plans were generated using the HT treatment planning system. Tumour locations were classified as near rib, near bronchial tree or in free lung with prescribed doses of 48Gy/4fr, 50Gy/5fr and 54Gy/3fr respectively. Dose constraints were specified by a modified RTOG0915 protocol used for an Australian SBRT phase II trial. Plan quality was evaluated using mean PTV dose, PTV volume receiving 100% of the prescribed dose (V100%), target conformity (CI=VD100%/VPTV) and low dose spillage (LDS=VD50%/VPTV). Planned dose distributions were compared to those measured using an ArcCheck phantom. Delivery accuracy was evaluated using a gamma-index pass rate of 95% with 3% (of max dose) and 3mm criteria. Results: Treatment plans for all patients were clinically acceptable in terms of quality and accuracy of dose delivery. The following DVH metrics are reported as averages (SD) of all plans investigated: mean PTV dose was 115.3(2.4)% of prescription, V100% was 98.8(0.9)%, CI was 1.14(0.03) and LDS was 5.02(0.37). The plans had an average gamma-index passing rate of 99.3(1.3)%. Conclusion: The results reported in this study for HT agree within 1 SD to those previously published by our group for VMAT FF and FFF lung SBRT treatments. This suggests that HT delivers lung SBRT treatments of comparable quality and delivery accuracy as VMAT using both FF and FFF beams.

60 APPLIED LIFE SCIENCES↗

SU-E-T-622: Identification and Improvement of Patients Eligible for Dose Escalation with Matched Plans

Purpose: Radiation-therapy dose-escalation beyond 80Gy may improve tumor control rates for patients with localized prostate cancer. Since toxicity remains a concern, treatment planners must achieve dose-escalation while still adhering to dose-constraints for surrounding structures. Patientmatching is a machine-learning technique that identifies prior patients that dosimetrically match DVH parameters of target volumes and critical structures prior to actual treatment planning. We evaluated the feasibility of patient-matching in (1)identifying candidates for safe dose-escalation; and (2)improving DVH parameters for critical structures in actual dose-escalated plans. Methods: We analyzed DVH parameters from 319 historical treatment plans to determine which plans could achieve dose-escalation (8640cGy) without exceeding Zelefsky dose-constraints (rectal and bladder V47Gy<53%, and V75.6Gy<30%, max-point dose to rectum of 8550cGy, max dose to PTV< 9504cGy). We then estimated the percentage of cases that could achieve safe dose-escalation using software that enables patient matching (QuickMatch, Siris Medical, Mountain View, CA). We then replanned a case that had violated DVH constraints with DVH parameters from patient matching, in order to determine whether this previously unacceptable plan could be made eligible with this automated technique. Results: Patient-matching improved the percentage of patients eligible for dose-escalation from 40% to 63% (p=4.7e-4, t-test). Using a commercial optimizer augmented with patient-matching, we demonstrated a case where patient-matching improved the toxicity-profile such that dose-escalation would have been possible; this plan was rapidly achieved using patientmatching software. In this patient, all lower-dose constraints were met with both the denovo and patient-matching plan. In the patient-matching plan, maximum dose to the rectum was 8385cGy, while the denovo plan failed to meet the maximum rectal constraint at 8571cGy. Conclusion: Patientmatching is a promising method to identify eligible patients, and to assist in creating acceptable plans for dose-escalation. Further study will investigate other disease states. Additionally, the time-savings provided by patientmatching warrants further investigation. The following authors have equity ownership in Siris Medical, Inc: K Bush, TF Atwood.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Direct Geologic Constraints on the Timing of Late Holocene Ice Thickening in the Amundsen Sea Embayment, Antarctica

Abstract Constraining past West Antarctic Ice Sheet (WAIS) change helps validate numerical models simulating future ice sheet dynamics. Following rapid deglaciation during the mid‐Holocene, ice near Thwaites Glacier was ∼35 m thinner than present; however, the timing of ice regrowth to its present configuration remains unknown. To fill this knowledge gap, we present cosmogenic nuclide exposure ages of cobbles from the surface of a moraine situated between Thwaites and Pope glaciers. We infer that the moraine formed and stabilized in the Late Holocene (∼1.4 ka) when a small glacier thickened. We also present a novel reconstruction of WAIS volume constrained by sea‐level data, which demonstrates that moraine formation coincided with a large‐scale WAIS readvance. Our new geologic constraints will help inform models of the solid Earth response to surface mass loading, improving our understanding of ice sheet dynamics in a vulnerable part of WAIS.

