Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Targeting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Selective Targeting by a Mechanism-Based Inactivator against Pyridoxal 5'-Phosphate-Dependent Enzymes: Mechanisms of Inactivation and Alternative Turnover

Potent mechanism-based inactivators can be rationally designed against pyridoxal 5'-phosphate (PLP)-dependent drug targets, such as ornithine aminotransferase (OAT) or γ-aminobutyric acid aminotransferase (GABA-AT). An important challenge, however, is the lack of selectivity toward other PLP-dependent, off-target enzymes, because of similarities in mechanisms of all PLP-dependent aminotransferase reactions. On the basis of complex crystal structures, we investigate the inactivation mechanism of OAT, a hepatocellular carcinoma target, by (1R,3S,4S)-3-amino-4-fluorocyclopentane-1-carboxylic acid (FCP), a known inactivator of GABA-AT. A crystal structure of OAT and FCP showed the formation of a ternary adduct. This adduct can be rationalized as occurring via an enamine mechanism of inactivation, similar to that reported for GABA-AT. Interestingly, however, the crystal structure of an off-target, PLP-dependent enzyme, aspartate aminotransferase (Asp-AT), in complex with FCP, along with the results of attempted inhibition assays, suggests that FCP is not an inactivator of Asp-AT, but rather an alternate substrate. Turnover of FCP by Asp-AT is also supported by high-resolution mass spectrometry. Amid existing difficulties in achieving selectivity of inactivation among a large number of PLP-dependent enzymes, the obtained results provide evidence that a desirable selectivity could be achieved, taking advantage of subtle structural and mechanistic differences between a drug-target enzyme and an off-target enzyme, despite their largely similar substrate binding sites and catalytic mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanism-Based Tumor-Targeting Drug Delivery System. Validation of Efficient Vitamin Receptor-Mediated Endocytosis and Drug Release

An efficient mechanism-based tumor-targeting drug delivery system, based on tumor-specific vitamin-receptor mediated endocytosis, has been developed. The tumor-targeting drug delivery system is a conjugate of a tumor-targeting molecule (biotin: vitamin H or vitamin B-7), a mechanism-based self-immolative linker and a second-generation taxoid (SB-T-1214) as the cytotoxic agent. This conjugate (1) is designed to be (i) specific to the vitamin receptors overexpressed on tumor cell surface and (ii) internalized efficiently through receptor-mediated endocytosis, followed by smooth drug release via glutathione-triggered self-immolation of the linker. In order to monitor and validate the sequence of events hypothesized, i.e., receptor-mediated endocytosis of the conjugate, drug release, and drug-binding to the target protein (microtubules), three fluorescent/fluorogenic molecular probes (2, 3, and 4) were designed and synthesized. The actual occurrence of these processes was unambiguously confirmed by means of confocal fluorescence microscopy (CFM) and flow cytometry using L1210FR leukemia cells, overexpressing biotin receptors. The molecular probe 4, bearing the taxoid linked to fluorescein, was also used to examine the cell specificity (i.e., efficacy of receptor-based cell targeting) for three cell lines, L1210FR (biotin receptors overexpressed), L1210 (biotin receptors not overexpressed), and WI38 (normal human lung fibroblast, biotin receptor negative). As anticipated, the molecular probe 4 exhibited high specificity only to L1210FR. To confirm the direct correlation between the cell-specific drug delivery and anticancer activity of the probe 4, its cytotoxicity against these three cell lines was also examined. The results clearly showed a good correlation between the two methods. In the same manner, excellent cell-specific cytotoxicity of the conjugate 1 (without fluorescein attachment to the taxoid) against the same three cell lines was confirmed. This mechanism-based tumor-targeting drug delivery system will find a range of applications.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of a tellurium-packed column for isolation of astatine-211 from irradiated bismuth targets and demonstration of a semi-automated system

