Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Deep Reinforcement Learning for Residential HVAC Control with Consideration of Human Occupancy

The Artificial Intelligence (AI) development described herein uses model-free Deep Reinforcement Learning (DRL) to minimize energy cost during residential heating, ventilation, and air conditioning (HVAC) operation. Building cooling loads and HVAC operation are difficult to accurately model due to complexity, lack of measurements and data, and model specific performance, so online machine learning is used to allow for real-time readjustment in performance. Energy costs for the multi-zone cooling unit shown in this work are minimized by scheduling on/off commands around dynamic prices. By taking advantage of precooling events that take place when the price is low, the agent is able to reduce operational cost without violating user comfort. The DRL controller was tested in simulation where the learner achieved a 43.89% cost reduction when compared to traditional, fixed-setpoint operation. The system is now ready for the next phase of testing in a live, real-time home environment.

Mckee, Evan↗

Buoyancy Effects in Strongly-pulsed, Turbulent Diffusion Flames

The objective of this experiment is to better understand the combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. The fuel jet is fully-modulated (i.e., completely shut off between pulses) by an externally controlled valve system leading to enhanced fuel/air mixing compared to acoustically excited or partially-modulated jets. Experiments are conducted both in laboratories at UW and WPI and in the GRC 2.2s Drop Tower. A single fuel nozzle with diameter d = 2 mm is centered in a combustor 20 x 20 cm in cross section and 67 cm in height. The gaseous fuel flow (ethylene or a 50/50 ethylene/nitrogen mixture by volume) is fully-modulated by a fast-response solenoid valve with injection times from tau = 4 to tau = 300 ms. The nominal Reynolds number based on the fuel velocity during injection, U(sub jet), is 5,000. A slow oxidizer co-flow properly ventilates the flame and an electrically heated wire loop serves as a continuous ignition source. Diagnostic techniques include video imaging, fine-wire thermocouples and thermopile radiometers, and gas sampling and standard emissions instruments (the last in the laboratory only).

Hermanson, J. C.↗

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

Characterization of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Characterization of the performance of a silver-oxide-based absorbent in terms of its ability to remove both gaseous CO2 and water vapor in an astronaut portable life support systems (PLSS) is discussed. Attention is focused on regeneration of the absorbent from the carbonite state of the oxide state, preconditioning of the absorbent using a humidified gas stream, and absorption breakthrough testing. Based on the results of bench-scale experiments, a test plan is carried out to further characterize the silver-oxide-based absorbent on a larger scale; it calls for examination of the absorbent in both an adiabatic packed bed and a near-isothermal cooled bed configuration. It is demonstrated that the tested absorbent can be utilized in a way that removes substantial amounts of CO2 and water vapor during an 8-hour extravehicular activity mission, and that applying the absorbent to PLSS applications can simplify the ventilation loop.

Kast, Timothy P.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the representation of isopycnal mixing in E3SM (Final Report)

The DOE-supported Energy Exascale Earth System Model (E3SM) is a major attempt by the Department of Energy to develop a new Earth System Model using unstructured grids, which allow for the model to concentrate resolution where it is most needed and avoid numerical artifacts experienced by previous Earth System Models (ESMs) using regular grids in which the lateral resolution becomes extremely fine as the resolution shrinks at the poles. This effort required rewriting many of the algorithms previously developed for regular grids. One algorithm that was problematic in the first version of E3SM was the representation of mixing due to turbulent ocean eddies with scales smaller than the model grid. These mesoscale eddies are the primary way by which tracers are stirred along density surfaces in the ocean interior. In particular, the process of isopycnal mixing exchanges fresher, more oxygenated waters from polar regions with saltier, nutrient-rich and oxygen poor waters from tropical regions. Previous work in our group has shown that this mechanism is vitally important for bringing oxygen into poorly ventilated tropical regions (Gnanadesikan et al., 2012, 2013) and plays a significant role in determining the uptake of anthropogenic carbon dioxide (Gnanadesikan et al., 2015). However, in E3SMv1 this process was turned off, as turning it on caused the model to become unstable. Additionally, the rate of isopycnal mixing is directly proportional to a mixing coefficient $A_{Redi}$ whose value varies from less than 400 m 2 /s to 2000 m 2 /s across contemporary climate models. The main thrusts of this proposal therefore were to: 1.) Improve the numerics of isopycnal mixing in E3SM; 2.) Identify ways in which climate models are sensitive to the isopycnal mixing coefficient; and 3.) Develop better representations of the isopycnal mixing coefficient.

