Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Symmetry tuning via controlled crossed-beam energy transfer on the National Ignition Facility

The hohlraum energetics experimental campaign started in the summer of 2009 on the national Ignition Facility (NIF) (cf. N. Meezan et al., Phys. Plasmas, this issue). These experiments have demonstrated controlled crossed-beam transfer as an efficient and robust tool to tune the implosion symmetry of ignition capsules. A new linear model calculating crossed-beam energy transfer between cones of beams on the NIF has been developed. The model has been applied to the emulator targets shot for the National Ignition Campaign in 2009. These targets have no lip liner at the laser entrance holes, which reduces the amount of energy transfer between laser beams and requires a larger wavelength separation between the cones of laser beams in order to achieve the best symmetry (with no net transfer between the inner and outer cones). A good agreement is found between the calculations and measurements; remaining discrepancies can be explained by a 10% error in modeling the flow at the laser entrance hole of ignitions hohlraums.

42 ENGINEERING↗

MULTI-KEV X-RAY YIELDS FROM HIGH-Z GAS TARGETS FIELDED AT OMEGA

The authors report on modeling of x-ray yield from gas-filled targets shot at the OMEGA laser facility. The OMEGA targets were 1.8 mm long, 1.95 mm in diameter Be cans filled with either a 50:50 Ar:Xe mixture, pure Ar, pure Kr or pure Xe at {approx} 1 atm. The OMEGA experiments heated the gas with 20 kJ of 3{omega} ({approx} 350 nm) laser energy delivered in a 1 ns square pulse. the emitted x-ray flux was monitored with the x-ray diode based DANTE instruments in the sub-keV range. Two-dimensional x-ray images (for energies 3-5 keV) of the targets were recorded with gated x-ray detectors. The x-ray spectra were recorded with the HENWAY crystal spectrometer at OMEGA. Predictions are 2D r-z cylindrical with DCA NLTE atomic physics. Models generally: (1) underpredict the Xe L-shell yields; (2) overpredict the Ar K-shell yields; (3) correctly predict the Xe thermal yields; and (4) greatly underpredict the Ar thermal yields. However, there are spreads within the data, e.g. the DMX Ar K-shell yields are correctly predicted. The predicted thermal yields show strong angular dependence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an autonomous video rendezvous and docking system, phase 2

The critical elements of an autonomous video rendezvous and docking system were built and used successfully in a physical laboratory simulation. The laboratory system demonstrated that a small, inexpensive electronic package and a flight computer of modest size can analyze television images to derive guidance information for spacecraft. In the ultimate application, the system would use a docking aid consisting of three flashing lights mounted on a passive target spacecraft. Television imagery of the docking aid would be processed aboard an active chase vehicle to derive relative positions and attitudes of the two spacecraft. The demonstration system used scale models of the target spacecraft with working docking aids. A television camera mounted on a 6 degree of freedom (DOF) simulator provided imagery of the target to simulate observations from the chase vehicle. A hardware video processor extracted statistics from the imagery, from which a computer quickly computed position and attitude. Computer software known as a Kalman filter derived velocity information from position measurements.

Tietz, J. C.↗

Involved field radiation for Hodgkin's lymphoma: The actual dose to breasts in close proximity

To decrease the risk of late toxicities in Hodgkin's lymphoma (HL) patients treated with radiation therapy (RT) (HL), involved field radiation therapy (IFRT) has largely replaced the extended fields. To determine the out-of-field dose delivered from a typical IFRT to surrounding critical structures, we measured the dose at various points in an anthropomorphic phantom. The phantom is divided into 1-inch-thick slices with the ability to insert TLDs at 3-cm intervals grid spacing. Two treatment fields were designed, and a total of 45 TLDs were placed (equally spaced) at the margin of the each of the 2 radiation fields. After performing a computed tomography simulation, 2 treatment plans targeting the mediastinum, a typical treatment field in patients with early stage HL, were generated. A total dose of 3060 cGy was delivered to the gross tumor volume for each field consecutively. The highest measured dose detected at 1 cm from the field edge in the planning target volume was 496 cGy, equivalent to 16% of the isocentric dose. The dose dropped significantly with increasing distance from the field edge. It ranged from 1.1-3.9% of the isocentric dose at a distance of 3.2-4 cm to <1.6% at a distance of >6 cm. Although the computer treatment planning system (CTPS) frequently underestimated the dose delivered, the difference in dose between measured and generated by CTPS was <2.5% in 90 positions measured. The collateral dose of radiation to breasts from IFRT is minimal. The out-of-field dose, although mildly underestimated by CTPS, becomes insignificant at >3 cm from the field edge of the radiation field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decision support for integrated water-energy planning.