Astatine-211 is an attractive radionuclide for use in targeted alpha therapy of blood-borne diseases and micrometastatic diseases. Efficient isolation methods that can be adapted to robust automated 211 At isolation systems are of high interest for improving the availability of 211 At. Based on the early studies of Bochvarova and co-workers involving isolation of 211 At from irradiated thorium targets, we developed a method for 211 At isolation from bismuth targets using tellurium-packed columns. Dissolution of irradiated bismuth targets is accomplished using HNO 3 ; however, 211 At is not captured on the Te column material in this matrix. Our method involves slow addition of aqueous NH 2 OH·HCl to the Bi target dissolved in HNO 3 to convert to a HCl matrix. The amount of NH 2 OH·HCl was optimized because (1) the quantity of NH 2 OH·HCl used appears to affect the radiolabeling yield of phenethyl- closo -decaborate(2-) (B10)-conjugated antibodies and (2) reducing the volume of NH 2 OH·HCl solution can effectively shorten the overall isolation time. A proof-of-concept semi-automated process has been demonstrated using targets containing ~0.96 GBq (~26 mCi) of 211 At. High isolation yields (88–95%) were obtained. Radiochemical purity of the isolated 211 At was assessed by radio-HPLC. Concentrations of Bi and Te contaminants in the 211 At and the astatinated antibodies were evaluated using ICP-MS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Target electron collision effects on energy loss straggling of protons in an electron gas at any degeneracy

The purpose of the present paper is to describe the effects of target electron collisions on proton energy loss straggling in plasmas at any degeneracy. Targets are considered fully ionized so electronic energy loss is only due to the free electrons. The analysis is focused on targets with electronic density around solid values n{sub e}{approx_equal}10{sup 23} cm{sup -3} and with temperature around T{approx_equal}10 eV; these targets are in the limit of weakly coupled electron gases. These types of plasma targets have not been studied extensively, though they are very important for inertial confinement fusion. The energy loss straggling is obtained from an exact quantum-mechanical evaluation, which takes into account the degeneracy of the target plasma, and later it is compared with common classical and degenerate approximations. Then electron collisions in the exact quantum-mechanical straggling calculation are considered. Now the energy loss straggling is enhanced for energies smaller than the energy before the maximum, then decreases around this maximum, and finally tends to the same values with respect to noncollisional calculation. Differences with the same results but not taking into account these collisions are as far as 17% in the cases analyzed. As an example, proton range distributions have been calculated to show the importance of an accurate energy straggling calculation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joint Experiments on X-ray/Particle Emission from Plasmas Produced by Laser Irradiating Nano Structured Targets

The 1st Joint (Host Laboratory) Experiment on laser plasma involving more than twenty scientists from eight countries has been carried out at the Laser and New Materials Laboratory, Faculty of Science, Cairo University, Egypt. It was co-ordinated by the International Atomic Energy Agency (IAEA) and supported through the IAEA and the ICTP (International Centre for Theoretical Physics, Trieste). The main experimental programme was aimed at characterising the possible enhancement of x-ray and particle emission from plasmas produced by laser incidence on nano-structured targets. Laser beams at 1.064 {mu}m of 250 mJ and 532 nm of 165 mJ focused at the target surface using a nanosecond laser type Quantel were used in the present study. In the present experiments nano-copper structures evaporated onto copper bulk disks and nano-gold structures evaporated onto gold ones were used. The thickness of the nano-materials on their bulk material was 1 {mu}m. An ion collector and x-ray semiconductor diode were used to study the ion and x-ray emission, respectively. Both were positioned at the same port at 90 deg. with respect to the target surface and at 90 cm from the surface in the case of the ion collector and 55 cm in the case of the x-ray detector. These experiments were performed at vacuum pressures of (5--8)x10{sup -6} mbar. Comparison of both studies in the case of nano structured targets and bulk targets were performed at different laser fluencies (1x10{sup 9}-1x10{sup 12} W/cm{sup 2}) on the target. A 20% increase of the X-ray emission for nano gold with respect to bulk gold was observed, however, the x-ray emission in the of nano copper and copper was the same.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increased efficiency of short-pulse laser-generated proton beams from novel flat-top cone targets