Nichols, Keir A. [Imperial College London London U↗

Earth-Independent Medical Operations (EIMO) Concept of Operations

Compared to the current paradigm for crew health in low-Earth orbit and Lunar missions that rely on constant communication with Mission Control, there is an anticipated shift in medical operations for deep-space exploration missions. This shift stems from mission constraints imposed by the considerable distance from Earth, which include resource limitations due to a lack of resupply, mass, power, volume, and data limitations, challenges imposed by communication latency and the inability to evacuate in case of emergencies. To transition towards a more self-reliant medical approach, a comprehensive strategy is essential to progressively enable crew autonomy and mitigate mission success risks in the challenging environment of space. This transformative shift is collectively referred to as "Earth-Independent Medical Operations" (EIMO), signifying the gradual transfer of medical care and decision-making from terrestrial resources to space-based assets. This transition is aimed at bolstering astronaut health and performance while simultaneously reducing the overall risks associated with space missions. The constraints related to EIMO necessitate an integrated development of medical systems, featuring interoperability with mission planning, vehicle design, spacesuit design, and data architecture. This integration is vital in establishing a robust medical infrastructure that not only supports the well-being of astronauts but also ensures the success of the mission as a whole. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has developed a model-based Concept of Operations (ConOps) outlining an initial vision for EIMO. Within this ConOps, a comprehensive view is presented, encompassing stakeholder needs, system objectives, and system goals associated with EIMO. Additionally, it provides illustrative examples of the various activities (scenarios) for which the system will be employed during missions. The selection of these activities has been meticulous, aiming to encompass a wide spectrum of medical conditions, including those falling under different risk categories, such as low-likelihood-low-consequence, low-likelihood-high-consequence, and high-likelihood-low-consequence. The selection of these activities (scenarios) effectively encompasses the wide range of medical events situated within an assumed probability-consequence bell curve. In each scenario, at least one of the five main EIMO components identified is captured. Those EIMO components are: Pre-mission Planning, Acute and Emergent Management Decision Making, Prolonged Medical Management Decision Making, Supplies and Resource Management, and Task Load Management. The ConOps was developed by a multidisciplinary team consisting of systems engineers, scientists, and clinicians across NASA and aims to serve as an initial recommendation to gradually and safely enabling crew autonomy for Mars missions and beyond.

Earth Independent Medical Operations↗

Earth-Independent Medical Operations (EIMO) Concept of Operations (ConOps)

Compared to the current paradigm for crew health in low-Earth orbit and Lunar missions that rely on constant communication with Mission Control, there is an anticipated shift in medical operations for deep-space exploration missions. This shift stems from mission constraints imposed by the considerable distance from Earth, which include resource limitations due to a lack of resupply, mass, power, volume, and data limitations, challenges imposed by communication latency and the inability to evacuate in case of emergencies. To transition towards a more self-reliant medical approach, a comprehensive strategy is essential to progressively enable crew autonomy and mitigate mission success risks in the challenging environment of space. This transformative shift is collectively referred to as "Earth-Independent Medical Operations" (EIMO), signifying the gradual transfer of medical care and decision-making from terrestrial resources to space-based assets. This transition is aimed at bolstering astronaut health and performance while simultaneously reducing the overall risks associated with space missions. The constraints related to EIMO necessitate an integrated development of medical systems, featuring interoperability with mission planning, vehicle design, spacesuit design, and data architecture. This integration is vital in establishing a robust medical infrastructure that not only supports the well-being of astronauts but also ensures the success of the mission as a whole. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has developed a model-based Concept of Operations (ConOps) outlining an initial vision for EIMO. Within this ConOps, a comprehensive view is presented, encompassing stakeholder needs, system objectives, and system goals associated with EIMO. Additionally, it provides illustrative examples of the various activities (scenarios) for which the system will be employed during missions. The selection of these activities has been meticulous, aiming to encompass a wide spectrum of medical conditions, including those falling under different risk categories, such as low-likelihood-low-consequence, low-likelihood-high-consequence, and high-likelihood-low-consequence. The selection of these activities (scenarios) effectively encompasses the wide range of medical events situated within an assumed probability-consequence bell curve. In each scenario, at least one of the five main EIMO components identified is captured. Those EIMO components are: Pre-mission Planning, Acute and Emergent Management Decision Making, Prolonged Medical Management Decision Making, Supplies and Resource Management, and Task Load Management. The ConOps was developed by a multidisciplinary team consisting of systems engineers, scientists, and clinicians across NASA and aims to serve as an initial recommendation to gradually and safely enabling crew autonomy for Mars missions and beyond.

