Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Unveiling acoustic physics of the CMB using nonparametric estimation of the temperature angular power spectrum for Planck

Estimation of the angular power spectrum is one of the important steps in Cosmic Microwave Background (CMB) data analysis. Here, we present a nonparametric estimate of the temperature angular power spectrum for the Planck 2013 CMB data. The method implemented in this work is model-independent, and allows the data, rather than the model, to dictate the fit. Since one of the main targets of our analysis is to test the consistency of the ΛCDM model with Planck 2013 data, we use the nuisance parameters associated with the best-fit ΛCDM angular power spectrum to remove foreground contributions from the data at multipoles ℓ ≥50. We thus obtain a combined angular power spectrum data set together with the full covariance matrix, appropriately weighted over frequency channels. Our subsequent nonparametric analysis resolves six peaks (and five dips) up to ℓ ∼1850 in the temperature angular power spectrum. We present uncertainties in the peak/dip locations and heights at the 95% confidence level. We further show how these reflect the harmonicity of acoustic peaks, and can be used for acoustic scale estimation. Based on this nonparametric formalism, we found the best-fit ΛCDM model to be at 36% confidence distance from the center of the nonparametric confidence set—this is considerably larger than the confidence distance (9%) derived earlier from a similar analysis of the WMAP 7-year data. Another interesting result of our analysis is that at low multipoles, the Planck data do not suggest any upturn, contrary to the expectation based on the integrated Sachs-Wolfe contribution in the best-fit ΛCDM cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: A Measurement of the DR6 CMB Lensing Power Spectrum and Its Implications for Structure Growth

We present new measurements of cosmic microwave background (CMB) lensing over 9400 deg of the sky. These lensing measurements are derived from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) CMB data set, which consists of five seasons of ACT CMB temperature and polarization observations. We determine the amplitude of the CMB lensing power spectrum at 2.3% precision (43σ significance) using a novel pipeline that minimizes sensitivity to foregrounds and to noise properties. To ensure that our results are robust, we analyze an extensive set of null tests, consistency tests, and systematic error estimates and employ a blinded analysis framework. Our CMB lensing power spectrum measurement provides constraints on the amplitude of cosmic structure that do not depend on Planck or galaxy survey data, thus giving independent information about large-scale structure growth and potential tensions in structure measurements. The baseline spectrum is well fit by a lensing amplitude of A lens = 1.013 ± 0.023 relative to the Planck 2018 CMB power spectra best-fit ΛCDM model and A lens = 1.005 ± 0.023 relative to the ACT DR4 + WMAP best-fit model. From our lensing power spectrum measurement, we derive constraints on the parameter combination $S^{CMBL}_{8}$ ≡ σ 8 (Ω m /0.3) 0.25 of $S^{CMBL}_{8}$ = 0.818 ± 0.022 from ACT DR6 CMB lensing alone and $S^{CMBL}_{8}$ = 0.813 ± 0.018 when combining ACT DR6 and Planck NPIPE CMB lensing power spectra. These results are in excellent agreement with ΛCDM model constraints from Planck or ACT DR4 + WMAP CMB power spectrum measurements. Our lensing measurements from redshifts z ~ 0.5–5 are thus fully consistent with ΛCDM structure growth predictions based on CMB anisotropies probing primarily z ~ 1100. We find no evidence for a suppression of the amplitude of cosmic structure at low redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

The electric dipole moment of cobalt monoxide, CoO

A number of low-rotational lines of the E{sup 4}Δ{sub 7/2} ← X{sup 4}Δ{sub 7/2} (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h{sub 7/2}, and the electron quadrupole parameter, eQq{sub 0}, for the E{sup 4}Δ{sub 7/2}(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ{sup -vector}{sub el}, for the X{sup 4}Δ{sub 7/2} (υ = 0) and E{sup 4}Δ{sub 7/2} (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F′ = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F′ = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Hubble Space Telescope PanCET Program: An Optical to Infrared Transmission Spectrum of HAT-P-32Ab

