Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Bath and Shower Effects in the Rat Parotid Gland Explain Increased Relative Risk of Parotid Gland Dysfunction After Intensity-Modulated Radiotherapy

Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect). Methods and Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.e., subtolerance) dose levels for a bath-dose, both whole parotid glands were irradiated with 5 to 25 Gy. Subsequently groups of Wistar rats received 30 Gy to the caudal 50% (shower) and 0 to 10 Gy to the cranial 50% (bath) of both parotid glands. Stimulated saliva flow rate (function) was measured before and up to 240 days after irradiation. Results: Irradiation of both glands up to a dose of 10 Gy did not result in late loss of function and is thus regarded subtolerance. Addition of a dose bath of 1 to 10 Gy to a high-dose in the caudal 50% of the glands resulted in enhanced function loss. Conclusion: Similar to the spinal cord, the parotid gland demonstrates a bath and shower effect, which may explain the less-than-expected sparing of function after IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Capecitabine and Pelvic Radiation in Locally Advanced Rectal Cancer-Is it Equivalent to 5-FU Infusion Plus Leucovorin and Radiotherapy?

Purpose: The aim of this retrospective case-matching study was to compare the treatment outcomes and acute toxicity of preoperative radiotherapy (RT) with capecitabine vs. preoperative RT with intermittent 5-fluorouracil (5-FU) infusion, leucovorin, and mitomycin C in rectal cancer. Methods and Materials: We matched 34 patients who were treated with preoperative concurrent capecitabine and 50 Gy of RT by their clinical T stage (T3 or T4) and the tumor location (<=7 cm or >7 cm from the anal verge) with another 68 patients who were treated with preoperative intermittent 5-FU infusion, leucovorin, mitomycin C, and 50 Gy of RT for a comparison of the pathologic tumor response, local control, distant failure, and survival rates. Results: The pathologic complete response rate was 21% with capecitabine and 18% with 5-FU and leucovorin (p = 0.72). The rate of T downstaging after chemoradiation was 59% for both groups. The rate of sphincter-sparing resection was 38% after capecitabine plus RT and 43% after 5-FU plus RT (p = 0.67). At 3 years, there was no significant difference in the local control rate (93% for capecitabine and 92% for 5-FU and leucovorin), relapse-free rate (74% for capecitabine and 73% for 5-FU and leucovorin), or disease-specific survival rate (86% for capecitabine and 77% for 5-FU and leucovorin). The acute toxicity profile was comparable, with little Grade 3 and 4 toxicity. Conclusions: When administered with concurrent preoperative RT, both capecitabine and intermittent 5-FU infusion with leucovorin modulation provided comparable pathologic tumor response, local control, relapse-free survival, and disease-specific survival rates in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Whole Abdominal Radiotherapy After Surgery and Carboplatin/Taxane Chemotherapy for Advanced Ovarian Cancer: Phase I Study

Purpose: To assess the feasibility and toxicity of consolidative intensity-modulated whole abdominal radiotherapy (WAR) after surgery and chemotherapy in high-risk patients with advanced ovarian cancer. Methods and Materials: Ten patients with optimally debulked ovarian cancer International Federation of Gynecology and Obstetrics Stage IIIc were treated in a Phase I study with intensity-modulated WAR up to a total dose of 30 Gy in 1.5-Gy fractions as consolidation therapy after adjuvant carboplatin/taxane chemotherapy. Treatment was delivered using intensity-modulated radiotherapy in a step-and-shoot technique (n = 3) or a helical tomotherapy technique (n = 7). The planning target volume included the entire peritoneal cavity and the pelvic and para-aortal node regions. Organs at risk were kidneys, liver, heart, vertebral bodies, and pelvic bones. Results: Intensity-modulated WAR resulted in an excellent coverage of the planning target volume and an effective sparing of the organs at risk. The treatment was well tolerated, and no severe Grade 4 acute side effects occurred. Common Toxicity Criteria Grade III toxicities were as follows: diarrhea (n = 1), thrombocytopenia (n = 1), and leukopenia (n = 3). Radiotherapy could be completed by all the patients without any toxicity-related interruption. Median follow-up was 23 months, and 4 patients had tumor recurrence (intraperitoneal progression, n = 3; hepatic metastasis, n = 1). Small bowel obstruction caused by adhesions occurred in 3 patients. Conclusions: The results of this Phase I study showed for the first time, to our knowledge, the clinical feasibility of intensity-modulated whole abdominal radiotherapy, which could offer a new therapeutic option for consolidation treatment of advanced ovarian carcinoma after adjuvant chemotherapy in selected subgroups of patients. We initiated a Phase II study to further evaluate the toxicity of this intensive multimodal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Electron Radiotherapy for the Management of Aggressive Fibromatosis

