Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Triplet Transport to and Trapping by Acceptor End Groups on Conjugated Polyfluorene Chains

Triplet excited states created in polyfluorene (pF) molecules having average lengths up to 170 repeat units were transported to and captured by trap groups at the ends in less {approx}40 ns. Almost all of the triplets attached to the chains reached the trap groups, ruling out the presence of substantial numbers of defects that prevent transport. The transport yields a diffusion coefficient D of at least 3 x 10{sup -4} cm{sup 2} s{sup -1}, which is 30 times typical molecular diffusion and close to a value for triplet transport reported by Keller (J. Am. Chem. Soc.2011, 133, 11289-11298). The triplet states were created in solution by pulse radiolysis; time resolution was limited by the rate of attachment of triplets to the pF chains. Naphthylimide (NI) or anthraquinone (AQ) groups attached to the ends of the chains acted as traps for the triplets, although AQ would not have been expected to serve as a trap on the basis of triplet energies of the separate molecules. The depths of the NI and AQ triplet traps were determined by intermolecular triplet transfer equilibria and temperature dependence. The trap depths are shallow, just a few times thermal energy for both, so a small fraction of the triplets reside in the pF chains in equilibrium with the end-trapped triplets. Trapping by AQ appears to arise from charge transfer interactions between the pF chains and the electron-accepting AQ groups. Absorption bands of the end-trapped triplet states are similar in peak wavelength (760 nm) and shape to the 760 nm bands of triplets in the pF chains but have reduced intensities. When an electron donor, N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD), is added to the solution, it reacts with the end-trapped triplets to remove the 760 nm bands and to make the trapping irreversible. New bands created upon reaction with TMPD may be due to charge transfer states.

14 SOLAR ENERGY↗

Subnanosecond time-resolved x-ray measurements using an organic-inorganic perovskite scintillator

We have developed a fast x-ray detector using an organic-inorganic perovskite scintillator of phenethylamine lead bromide (PhE-PbBr{sub 4}). The scintillator had a dominant light emission with a fast decay time of 9.9 ns. An x-ray detector equipped with a 0.9-mm-thick PhE-PbBr{sub 4} crystal was used to detect nuclear resonant scattering in {sup 61}Ni (the first excited level: 67.41 keV; lifetime: 7.6 ns) by using synchrotron radiation. With this detector, we could successfully record the decaying gamma rays emitted from {sup 61}Ni with a time resolution of 0.7 ns (full width at half maximum) and a relatively high detection efficiency of 24%.

36 MATERIALS SCIENCE↗

RECOVERING A SHORT TIMESCALE SIGNAL FROM A PAIR OF LONG-DELAY VISARS

We introduce the benefits of analyzing VISAR data in the Fourier domain, particularly for recovering the short time scale signal component. In particular, by combining data from two VISARS having different long delays, we effectively reproduce the short time resolution ability of a short delay while retaining the superior sensitivity to absolute velocity of a long delay. Two different delays are generally desired, not only to untangle integer fringe skips, but to circumvent the fact that a single VISAR cannot record signal components of frequencies periodic with its reciprocal delay. Combining two different delays solves this. We treat the VISARs as linear filters and process and combine the signals in the Fourier domain with a direct equation, without any iteration of time-retarded equations. The technique is demonstrated with a numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement uncertainty and temporal resolution of Doppler global velocimetry using laser frequency modulation

A Doppler global velocimetry (DGV) measurement technique with a sinusoidal laser frequency modulation is presented for measuring velocity fields in fluid flows. A cesium absorption cell is used for the conversion of the Doppler shift frequency into a change in light intensity, which can be measured by a fiber coupled avalanche photo diode array. Because of a harmonic analysis of the detector element signals, no errors due to detector offset drifts occur and no reference detector array is necessary for measuring the scattered light power. Hence, large errors such as image misalignment errors and beam split errors are eliminated. Furthermore, the measurement system is also capable of achieving high measurement rates up to the modulation frequency (100 kHz) and thus opens new perspectives to multiple point investigations of instationary flows, e.g., for turbulence analysis. A fundamental measurement uncertainty analysis based on the theory of Cramer and Rao is given and validated by experimental results. The current relation between time resolution and measurement uncertainty, as well as further optimization strategies, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of thermal annealing on electron spin relaxation of beryllium-doped In{sub 0.8}Ga{sub 0.2}As{sub 0.45}P{sub 0.55} bulk

The effect of thermal annealing on the electron spin relaxation of beryllium-doped In{sub 0.8}Ga{sub 0.2}As{sub 0.45}P{sub 0.55} bulk was investigated by time-resolved spin-dependent pump and probe reflection measurement with a high time resolution of 200 fs. Three similar InGaAsP samples were examined one of which was annealed at 800 °C for 1 s, one was annealed at 700 °C for 1 s and the other was not annealed after crystal growth by molecular beam epitaxy. Although the carrier lifetimes of the 700 °C-annealed sample and the unannealed sample were similar, that of the 800 °C-annealed sample was extended to 11.6 (10.4) ns at 10 (300) K, which was more than two (four) times those of the other samples. However, interestingly the spin relaxation time of the 800 °C-annealed sample was found to be similar to those of the other two samples. Particularly at room temperature, the spin relaxation times are 143 ps, 147 ps, and 111 ps for the 800 °C-annealed sample, 700 °C-annealed sample, and the unannealed sample, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A prototype chopper for synchrotron time-resolved crystallographic measurements

