Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Clinical Evaluation of Spatial Accuracy of a Fusion Imaging Technique Combining Previously Acquired Computed Tomography and Real-Time Ultrasound for Imaging of Liver Metastases

Purpose: This study was designed to evaluate the spatial accuracy of matching volumetric computed tomography (CT) data of hepatic metastases with real-time ultrasound (US) using a fusion imaging system (VNav) according to different clinical settings. Methods: Twenty-four patients with one hepatic tumor identified on enhanced CT and US were prospectively enrolled. A set of three landmarks markers was chosen on CT and US for image registration. US and CT images were then superimposed using the fusion imaging display mode. The difference in spatial location between the tumor visible on the CT and the US on the overlay images (reviewer no. 1, comment no. 2) was measured in the lateral, anterior-posterior, and vertical axis. The maximum difference (Dmax) was evaluated for different predictive factors.CT performed 1-30 days before registration versus immediately before. Use of general anesthesia for CT and US versus no anesthesia.Anatomic landmarks versus landmarks that include at least one nonanatomic structure, such as a cyst or a calcificationResultsOverall, Dmax was 11.53 {+-} 8.38 mm. Dmax was 6.55 {+-} 7.31 mm with CT performed immediately before VNav versus 17.4 {+-} 5.18 with CT performed 1-30 days before (p < 0.0001). Dmax was 7.05 {+-} 6.95 under general anesthesia and 16.81 {+-} 6.77 without anesthesia (p < 0.0015). Landmarks including at least one nonanatomic structure increase Dmax of 5.2 mm (p < 0.0001). The lowest Dmax (1.9 {+-} 1.4 mm) was obtained when CT and VNav were performed under general anesthesia, one immediately after the other. Conclusions: VNav is accurate when adequate clinical setup is carefully selected. Only under these conditions (reviewer no. 2), liver tumors not identified on US can be accurately targeted for biopsy or radiofrequency ablation using fusion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transthoracic Computed Tomography-Guided AICD Insertion in a Patient with Extracardiac Fontan Conduit

Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To evaluate the sensitivity of dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA) for the detection of hepatocellular carcinoma (HCC) by comparing it with the diagnostic imaging 'gold standard': contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. Materials and Methods: Eighty-eight HCC lesions (mean diameter 3.9 {+-} 3.3 cm) in 20 patients (13 men, mean age 61.4 years [range 50 to 80]), who sequentially underwent baseline diagnostic liver CE-MRI and then underwent early arterial- and delayed portal venous-phase CBCTHA during drug eluting-bead transarterial chemoembolization, were evaluated. Dual-phase CBCTHA findings of each tumor in terms of conspicuity were compared with standard CE-MR images and classified into three grades: optimal, suboptimal, and nondiagnostic. Results: Seventy-seven (mean diameter 4.2 {+-} 3.4 cm [range 0.9 to 15.9]) (93.9%) of 82 tumors were detected. Sensitivity of arterial-phase (71.9%) was lower than that of venous-phase CBCTHA (86.6%) for the detection of HCC lesions. Of the 82 tumors, 33 (40.2%) and 52 (63.4%), 26 (31.7%) and 19 (23.2%), and 23 (28%) and 11 (13.4%) nodules were classed as optimal, suboptimal, and nondiagnostic on arterial- and venous-phase CBCTHA images, respectively. Seventeen (73.9%) of the 23 tumors that were not visible on arterial phase were detected on venous phase. Six (54.5%) of the 11 tumors that were not visible on venous phase were detected on arterial phase. Conclusions: Dual-phase CBCTHA has sufficient image quality to detect the majority of HCC lesions compared with the imaging 'gold standard': CE-MRI of the liver. Moreover, dual-phase CBCTHA is more useful and reliable than single-phasic imaging to depict HCC nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Ambient occlusion – A powerful algorithm to segment shell and skeletal intrapores in computed tomography data

During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region.Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably.Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that at were superior to or impossible to obtain with commonly used distance-map-based segmentations. The combined usage of various AO-derived fields by supervisd or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.

