Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Doping CdSexTe1-x/CdTe Graded Absorber Films with Arsenic for Thin-Film Photovoltaics

CdTe thin-film photovoltaics have demonstrated some of the lowest costs of electricity generation owing to its low material cost and ease of manufacturing. However, the full potential of polycrystalline CdTe photovoltaics can only be realized if the open-circuit voltage can be increased beyond 1 V Open-circuit voltage ~850-900 mV has been consistently observed for state-of-the-art polycrystalline CdTe solar cells. Open-circuit voltage of over 1V has been demonstrated for single crystal CdTe devices by doping with Group V elements. Therefore, this study is aimed at understanding behavior of polycrystalline CdTe devices with arsenic doping, its activation and process and performance optimization in order to overcome current voltage limitations in CdTe solar cells.

14 SOLAR ENERGY↗

III-V/Si Tandem Cells Utilizing Interdigitated Back Contact Si Cells and Varying Terminal Configurations

Integrating wide-bandgap III-V with Si solar cells has been shown to yield higher efficiencies than Si alone: As also presented at this conference, four-terminal efficiencies exceeding 32% have been attained. In this contribution, independent and electrically connected operation of the subcells in such tandem cells is examined. The optics of the tandem cell change significantly if a conducting interconnect, rather than an insulating glass slide, is required between the subcells. These effects are studied, and optically optimized structures for different types of tandem cell operation are presented. It is found that minimizing reflection at the conductive interface between the two cells while maintaining conductivity is the key challenge faced in such devices.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimization of Source Material for in-situ Arsenic Doping via Vapor Transport Deposition of CdTe Films

In-situ doping of CdTe/CdSeTe films with arsenic is performed using pre-doped source material prepared by high pressure Bridgman (HPB) melt growth. Arsenic level in the source material is varied from 1018-1020 cm-3. Correspondingly, dopant incorporation in the films prepared using vapor transport deposition (VTD) varied from 3x1017 cm-3–1x1018cm-3. In this range, dopant activation is found to inversely correlate with the dopant incorporation, suggesting compensation. The results from this study indicate film properties can be adjusted by source material.

41 EE - Solar Energy Technologies Office (EE-4S)↗

12.3% Efficient Lifted-Off and Reconstructed As-Doped CdTe Thin Film Solar Cell

CdTe:As devices grown by MOCVD in the superstrate configuration have been reconfigured to a substrate structure, by employing a cleaving and reconstruction technique. Indium and aluminium doped Zinc oxide (IZO and AZO) layers were used as the transparent front interface without a metal grid. A substrate efficiency of 12.3% was realized with AZO front contact, retaining 80% of the superstrate device efficiency and an impressive approximately 99% of the open-circuit voltage. The IZO-based substrate device on the other hand performed at approximately 69 % retained efficiency. The crucial role of front interfaces is highlighted by the two contacts used here. The results in this work show promise for the development of highly efficient substrate CdTe:As devices.

II-VI semiconductor materials↗

Human Health Risk Assessment for Improper Landfill Disposal of End-of-Life CdTe PV

The present work is a continuation of the 2020 IEA PVPS Task 12 Human Health Risk Assessment Methods for PV Part 3: Module Disposal Risks. The 2020 report performed a human health risk assessment (HHRA) for disposal of a cadmium telluride (CdTe) PV module in an unlined landfill, focusing solely on risks from cadmium. This study extends the 2020 HHRA on CdTe PV, analyzing eleven constituent elements: Cd, Se, Te, Cu, Si, Cr(III), Mo, Sn, Zn, Ni, and Al. The present HHRA was performed through two methods: utilization of the U.S. Environmental Protection Agency's (USEPA) Delisting Risk Assessment Software (DRAS V.4.0) on eight exposure pathways for cancer risk and non-cancer hazards; and comparison of exposure point concentrations to federal standards for groundwater, surface water, air, and soil exposure pathways. Cancer risks and non-cancer hazards posed by elemental leaching through all evaluated exposure pathways, using both methods, were found to be several orders of magnitude below USEPA health-protective thresholds. Cadmium exhibited both the highest risks and lowest uncertainty considering data availability on chemical content, leachate, and federal screening levels.

chemicals↗

Cadmium Telluride Accelerator Consortium (CTAC)