54 ENVIRONMENTAL SCIENCES↗

Impact degassing of water and noble gases from silicates

Previous shock experiments by Ahrens and his colleagues show that degassing of H2O and CO2 occurs at 8-65GPa from hydrous minerals such as serpentine. In early solar system, the impact degassing would have played an important part in the formation of primary-atmospheres of the terrestrial planets. However, degassing conditions of noble gases are not well-known because there are few experiments for them. We conducted some shock recovery experiments to investigate the degassing condition and to understand the degassing mechanisms of water and noble gases. We used natural richterites (Ri), amphibolites (Am), serpentines (Sep) and orthoclases (or) as target samples. These, except Sep, contain radiogenic noble gases such as (40)Ar. The samples were put in stainless steel containers, and were show by a rail gun at ISAS or single-stage powder guns at Nagoya or Tohoku University, Japan. We used two kinds of containers: 'open' type containers having a ventilating path for released volatiles for most of samples and 'closed' type ones for some samples for comparison. On Ri and Sep, we made shock experiments for pre-heated (at 400-500 C) and unheated targets, and for powdered and uncrushed samples. Water and noble gases were analyzed both for the recovered shocked samples and the unshocked original samples, and the fractions of the degassed volatiles were calculated by comparing them. Water content in the sample was analyzed by thermo-gravimetry. Noble gases were extracted by heating the samples under high vacuum and analyzed with a sector-type mass spectrometer.

Azuma, S.↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Preliminary design study of a baseline MIUS

Results of a conceptual design study to establish a baseline design for a modular integrated utility system (MIUS) are presented. The system concept developed a basis for evaluating possible projects to demonstrate an MIUS. For the baseline study, climate conditions for the Washington, D.C., area were used. The baseline design is for a high density apartment complex of 496 dwelling units with a planned full occupancy of approximately 1200 residents. Environmental considerations and regulations for the MIUS installation are discussed. Detailed cost data for the baseline MIUS are given together with those for design and operating variations under climate conditions typified by Las Vegas, Nevada, Houston, Texas, and Minneapolis, Minnesota. In addition, results of an investigation of size variation effects, for 300 and 1000 unit apartment complexes, are presented. Only conceptual aspects of the design are discussed. Results regarding energy savings and costs are intended only as trend information and for use in relative comparisons. Alternate heating, ventilation, and air conditioning concepts are considered in the appendix.

Wolfer, B. M.↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

Space Shuttle Crawler Transporter Sound Attenuation Study

The crawler transporter (CT) is the world's largest tracked vehicle known, weighing 6 million pounds with a length of 131 feet and a width of 113 feet. The Kennedy Space Center (KSC) has two CTs that were designed and built for the Apollo program in the 1960's, maintained and retrofitted for use in the Space Shuttle program. As a key element of the Space Shuttle ground systems, the crawler transports the entire 12-million-pound stack comprising the orbiter, the mobile launch platform (MLP), the external tank (ET), and the solid rocket boosters (SRB) from the Vehicle Assembly Building (VAB) to the launch pad. This rollout, constituting a 3.5-5.0-mile journey at a top speed of 0.9 miles-per-hour, requires over 8 hours to reach either Launch Complex 39A or B. This activity is only a prelude to the spectacle of sound and fury of the Space Shuttle launch to orbit in less than 10 minutes and traveling at orbital velocities of Mach 24. This paper summarizes preliminary results from the Crawler Transporter Sound Attenuation Study, encompassing test and engineering analysis of significant sound sources to measure and record full frequency spectrum and intensity of the various noise sources and to analyze the conditions of vibration. Additionally, data such as ventilation criteria, plus operational procedures were considered to provide a comprehensive noise suppression design for implementation. To date, sound attenuation study and results on Crawler 2 have shown significant noise reductions ranging from 5 to 24 dBA.

Margasahayam, Ravi N.↗

Fire safety experiments on MIR Orbital Station

The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber temperature is also controlled. The main objectives of experiments of this series were as follows: (1) verification of the reliability of the installation in orbital flight; (2) verification of the experimental procedure; and (3) investigation of combustion of two types of materials under microgravity at various velocities of the incoming air flow.

Egorov, S. D.↗

Mitigation of ventilation air methane (VAM) using novel methanotrophic coating materials: a technical analysis

Abstract Ventilation air methane (VAM) is a potent greenhouse gas source originating from geological wells, current and extinct mineshafts and other terrestrial conduits venting methane to the atmosphere, contributing to global methane emissions and disproportionate warming potential. Herein, we introduce the concept of the methanotrophic material as an engineering solution. Such materials should be capable of converting methane at ambient temperatures and pressures to a binder product, capturing and permanently sequestering the methane while simultaneously restricting its further emission. While such materials are currently under research development, this goal is supported and facilities by the mathematical framework, introduced and used herein, to evaluate the ability to convert methane, using currently published activity data. We include a case study of the conversion of a characteristic stream of VAM (0.6% methane in air, 1.7 × 10 8 l hr −1 equivalent to 100 000 standard cubic feet per minute). We show that when appropriately designed, such systems require a surface coverage of less than 1000 m of mine tunnel length (equivalent to 20 000 m 2 areal coverage) in order to reduce the methane emission from this stream by over 99%. Finally, we highlight formaldehyde as a reactive intermediate of methane oxidation which may itself be incorporated into these coating materials. As a component of binders and polymers already used ubiquitously in commercial products, this intermediate ultimately allows these systems to sequester the carbon from methane in a stable and solid form. The results presented here are easily extended to the treatment of other methane streams—either more concentrated or dilute—and the results herein will guide the design and development of a new class of carbon-negative materials.