Purpose: We analyzed our experience with intraoperative electron radiotherapy (IOERT) followed by moderate doses of external beam radiotherapy (EBRT) after organ-sparing surgery in patients with primary or recurrent aggressive fibromatosis. Methods and Materials: Indication for IOERT and postoperative EBRT as an individual treatment approach to avoid mutilating surgical procedures was seen when complete surgical removal seemed to be unlikely or impossible. A total of 31 lesions in 30 patients were treated by surgery and IOERT with a median dose of 12 Gy. Median age was 31 years (range, 13-59 years). Resection status was close margin in six lesions, microscopically positive in 13, and macroscopically positive in 12. Median tumor size was 9 cm. In all, 25 patients received additional EBRT, with a median dose of 45 Gy (range, 36-54 Gy). Results: After a median follow-up of 32 months (range, 3-139 months), no disease-related deaths occurred. A total of five local recurrences were seen, resulting in actuarial 3-year local control rates of 82% overall and 91% inside the IOERT areas. Trends to improved local control were seen for older age (>31 years) and negative margins, but none of these factors reached significance. Perioperative complications were found in six patients, in particular as wound healing disturbances in five patients and venous thrombosis in one patient. Late toxicity was seen in five patients. Conclusion: Introduction of IOERT into a multimodal treatment approach in patients with aggressive fibromatosis is feasible with low toxicity and yielded good local control rates even in patients with microscopical or gross residual disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Robustness of IMPT and IMRT for Prostate Cancer Against Organ Movement

Purpose: Intensity-modulated radiotherapy with photons (IMRT) and protons (IMPT) produces dose distributions that have high conformality to the planning target volume and sufficient sparing of the organs at risk if calculated on a single static computed tomography (CT) scan. For prostate cancer patients, organ movement with related changes to the density distribution in the irradiated volume occurs during the treatment course. We evaluated the sensitivity of IMPT and IMRT plans to organ movement. Methods and Materials: IMPT and IMRT treatment plans were evaluated for 4 patients with an average of 16 CT data sets per patient. The treatment plans were recalculated on all treatment CT scans, and the dose was accumulated in the reference geometry using a deformable registration algorithm. Accurate dose calculation methods were applied for both IMPT and IMRT. Results: With IMPT, unacceptably low total doses in the gross tumor volume were observed for patients with gas in the rectum on the planning CT scan. To achieve a total equivalent uniform dose (EUD) and EUD spread similar to that with IMRT, two methods were crucial for IMPT-a rectal gas water-equivalent density overwrite in the original planning CT scan and initial beam weight setting to achieve a homogeneous dose distribution for the whole planning target volume for each field separately. An improvement in the total EUD for the prostate and rectal wall was also observed for IMRT with the water-equivalent density overwrite of the rectal cavities. Conclusion: The sensitivities of IMPT and IMRT to organ movement are of the same order if appropriate planning strategies are applied. The latter is especially crucial for IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Methods to Reduce Dose to Swallowing-Related Structures in Head and Neck Cancer