Currently, electrical power generation uses about 140 billion gallons of water per day accounting for over 39% of all freshwater withdrawals thus competing with irrigated agriculture as the leading user of water. Coupled to this water use is the required pumping, conveyance, treatment, storage and distribution of the water which requires on average 3% of all electric power generated. While water and energy use are tightly coupled, planning and management of these fundamental resources are rarely treated in an integrated fashion. Toward this need, a decision support framework has been developed that targets the shared needs of energy and water producers, resource managers, regulators, and decision makers at the federal, state and local levels. The framework integrates analysis and optimization capabilities to identify trade-offs, and 'best' alternatives among a broad list of energy/water options and objectives. The decision support framework is formulated in a modular architecture, facilitating tailored analyses over different geographical regions and scales (e.g., national, state, county, watershed, NERC region). An interactive interface allows direct control of the model and access to real-time results displayed as charts, graphs and maps. Ultimately, this open and interactive modeling framework provides a tool for evaluating competing policy and technical options relevant to the energy-water nexus.

13 HYDRO ENERGY↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

VITAL NMR: Using Chemical Shift Derived Secondary Structure Information for a Limited Set of Amino Acids to Assess Homology Model Accuracy

Homology modeling is a powerful tool for predicting protein structures, whose success depends on obtaining a reasonable alignment between a given structural template and the protein sequence being analyzed. In order to leverage greater predictive power for proteins with few structural templates, we have developed a method to rank homology models based upon their compliance to secondary structure derived from experimental solid-state NMR (SSNMR) data. Such data is obtainable in a rapid manner by simple SSNMR experiments (e.g., (13)C-(13)C 2D correlation spectra). To test our homology model scoring procedure for various amino acid labeling schemes, we generated a library of 7,474 homology models for 22 protein targets culled from the TALOS+/SPARTA+ training set of protein structures. Using subsets of amino acids that are plausibly assigned by SSNMR, we discovered that pairs of the residues Val, Ile, Thr, Ala and Leu (VITAL) emulate an ideal dataset where all residues are site specifically assigned. Scoring the models with a predicted VITAL site-specific dataset and calculating secondary structure with the Chemical Shift Index resulted in a Pearson correlation coefficient (-0.75) commensurate to the control (-0.77), where secondary structure was scored site specifically for all amino acids (ALL 20) using STRIDE. This method promises to accelerate structure procurement by SSNMR for proteins with unknown folds through guiding the selection of remotely homologous protein templates and assessing model quality.

59 BASIC BIOLOGICAL SCIENCES↗

An integrated 6 MV linear accelerator model from electron gun to dose in a water tank

Purpose: The details of a full simulation of an inline side-coupled 6 MV linear accelerator (linac) from the electron gun to the target are presented. Commissioning of the above simulation was performed by using the derived electron phase space at the target as an input into Monte Carlo studies of dose distributions within a water tank and matching the simulation results to measurement data. This work is motivated by linac-MR studies, where a validated full linac simulation is first required in order to perform future studies on linac performance in the presence of an external magnetic field. Methods: An electron gun was initially designed and optimized with a 2D finite difference program using Child's law. The electron gun simulation served as an input to a 6 MV linac waveguide simulation, which consisted of a 3D finite element radio-frequency field solution within the waveguide and electron trajectories determined from particle dynamics modeling. The electron gun design was constrained to match the cathode potential and electron gun current of a Varian 600C, while the linac waveguide was optimized to match the measured target current. Commissioning of the full simulation was performed by matching the simulated Monte Carlo dose distributions in a water tank to measured distributions. Results: The full linac simulation matched all the electrical measurements taken from a Varian 600C and the commissioning process lead to excellent agreements in the dose profile measurements. Greater than 99% of all points met a 1%/1mm acceptance criterion for all field sizes analyzed, with the exception of the largest 40x40 cm{sup 2} field for which 98% of all points met the 1%/1mm acceptance criterion and the depth dose curves matched measurement to within 1% deeper than 1.5 cm depth. The optimized energy and spatial intensity distributions, as given by the commissioning process, were determined to be non-Gaussian in form for the inline side-coupled 6 MV linac simulated. Conclusions: An integrated simulation of an inline side-coupled 6 MV linac has been completed and benchmarked matching all electrical and dosimetric measurements to high accuracy. The results showed non-Gaussian spatial intensity and energy distributions for the linac modeled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced laser ion acceleration from mass-limited foils