Earth Independent Medical Operations↗

Tolerance of the Spinal Cord to Stereotactic Radiosurgery: Insights From Hemangioblastomas

Purpose: To evaluate spinal cord dose-volume effects, we present a retrospective review of stereotactic radiosurgery (SRS) treatments for spinal cord hemangioblastomas. Methods and Materials: From November 2001 to July 2008, 27 spinal hemangioblastomas were treated in 19 patients with SRS. Seventeen tumors received a single fraction with a median dose of 20 Gy (range, 18-30 Gy). Ten lesions were treated using 18-25 Gy in two to three sessions. Cord volumes receiving 8, 10, 12, 14, 16, 18, 20, 22, and 24 Gy and dose to 10, 100, 250, 500, 1000, and 2000 mm{sup 3} of cord were determined. Multisession treatments were converted to single-fraction biologically effective dose (SFBED). Results: Single-fraction median cord D{sub max} was 22.7 Gy (range, 17.8-30.9 Gy). Median V10 was 454 mm{sup 3} (range, 226-3543 mm{sup 3}). Median dose to 500 mm{sup 3} cord was 9.5 Gy (range, 5.3-22.5 Gy). Fractionated median SFBED{sub 3} cord D{sub max} was 14.1 Gy{sub 3} (range, 12.3-19.4 Gy{sub 3}). Potential toxicities included a Grade 2 unilateral foot drop 5 months after SRS and 2 cases of Grade 1 sensory deficits. The actuarial 3-year local tumor control estimate was 86%. Conclusions: Despite exceeding commonly cited spinal cord dose constraints, SRS for spinal hemangioblastomas is safe and effective. Consistent with animal experiments, these data support a partial-volume tolerance model for the human spinal cord. Because irradiated cord volumes were generally small, application of these data to other clinical scenarios should be made cautiously. Further prospective studies of spinal radiosurgery are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Federation Challenges in Remote Near-Real-Time Fusion Experiment Data Processing

Fusion energy experiments and simulations provide critical information needed to plan future fusion reactors. As next-generation devices like ITER move toward long-pulse experiments, analyses, including AI and ML, should be performed in a wide range of time and computing constraints, from near-real-time constraints, between-shot analysis, and to campaign-wide long-term analysis. However, the data volume, velocity, and variety make it extremely challenging for analyses using only local computational resources. Researchers need the ability to compose and execute workflows spanning edge resources to large-scale high-performance computing facilities.We present Delta, a system to address data analysis challenges, including AI/ML, in fusion science, by leveraging the ADIOS I/O library and middleware, to support executing science workflows over the wide area network for near-real-time streaming. We discuss the data federation challenges in performing remote workflows, focusing on on-going research work in (1) managing, reducing, and streaming data to minimize I/O and data movement overheads, (2) decompressing and reorganizing data for analysis, and (3) executing workflows for automated data analysis. We introduce examples for deep-learning based data analysis for the fusion domain and demonstrate how we use Delta to construct end-to-end workflows for a fusion device in Korea, connecting a remote DOE facility in the USA. The capability demonstrated by this project is the basis for improving the state of the art for near-real-time data federation amongst remote facilities.