Computed tomography, Micro-computed tomography, Po↗

Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

Purpose: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV{sub h}) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV{sub h} increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ({sup 18}F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials: {sup 18}F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and {sup 18}F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated {sup 18}F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate {sup 18}F-FMISO PET/CT-guided IMRT plans. Results: The heterogeneous distribution of {sup 18}F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing {sup 18}F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV{sub h} and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV{sub h} for 2 patients and were successful in 1, with normal tissue sparing. Conclusion: It was feasible to dose escalate the GTV{sub h} to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}-F-Fluorodeoxyglucose-Positron Emission Tomography Evaluation of Early Metabolic Response During Radiation Therapy for Cervical Cancer

Purpose: To document changes in cervical tumor {sup 18}-F-fluorodeoxyglocose (FDG) uptake during radiation therapy and to correlate those changes with post-treatment tumor response and survival outcome. Methods and Materials: A total of 36 patients with Stage Ib1 to IIIb cervical cancer were enrolled in an institutional protocol examining the use of fluorodeoxyglucose-positron emission tomography (FDG-PET) for brachytherapy treatment planning. As part of this study, FDG-PET or PET/computed tomograpy (CT) images were obtained before, during, and after the completion of radiation therapy. Tumor metabolic responses were assessed qualitatively and semi-quantitatively by measurement of the maximal standardized uptake value (SUV{sub max}). Results: Post-treatment FDG-PET images were obtained for 36 patients in this study. Of the patients, 29 patients had a complete metabolic response on the post-treatment PET, 4 had a partial metabolic response, and 3 had new sites of FDG uptake. Six patients had a complete metabolic response observed during radiation therapy, 26 had a partial metabolic response and 4 had stable or increased tumor metabolic activity. For patients with complete metabolic response during radiation therapy, median time to complete response was 29.5 days (range, 18-43 days). The mean cervical tumor SUV{sub max} decreased from 11.2 (SD, 6.3; range, 2.1-38.0) pretreatment to 2.4 (SD, 2.7; range, 0-8.8) mid treatment, and 0.5 (SD, 1.7; range, 0-8.3) post-treatment. Conclusions: During radiation therapy for cervical cancer, FDG-PET can be used to monitor treatment response. Complete metabolic response during radiation therapy was observed for a subset of patients. Recommendations regarding the optimal timing of FDG-PET during treatment for cervical cancer will require further systematic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Soft-Tissue Contrast in Four-Dimensional Computed Tomography Images of Liver Cancer Patients Using a Deformable Image Registration Method

Purpose: To investigate a deformable image registration method to improve soft-tissue contrast in four-dimensional (4D) computed tomography (CT) images of the liver. Methods and Materials: Ten patients with hepatocellular carcinoma underwent 4D CT scan for radiotherapy treatment planning on a positron emission tomography/CT scanner. Four-dimensional CT images were binned into 10 equispaced phases. The exhale phase served as the reference phase, and images from the other nine phases were coregistered to the reference phase image using an intensity-based, automatic deformable image registration method. Then the coregistered images were combined to create a single, high-quality reconstructed CT image at exhale phase as the new reference for target delineation. The extent of image quality enhancement was quantified relative to the original CT by calculating the signal-to-noise ratio and the contrast-to-noise ratio. Results: The soft tissue image contrast was noticeably better after deformable image registration than in the original scans. Signal-to-noise ratios inside the liver region of interest increased for all patients by a factor of 3.0 (range, 2.3-3.7). The improvement in image quality was not linearly proportionate to the number of images averaged. Using only 6 phases can achieve at least 85% of the contrast enhancement that can be achieved using all 10 phases. We also found that contrast enhancement was inversely proportional to the original image quality (p = 0.006), and the contrast enhancement is attained with little loss of spatial resolution. Conclusions: This deformable image registration method is feasible to improve soft-tissue image quality in 4D CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Fluorodeoxyglucose Positron Emission Tomography to Assess Tumor Volume During Radiotherapy for Non-Small-Cell Lung Cancer and Its Potential Impact on Adaptive Dose Escalation and Normal Tissue Sparing