Introduction: Emerging data suggest that reduction of dose to the larynx and pharyngeal constrictor may lower the risk of swallowing complications such as long-term gastrostomy dependence and aspiration. Organ avoidance becomes difficult when the primary tumor or involved nodes are present at the level of the larynx. Materials and Methods: Fifteen patients with Stage III-IV squamous cell carcinoma of the head and neck with high-dose target volume at the level of the larynx (but not involving the glottic larynx) were planned with whole-field IMRT (WF-IMRT), as well as a low anterior neck field dynamically matched to an IMRT plan (D-SCLV). Plans were compared with respect to coverage of targets and sparing of normal tissues including the larynx, inferior pharyngeal constrictor (IPC), parotid, and cord. Results: There was no significant difference between the two techniques in coverage of the high- or intermediate-dose planning target volumes (PTVs). Coverage of the elective nodal PTV was inferior with the D-SCLV technique, with a mean of 96.5% vs. 86.3% of the volume receiving the prescription dose (p = 0.001) compared with WF-IMRT plans. However, the D-SCLV technique significantly reduced mean dose to the larynx (43.7 vs. 46.7 Gy, p = 0.05) and IPC (39.1 vs. 46.1 Gy, p = 0.002). There was no significant difference in dose to the parotid or cord. Conclusion: Given the steep dose responses seen in studies examining the association between swallowing toxicity and dose to the larynx and IPC, dose reductions using the D-SCLV technique may be clinically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Improves Dosimetry and Reduces Treatment Time Compared to Conventional Intensity-Modulated Radiotherapy for Locoregional Radiotherapy of Left-Sided Breast Cancer and Internal Mammary Nodes

Purpose: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes. Methods and Materials: Therapy for 5 patients previously treated with 50 Gy/25 fractions using nine-field cIMRT was replanned with VMAT and MWT. Comparative endpoints were planning target volume (PTV) dose homogeneity, doses to surrounding structures, number of monitor units, and treatment delivery time. Results: For VMAT, two 190 deg. arcs with 2-cm overlapping jaws were required to optimize over the large treatment volumes. Treatment plans generated using VMAT optimization resulted in PTV homogeneity similar to that of cIMRT and MWT. The average heart volumes receiving >30 Gy for VMAT, cIMRT, and MWT were 2.6% +- 0.7%, 3.5% +- 0.8%, and 16.4% +- 4.3%, respectively, and the average ipsilateral lung volumes receiving >20 Gy were 16.9% +- 1.1%, 17.3% +- 0.9%, and 37.3% +- 7.2%, respectively. The average mean dose to the contralateral medial breast was 3.2 +- 0.6 Gy for VMAT, 4.3 +- 0.4 Gy for cIMRT, and 4.4 +- 4.7 Gy for MWT. The healthy tissue volume percentages receiving 5 Gy were significantly larger with VMAT (33.1% +- 2.1%) and IMRT (45.3% +- 3.1%) than with MWT (19.4% +- 3.7%). VMAT reduced the number of monitor units by 30% and the treatment time by 55% compared with cIMRT. Conclusions: VMAT achieved similar PTV coverage and sparing of organs at risk, with fewer monitor units and shorter delivery time than cIMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer Modeling of Yttrium-90-Microsphere Transport in the Hepatic Arterial Tree to Improve Clinical Outcomes

Purpose: Radioembolization (RE) via yttrium-90 ({sup 90}Y) microspheres is an effective and safe treatment for unresectable liver malignancies. However, no data are available regarding the impact of local blood flow dynamics on {sup 90}Y-microsphere transport and distribution in the human hepatic arterial system. Methods and Materials: A three-dimensional (3-D) computer model was developed to analyze and simulate blood-microsphere flow dynamics in the hepatic arterial system with tumor. Supplemental geometric and flow data sets from patients undergoing RE were also available to validate the accuracy of the computer simulation model. Specifically, vessel diameters, curvatures, and branching patterns, as well as blood flow velocities/pressures and microsphere characteristics (i.e., diameter and specific gravity), were measured. Three-dimensional computer-aided design software was used to create the vessel geometries. Initial trials, with 10,000 noninteracting microspheres released into the hepatic artery, used resin spheres 32-{mu}m in diameter with a density twice that of blood. Results: Simulations of blood flow subject to different branch-outlet pressures as well as blood-microsphere transport were successfully carried out, allowing testing of two types of microsphere release distributions in the inlet plane of the main hepatic artery. If the inlet distribution of microspheres was uniform (evenly spaced particles), a greater percentage would exit into the vessel branch feeding the tumor. Conversely, a parabolic inlet distribution of microspheres (more particles around the vessel center) showed a high percentage of microspheres exiting the branch vessel leading to the normal liver. Conclusions: Computer simulations of both blood flow patterns and microsphere dynamics have the potential to provide valuable insight on how to optimize {sup 90}Y-microsphere implantation into hepatic tumors while sparing normal tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks

Purpose: To prospectively compare setup error in standard thermoplastic masks and skin-sparing masks (SSMs) modified with low neck cutouts for head-and-neck intensity-modulated radiation therapy (IMRT) patients. Methods and Materials: Twenty head-and-neck IMRT patients were randomized to be treated in a standard mask (SM) or SSM. Cone-beam computed tomography (CBCT) scans, acquired daily after both initial setup and any repositioning, were used for initial and residual interfraction evaluation, respectively. Weekly, post-IMRT CBCT scans were acquired for intrafraction setup evaluation. The population random (sigma) and systematic (SIGMA) errors were compared for SMs and SSMs. Skin toxicity was recorded weekly by use of Radiation Therapy Oncology Group criteria. Results: We evaluated 762 CBCT scans in 11 patients randomized to the SM and 9 to the SSM. Initial interfraction sigma was 1.6 mm or less or 1.1 deg. or less for SM and 2.0 mm or less and 0.8 deg. for SSM. Initial interfraction SIGMA was 1.0 mm or less or 1.4 deg. or less for SM and 1.1 mm or less or 0.9 deg. or less for SSM. These errors were reduced before IMRT with CBCT image guidance with no significant differences in residual interfraction or intrafraction uncertainties between SMs and SSMs. Intrafraction sigma and SIGMA were less than 1 mm and less than 1 deg. for both masks. Less severe skin reactions were observed in the cutout regions of the SSM compared with non-cutout regions. Conclusions: Interfraction and intrafraction setup error is not significantly different for SSMs and conventional masks in head-and-neck radiation therapy. Mask cutouts should be considered for these patients in an effort to reduce skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Treatment Plans With RapidArc for Prostate Cancer Involving Seminal Vesicles and Lymph Nodes

Purpose: Dosimetric results and treatment delivery efficiency of RapidArc plans to those of conventional intensity-modulated radiotherapy (IMRT) plans were compared using the Eclipse treatment planning system for high-risk prostate cancer. Materials and Methods: This study included 10 patients. The primary planning target volume (PTV{sub P}) contained prostate, seminal vesicles, and pelvic lymph nodes with a margin. The boost PTV (PTV{sub B}) contained prostate and seminal vesicles with a margin. The total prescription dose was 75.6 Gy (46.8 Gy to PTV{sub P} and an additional 28.8 Gy to PTV{sub B}; 1.8 Gy/fraction). Three plans were generated for each PTV: Multiple-field IMRT, one-arc RapidArc (1ARC), and two-arc RapidArc (2ARC). Results: In the primary IMRT with PTV{sub P}, average mean doses to bladder, rectum and small bowel were lower by 5.9%, 7.7% and 4.3%, respectively, than in the primary 1ARC and by 3.6%, 4.8% and 3.1%, respectively, than in the primary 2ARC. In the boost IMRT with PTV{sub B}, average mean doses to bladder and rectum were lower by 2.6% and 4.8% than with the boost 1ARC and were higher by 0.6% and 0.2% than with the boost 2ARC. Integral doses were 7% to 9% higher with RapidArc than with IMRT for both primary and boost plans. Treatment delivery time was reduced by 2-7 minutes using RapidArc. Conclusion: For PTVs including prostate, seminal vesicles, and lymph nodes, IMRT performed better in dose sparing for bladder, rectum, and small bowel than did RapidArc. For PTVs including prostate and seminal vesicles, RapidArc with two arcs provided plans comparable to those for IMRT. The treatment delivery is more efficient with RapidArc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Jaws and Dynamic Couch in Helical Tomotherapy

