Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Staged Z-pinch modeling of high and low atomic number liners compressing deuterium targets using parameters of the Z pulsed power facility

The staged Z-pinch is a potentially transformative magneto-inertial fusion energy concept where a high atomic number liner implodes on a deuterium or deuterium-tritium target using multi-MA pulsed current. Over the past several years, this concept was studied experimentally on 1 MA facilities with argon or krypton gas puffs compressing a magnetized deuterium target. Consistent thermonuclear neutron yield of 1010 per shot was measured with krypton liners. In this paper, we investigate the fusion performance of deuterium targets of varying density undergoing compression with low (beryllium) and high atomic number liners (silver, tantalum) using parameters of the Z pulsed power facility. Silver and tantalum liners create strong shocks that preheat the target plasma above 100 eV and pile up liner material at the liner-target interface. The increased mass density at the interface creates strong ram pressure just before the pinch stagnation time. The target plasma is heated to 2–4 keV, in contrast to the < 0.5 kV temperature calculated for the beryllium case. The high atomic number liners produce neutron yield orders of magnitude higher than the yield from the low atomic number liner.

Ruskov, E. (ORCID:0000000336724580)↗

Approaching hydro-equivalent ignition in laser direct-drive via target design optimization using novel statistical modeling

Laser direct-drive offers significant advantages in terms of target simplicity, improved energy coupling, and large fuel masses over indirect drive. However, performance degradations from hydrodynamic and laser-plasma instabilities seeded and driven by the direct illumination pose limitations on the parameter space available for achieving ignition. In this paper, new design improvements are identified to forge a path forward for a hydro-equivalent ignition demonstration. The first is related to a new formulation of the statistical model (SM) used to accurately predict target performance directly from input parameters such as laser pulse shape and target specifications. This new SM formulation provides direct guidance on target dimensions and laser beam-to-target radius to achieve the highest fusion yield on the OMEGA laser. The second improvement comes from cooling the deuterium–tritium (DT) ice layer below the triple point right before shot time leading to lower DT vapor densities and higher convergence. Guided by these design improvements, a Bayesian optimization algorithm was used to design an implosion that is predicted to closely approach a Lawson triple product that hydrodynamically scales to ignition if equivalent laser–target coupling is achieved at laser energies typical of the National Ignition Facility.

Deuterium↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Radiation from a semiconductor target excited by an electron beam in a gas diode

Radiation from a semiconductor target excited by an electron beam in a gas-filled diode was investigated at different gas (air) pressures. Subnanosecond high-voltage pulses (up to 200 kV) were applied to the pointed cathode of the diode. The targets in the form of a 15 - 20-{mu}m-thick single-crystal CdS film with reflecting coatings forming an optical cavity and 0.7 - 1-mm-thick ZnSe plates were used. As the air pressure increased from 0.1 to 5 Torr, a decrease in the amplitude and duration of laser radiation pulses from the targets was observed. Lasing ({lambda} = 520 nm) of CdS targets terminated at pressures greater than 2.2 Torr. The laser pulse duration varied from 125 to 20 ps. The study of the dynamics of radiation from ZnSe targets ({lambda} = 460 nm) at atmospheric pressure showed that when the gap between the target and the electrodes was 0.2 - 1 mm thick, an intense near-surface glow was observed that consisted of a few pulses with the duration from 20 to 100 ps, caused by runaway electrons. Investigations showed that the runaway electrons may play an essential role in the excitation of semiconductors by subnanosecond high-voltage pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Genomic discovery of an evolutionarily programmed modality for small-molecule targeting of an intractable protein surface

The vast majority of intracellular protein targets are refractory toward small-molecule therapeutic engagement, and additional therapeutic modalities are needed to overcome this deficiency. Here, the identification and characterization of a natural product, WDB002, reveals a therapeutic modality that dramatically expands the currently accepted limits of druggability. WDB002, in complex with the FK506-binding protein (FKBP12), potently and selectively binds the human centrosomal protein 250 (CEP250), resulting in disruption of CEP250 function in cells. The recognition mode is unprecedented in that the targeted domain of CEP250 is a coiled coil and is topologically featureless, embodying both a structural motif and surface topology previously considered on the extreme limits of “undruggability” for an intracellular target. Structural studies reveal extensive protein–WDB002 and protein–protein contacts, with the latter being distinct from those seen in FKBP12 ternary complexes formed by FK506 and rapamycin. Outward-facing structural changes in a bound small molecule can thus reprogram FKBP12 to engage diverse, otherwise “undruggable” targets. The flat-targeting modality demonstrated here has the potential to expand the druggable target range of small-molecule therapeutics. As CEP250 was recently found to be an interaction partner with the Nsp13 protein of the SARS-CoV-2 virus that causes COVID-19 disease, it is possible that WDB002 or an analog may exert useful antiviral activity through its ability to form high-affinity ternary complexes containing CEP250 and FKBP12.