Purpose: To quantify changes in fluorodeoxyglucose (FDG)-avid tumor volume on positron emission tomography/computed tomography (PET/CT) during the course of radiation therapy and examine its potential use in adaptive radiotherapy for tumor dose escalation or normal tissue sparing in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: As part of a pilot study, patients with Stage I-III NSCLC underwent FDG-PET/CT before radiotherapy (RT) and in mid-RT (after 40-50 Gy). Gross tumor volumes were contoured on CT and PET scans obtained before and during RT. Three-dimensional conformal RT plans were generated for each patient, first using only pretreatment CT scans. Mid-RT PET volumes were then used to design boost fields. Results: Fourteen patients with FDG-avid tumors were assessed. Two patients had a complete metabolic response, and 2 patients had slightly increased FDG uptake in the adjacent lung tissue. Mid-RT PET scans were useful in the 10 remaining patients. Mean decreases in CT and PET tumor volumes were 26% (range, +15% to -75%) and 44% (range, +10% to -100%), respectively. Designing boosts based on mid-RT PET allowed for a meaningful dose escalation of 30-102 Gy (mean, 58 Gy) or a reduction in normal tissue complication probability (NTCP) of 0.4-3% (mean, 2%) in 5 of 6 patients with smaller yet residual tumor volumes. Conclusions: Tumor metabolic activity and volume can change significantly after 40-50 Gy of RT. Using mid-RT PET volumes, tumor dose can be significantly escalated or NTCP reduced. Clinical studies evaluating patient outcome after PET-based adaptive RT are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Customized Computed Tomography-Based Boost Volumes in Breast-Conserving Therapy: Use of Three-Dimensional Histologic Information for Clinical Target Volume Margins

Purpose: To determine the difference in size between computed tomography (CT)-based irradiated boost volumes and simulator-based irradiated volumes in patients treated with breast-conserving therapy and to analyze whether the use of anisotropic three-dimensional clinical target volume (CTV) margins using the histologically determined free resection margins allows for a significant reduction of the CT-based boost volumes. Patients and Methods: The CT data from 49 patients were used to delineate a planning target volume (PTV) with isotropic CTV margins and to delineate a PTV{sub sim} that mimicked the PTV as delineated in the era of conventional simulation. For 17 patients, a PTV with anisotropic CTV margins was defined by applying customized three-dimensional CTV margins, according to the free excision margins in six directions. Boost treatment plans consisted of conformal portals for the CT-based PTVs and rectangular fields for the PTV{sub sim}. Results: The irradiated volume (volume receiving >=95% of the prescribed dose [V{sub 95}]) for the PTV with isotropic CTV margins was 1.6 times greater than that for the PTV{sub sim}: 228 cm{sup 3} vs. 147 cm{sup 3} (p < .001). For the 17 patients with a PTV with anisotropic CTV margins, the V{sub 95} was similar to the V{sub 95} for the PTV{sub sim} (190 cm{sup 3} vs. 162 cm{sup 3}; p = NS). The main determinant for the irradiated volume was the size of the excision cavity (p < .001), which was mainly related to the interval between surgery and the planning CT scan (p = .029). Conclusion: CT-based PTVs with isotropic margins for the CTV yield much greater irradiated volumes than fluoroscopically based PTVs. Applying individualized anisotropic CTV margins allowed for a significant reduction of the irradiated boost volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Interfraction and Intrafraction Tumor Motion in Lung Stereotactic Body Radiotherapy Using Respiration-Correlated Cone Beam Computed Tomography

Purpose: Stereotactic body radiation therapy (SBRT) is an effective treatment for medically inoperable Stage I non-small-cell lung cancer. However, changes in the patient's breathing patterns during the course of SBRT may result in a geographic miss or an overexposure of healthy tissues to radiation. However, the precise extent of these changes in breathing pattern is not well known. We evaluated the inter- and intrafractional changes in tumor motion amplitude (DELTAM) over an SBRT course. Methods and Materials: Eighteen patients received image-guided SBRT delivered in three fractions; this therapy was done with abdominal compression in four patients. For each fraction, cone beam computed tomography (CBCT) was performed for tumor localization (+- 3-mm tolerance) and then repeated to confirm geometric accuracy. Additional CBCT images were acquired at the midpoint and end of each SBRT fraction. Respiration-correlated CBCT (rcCBCT) reconstructions allowed retrospective assessment of inter- and intrafractional DELTAM by a comparison of tumor displacements in all four-dimensional CT and rcCBCT scans. The DELTAM was measured in mediolateral, superior-inferior, and anterior-posterior directions. Results: A total of 201 rcCBCT images were analyzed. The mean time from localization of the tumor to the end-fraction CBCT was 35 +- 7 min. Compared with the motion recorded on four-dimensional CT, the mean DELTAM was 0.4, 1.0, and 0.4 mm, respectively, in the mediolateral, superior-inferior, and anterior-posterior directions. On treatment, the observed DELTAM was, on average, <1 mm; no DELTAM was statistically different with respect to the initial rcCBCT. However, patients in whom abdominal compression was used showed a statistically significant difference (p < 0.05) in the variance of DELTAM with respect to the initial rcCBCT in the superior-inferior direction. Conclusions: The inter- and intrafractional DELTAM that occur during a course of lung SBRT are small. However, abdominal compression causes larger variations in the time spent on the treatment couch and in the inter- and intrafractional DELTAM values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study