This paper reports on simulations of solid mass-limited targets (MLT) via electrodynamic two-dimensional, three velocity component particle-in-cell simulations. The interaction with long (300 fs) high intensity (10{sup 20} W/cm{sup 2}) laser pulses with targets of diameter down to 1 {mu}m is described in detail with respect to electron dynamics and proton and ion acceleration. Depending on the foil diameter, different effects consecutively arise. Electrons laterally recirculate within the target, smoothening the target rear accelerating sheath and increasing the hot electron density and temperature. Our results suggest that the most significant ion energy enhancement should be expected for MLT with diameter below the laser focal spot size. The spread of energetic protons is decreased for medium sized foils while it is greatly increased for foils of size near the focal spot size.

43 PARTICLE ACCELERATORS↗

Numerical study on pressure wave propagation in a mercury loop

On-beam tests were carried out at the Los Alamos Neutron Science Center Weapons Neutron Research (LANSCE WNR) facility in June 2005 to investigate pressure wave mitigation in mercury targets for the MW-class spallation neutron sources under international collaboration between US Spallation Neutron Source (SNS) and Japanese Spallation Neutron Source (JSNS). A mercury loop was used for the target, a so-called In-Beam Bubbling Test Loop (IBBTL). The loop consists of the rectangular pipe of 25 mm x 50 mm^2 in cross section, 1.5 mm in wall thickness and 2 m in total length approximately. The SNS team set 8 strain sensors on the pipe wall to measure the strain propagation caused by the pressure wave. The maximum strain appeared at 350 mm apart from the proton-bombarded point at 5.5 ms after the proton bombardment. It is known that the propagation velocity of the pressure wave in mercury is ca. 1500 m/s and that of the stress wave in stainless steel is ca. 5000 m/s. However, the apparent wave propagation velocity in the IBBTL was lower than those velocities and was observed to be 65 m/s. Numerical analysis was carried out to understand the strain propagation in the pipe wall of the IBBTL. Numerical results showed that the maximum strain at 350 mm apart from the beam spot appeared at 5.5 ms after proton bombardment in good agreement with experimental results.

mercury↗

Advanced Simulation Capability for Environmental Management: Development and Demonstrations - 12532

The U.S. Department of Energy Office of Environmental Management (EM), Technology Innovation and Development is supporting development of the Advanced Simulation Capability for Environmental Management (ASCEM). ASCEM is a state-of-the-art scientific tool and approach for understanding and predicting contaminant fate and transport in natural and engineered systems. The modular and open source high-performance computing tool facilitates integrated approaches to modeling and site characterization that enable robust and standardized assessments of performance and risk for EM cleanup and closure activities. The ASCEM project continues to make significant progress in development of capabilities, which are organized into Platform and Integrated Tool-sets and a High-Performance Computing Multi-process Simulator. The Platform capabilities target a level of functionality to allow end-to-end model development, starting with definition of the conceptual model and management of data for model input. The High-Performance Computing capabilities target increased functionality of process model representations, tool-sets for interaction with Platform, and verification and model confidence testing. The new capabilities are demonstrated through working groups, including one focused on the Hanford Site Deep Vadose Zone. The ASCEM program focused on planning during the first year and executing a prototype tool-set for an early demonstration of individual components. Subsequently, ASCEM has focused on developing and demonstrating an integrated set of capabilities, making progress toward a version of the capabilities that can be used to engage end users. Demonstration of capabilities continues to be implemented through working groups. Three different working groups, one focused on EM problems in the deep vadose zone, another investigating attenuation mechanisms for metals and radionuclides, and a third focusing on waste tank performance assessment, continue to make progress. The project experience has been that the working group mechanism continues to be useful for helping guide development and prepare the capabilities for end users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular Mechanism of Selectivity among G Protein-Coupled Receptor Kinase 2 Inhibitors