We present a 0.3−5 μm transmission spectrum of the hot Jupiter HAT-P-32Ab observed with the Space Telescope Imaging Spectrograph and Wide Field Camera 3 instruments mounted on the Hubble Space Telescope, combined with Spitzer Infrared Array Camera photometry. The spectrum is composed of 51 spectrophotometric bins with widths ranging between 150 and 400 Å, measured to a median precision of 215 ppm. Comparisons of the observed transmission spectrum to a grid of 1D radiative-convective equilibrium models indicate the presence of clouds/hazes, consistent with previous transit observations and secondary eclipse measurements. To provide more robust constraints on the planet’s atmospheric properties, we perform the first full optical to infrared retrieval analysis for this planet. The retrieved spectrum is consistent with a limb temperature of 1248{sub −92}{sup +92} K, a thick cloud deck, enhanced Rayleigh scattering, and ∼10× solar H{sub 2}O abundance. We find log(Z/Z {sub ⊙}) = 2.41{sub −0.07}{sup +0.06}, and compare this measurement with the mass–metallicity relation derived for the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical simulation of quasi-multifractal diffusion process

The properties of quasi-multifractal diffusion process are discussed. A discrete model of the process is constructed, and a method is proposed for calculating the quasi-multifractal spectrum, based on statistical processing of its realizations. An analysis of multifractal properties performed by numerical simulation of the quasi-multifractal spectrum is qualitatively substantiated by examining realizations of the simulated process. The results of numerical simulations suggest that there are three distinct scaling regions. Special attention is given to comparative analyses between numerical and analytical results and between realizations of the proposed process and the well-known multifractal random walk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chandra Discovery of a Candidate Hyperluminous X-Ray Source in MCG+11-11-032

We present a multiwavelength analysis of MCG+11-11-032, a nearby active galactic nucleus (AGN), with a unique classification as being both a binary and a dual AGN candidate. With new Chandra observations, we aim to resolve any dual AGN system via imaging data and search for signs of a binary AGN via analysis of the X-ray spectrum. Analyzing the Chandra spectrum, we find no evidence of the previously suggested double-peaked Fe Kα lines; the spectrum is instead best fit by an absorbed power law with a single Fe Kα line, as well as an additional line centered at ≈7.5 keV. The Chandra observation reveals faint, soft, and extended X-ray emission, possibly linked to low-level nuclear outflows. Further analysis shows evidence for a compact hard source—MCG+11-11-032 X2—located 3.″3 from the primary AGN. Modeling MCG+11-11-032 X2 as a compact source, we find that it is relatively luminous (L2–10 keV=1.5−0.5+0.9×1041erg s$^{−1}$), and the location is coincident with a compact and off-nuclear source resolved in Hubble Space Telescope infrared (F105W) and optical (F621M, F547M) bands. Pairing our X-ray results with a 144 MHz radio detection at the host galaxy location, we observe X-ray and radio properties similar to those of ESO 243-49 HLX-1, suggesting that MCG+11-11-032 X2 may be a hyperluminous X-ray source. This detection with Chandra highlights the importance of a high-resolution X-ray imager as well as how previous binary AGN candidates detected with large-aperture instruments can benefit from high-resolution follow-up. Future spatially resolved optical spectra, and deeper X-ray observations, can better constrain the origin of MCG+11-11-032 X2.

79 ASTRONOMY AND ASTROPHYSICS↗

Tokamak-independent software analysis suite for multi-spectral line-polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (mse) diagnostics. The software supports multi-spectral line-polarization mse diagnostics which simultaneously measure emission at the mse σ and π lines as well as at two "background" wavelengths that are displaced from the mse spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially polarized background light at the σ and π wavelengths even in situations where the background light changes rapidly in time and space, a distinct improvement over traditional "time-interpolation" background estimation. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the mse photo-elastic modulators (pem's) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to pem retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the mse diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge. As a result, the software suite is modular, parallelized, and portable to other facilities.