Purpose: To report on a prospective clinical trial of the use of daily kilovoltage cone-beam computed tomography (CBCT) to evaluate the interfraction and residual error motion of patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Methods and Materials: Patients were treated with intensity-modulated radiotherapy with an Elekta linear accelerator using a mounted CBCT scanner. CBCT was performed before every treatment, and translational (but not rotational) corrections were performed. At least once per week, a CBCT scan was obtained after intensity-modulated radiotherapy. Variations were measured in the medial-lateral, superoinferior, and anteroposterior dimensions, as well as in the rotation around these axes. Results: A total of 28 consecutive patients (1,013 CBCT scans) were studied. The average interfraction shift was 1.4 +- 1.4, 1.7 +- 1.9, and 1.8 +- 2.1 mm in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. The corresponding average residual error shifts were 0.7 +- 0.8, 0.9 +- 0.9, and 0.9 +- 0.9 mm. These data indicate that in the absence of daily CBCT image-guided radiotherapy, a clinical target volume to planning target volume margin of 3.9, 4.1, and 4.9 mm is needed in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. With daily CBCT, corresponding margins of 1.6, 2.5, and 1.9 mm should be acceptable. Subgroup analyses showed that larynx cancers and/or intratreatment weight loss indicate a need for slightly larger clinical target volume to planning target volume margins. Conclusion: The results of our study have shown that image-guided radiotherapy using CBCT for head-and-neck cancer is effective. These data suggest it allows a reduction in the clinical target volume to planning target volume margins by about 50%, which could facilitate future studies of dose escalation and/or improved toxicity reduction. Caution is particularly warranted for cases in which the targets are mobile (e.g., the tongue).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Respiratory-Gated and Respiratory-Ungated Planning in Scattered Carbon Ion Beam Treatment of the Pancreas Using Four-Dimensional Computed Tomography

Purpose: We compared respiratory-gated and respiratory-ungated treatment strategies using four-dimensional (4D) scattered carbon ion beam distribution in pancreatic 4D computed tomography (CT) datasets. Methods and Materials: Seven inpatients with pancreatic tumors underwent 4DCT scanning under free-breathing conditions using a rapidly rotating cone-beam CT, which was integrated with a 256-slice detector, in cine mode. Two types of bolus for gated and ungated treatment were designed to cover the planning target volume (PTV) using 4DCT datasets in a 30% duty cycle around exhalation and a single respiratory cycle, respectively. Carbon ion beam distribution for each strategy was calculated as a function of respiratory phase by applying the compensating bolus to 4DCT at the respective phases. Smearing was not applied to the bolus, but consideration was given to drill diameter. The accumulated dose distributions were calculated by applying deformable registration and calculating the dose-volume histogram. Results: Doses to normal tissues in gated treatment were minimized mainly on the inferior aspect, which thereby minimized excessive doses to normal tissues. Over 95% of the dose, however, was delivered to the clinical target volume at all phases for both treatment strategies. Maximum doses to the duodenum and pancreas averaged across all patients were 43.1/43.1 GyE (ungated/gated) and 43.2/43.2 GyE (ungated/gated), respectively. Conclusions: Although gated treatment minimized excessive dosing to normal tissue, the difference between treatment strategies was small. Respiratory gating may not always be required in pancreatic treatment as long as dose distribution is assessed. Any application of our results to clinical use should be undertaken only after discussion with oncologists, particularly with regard to radiotherapy combined with chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography-Derived Adaptive Radiotherapy for Radical Treatment of Esophageal Cancer