Choi, Jong Youl↗

RapidArc Planning and Delivery in Patients With Locally Advanced Head-and-Neck Cancer Undergoing Chemoradiotherapy

Purpose: Volumetric modulated arc therapy (RapidArc, Varian Medical Systems) permits the delivery of highly conformal dose distributions. We studied planning and delivery in patients who underwent RapidArc for locally advanced head-and-neck cancer (HNC). Methods and Materials: A total of 35 consecutive patients who completed RapidArc with concurrent chemotherapy for Stages III-IV tumors of the oro- and hypopharynx/larynx in our center were identified. All underwent bilateral neck irradiation and 21 patients had at least N2 disease. A simultaneous integrated boost (SIB) delivered 70 Gy (in 2 Gy/fraction) to the planning target volume (PTV){sub boost} and elective nodal regions (PTV{sub elect}) received 57.75 Gy. A standard planning constraint set was used and constraints for parotid glands were individually adapted. Treatments were delivered using two arcs after all plans were verified in a solid water phantom using GafChromic External Beam Therapy films. Results: RapidArc planning generally took 1.5-2 h, which was faster than with our previous seven-field intensity-modulated radiotherapy sliding window technique. Film dosimetry revealed that 0.6% of films exceeded a combination of dose differences {>=}3% or distance to agreement {>=}2 mm. More than 99% of both PTVs received {>=}95% of the prescription dose. Average plan conformity index was 1.13 and mean dose to ipsilateral and contralateral parotid glands were 31.4 Gy and 26.1 Gy, respectively. The mean beam-on time was <3 min and mean number of monitor units was 426. Conclusions: RapidArc achieved excellent target coverage and normal tissue sparing, with delivery completed in less than 3 min. RA is currently our standard intensity-modulated radiotherapy approach for advanced HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Planning for Primary Prostate Cancer With Selective Intraprostatic Boost Determined by {sup 18}F-Choline PET/CT

Purpose: This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by {sup 18}F-choline positron emission tomography/computed tomography (PET/CT). Methods and Materials: Thirty patients with localized prostate cancer underwent {sup 18}F-choline PET/CT before treatment. Two VMAT plans, plan{sub 79} {sub Gy} and plan{sub 100-105} {sub Gy}, were compared for each patient. The whole-prostate planning target volume (PTV{sub prostate}) prescription was 79 Gy in both plans, but plan{sub 100-105} {sub Gy} added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on {sup 18}F-choline PET (IDL{sub suv60%} and IDL{sub suv70%}, respectively, with IDL{sub suv70%} nested inside IDL{sub suv60%} to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Results: Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDL{sub suv60%} adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan{sub 100-105} {sub Gy} had significantly higher TCP than plan{sub 79} {sub Gy} across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan{sub 100-105} {sub Gy}. Conclusions: VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a {sup 18}F-choline PET-defined IDL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

The optimal cosmic epoch for precision cosmology

The statistical uncertainty in measuring the primordial density perturbations on a given comoving scale is dictated by the number of independent regions of that scale that are accessible to an observer. This number varies with cosmic time and diminishes per Hubble volume in the distant past or future of the standard cosmological model. We show that the best constraints on the initial power spectrum of linear density perturbations are accessible (e.g. through 21-cm intensity mapping) at redshifts z ∼ 10, and that the ability to constrain the cosmological initial conditions will deteriorate quickly in our cosmic future.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamical equation of the effective gluon mass

In this article, we derive the integral equation that controls the momentum dependence of the effective gluon mass in the Landau gauge. This is accomplished by means of a well-defined separation of the corresponding ''one-loop dressed'' Schwinger-Dyson equation into two distinct contributions, one associated with the mass and one with the standard kinetic part of the gluon. The entire construction relies on the existence of a longitudinally coupled vertex of nonperturbative origin, which enforces gauge invariance in the presence of a dynamical mass. The specific structure of the resulting mass equation, supplemented by the additional requirement of a positive-definite gluon mass, imposes a rather stringent constraint on the derivative of the gluonic dressing function, which is comfortably satisfied by the large-volume lattice data for the gluon propagator, both for SU(2) and SU(3). The numerical treatment of the mass equation, under some simplifying assumptions, is presented for the aforementioned gauge groups, giving rise to a gluon mass that is a nonmonotonic function of the momentum. Various theoretical improvements and possible future directions are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Designs of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target - Further Studies

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU dispersion targets to LEU for the production of 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier) is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitricacid concentration after dissolution will be ~1 M. The resultant solution will then be run through a column to recover Mo from other target components; the Mo will be stripped from the column with a sodium hydroxide solution that will be compatible with the current purification processes used for dispersion targets. The volume of dissolved-foil solution is assumed to be 500 mL, and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 was chosen.

Stepinski, Dominique C.↗