A mechanical x-ray chopper has been designed to perform microsecond time-resolved crystallographic studies at the DIAMOND synchrotron I19 beamline. It consists of two asymmetric absorbers rotating synchronously at frequencies from 0 to 50 Hz in the same direction around a rotation axis that is parallel to the x-ray beam. The duration of the x-ray pulses produced by the chopper is determined by the relative phase between the two blades, which can be adjusted. The chopper system presented in this paper offers a time resolution suitable for conducting in situ experiments that afford the crystal structure of materials while in their transient (>10 {mu}s) photoactivated excited states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROSPECTS FOR THE DETECTION OF FAST RADIO BURSTS WITH THE MURCHISON WIDEFIELD ARRAY

Fast radio bursts (FRBs) are short timescale (<<1 s) astrophysical radio signals, presumed to be a signature of cataclysmic events of extragalactic origin. The discovery of six high-redshift events at ∼1400 MHz from the Parkes radio telescope suggests that FRBs may occur at a high rate across the sky. The Murchison Widefield Array (MWA) operates at low radio frequencies (80-300 MHz) and is expected to detect FRBs due to its large collecting area (∼2500 m{sup 2}) and wide field-of-view (FOV, ∼ 1000 deg{sup 2} at ν = 200 MHz). We compute the expected number of FRB detections for the MWA assuming a source population consistent with the reported detections. Our formalism properly accounts for the frequency-dependence of the antenna primary beam, the MWA system temperature, and unknown spectral index of the source population, for three modes of FRB detection: coherent; incoherent; and fast imaging. We find that the MWA's sensitivity and large FOV combine to provide the expectation of multiple detectable events per week in all modes, potentially making it an excellent high time resolution science instrument. Deviations of the expected number of detections from actual results will provide a strong constraint on the assumptions made for the underlying source population and intervening plasma distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPREHENSIVE ANALYSIS OF FERMI GAMMA-RAY BURST DATA. II. E{sub p} EVOLUTION PATTERNS AND IMPLICATIONS FOR THE OBSERVED SPECTRUM-LUMINOSITY RELATIONS

We present a time-resolved spectral analysis of 51 long and 11 short bright gamma-ray bursts (GRBs) observed with the Fermi/Gamma-Ray Burst Monitor, paying special attention to E{sub p} evolution within each burst. Among eight single-pulse long GRBs, five show an evolution from hard to soft, while three show intensity tracking. The multi-pulse long GRBs have more complicated patterns. Statistically, the hard-to-soft evolution pulses tend to be more asymmetric than the intensity-tracking ones, with a steeper rising wing than the falling wing. Short GRBs have E{sub p} tracking intensity exclusively with the 16 ms time-resolution analysis. We performed a simulation analysis and suggest that for at least some bursts, the late intensity-tracking pulses could be a consequence of overlapping hard-to-soft pulses. However, the fact that the intensity-tracking pattern exists in the first pulse of the multi-pulse long GRBs and some single-pulse GRBs, suggests that intensity tracking is an independent component, which may operate in some late pulses as well. For the GRBs with measured redshifts, we present a time-resolved E{sub p} - L{sub {gamma},iso} correlation analysis and show that the scatter of the correlation is comparable to that of the global Amati/Yonetoku relation. We discuss the predictions of various radiation models regarding E{sub p} evolution, as well as the possibility of a precessing jet in GRBs. The data pose a great challenge to each of these models, and hold the key to unveiling the physics behind GRB prompt emission.

79 ASTRONOMY AND ASTROPHYSICS↗

POWER SPECTRAL DENSITY OF FLUCTUATIONS OF BULK AND THERMAL SPEEDS IN THE SOLAR WIND

This paper analyzes solar wind power spectra of bulk and thermal speed fluctuations that are computed with a time resolution of 32 ms in the frequency range of 0.001–2 Hz. The analysis uses measurements of the Bright Monitor of the Solar Wind on board the Spektr-R spacecraft that are limited to 570 km s{sup 1} bulk speed. The statistics, based on more than 42,000 individual spectra, show that: (1) the spectra of bulk and thermal speeds can be fitted by two power-law segments; (2) despite their large variations, the parameters characterizing frequency spectrum fits computed on each particular time interval are very similar for both quantities; (3) the median slopes of the bulk and thermal speeds of the segment attributed to the MHD scale are 1.43 and 1.38, respectively, whereas they are 3.08 and 2.43 in the kinetic range; (4) the kinetic range slopes of bulk and thermal speed spectra become equal when either the ion density or magnetic field strength are high; (5) the break between MHD and kinetic scales seems to be controlled by the ion β parameter; (6) the best scaling parameter for bulk and thermal speed variations is a sum of the inertial length and proton thermal gyroradius; and (7) the above conclusions can be applied to the density variations if the background magnetic field is very low.