Ion-driven fast ignition (IFI) may have significant advantages over electron-driven FI due to the potentially large reduction in the amount of energy required for the ignition beam and the laser driver. Recent experiments at the Los Alamos National Laboratory's Trident facility employing novel Au flat-top cone targets have produced a fourfold increase in laser-energy to ion-energy efficiency, a 13-fold increase in the number of ions above 10 MeV, and a few times increase in the maximum ion energy compared to Au flat-foil targets. Compared to recently published scaling laws, these gains are even greater. If the efficiency scales with intensity in accordance to flat-foil scaling, then, with little modification, these targets can be used to generate the pulse of ions needed to ignite thermonuclear fusion in the fast ignitor scheme. A proton energy of at least 30 MeV was measured from the flat-top cone targets, and particle-in-cell (PIC) simulations show that the maximum cutoff energy may be as high as 40-45 MeV at modest intensity of 1x10{sup 19} W/cm{sup 2} with 20 J in 600 fs. Simulations indicate that the observed energy and efficiency increase can be attributed to the cone target's ability to guide laser light into the neck to produce hot electrons and transport these electrons to the flat-top of the cone where they can be heated to much higher temperatures, creating a hotter, denser sheath. The PIC simulations also elucidate the critical parameters for obtaining superior proton acceleration such as the dependence on laser contrast/plasma prefill, as well as longitudinal and transverse laser pointing, and cone geometry. These novel cones have the potential to revolutionize inertial confinement fusion target design and fabrication via their ability to be mass produced. In addition, they could have an impact on the general physics community studying basic electron and radiation transport phenomena or as better sources of particle beams to study equations of state and warm dense matter, or for hadron therapy, as new radioisotope generators, or for compact proton radiography sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron source of triode type with radial converging electron flow for irradiation of cylindrical targets

Design of an electron source of triode type is described, which produces a radial converging electron beam employed for modification of the outer surface of fuel element claddings. Experimental investigations of the source showed that beam current magnitude, efficiency of beam focusing to the target, stability of source operation, and beam pulse duration become worse when the target diameter drops below certain values. A method for the calculation of the source operation was developed. Calculations showed that the reason of worse source operation is the initial angular spread of electrons when the target diameter is small. Because of the angular spread a part of electrons passes by the target and oscillates between the target and cathode. The space charge of the oscillating electrons lowers the emission current magnitude and leads to the formation of a virtual cathode in the grid-target gap despite the fact that the emission beam current is less than the limiting one. Formation of a virtual cathode is a reason for the unstable source operation and restriction of the beam pulse duration. Recommendations for the improvement of the source design are suggested.

43 PARTICLE ACCELERATORS↗

The Effects of Target Mounts in Direct-Drive Implosions on OMEGA

The effects of two types of target mounts, stalks and spider silks, on the implosion of both room-temperature D2-gas-filled shells and cryogenic D2-ice-filled shells have been studied both experimentally and by means of two-dimensional simulations. The simulations indicate that the hydrodynamic effect of the expanding plasma created by the ablation of material from the target mounts and refraction of laser light by this plasma induce perturbations in the imploding shell that are damaging to the implosion. The spider silks are the more-damaging type of mount since the silks (typically four) are arrayed over the target surface, whereas the stalk (typically one) meets the target at a single point. Stalks are therefore preferred over silks as a target mount. The scale and magnitude of the perturbations induced by the spider silks have been verified by planar-target experiments performed on the OMEGA laser [T. R. Boehly, D. L. Brown, R. S. Craxton et al., Opt. Commun. 133, 495 (1995)]. The perturbations predicted by simulations to arise from stalks qualitatively agree with the results of implosion experiments using Ti-doped plastic shells.

Igumenshchev, I V↗

Note: Studies on target placement in TE{sub 111} cylindrical cavity of electron cyclotron resonance x-ray source for the enhancement of x-ray dose

X-ray source based on electron cyclotron resonance principle has been constructed using TE{sub 111} cylindrical cavity. At present the device is used to provide low energy x-ray field for thermoluminescent dosimeter badge calibration. Theoretical and experimental studies on the effect of target placement inside the TE{sub 111} cylindrical cavity for enhancing the x-ray output are carried out and the results are presented in this note. Optimum target location is identified by theoretical analysis on the electric field distribution inside the cavity using MICROWAVE STUDIO program. By modifying the magnetic field configuration, the resonance region is shifted to the optimum target location. The microwave transmission line is upgraded with a three stub tuner which improves the microwave coupling from the source to the target loaded cavity. Molybdenum target is located at a radial distance of 2.5 cm from the cavity center and the x-ray dose rate is measured at 20 cm from the exit port for different microwave power. With the introduction of the target, the x-ray output has improved nearly from 70% to 160% in the microwave power of 150-500 W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy transport and isochoric heating of a low-Z, reduced-mass target irradiated with a high intensity laser pulse