G protein-coupled receptors (GPCRs) are key regulators of cell physiology and control processes ranging from glucose homeostasis to contractility of the heart. A major mechanism for the desensitization of activated GPCRs is their phosphorylation by GPCR kinases (GRKs). Overexpression of GRK2 is strongly linked to heart failure, and GRK2 has long been considered a pharmaceutical target for the treatment of cardiovascular disease. Several lead compounds developed by Takeda Pharmaceuticals show high selectivity for GRK2 and therapeutic potential for the treatment of heart failure. To understand how these drugs achieve their selectivity, we determined crystal structures of the bovine GRK2-G{beta}{gamma} complex in the presence of two of these inhibitors. Comparison with the apoGRK2-G{beta}{gamma} structure demonstrates that the compounds bind in the kinase active site in a manner similar to that of the AGC kinase inhibitor balanol. Both balanol and the Takeda compounds induce a slight closure of the kinase domain, the degree of which correlates with the potencies of the inhibitors. Based on our crystal structures and homology modeling, we identified five amino acids surrounding the inhibitor binding site that we hypothesized could contribute to inhibitor selectivity. However, our results indicate that these residues are not major determinants of selectivity among GRK subfamilies. Rather, selectivity is achieved by the stabilization of a unique inactive conformation of the GRK2 kinase domain.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-188: Commission of World 1st Commercial Compact PBS Proton System

Purpose: ProteusONE is the 1st commercial compact PBS proton system with an upstream scanning gantry and C230 cyclotron. We commissioned XiO and Raystation TPS simultaneously. This is a summary of beam data collection, modeling, and verification and comparison without range shiter for this unique system with both TPS. Methods: Both Raystation and XiO requires the same measurements data: (i) integral depth dose(IDDs) of single central spot measured in water tank; (ii) absolute dose calibration measured at 2cm depth of water with mono-energetic 10×10 cm2 field with spot spacing 4mm, 1MU per spot; and (iii) beam spot characteristics in air at 0cm and ± 20cm away from ISO. To verify the beam model for both TPS, same 15 cube plans were created to simulate different treatment sites, target volumes and positions. PDDs of each plan were measured using a Multi-layer Ionization Chamber(MLIC), absolute point dose verification were measured using PPC05 in water tank and patient-specific QA were measured using MatriXX PT, a 2D ion chamber array. Results: All the point dose measurements at midSOBP were within 2% for both XiO and Raystation. However, up to 5% deviations were observed in XiO’s plans at shallow depth while within 2% in Raystation plans. 100% of the ranges measured were within 1 mm with maximum deviation of 0.5 mm. 20 patient specific plan were generated and measured in 3 planes (distal, proximal and midSOBP) in Raystation. The average of gamma index is 98.7%±3% with minimum 94% Conclusions: Both TPS were successfully commissioned and can be safely deployed for clinical use for ProteusONE. Based on our clinical experience in PBS planning, user interface, function and workflow, we preferably use Raystation as our main clinical TPS. Gamma Index >95% at 3%/3 mm criteria is our institution action level for patient specific plan QAs.

60 APPLIED LIFE SCIENCES↗

Virtual HDR{sup SM} CyberKnife Treatment for Localized Prostatic Carcinoma: Dosimetry Comparison With HDR Brachytherapy and Preliminary Clinical Observations

Background: We tested our ability to approximate the dose (38 Gy), fractionation (four fractions), and distribution of high-dose-rate (HDR) brachytherapy for prostate cancer with CyberKnife (CK) stereotactic body radiotherapy (SBRT) plans. We also report early clinical observations of CK SBRT treatment. Methods and Materials: Ten patients were treated with CK. For each CK SBRT plan, an HDR plan was designed using common contour sets and simulated HDR catheters. Planning target volume coverage, intraprostatic dose escalation, and urethra, rectum, and bladder exposure were compared. Results: Planning target volume coverage by the prescription dose was similar for CK SBRT and HDR plans, whereas percent of volume of interest receiving 125% of prescribed radiation dose (V125) and V150 values were higher for HDR, reflecting higher doses near HDR source dwell positions. Urethra dose comparisons were lower for CK SBRT in 9 of 10 cases, suggesting that CK SBRT may more effectively limit urethra dose. Bladder maximum point doses were higher with HDR, but bladder dose falloff beyond the maximum dose region was more rapid with HDR. Maximum rectal wall doses were similar, but CK SBRT created sharper rectal dose falloff beyond the maximum dose region. Second CK SBRT plans, constructed by equating urethra radiation dose received by point of maximum exposure of volume of interest to the HDR plan, significantly increased V125 and V150. Clinically, 4-month post-CK SBRT median prostate-specific antigen levels decreased 86% from baseline. Acute toxicity was primarily urologic and returned to baseline by 2 months. Acute rectal morbidity was minimal and transient. Conclusions: It is possible to construct CK SBRT plans that closely recapitulate HDR dosimetry and deliver the plans noninvasively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric comparison of patient setup strategies in stereotactic body radiation therapy for lung cancer