97 MATHEMATICS AND COMPUTING↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities. (2016-06-06)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relevance of Bose-Einstein condensation to the interference of two independent Bose gases

Interference of two independently prepared ideal Bose gases is discussed, on the basis of the idea of measurement-induced interference. It is known that, even if the number of atoms in each gas is individually fixed finite and the symmetry of the system is not broken, an interference pattern is observed on each single snapshot. The key role is played by the Hanbury Brown and Twiss effect, which leads to an oscillating pattern of the cloud of identical atoms. Then, how essential is the Bose-Einstein condensation to the interference? In this work, we describe two ideal Bose gases trapped in two separate three-dimensional harmonic traps at a finite temperature T, using the canonical ensembles (with fixed numbers of atoms). We compute the full statistics of the snapshot profiles of the expanding and overlapping gases released from the traps. We obtain a simple formula valid for finite T, which shows that the average fringe spectrum (average fringe contrast) is given by the purity of each gas. The purity is known to be a good measure of condensation, and the formula clarifies the relevance of the condensation to the interference. The results for T=0, previously known in the literature, can be recovered from our analysis. The fluctuation of the interference spectrum is also studied, and it is shown that the fluctuation is vanishingly small only below the critical temperature T{sub c}, meaning that interference pattern is certainly observed on every snapshot below T{sub c}. The fact that the number of atoms is fixed in the canonical ensemble is crucial to this vanishing fluctuation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seasonal variations of the atmospheric muon neutrino spectrum measured with IceCube

This study presents an analysis of seasonal variations in the atmospheric muon neutrino flux, using 11.3 years of data from the IceCube Neutrino Observatory. By leveraging a novel spectral unfolding method, we explore the energy range from 125 GeV to 10 TeV for zenith angles from 90° to 110°, corresponding to the Antarctic atmosphere. Our findings reveal that the differential measurement of the amplitudes of the seasonal variation is consistent with an energy-dependent decrease reaching (-4.5 ± 1.2)% during Austral winter and increase to (+ 3.9 ± 1.3)% during Austral summer relative to the annual average at 10 TeV. While the unfolded flux exceeds the model predictions by up to 30%, the differential measurement of the seasonal to annual average flux remains unaffected. The measured seasonal variations of the muon neutrino spectrum are consistent with theoretical predictions using the MCEq code and the NRLMSISE-00 atmospheric model.

Astroparticle Physics and High-Energy Cosmic Pheno↗

Charge transfer effects in electrocatalytic Ni-C revealed by x-ray photoelectron spectroscopy

Binary Ni-C thin-film alloys, which have been shown to be passive against corrosion in hot sulphuric acid solution whilst also being electrocatalytically active, were investigated by XPS to determine the oxidation state of the metal and carbon components. The Ni component produces a Ni 2p spectrum similar to that of metallic nickel (i.e., no oxidation occurs) but with a 0.3 eV shift to higher binding energy (BE) due to electron donation to the carbon matrix. The C 1s peak shows a shift to lower BE by accepting electrons from the Ni nanocrystals. A cluster-model analysis of the observed Ni 2p spectrum is consistent with the electron transfer from the nickel to the carbon.

36 MATERIALS SCIENCE↗

Gene expression analysis of precision-cut human liver slices indicates stable expression of ADME-Tox related genes

In the process of drug development it is of high importance to test the safety of new drugs with predictive value for human toxicity. A promising approach of toxicity testing is based on shifts in gene expression profiling of the liver. Toxicity screening based on animal liver cells cannot be directly extrapolated to humans due to species differences. The aim of this study was to evaluate precision-cut human liver slices as in vitro method for the prediction of human specific toxicity by toxicogenomics. The liver slices contain all cell types of the liver in their natural architecture. This is important since drug-induced toxicity often is a multi-cellular process. Previously we showed that toxicogenomic analysis of rat liver slices is highly predictive for rat in vivo toxicity. In this study we investigated the levels of gene expression during incubation up to 24 h with Affymetrix microarray technology. The analysis was focused on a broad spectrum of genes related to stress and toxicity, and on genes encoding for phase-I, -II and -III metabolizing enzymes and transporters. Observed changes in gene expression were associated with cytoskeleton remodeling, extracellular matrix and cell adhesion, but for the ADME-Tox related genes only minor changes were observed. PCA analysis showed that changes in gene expression were not associated with age, sex or source of the human livers. Slices treated with acetaminophen showed patterns of gene expression related to its toxicity. These results indicate that precision-cut human liver slices are relatively stable during 24 h of incubation and represent a valuable model for human in vitro hepatotoxicity testing despite the human inter-individual variability.