Heat transport in reduced-mass targets irradiated with a high intensity laser pulse was studied. K{alpha} lines from partially ionized chlorine embedded in the middle of a triple-layered plastic target were measured to evaluate bulk electron temperature in the tracer region inside the target. Two groups of K{alpha} lines, one from Cl{sup +}-Cl{sup 6+} (hereby called ''cold K{alpha}''), and the other from Cl{sup 9+} and Cl{sup 10+} (''shifted K{alpha}'') are observed from different regions within the target. Two-dimensional collisional particle-in-cell simulations show two distinct heating mechanisms occurring concurrently: uniform heating by refluxing electrons and local heating by diffusive electrons in the central region. These two heating processes, which made the target temperature distribution nonuniform, are responsible for producing the two groups of K{alpha} lines in the experiment. The blue-shift of cold K{alpha} lines in the experiment is the signature of higher temperatures achieved by the refluxing heating in smaller-mass targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser plasma cryogenic target on translating substrate for generation of continuously repetitive EUV and soft X-ray pulses

To generate continuously repetitive EUV and soft X-ray pulses with various wavelengths from laser-produced plasmas, a one-dimensionally translating substrate system with a closed He gas cryostat that can continuously supply various cryogenic targets for ∼10 Hz laser pulses has been developed. The system was successfully operated at a lowest temperature of 15 K and at a maximum up-down speed of 12 mm/s. Solid Ar, Kr, and Xe layers were formed, and their growth rates and the laser crater sizes on them were studied. By optimization of the operational parameters in accordance with our design rule, it was shown that stable output power was achieved continuously from the plasma emission at frequencies of 1–10 Hz. The average soft X-ray and EUV powers obtained were 19 mW at 3.2 nm, 33 mW at 10.0 nm, and 66 mW at 10.8 nm, with 10% bandwidths, from the Ar, Kr, and Xe solid targets, respectively, with a laser power of 1 W. We will be able to achieve higher frequencies using a high beam quality laser that produces smaller craters, and can expect higher powers. Although only Ar, Kr, and Xe gases were tested in this study, the target system achieved a temperature of 15 K and can thus solidify almost all target gases, apart from H and He, and can continuously supply the solid target. The use of various target materials will enable expansion of the EUV and soft X-ray emission wavelength range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A confocal microscope position sensor for micron-scale target alignment in ultra-intense laser-matter experiments

A diagnostic tool for precise alignment of targets in laser-matter interactions based on confocal microscopy is presented. This device permits precision alignment of targets within the Rayleigh range of tight focusing geometries for a wide variety of target surface morphologies. This confocal high-intensity positioner achieves micron-scale target alignment by selectively accepting light reflected from a narrow range of target focal planes. Additionally, the design of the device is such that its footprint and sensitivity can be tuned for the desired chamber and experiment. The device has been demonstrated to position targets repeatably within the Rayleigh range of the Scarlet laser system at The Ohio State University, where use of the device has provided a marked increase in ion yield and maximum energy.

Willis, Christopher↗

Neutron yield enhancement in laser-induced deuterium-deuterium fusion using a novel shaped target

Neutron yields have direct correlation with the energy of incident deuterons in experiments of laser deuterated target interaction [Roth et al., Phys. Rev. Lett. 110, 044802 (2013) and Higginson et al., Phys. Plasmas 18, 100703 (2011)], while deuterated plasma density is also an important parameter. Experiments at the Shenguang II laser facility have produced neutrons with energy of 2.45 MeV using d (d, n) He reaction. Deuterated foil target and K-shaped target were employed to study the influence of plasma density on neutron yields. Neutron yield generated by K-shaped target (nearly 10{sup 6}) was two times higher than by foil target because the K-shaped target results in higher density plasma. Interferometry and multi hydro-dynamics simulation confirmed the importance of plasma density for enhancement of neutron yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic effects of interaction of composite projectiles with targets