Environmental Sciences & Ecology↗

A Multidisciplinary Modeling Approach of Plant Gas Exchange in Reduced Gravity Environments

In-situ food production is a necessary step for human exploration of the solar system and requires a deep understanding of plant growth in reduced gravity environments. In particular, the lack of buoyancy-driven convection changes the gas exchange at the leaf surface, which decreases photosynthesis and transpiration rates, and ultimately biomass production. To understand the intricate relations between physical, chemical, and biochemical processes, the following methodology combines the development of a mechanistic model of plant growth in reduced gravity environments, computational fluid dynamics (CFD) simulations, and experiments in different time frames.The model presented here is a coupled mass and energy balance using the single round leaf assumption, including gravity as an entry parameter, and the leaf surface temperature as an output variable. Measures of the leaf surface temperature using infra-red cameras allow for a computation of the transpiration rate. This approach was followed to design a parabolic flight experiment, which performed 7 flights, and enabled data collection for model validation in different gravity and ventilation settings on a short time frame. Current measures of carbon assimilation and transpiration rate at the leaf and canopy level using an infra-red gas analyzer (Li-6800) in 1g lab conditions on several species will enable a validation on longer time frames and further calibration of the model. CFD studies both on the parabolic flight and on the lab experimental set-up allow the precise assessment of ventilation above the canopy and plants' leaves.Ultimately, this work will provide recommendations for the design of future plant growth hardware, especially on the lowest adequate ventilation for optimal plant growth in reduced gravity environments, as well as assessing biomass and oxygen production rates on planetary surfaces and space stations. This work was funded by CNES, CNRS, Clermont Auvergne Metropole, and NASA Space Biology through NASA postdoctoral program / USRA.

Poulet, Lucie↗

Accelerated Climate Model for Energy (ACME): Ocean and Sea-Ice Processes

The primary goal of this project was to understand the role of the ocean and sea-ice components in the evolution of the climate in both a high-resolution fully-coupled 1850 preindustrial control and present day transient climate simulations run using the Energy Exascale Earth System Model (E3SM), formerly known as the Accelerated Climate Model for Energy (ACME). Two distinct approaches to the initialization of the present day transients were tested: in the first, an ensemble of three transients used atmospheric reanalysis forced 0.1-degree ocean/sea-ice states, while a fourth transient was branched off the preindustrial control. Biases from the control were inherited by its successor transient, in particular, sea surface temperatures (SSTs) at high latitudes were too warm and too much northward meridional heat transport occurred in the North Atlantic Ocean. SSTs in the Northern Hemisphere and Atlantic meridional heat transport increased in the transients initialized from the ocean/sea-ice simulation over a 40-50 year period to largely resemble the transient branched off the control simulation. Excessive absorbed solar radiation (ASR) is considered to be responsible for the SST biases as well as the formation of mode waters in lighter density classes than in reality both in the Southern Ocean and the North Atlantic Ocean subtropical gyre. These mode waters ventilate the thermocline waters to the north of their formation sites explaining the excessive Atlantic meridional heat transport and some of the warming in the high-latitude North Atlantic Ocean after multiple decades.

54 ENVIRONMENTAL SCIENCES↗

Circulating SARS-CoV-2 + megakaryocytes are associated with severe viral infection in COVID-19

Several independent lines of evidence suggest that megakaryocytes are dysfunctional in severe COVID-19. Herein, we characterized peripheral circulating megakaryocytes in a large cohort of inpatients with COVID-19 and correlated the subpopulation frequencies with clinical outcomes. Using peripheral blood, we show that megakaryocytes are increased in the systemic circulation in COVID-19, and we identify and validate S100A8/A9 as a defining marker of megakaryocyte dysfunction. We further reveal a subpopulation of S100A8/A9 + megakaryocytes that contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) protein and RNA. Using flow cytometry of peripheral blood and in vitro studies on SARS-CoV-2–infected primary human megakaryocytes, we demonstrate that megakaryocytes can transfer viral antigens to emerging platelets. Mechanistically, we show that SARS-CoV-2–containing megakaryocytes are nuclear factor κB (NF-κB)-activated, via p65 and p52; express the NF-κB–mediated cytokines interleukin-6 (IL-6) and IL-1β; and display high surface expression of Toll-like receptor 2 (TLR2) and TLR4, canonical drivers of NF-κB. In a cohort of 218 inpatients with COVID-19, we correlate frequencies of megakaryocyte subpopulations with clinical outcomes and show that SARS-CoV-2–containing megakaryocytes are a strong risk factor for mortality and multiorgan injury, including respiratory failure, mechanical ventilation, acute kidney injury, thrombotic events, and intensive care unit admission. Furthermore, we show that SARS-CoV-2 + megakaryocytes are present in lung and brain autopsy tissues from deceased donors who had COVID-19. To our knowledge, this study offers the first evidence implicating SARS-CoV-2 + peripheral megakaryocytes in severe disease and suggests that circulating megakaryocytes warrant investigation in inflammatory disorders beyond COVID-19.

60 APPLIED LIFE SCIENCES↗