59 BASIC BIOLOGICAL SCIENCES↗

Structural basis for Clostridium perfringens enterotoxin targeting of claudins at tight junctions in mammalian gut

The bacterium Clostridium perfringens causes severe, sometimes lethal gastrointestinal disorders in humans, including enteritis and enterotoxemia. Type F strains produce an enterotoxin (CpE) that causes the third most common foodborne illness in the United States. CpE induces gut breakdown by disrupting barriers at cell–cell contacts called tight junctions (TJs), which are formed and maintained by claudins. Targeted binding of CpE to specific claudins, encoded by its C-terminal domain (cCpE), loosens TJ barriers to trigger molecular leaks between cells. Cytotoxicity results from claudin-bound CpE complexes forming pores in cell membranes. In mammalian tissues, ~24 claudins govern TJ barriers—but the basis for CpE’s selective targeting of claudins in the gut was undetermined. We report the structure of human claudin-4 in complex with cCpE, which reveals that enterotoxin targets a motif conserved in receptive claudins and how the motif imparts high-affinity CpE binding to these but not other subtypes. The structural basis of CpE targeting is supported by binding affinities, kinetics, and half-lives of claudin–enterotoxin complexes and by the cytotoxic effects of CpE on claudin-expressing cells. By correlating the binding residence times of claudin–CpE complexes we determined to claudin expression patterns in the gut, we uncover that the primary CpE receptors differ in mice and humans due to sequence changes in the target motif. These findings provide the molecular and structural element CpE employs for subtype-specific targeting of claudins during pathogenicity of C. perfringens in the gut and a framework for new strategies to treat CpE-based illnesses in domesticated mammals and humans.

59 BASIC BIOLOGICAL SCIENCES↗

Targeted Peptide Measurements in Biology and Medicine: Best Practices for Mass Spectrometry-based Assay Development Using a Fit-for-Purpose Approach

Adoption of targeted mass spectrometry (MS) approaches such as multiple reaction monitoring (MRM) to study biological and biomedical questions is well underway in the proteomics community. Successful application depends on the ability to generate reliable assays that uniquely and confidently identify target peptides in a sample. Unfortunately, there is a wide range of criteria being applied to say that an assay has been successfully developed. There is no consensus on what criteria are acceptable and little understanding of the impact of variable criteria on the quality of the results generated. Publications describing targeted MS assays for peptides frequently do not contain sufficient information for readers to establish confidence that the tests work as intended or to be able to apply the tests described in their own labs. Guidance must be developed so that targeted MS assays with established performance can be made widely distributed and applied by many labs worldwide. To begin to address the problems and their solutions, a workshop was held at the National Institutes of Health with representatives from the multiple communities developing and employing targeted MS assays. Participants discussed the analytical goals of their experiments and the experimental evidence needed to establish that the assays they develop work as intended and are achieving the required levels of performance. Using this “fit-for-purpose” approach, the group defined three tiers of assays distinguished by their performance and extent of analytical characterization. Computational and statistical tools useful for the analysis of targeted MS results were described. Participants also detailed the information that authors need to provide in their manuscripts to enable reviewers and readers to clearly understand what procedures were performed and to evaluate the reliability of the peptide or protein quantification measurements reported. This paper presents a summary of the meeting and recommendations. Molecular & Cellular Proteomics 13: 10.1074/mcp.M113.036095, 907–917, 2014.