The United States is the leader in cadmium telluride (CdTe) photovoltaic (PV) manufacturing, and CdTe is the second most-deployed solar technology in the world. The CdTe Accelerator Consortium (CTAC) was formed to enhance U.S. technology leadership and competitiveness in CdTe photovoltaics (PV) including increasing cell efficiencies, decreasing module costs, and maintaining or increasing domestic CdTe PV material and module production. Leadership for the 3-year consortium was selected by an NREL team through a competitive solicitation. CTAC was formally announced on August 1st by U.S. Secretary of Energy Jennifer M. Granholm and U.S. Representative Marcy Kaptur at an event held at University of Toledo. We will give an overview of CTAC research directions along with their goals and activities. We can also discuss how CTAC relates to the National Renewable Energy Laboratory (NREL) and to the U.S. Manufacturing of Advanced Cadmium Telluride Photovoltaics Consortium (US-MAC). Visit our poster to find out who leads CTAC and how you can get involved.

costs↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

cadmium compounds↗

Characterization of n-Type Iodine-Doped and Indium-Doped CdTe/Cd-Se-Te Thin Films Fabricated by Close-Spaced Sublimation Epitaxy

In this study, n-type CdTe thin films, specifically iodine-doped CdTe (CdTe:I), indium-doped CdTe (CdTe:In), and indium-doped Cd-Se-Te (CST:In), were synthesized using close-spaced sublimation epitaxy (CSSE). Characterization techniques secondary ion mass spectrometry (SIMS), electron backscatter diffraction (EBSD), Hall-effect measurements, and time-resolved photoluminescence (TRPL) were employed to analyze the chemical, structural, and electronic properties of these materials. The results indicated epitaxial single crystal CSSE films grew on the single crystal substrates, with carrier density ranging from 10^14 - 10^16 cm -3 , and after post-annealing, the minority-carrier lifetimes reach near the radiative limit. Additionally, a preliminary exploration of homojunction structures with an n- type (CdTe:In /CST:In /CdTe:I) /CdTe:P /Cu /Mo configuration was performed. The best device performance was achieved with CdTe:I including CdS aiding in band alignment, resulting in a power conversion efficiency (..eta..) of 2.61% with open circuit voltage (Voc) of 850 mV, fill factor (FF) of 47.8%, and short-circuit current (Jsc) of 6.44 mA/cm 2 . The observed low Jsc and efficiency may be attributed to a buried junction and a poor interface, due to dopant interdiffusion. Consequently, further investigations focusing on interface optimization, diffusion blocking, and reduced recombination through passivation, are crucial to enhancing the efficiency of CSSE CdTe homojunction devices in the future.

cadmium compounds↗

Varistors: A Useful Tool for Superconducting Magnet Quench Protection

A perfect varistor is a constant voltage resistor as a function of current through the resistor. A perfect varistor can't exist, because its resistance would be infinite at zero current. In electronic devices, varistors are often used as surge protectors. A varistor can be used in place of an ordinary resistor as the discharge resistance across superconducting coil sections. When used this way, the integral of I 2 dt during the discharge can be reduced by almost one third. When a varistor is used for quench protection of coils that are coupled to shorted secondary circuits the integral of I 2 dt can be reduced much more. Furthermore, this can be a key factor when coil current densities and stored energies are high as in many potential HTS magnet systems. This paper discusses the types of varistors that are commercially available and their characteristics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermionic emission and energy conversion

This project worked on development of a transformative heat-to-electricity conversion device based on thermionic energy conversion. The research provided a unique opportunity to transform the thermionics technology of the 1950-1990s by applying modern materials and 21st century wafer-scale fabrication methods. Research was conducted to further development of a thermionic energy converter based on modern microfabrication and new low work function anode materials that can surpass all other forms of direct heat-to-electricity conversion. This project completed the following goals: (1) Developed components for use in thermionic energy converters and electron emission devices, including electrode materials for electron emission and electron absorption with ultimate work functions below 5 eV; (2) Designed and fabricated thermionic devices for energy conversion and electron emission based on the components developed in (1); (3) Engineered test systems to characterize electronic, thermal, and mechanical properties of thermionic devices and electron emitters and their components, and test devices and components designed and fabricated in (1) and (2); and (4) Developed theoretical modeling capabilities in support of these technical objectives.

36 MATERIALS SCIENCE↗

Optimizing and commercializing the LBNL Grid Burner for AO Smith Storage Water Heater

The purpose of this project was to demonstrate that the LBNL Ring Burner technology can meet the operating, performance, and emission requirements while operating in a residential appliance. This project successfully met all performance targets and enhanced flame stability of the Ring Burner technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY21 Critview Status [Slides]

The purpose of this presentation is to provide an update for progress related to CritView for FY21. It includes FY21 budget summary, FY21 spending data and breakdown, highlights for FY21, highlights for the technical talks to be given at this TPR, and COVID-19 impacts to NCSP work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