Purpose: In this work, the authors retrospectively compared the accumulated dose over the treatment course for stereotactic body radiation therapy (SBRT) of lung cancer for three patient setup strategies. Methods: Ten patients who underwent lung SBRT were selected for this study. At each fraction, patients were immobilized using a vacuum cushion and were CT scanned. Treatment plans were performed on the simulation CT. The planning target volume (PTV) was created by adding a 5-mm uniform margin to the internal target volume derived from the 4DCT. All plans were normalized such that 99% of the PTV received 60 Gy. The plan parameters were copied onto the daily CT images for dose recalculation under three setup scenarios: skin marker, bony structure, and soft tissue based alignments. The accumulated dose was calculated by summing the dose at each fraction along the trajectory of a voxel over the treatment course through deformable image registration of each CT with the planning CT. The accumulated doses were analyzed for the comparison of setup accuracy. Results: The tumor volume receiving 60 Gy was 91.7 {+-} 17.9%, 74.1 {+-} 39.1%, and 99.6 {+-} 1.3% for setup using skin marks, bony structures, and soft tissue, respectively. The isodose line covering 100% of the GTV was 55.5 {+-} 7.1, 42.1 {+-} 16.0, and 64.3 {+-} 7.1 Gy, respectively. The corresponding average biologically effective dose of the tumor was 237.3 {+-} 29.4, 207.4 {+-} 61.2, and 258.3 {+-} 17.7 Gy, respectively. The differences in lung biologically effective dose, mean dose, and V20 between the setup scenarios were insignificant. Conclusions: The authors' results suggest that skin marks and bony structure are insufficient for aligning patients in lung SBRT. Soft tissue based alignment is needed to match the prescribed dose delivered to the tumors.

60 APPLIED LIFE SCIENCES↗

An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion

Purpose: In quantitative myocardial CT perfusion imaging, beam hardening effect due to dense bone and high concentration iodinated contrast agent can result in visible artifacts and inaccurate CT numbers. In this paper, an efficient polyenergetic Simultaneous Algebraic Reconstruction Technique (pSART) was presented to eliminate the beam hardening artifacts and to improve the CT quantitative imaging ability. Methods: Our algorithm made threea priori assumptions: (1) the human body is composed of several base materials (e.g., fat, breast, soft tissue, bone, and iodine); (2) images can be coarsely segmented to two types of regions, i.e., nonbone regions and noniodine regions; and (3) each voxel can be decomposed into a mixture of two most suitable base materials according to its attenuation value and its corresponding region type information. Based on the above assumptions, energy-independent accumulated effective lengths of all base materials can be fast computed in the forward ray-tracing process and be used repeatedly to obtain accurate polyenergetic projections, with which a SART-based equation can correctly update each voxel in the backward projecting process to iteratively reconstruct artifact-free images. This approach effectively reduces the influence of polyenergetic x-ray sources and it further enables monoenergetic images to be reconstructed at any arbitrarily preselected target energies. A series of simulation tests were performed on a size-variable cylindrical phantom and a realistic anthropomorphic thorax phantom. In addition, a phantom experiment was also performed on a clinical CT scanner to further quantitatively validate the proposed algorithm. Results: The simulations with the cylindrical phantom and the anthropomorphic thorax phantom showed that the proposed algorithm completely eliminated beam hardening artifacts and enabled quantitative imaging across different materials, phantom sizes, and spectra, as the absolute relative errors were reduced from [−7.5%, 12.1%] for SART to [−0.1%, 0.1%] for pSART. When using low kVp spectra and high reference energies, pSART also showed improved reconstruction efficiency in terms of convergence speed compared to the conventional SART algorithm. The phantom experiment on a clinical CT scanner indicated that the quantitative advantage of pSART is realizable in experimental CT acquisition, as the absolute relative errors across material inserts were less than 0.4%. Conclusions: By incorporatinga priori information (material attenuation coefficients, x-ray source spectrum, and region type information) into the reconstruction process, the proposed pSART algorithm could effectively eliminate beam hardening artifacts, reconstruct the accurate attenuation coefficients for precise quantitative imaging, and accelerate the reconstruction process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VERA 3.3 Release Notes