Environmental Molecular Sciences Laboratory↗

The moving group targets of the seeds high-contrast imaging survey of exoplanets and disks: Results and observations from the first three years

We present results from the first three years of observations of moving group (MG) targets in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) high-contrast imaging survey of exoplanets and disks using the Subaru telescope. We achieve typical contrasts of ∼10{sup 5} at 1'' and ∼10{sup 6} beyond 2'' around 63 proposed members of nearby kinematic MGs. We review each of the kinematic associations to which our targets belong, concluding that five, β Pictoris (∼20 Myr), AB Doradus (∼100 Myr), Columba (∼30 Myr), Tucana-Horogium (∼30 Myr), and TW Hydrae (∼10 Myr), are sufficiently well-defined to constrain the ages of individual targets. Somewhat less than half of our targets are high-probability members of one of these MGs. For all of our targets, we combine proposed MG membership with other age indicators where available, including Ca II HK emission, X-ray activity, and rotation period, to produce a posterior probability distribution of age. SEEDS observations discovered a substellar companion to one of our targets, κ And, a late B star. We do not detect any other substellar companions, but do find seven new close binary systems, of which one still needs to be confirmed. A detailed analysis of the statistics of this sample, and of the companion mass constraints given our age probability distributions and exoplanet cooling models, will be presented in a forthcoming paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Forward modeling fluctuations in the DESI LRGs target sample using image simulations

We use the forward modeling pipeline, Obiwan, to study the imaging systematics of the Luminous Red Galaxies (LRGs) targeted by the Dark Energy Spectroscopic Instrument (DESI). Imaging systematics refers to the false fluctuation of galaxy densities due to varying observing conditions and astrophysical foregrounds corresponding to the imaging surveys from which DESI LRG target galaxies are selected. We update the Obiwan pipeline, which we previously developed to simulate the optical images used to target DESI data, to further simulate WISE images in the infrared. This addition allows simulating the DESI LRGs sample, which utilizes WISE data in the target selection. Deep DESI imaging data combined with a method to account for biases in their shapes is used to define a truth sample of potential LRG targets. We inject these data evenly throughout the DESI Legacy Imaging Survey footprint at declinations between -30 and 32.375 degrees. We simulate a total of 15 million galaxies to obtain a simulated LRG sample (Obiwan LRGs) that predicts the variations in target density due to imaging properties. We find that the simulations predict the trends with depth observed in the data, including how they depend on the intrinsic brightness of the galaxies. We observe that faint LRGs are the main contributing source of the imaging systematics trend induced by depth. We also find significant trends in the data against Galactic extinction that are not predicted by Obiwan. These trends depend strongly on the particular map of Galactic extinction chosen to test against, implying systematic contamination in the Galactic extinction maps is a likely root cause (e.g., Cosmic-Infrared Background, dust temperature correction). We additionally observe a morphological change of the DESI LRGs population evidenced by a correlation between OII emission line average intensity and the size of the z-band PSF. This effect most likely results from uncertainties in background subtraction. The detailed findings we present should be used to guide any observational systematics mitigation treatment for the clustering of the DESI LRGs sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure-function studies of STAR family Quaking proteins bound to their in vivo RNA target sites

Mammalian Quaking (QKI) and its Caenorhabditis elegans homolog, GLD-1 (defective in germ line development), are evolutionarily conserved RNA-binding proteins, which post-transcriptionally regulate target genes essential for developmental processes and myelination. We present X-ray structures of the STAR (signal transduction and activation of RNA) domain, composed of Qua1, K homology (KH), and Qua2 motifs of QKI and GLD-1 bound to high-affinity in vivo RNA targets containing YUAAY RNA recognition elements (RREs). The KH and Qua2 motifs of the STAR domain synergize to specifically interact with bases and sugar-phosphate backbones of the bound RRE. Qua1-mediated homodimerization generates a scaffold that enables concurrent recognition of two RREs, thereby plausibly targeting tandem RREs present in many QKI-targeted transcripts. Structure-guided mutations reduced QKI RNA-binding affinity in vitro and in vivo, and expression of QKI mutants in human embryonic kidney cells (HEK293) significantly decreased the abundance of QKI target mRNAs. Overall, our studies define principles underlying RNA target selection by STAR homodimers and provide insights into the post-transcriptional regulatory function of mammalian QKI proteins.