60 APPLIED LIFE SCIENCES↗

Exhaustive Product Analysis of Three Benzene Discharges by Microwave Spectroscopy

Using chirped and cavity microwave spectroscopies, automated double resonance, new high-speed fitting and deep learning algorithms, and large databases of computed structures, the discharge products of benzene alone, or in combination with molecular oxygen or nitrogen, have been exhaustively characterized between 6.5 and 26 GHz. In total, more than 3300 spectral features were observed; 89% of these, accounting for 97% of the total intensity, have now been assigned to 152 distinct chemical species and 60 of their variants (i.e., isotopic species and vibrationally excited states). Roughly 50 of the products are entirely new or poorly characterized at high resolution, including many heavier by mass than the precursor benzene. These findings provide direct evidence for a rich architecture of two- and three-dimensional carbon and indicate that benzene growth, particularly the formation of ring–chain molecules, occurs facilely under our experimental conditions. The present analysis also illustrates the utility of microwave spectroscopy as a precision tool for complex mixture analysis, irrespective of whether the rotational spectrum of a product species is known a priori or not. From this large quantity of data, for example, it is possible to determine with confidence the relative abundances of different product masses, but more importantly the relative abundances of different isomers with the same mass. We review the complementary nature of this type of analysis to traditional mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and modeling of edge fluctuations and transport mechanism in the Maryland Centrifugal Experiment

The Maryland Centrifugal Experiment [R. F. Ellis et al., Phys. Plasmas 12, 055704 (2005)] is a mirror machine designed to have a plasma axially confined by supersonic rotation and dominantly interchange stable by the radial shear in the azimuthal velocity. Nevertheless, residual fluctuations still persist. To investigate the presence of such fluctuations, an azimuthal array of 16 magnetic pickup coils at the edge region of the plasma has been employed. A comprehensive analysis of the magnetic fluctuations reveals that, under the imposed shear flow, only m=0 and m=2 modes are dominant; yet, the observed frequency spectrum is broadband. Using higher order spectral analysis, clear evidence of nonlinear mode coupling is detected. It is also observed that the amplification of magnetic fluctuations leads to enhanced transport consistent with the drop of the plasma density and voltage. As a result, the magnetic fluctuations start to decrease in amplitude as the central plasma pressure drops. In return, the anomalous radial particle and momentum transport are reduced; thus, the plasma confinement improves. As the plasma pressure starts to build up, the plasma voltage increases, destabilizing the m=2 interchange mode. The cycle of enhanced transport and intermittent fluctuations repeats itself. A two-dimensional magnetohydrodynamics code in slab geometry is employed to investigate the dynamics of the primary interchange instability and to assess the level of transport. For very low sheared rotation, a broad spatial spectrum of unstable modes is obtained. As the sheared rotation is increased, the high mode numbers become stabilized and low mode numbers dominate the spectrum. Both the experimental data obtained from the azimuthal array probes and the simulations in case of parabolic shear flow show clear evidence of nonlinear mode coupling, explaining the broadband frequency spectrum for low mode numbers. A detailed comparison of spatiotemporal dynamics of simulations with the experimental data is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of muon neutrino disappearance with the MINOS detectors and the NuMI neutrino beam