The Virtual Environment for Reactor Applications components included in this distribution include selected computational tools and supporting infrastructure that solve neutronics, thermal-hydraulics, fuel performance, and coupled neutronics-thermal hydraulics-fuel performance problems. The infrastructure components provide a simplified common user input capability and provide for the physics integration with data transfer and coupled-physics iterative solution algorithms. Neutronics analysis can be performed for 2D lattices, 2D core and 3D core problems for pressurized water reactor geometries that can be used to calculate criticality and fission rate distributions by pin for input fuel compositions. Two neutronics capabilities are provided in this distribution including MPACT (from the University of Michigan) that supports 2D lattices and Insilico (from Oak Ridge National Laboratory) that supports 2D lattices, 2D core planes, and 3D core geometries. Both codes include integrated cross section capabilities that provide problem-specific cross sections for the problems defined. A thermal-hydraulics capability is provided with CTF (an updated version of the COBRA-TF code developed by the Pennsylvania State University) that allows thermal-hydraulics analyses for single and multiple assemblies using the simplified VERA common input. This distribution also includes an initial coupled neutronics/thermal-hydraulics capability to allow calculations of single assemblies using Insilico or MPACT coupled with CTF. The VERA fuel rod performance subcomponent BISON-CASL calculates, on a 3D basis, fuel rod temperature, fuel rod internal pressure, free gas volume, clad integrity and fuel rod waterside diameter. These capabilities allow simulation of power cycling, fuel conditioning and deconditioning, high burnup performance, power uprate scoping studies, and accident performance. Specifically targeted at VERA’s core simulator functionality (VERA-CS), the existing VERA subchannel-neutronics capability based on CTF and Insilico has been extended to use the axisymmetric 2D R-Z fuel rod modeling functionality of BISON-CASL to produce a three-way coupled neutronics, thermal-hydraulics and fuel performance capability known as Tiamat. This distribution is intended to be used for testing and evaluation of the released components of VERA. Testing within CASL has focused specifically on Westinghouse four-loop reactor geometries and conditions with example problems included in the distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nucleosynthesis driven by Coulomb explosion of nanodroplets

This paper presents a computational and theoretical study of the yields for the {sup 12}C(p,{gamma}){sup 13}N and {sup 12}C(d,n){sup 13}N nucleosynthesis reactions driven by high-energy (MeV) Coulomb explosion (CE) of (CH{sub 4}){sub n} and (CD{sub 4}){sub n} nanodroplets (n=10{sup 4}-10{sup 7}, radii R{sub 0}=100-500 A) in ultraintense near-infrared Gaussian laser fields (peak intensities I{sub M}=10{sup 18}-10{sup 19} W cm{sup -2}, pulse length {tau}=25 fs). Efficient nucleosynthesis with {sup 12}C nuclei requires the production of protons and deuterons in the energy range of 0.5-2.0 MeV, which is accomplished by CE of nanodroplets. The energy distributions of the nuclei were obtained from scaled molecular dynamics simulations and were utilized to calculate the energy averaged cross sections and the reaction yields for nucleosynthesis. Two distinct reaction modes were established pertaining to reactions inside the plasma filament volume (IF), and to reactions outside the plasma filament volume (OF). The dominating contribution to the total yields originates from the OF mode. The time resolved {gamma}-ray emission for {sup 12}C(p,{gamma}){sup 13}N will be exhibited in distinct time intervals of 2-100 ps for the OF mode and of 65 fs-3 ps for the IF mode. Estimates of the yields were provided by incorporating the effects of nanodroplet size distributions that result in a slow size dependence of the yields in the range R{sub 0}>250 A, and the effects of laser intensity attenuation in an assembly of nanodroplets that result in the decrease of the OF and IF yields due to the decrease of the effective plasma filament volume. For 400 A nanodroplets at I{sub M}=4x10{sup 18}-10{sup 19} W cm{sup -2}, under realistic experimental conditions, the {sup 12}C(p,{gamma}){sup 13}N nucleosynthesis driven by CE of (CH{sub 4}){sub n} nanodroplets is characterized by a yield (per laser pulse) of {approx}100, while the yield for the {sup 12}C(d,n){sup 13}N nucleosynthesis driven by CE of (CD{sub 4}){sub n} clusters is {approx}9x10{sup 4}. Table-top nucleosynthesis driven by nanodroplet CE is amenable to experimental observation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