Teplova, Marianna↗

Semi-inclusive deep-inelastic scattering on a polarized spin-1 target. I. Cross section and spin observables

We develop the theoretical framework for semi-inclusive deep-inelastic scattering on a polarized spin-1 target and apply it to scattering on the polarized deuteron with spectator nucleon tagging. In Part I (this article) we present the general form of the semi-inclusive cross section and polarization observables for the spin-1 target. A relativistically covariant formulation in terms of four-vectors and invariant polarization parameters is employed. The target polarization is described by a spin density matrix with vector and tensor polarization. The spin and azimuthal angle dependence of the semi-inclusive cross section is derived and parametrized in terms of invariant structure functions. To validate the result, the structure functions are expressed as photon-target helicity amplitudes with known symmetry properties. The expressions presented here are kinematic (no assumptions about particle production dynamics) and valid in all regions of the deep-inelastic final state (current and target fragmentation regions). In Part II (following article), we consider deep-inelastic scattering on the polarized deuteron with spectator nucleon tagging as a special case of target fragmentation. The semi-inclusive structure functions are computed by separating nuclear and hadronic structure, and the polarization observables are explored as functions of the tagged nucleon momentum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The development of high-performance alkali-hybrid polarized He 3 targets for electron scattering

We present the development of high-performance polarized ³He targets for use in electron scattering experiments that utilize the technique of alkali-hybrid spin-exchange optical pumping. We include data obtained during the characterization of 24 separate target cells, each of which was constructed while preparing for one of four experiments at Jefferson Laboratory in Newport News, Virginia. The results presented here document dramatic improvement in the performance of polarized ³He targets, as well as the target properties and operating parameters that made those improvements possible. Included in our measurements were determinations of the so-called X-factors that quantify a temperature-dependent and as-yet poorly understood spin-relaxation mechanism that limits the maximum achievable ³He polarization to well under 100%. The presence of this spin-relaxation mechanism was clearly evident in our data. We also present results from a simulation of the alkali-hydrid spin-exchange optical pumping process that was developed to provide guidance in the design of these targets. Good agreement with actual performance was obtained by including details such as off-resonant optical pumping. Now benchmarked against experimental data, the simulation is useful for the design of future targets. Included in our results is a measurement of the K- ³He spin-exchange rate coefficient $k^\mathrm{K}_\mathrm{se} = \left ( 7.46 \pm 0.62 \right )\!\times\!10^{-20}\ \mathrm{cm^3/s}$ over the temperature range 503 K to 563 K.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Picosecond lifetime measurements of resonances using a thick-target invariant-mass technique

Here, a new technique is presented for measuring the half-lives of resonances in the picosecond range using presently available invariant-mass apparatus and a thick target. For short-lived resonances, the energy losses of the decay fragments in the target material change their relative velocities giving rise to a poor invariant-mass resolution. However, for longer-lived resonances that travel through the remaining target material before decaying outside of the target, this dominant contribution to the resolution is eliminated. The measured invariant-mass peak will then display a narrow peak from these events which sits on a wider structure associated with the remaining events that decay in the target. The fraction of the events in the narrow peak is related to the probability that the resonance leaves the target before decaying and hence is related to the lifetime. This technique is exercised for the 2.685-MeV resonance in 33 Cl which decays by emitting an f -wave proton. A half-life of T 1/2 =5.7$^{+4.1}_{-2.5}$ ps was measured which is consistent with values inferred from other known properties of this resonance.

lifetimes & widths↗

Underwater unexploded ordnance discrimination based on intrinsic target polarizabilities – A case study

Seabed unexploded ordnance that resulted partly from the high failure rate among munitions from more than 80 years ago and from decades of military training and testing of weapons systems poses an increasing concern all around the world. Although existing magnetic systems can detect clusters of debris, they are not able to tell whether a munition is still intact requiring special removal (e.g. in situ detonation) or is harmless scrap metal. The marine environment poses unique challenges, and transferring knowledge and approaches from land to a marine environment has not been easy and straightforward. On land, the background soil conductivity is much lower than the conductivity of the unexploded ordnance and the electromagnetic response of a target is essentially the same as that in free space. For those frequencies required for target characterization in the marine environment, the seawater response must be accounted for and removed from the measurements. The system developed for this study uses fields from three orthogonal transmitters to illuminate the target and four three-component receivers to measure the signal arranged in a configuration that inherently cancels the system's response due to the enclosing seawater, the sea–bottom interface and the air–sea interface for shallow deployments. The system was tested as a cued system on land and underwater in San Francisco Bay – it was mounted on a simple platform on top of a support structure that extended 1 m below and allowed the diver to place metal objects to a specific location even in low-visibility conditions. The measurements were stable and repeatable. Furthermore, target responses estimated from marine measurements matched those from land acquisition, confirming that the seawater and air–sea interface responses were removed successfully. Thirty-six channels of normalized induction responses were used for the classification, which was done by estimating the target principal dipole polarizabilities. Our results demonstrated that the system can resolve the intrinsic polarizabilities of the target, with clear distinctions between those of symmetric intact unexploded ordnance and irregular scrap metal. The prototype system was able to classify an object based on its size, shape and metal content and correctly estimate its location and orientation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluation of the interplay effect when using RapidArc to treat targets moving in the craniocaudal or right-left direction