79 ASTRONOMY AND ASTROPHYSICS↗

Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides

Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.

36 MATERIALS SCIENCE↗

Ultrashort electron pulses as a four-dimensional diagnosis of plasma dynamics

We report an ultrafast electron imaging system for real-time examination of ultrafast plasma dynamics in four dimensions. It consists of a femtosecond pulsed electron gun and a two-dimensional single electron detector. The device has an unprecedented capability of acquiring a high-quality shadowgraph image with a single ultrashort electron pulse, thus permitting the measurement of irreversible processes using a single-shot scheme. In a prototype experiment of laser-induced plasma of a metal target under moderate pump intensity, we demonstrated its unique capability of acquiring high-quality shadowgraph images on a micron scale with a-few-picosecond time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron–positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 10{sup 21} s{sup −1}, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prompt optical observations of GRBs with 'Pi of the Sky' system

The 'Pi of the Sky' prototype apparatus observed prompt optical emission from extremely bright GRB080319B since the very beginning of the gamma emission. The burst occurred at redshift z = 0.937 and set the record of optical luminosity reaching 5.3 mag. The position of the burst was observed before, during and after the explosion by several telescopes and unprecedented coverage of optical light curve has been achieved. The combination of these unique optical data with simultaneous gamma-ray observations provides a powerful diagnostic tool for the physics of the GRB explosion within seconds of its start. The 'Pi of the Sky' prototype, working since 2004 in Las Campanas Observatory in Chile, consists of 2 cameras observing same 20 deg. x 20 deg. fields in the sky with time resolution of 10 seconds. The prototype reacts to GCN alerts, but it has also its own algorithm for identification of optical flashes. The final system covering field of view of Swift or Fermi satellite will consist of 2 arrays of 16 cameras installed in a distance of about 100 km. The system is currently under construction. It will be a powerful tool for early optical observations of GRBs, allowing for optical observation of GRBs before, during and after the gamma emission. With the on-line data analysis in real time, it will identify short optical flashes autonomously and will be able to distribute this information among the community. In this contribution the general idea of the final version of the experiment and the most interesting results from the prototype are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-mode fiber, velocity interferometry

In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Impacts of Climate Change Mitigation Technologies on Power Grids

This paper describes a modeling approach that simulate the impacts of different climate change mitigation technologies on power grids for power system planning purposes. Because the historical data is less credible when new technologies are being deployed to the system, it is then critical to model them to address their impacts. This paper illustrated how to integrate modeling results obtained from different modeling tools to give a reasonable forecast of the future. Building simulation tools, distribution power grid modeling tools, and power system planning tools are used to model and aggregate the impacts from the end-use to the system level. Electricity generation, production cost, emission, and transmission congestions are used to quantify the influence of different mitigation technologies. Modeling results have shown that the cross-discipline modeling approach provided the modeler with the necessary time resolution and input details to address the variables that influence the modeling results. Different modeling issues are also addressed in the paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quick measurement of crystal truncation rod profiles in simultaneous multi-wavelength dispersive mode

To conduct time-resolved measurements in the wide momentum transfer (q = 4{pi} sin{theta}/{lambda}, {theta}: the glancing angle of the x-ray beam, {lambda}: x-ray wavelength) range of interest, we developed a method that can simultaneously measure the whole profile of x-ray diffraction and crystal truncation rod scattering of interest with no need of rotation of the specimen, detector, and monochromator crystal during the measurement. With a curved crystal polychromator (Si 111 diffraction), a horizontally convergent x-ray beam having a one-to-one correlation between wavelength (energy: 16.24-23.0 keV) and direction is produced. The convergent x-ray beam components of different wavelengths are incident on the specimen in a geometry where {theta} is the same for all the x-ray components and are diffracted within corresponding vertical scattering planes by a specimen ([GaAs(12ML)/AlAs(8 ML)]{sub 50} on GaAs(001) substrate) placed at the focal point. Although {theta} is the same for all the directions, q continuously varies because {lambda} changes as a function of direction. The normalized horizontal intensity distribution across the beam, as measured using a two-dimensional pixel array detector downstream of the specimen, represents the reflectivity curve profile both near to and far from the Bragg point. As for the crystal truncation rod scattering around the 002 reflection, the diffraction profile from the Bragg peak down to reflectivity of 1.0 x 10{sup -9} was measured with a sufficient data collection time (1000-2000 s). With data collection times of 100, 10, 1.0, and 0.1 s, profiles down to a reflectivity of {approx}6 x 10{sup -9}, {approx}2 x 10{sup -8}, {approx}8 x 10{sup -8}, and {approx}8 x 10{sup -7} were measured, respectively. To demonstrate the time-resolving capability of the system, reflectivity curves were measured with time resolutions of 1.0 s while rotating the specimen. We have also measured the diffraction profile around the 113 reflection in the non-specular reflection geometry.

36 MATERIALS SCIENCE↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