This thesis presents the results of an analysis of v μ disappearance with the MINOS experiment, which studies the neutrino beam produced by the NuMI facility at Fermi National Accelerator Laboratory. The rates and energy spectra of charged current v μ interactions are measured in two similar detectors, located at distances of 1 km and 735 km along the NuMI beamline. The Near Detector provides accurate measurements of the initial beam composition and energy, while the Far Detector is sensitive to the effects of neutrino oscillations. The analysis uses data collected between May 2005 and March 2007, corresponding to an exposure of 2.5 x 10 20 protons on target. As part of the analysis, sophisticated software was developed to identify muon tracks in the detectors and to reconstruct muon kinematics. Events with reconstructed tracks were then analyzed using a multivariate technique to efficiently isolate a pure sample of charged current v μ events. An extrapolation method was also developed, which produces accurate predictions of the Far Detector neutrino energy spectrum, based on data collected at the Near Detector. Finally, several techniques to improve the sensitivity of an oscillation measurement were implemented, and a full study of the systematic uncertainties was performed. Extrapolating from observations at the Near Detector, 733 ± 29 Far Detector events were expected in the absence of oscillations, but only 563 events were observed. This deficit in event rate corresponds to a significance of 4.3 standard deviations. The deficit is energy dependent and clear distortion of the Far Detector energy spectrum is observed. A maximum likelihood analysis, which fully accounts for systematic uncertainties, is used to determine the allowed regions for the oscillation parameters and identifies the best fit values as Δm$2\atop{32}$ = 2.29$+0.14\atop{-0.14}$ x 10 -3 eV 2 and sin 2 2θ 23 > 0.953 (68% confidence level). The models of neutrino decoherence and decay are disfavored at the 5.0σ and 3.2σ levels respectively, while the no oscillation model is excluded at the 9.4σ level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmological neutrino mass: a frequentist overview in light of DESI

We derive constraints on the neutrino mass using a variety of recent cosmological datasets, including DESI BAO, the full-shape analysis of the DESI matter power spectrum and the one-dimensional power spectrum of the Lyman-α forest (P1D) from eBOSS quasars as well as the cosmic microwave background (CMB). The constraints are obtained in the frequentist formalism by constructing profile likelihoods and applying the Feldman-Cousins prescription to compute confidence intervals. This method avoids potential prior and volume effects that may arise in a comparable Bayesian analysis. Parabolic fits to the profiles allow one to distinguish changes in the upper limits from variations in the constraining power σ of the different data combinations. We find that all profiles in the ΛCDM model are cut off by the ∑m ν ≥ 0 bound, meaning that the corresponding parabolas reach their minimum in the unphysical sector. The most stringent 95% C.L. upper limit is obtained by the combination of DESI DR2 BAO, Planck PR4 and CMB lensing at 53 meV, below the minimum of 59 meV set by the normal ordering. The corresponding constraining power σ is 43 meV, which highlights the importance of the cut-off by negative values in the determination of the upper limit. Extending ΛCDM to non-zero curvature and w 0 w a CDM relaxes the constraints past 59 meV again, but only w 0 w a CDM exhibits profiles with a minimum at a positive value. Additionally, we extend the formalism to constrain the lightest neutrino mass. For DESI DR2 BAO, Planck PR4 and CMB lensing, we find confidence limits at 20 and 19 meV for normal and inverted ordering, respectively. Using a combination of DESI DR1 full-shape, BBN and eBOSS Lyman-α P1D, we successfully constrain the neutrino mass independently of the CMB. This combination yields m l ≤ 97 and 98 meV in the normal and inverted orderings, and total neutrino mass ∑m ν ≤ 285 meV (95% C.L.). The addition of DESI full-shape or Lyman-α P1D to CMB and DESI BAO results in small but noticeable improvement of the constraining power of the data. Lyman-α free-streaming measurements especially improve the constraint. Since they are based on eBOSS data, this sets a promising precedent for upcoming DESI data.

Frequentist statistics↗

Reflectivity and spectrum of relativistic flying plasma mirrors

Flying plasma mirrors induced by intense lasers via laser wake field acceleration scheme have been proposed as a promising way to generate few-cycle EUV or x-ray lasers. In addition, if such a relativistic plasma mirror can accelerate, then it would serve as an analog black hole to investigate the information loss paradox associated with the black hole Hawking evaporation. Among these applications, the reflectivity, which is usually frequency-dependent, would affect the outgoing photon spectrum and, therefore, impact on the analysis of the physics under investigation. In this paper, these two issues are investigated analytically and numerically with one-dimensional particle-in-cell simulations. Based on our simulation results, we propose a new model that provides a better estimate of the reflectivity than those studied previously. Moreover, we found that the peak frequency of the reflected spectrum of a Gaussian incident wave deviates from the expected value, 4γ 2 ω, due to the dependence of reflectivity on the frequency of the incident wave.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