Purpose: We have investigated the dosimetric errors caused by the interplay between the motions of the LINAC and the tumor during the delivery of a volume modulated arc therapy treatment. This includes the development of an IMRT QA technique, applied here to evaluate RapidArc plans of varying complexity. Methods: An IMRT QA technique was developed, which involves taking a movie of the delivered dose (0.2 s frames) using a 2D ion chamber array. Each frame of the movie is then moved according to a respiratory trace and the cumulative dose calculated. The advantage of this approach is that the impact of turning the beam on at different points in the respiratory trace, and of different types of motion, can be evaluated using data from a single irradiation. We evaluated this technique by comparing with the results when we actually moved the phantom during irradiation. RapidArc plans were created to treat a 62 cc spherical tumor in a lung phantom (16 plans) and a 454 cc irregular tumor in an actual patient (five plans). The complexity of each field was controlled by adjusting the MU (312-966 MU). Each plan was delivered to a phantom, and a movie of the delivered dose taken using a 2D ion chamber array. Patient motion was modeled by shifting each dose frame according to a respiratory trace, starting the motion at different phases. The expected dose distribution was calculated by blurring the static dose distribution with the target motion. The dose error due to the interplay effect was then calculated by comparing the delivered dose with the expected dose distribution. Peak-to-peak motion of 0.5, 1.0, and 2.0 cm in the craniocaudal and right-left directions, with target periods of 3 and 5 s, were evaluated for each plan (252 different target motion/plan combinations). Results: The daily dose error due to the interplay effect was less than 10% for 98.4% of all pixels in the target for all plans investigated. The percentage of pixels for which the daily dose error could be larger than 5% increased with increasing plan complexity (field MU), but was less than 15% for all plans if the motion was 1 cm or less. For 2 cm motion, the dose error could be larger than 5% for 40% of pixels, but was less than 5% for more than 80% of pixels for MU<550, and was less than 10% for 99% of all pixels. The interplay effect was smaller for 3 s periods than for 5 s periods. Conclusions: The interplay between the motions of the LINAC and the target can result in an error in the delivered dose. This effect increases with plan complexity, and with target magnitude and period. It may average out after many fractions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analyzing the impact of intrafraction motion: Correlation of different dose metrics with changes in target D{sub 95%}

Purpose: A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures may lead to different conclusions regarding the clinical impact of motion. This study compares the analysis of identical dose perturbations using different dosimetric metrics. Calculated changes in target D{sub 95%} are used as a reference. Methods: A total of 3768 motion-encoded dose distributions were calculated for nine lung tumor patients. The motion-encoded dose distributions were compared to static dose distributions using three dosimetric metrics: 2D {gamma}, 3D {gamma}, and histogram analysis. Each of these metrics was used to analyze dose perturbations both globally and within the target structure. Furthermore, the failing voxels were analyzed separately according to failure mode, i.e., under vs. over-dosed voxels. Metrics were evaluated based on their agreement with changes in target D{sub 95%}. Evaluations included the metrics' maximum average sensitivity and specificity (MASS) in detecting unacceptable deliveries, a coefficient correlated to ranking ({tau}), and the linear correlation coefficient, r. Results: Of the evaluated metrics, the histogram metric restricted to the under-dosed voxels within the target agreed best with changes in target D{sub 95%}. This metric achieved a MASS of 0.93, a {tau} of 0.69, and an r-value of 0.85. In comparison, the unrestricted 2D {gamma} metric achieved MASS = 0.77, {tau} = 0.40, and r = 0.67. Restricting the 2D {gamma} test both geographically and in failure mode increased the MASS to 0.85, {tau} to 0.70, and the r-value to 0.80. Conclusions: This study suggests that any clinical decisions based solely on an unrestricted 2D {gamma} metric are suboptimal. A geographic and failure mode restriction can improve results. The remaining uncertainties with non-DVH (dose volume histogram) based metrics should be kept in mind when they are used to evaluate the dosimetric impact of target motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-300: Spatial Variations of Multiple Off-Axial Targets for a Single Isocenter SRS Treatment Plan in ExacTrac 6D Robotic Couch System