The process of high-speed impact of projectiles against targets of finite thickness is experimentally investigated. Medium-hard steel plates are used as targets. The objective of this research is to carry out a comparative analysis of dynamic effects of interaction of various types of projectiles with targets, such as characteristics of destruction of the target, the state of the projectile behind the target, and particularities of the after-penetration stream of fragments after the target has been pierced. The projectiles are made of composites on the basis of tungsten carbide obtained by caking and the SHS-technology. To compare effectiveness of composite projectiles steel projectiles are used. Their effectiveness was estimated in terms of the ballistic limit. High density projectiles obtained by means of the SHS-technology are shown to produce results comparable in terms of the ballistic limit with high-strength projectiles that contain tungsten received by caking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Staged Z-pinch modeling of high and low atomic number liners compressing deuterium targets using parameters of the Z pulsed power facility

The staged Z-pinch is a potentially transformative magneto-inertial fusion energy concept where a high atomic number liner implodes on a deuterium or deuterium-tritium target using multi-MA pulsed current. Over the past several years, this concept was studied experimentally on 1 MA facilities with argon or krypton gas puffs compressing a magnetized deuterium target. Consistent thermonuclear neutron yield of 1010 per shot was measured with krypton liners. In this paper, we investigate the fusion performance of deuterium targets of varying density undergoing compression with low (beryllium) and high atomic number liners (silver, tantalum) using parameters of the Z pulsed power facility. Silver and tantalum liners create strong shocks that preheat the target plasma above 100 eV and pile up liner material at the liner-target interface. The increased mass density at the interface creates strong ram pressure just before the pinch stagnation time. The target plasma is heated to 2–4 keV, in contrast to the < 0.5 kV temperature calculated for the beryllium case. The high atomic number liners produce neutron yield orders of magnitude higher than the yield from the low atomic number liner.

Ruskov, E. (ORCID:0000000336724580)↗

Approaching hydro-equivalent ignition in laser direct-drive via target design optimization using novel statistical modeling

Laser direct-drive offers significant advantages in terms of target simplicity, improved energy coupling, and large fuel masses over indirect drive. However, performance degradations from hydrodynamic and laser-plasma instabilities seeded and driven by the direct illumination pose limitations on the parameter space available for achieving ignition. In this paper, new design improvements are identified to forge a path forward for a hydro-equivalent ignition demonstration. The first is related to a new formulation of the statistical model (SM) used to accurately predict target performance directly from input parameters such as laser pulse shape and target specifications. This new SM formulation provides direct guidance on target dimensions and laser beam-to-target radius to achieve the highest fusion yield on the OMEGA laser. The second improvement comes from cooling the deuterium–tritium (DT) ice layer below the triple point right before shot time leading to lower DT vapor densities and higher convergence. Guided by these design improvements, a Bayesian optimization algorithm was used to design an implosion that is predicted to closely approach a Lawson triple product that hydrodynamically scales to ignition if equivalent laser–target coupling is achieved at laser energies typical of the National Ignition Facility.

Deuterium↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Radiation from a semiconductor target excited by an electron beam in a gas diode

Radiation from a semiconductor target excited by an electron beam in a gas-filled diode was investigated at different gas (air) pressures. Subnanosecond high-voltage pulses (up to 200 kV) were applied to the pointed cathode of the diode. The targets in the form of a 15 - 20-{mu}m-thick single-crystal CdS film with reflecting coatings forming an optical cavity and 0.7 - 1-mm-thick ZnSe plates were used. As the air pressure increased from 0.1 to 5 Torr, a decrease in the amplitude and duration of laser radiation pulses from the targets was observed. Lasing ({lambda} = 520 nm) of CdS targets terminated at pressures greater than 2.2 Torr. The laser pulse duration varied from 125 to 20 ps. The study of the dynamics of radiation from ZnSe targets ({lambda} = 460 nm) at atmospheric pressure showed that when the gap between the target and the electrodes was 0.2 - 1 mm thick, an intense near-surface glow was observed that consisted of a few pulses with the duration from 20 to 100 ps, caused by runaway electrons. Investigations showed that the runaway electrons may play an essential role in the excitation of semiconductors by subnanosecond high-voltage pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