Purpose: To investigate the potential for reduction in normal tissue irradiation by creating a patient specific planning target volume (PTV) using cone beam computed tomography (CBCT) imaging acquired in the first week of radiotherapy for patients receiving radical radiotherapy. Methods and materials: Patients receiving radical RT for carcinoma of the esophagus were investigated. The PTV is defined as CTV(tumor, nodes) plus esophagus outlined 3 to 5 cm cranio-caudally and a 1.5-cm circumferential margin is added (clinical plan). Prefraction CBCT are acquired on Days 1 to 4, then weekly. No correction for setup error made. The images are imported into the planning system. The tumor and esophagus for the length of the PTV are contoured on each CBCT and 5 mm margin is added. A composite volume (PTV1) is created using Week 1 composite CBCT volumes. The same process is repeated using CBCT Week 2 to 6 (PTV2). A new plan is created using PTV1 (adaptive plan). The coverage of the 95% isodose of PTV1 is evaluated on PTV2. Dose-volume histograms (DVH) for lungs, heart, and cord for two plans are compared. Results: A total of 139 CBCT for 14 cases were analyzed. For the adaptive plan the coverage of the 95% prescription isodose for PTV1 = 95.6% +- 4% and the PTV2 = 96.8% +- 4.1% (t test, 0.19). Lungs V20 (15.6 Gy vs. 10.2 Gy) and heart mean dose (26.9 Gy vs. 20.7 Gy) were significantly smaller for the adaptive plan. Conclusions: A reduced planning volume can be constructed within the first week of treatment using CBCT. A single plan modification can be performed within the second week of treatment with considerable reduction in organ at risk dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography Perfusion Assessment of Radiation Therapy Effects on Spinal Cord Hemodynamics

Purpose: We used computed tomography (CT) perfusion to evaluate the acute and late effect of radiation therapy (RT) on spinal cord (SC) hemodynamics in patients without symptoms of myelopathy. We hypothesized that SC perfusion could be acutely altered during RT. Methods and Materials: We analyzed neck CT perfusion studies of 36 head-and-neck cancer patients (N1), 16 of whom had previously undergone RT. In a separate group of 6 patients (N2), CT perfusion studies were obtained before RT, after 40 Gy, and after treatment completion. Results: In the N1 group, SC blood flow (BF), blood volume (BV), mean transit time (MTT), and capillary permeability (CP) maps were not significantly different between RT-treated and RT-naive patients. In the N2 group, BF and CP were significantly increased during treatment compared with the baseline and post-RT studies. Conclusions: Radiation therapy of the head and neck may cause transient perturbations of SC perfusion that seem to reverse after treatment. There are no definite chronic effects of RT on SC perfusion observeable at the typical doses administered during treatment of head and neck malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Artifact Reduction With Real-Time Cine Four-Dimensional Computed Tomography Acquisition Methods

Purpose: To quantify the magnitude and frequency of artifacts in simulated four-dimensional computed tomography (4D CT) images using three real-time acquisition methods- direction-dependent displacement acquisition, simultaneous displacement and phase acquisition, and simultaneous displacement and velocity acquisition- and to compare these methods with commonly used retrospective phase sorting. Methods and Materials: Image acquisition for the four 4D CT methods was simulated with different displacement and velocity tolerances for spheres with radii of 0.5 cm, 1.5 cm, and 2.5 cm, using 58 patient-measured tumors and respiratory motion traces. The magnitude and frequency of artifacts, CT doses, and acquisition times were computed for each method. Results: The mean artifact magnitude was 50% smaller for the three real-time methods than for retrospective phase sorting. The dose was {approx}50% lower, but the acquisition time was 20% to 100% longer for the real-time methods than for retrospective phase sorting. Conclusions: Real-time acquisition methods can reduce the frequency and magnitude of artifacts in 4D CT images, as well as the imaging dose, but they increase the image acquisition time. The results suggest that direction-dependent displacement acquisition is the preferred real-time 4D CT acquisition method, because on average, the lowest dose is delivered to the patient and the acquisition time is the shortest for the resulting number and magnitude of artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