Purpose: To evaluate the spatial variations of multiple off-axial targets for a single isocenter stereotactic radiosurgery (SRS) treatment plan in ExacTrac 6D robotic couch system (BrainLab AG). Methods: Five metallic ball bearing (BB) markers were placed sparsely in 3D off-axial locations (non-coplanar) inside a skull phantom as the representatives of multiple targets mimicking multiple brain metastases. The locations of the BB markers were carefully chosen to minimize overlapping of each other in a port imaging detector plane. The skull phantom was immobilized by a frameless mask and CT scanned with a BrainLab Head and Neck Localizer using a GE Optima MDCT scanner. The CT images were exported to iPlan software (BrainLab AG) and a multiple target PTV was drawn by combining all the contours of the BBs. The margin of the MLC opening was selected as 3 mm expansion outward. Two coplanar arc beams were placed to generate a single isocenter SRS plan to treat the PTV. The arc beams were delivered using Novalis Tx system with portal imaging acquisition mode per 10% temporal resolution. The locations of the BBs were visualized and analyzed with respect to the MLC aperture in the treatment plan similar to the Winston-Lutz test. Results: All the BBs were clearly identified inside the MLC openings. The positional errors for the BBs were overall less than 1 mm along the rotational path of the two arcs. Conclusion: This study verified that the spatial deviations of multiple off-axial targets for a single isocenter SRS treatment plan is within sub-millimeter range in ExacTrac 6D robotic couch system. Accompanied with the Winston-Lutz test, this test will quality-assure the spatial accuracies of the isocenter as well as the positions of multiple off-axial targets for the SRS treatment using a single isocenter multiple target treatment plan.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-06: Intra-Observer Variability in Delineation of Target Volumes in Breast Radiotherapy and Its Effect On Accuracy of Deformation Measurements

Purpose: In breast radiotherapy, the target volume may change during treatment and need adaptation of the treatment plan. This is possible for both tumour bed (TB) and whole breast (WB) target volumes. Delineation of the target (to detect changes) is also subject to uncertainty due to intra- and inter-observer variability. This work measured the uncertainty, due to intraobserver variability, in the quantification of tissue deformation. Methods: Datasets consisting of paired prone and supine CT scans of three patients were used. Significant deformation in target volumes is expected between prone and supine patient positions. The selected cases had 1) no seroma, 2) some seroma, and 3) large seroma. The TB and WB were outlined on each dataset three times by one clinician. Delineation variability was defined as the standard deviations of the distances between observer outlines. For each target volume and each case, tissue deformation between prone and supine delineations was quantified using the Dice similarity coefficient (DSC) and the average surface distance (ASD). The uncertainty in the tissue deformation (due to delineation variability) was quantified by measuring the ranges of DSC and ASD using all combinations of pairs of outlines (9 pairs). Results: For the TB, the range of delineation variability was 0.44-1.16 mm. The deformation, DSC and ASD, (and uncertainty in measurement) of the TB between prone and supine position of the cases were: 1) 0.21 (0.17-0.28) and 12.4 mm (11.8-13 mm); 2) 0.54 (0.51-0.57) and 3.3 mm (3.1-3.5 mm); 3) 0.62 (0.61-0.64) and 4.9 mm (4.6-5.2 mm). WB deformation measurements were subject to less uncertainty due to delineation variability than TB deformation measurements. Conclusion: For the first time, the uncertainty, due to observer variability, in the measurement of the deformation of breast target volumes was investigated. Deformations in these ranges would be difficult to detect. This work was supported in part by Cancer Research-UK under Programme Grant C46/A10588 and in part by the National Institute for Health Research (NIHR) through funding of the biomedical research imaging centre. P. Juneja is supported by the EPSRC Platform Grant EP/H046526/1.

60 APPLIED LIFE SCIENCES↗