Purpose: To investigate the next generation of helical tomotherapy delivery with dynamic jaw and dynamic couch movements. Methods and Materials: The new technique of dynamic jaw and dynamic couch movements is described, and a comparative planning study is performed. Ten nasopharyngeal cancer patients with skull base infiltration were chosen for this comparison of longitudinal dose profiles using regular tomotherapy delivery, running-start-stop treatment, and dynamic jaw and dynamic couch delivery. A multifocal simultaneous integrated boost concept was used (70.4Gy to the primary tumor and involved lymph nodes; 57.4Gy to the bilateral cervical lymphatic drainage pathways, 32 fractions). Target coverage, conformity, homogeneity, sparing of organs at risk, integral dose, and radiation delivery time were evaluated. Results: Mean parotid dose for all different deliveries was between 24.8 and 26.1Gy, without significant differences. The mean integral dose was lowered by 6.3% by using the dynamic technique, in comparison with a 2.5-cm-field width for regular delivery and 16.7% with 5-cm-field width for regular delivery. Dynamic jaw and couch movements reduced the calculated radiation time by 66% of the time required with regular 2.5-cm-field width delivery (199 sec vs. 595 sec, p < 0.001). Conclusions: The current delivery mode of helical tomotherapy produces dose distributions with conformal avoidance of parotid glands, brain stem, and spinal cord. The new technology with dynamic jaw and couch movements improves the plan quality by reducing the dose penumbra and thereby reducing the integral dose. In addition, radiation time is reduced by 66% of the regular delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decreasing Temporal Lobe Dose With Five-Field Intensity-Modulated Radiotherapy for Treatment of Pituitary Macroadenomas

Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV) = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving {>=}25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p < 10{sup -7} for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Dose for Minimally Moving Thoracic Lesions Treated With Respiration Gating

Purpose: To evaluate incidental doses to benign lung tissue for patients with minimally moving lung lesions treated with respiratory gating. Methods and Materials: Seventeen lung patient plans were studied retrospectively. Tumor motion was less than 5 mm in all cases. For each patient, mid-ventilation (MidVen) and mid-inhalation (MidInh) breathing phases were reconstructed. The MidInh phase was centered on the end-of-inhale (EOI) phase within a 30% gating window. Planning target volumes, heart, and spinal cord were delineated on the MidVen phase and transferred to the MidInh phase. Lungs were contoured separately on each phase. Intensity-modulated radiotherapy plans were generated on the MidVen phases. The plans were transferred to the MidInh phase, and doses were recomputed. The evaluation metric was based on dose indices, volume indices, generalized equivalent uniform doses, and mass indices for targets and critical structures. Statistical tests were used to establish the significance of the differences between the reference (MidVen) and compared (MidInh) dose distributions. Results: Statistical tests demonstrated that the indices evaluated for targets, cord, and heart differed by within 2.3%. The index differences in the lungs, however, are in excess of 6%, indicating the potentially achievable lung sparing and/or dose escalation. Conclusions: Respiratory gating is a clinical option for patients with minimally moving lung lesions treated at EOI. Gating will be more beneficial for larger tumors, since dose escalation in those cases will result in a larger increase in the tumor control probability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Collimator Trajectory in Volumetric Modulated Arc Therapy: Development and Evaluation for Paraspinal SBRT

Purpose: To develop a collimator trajectory optimization paradigm for volumetric modulated arc therapy (VMAT) and evaluate this technique in paraspinal stereotactic body radiation therapy (SBRT). Method and Materials: We propose a novel VMAT paradigm, Coll-VMAT, which integrates collimator rotation with synchronized gantry rotation, multileaf collimator (MLC) motion, and dose-rate modulation. At each gantry angle a principal component analysis (PCA) is applied to calculate the primary cord orientation. The collimator angle is then aligned so that MLC travel is parallel to the PCA-derived direction. An in-house VMAT optimization follows the geometry-based collimator trajectory optimization to obtain the optimal MLC position and monitor units (MU) at each gantry angle. A treatment planning study of five paraspinal SBRT patients compared Coll-VMAT to standard VMAT (fixed collimator angle) and static field IMRT plans. Plan evaluation statistics included planning target volume (PTV) V95%, PTV-D95%, cord-D05%, and total beam-on time. Results: Variation of collimator angle in Coll-VMAT plans ranges from 26 deg. to 54 deg., with a median of 40 deg. Patient-averaged PTV V95% (94.6% Coll-VMAT vs. 92.1% VMAT and 93.3% IMRT) and D95% (22.5 Gy vs. 21.4 Gy and 22.0 Gy, respectively) are highest with Coll-VMAT, and cord D05% (9.8 Gy vs. 10.0 Gy and 11.7 Gy) is lowest. Total beam-on time with Coll-VMAT (5,164 MU) is comparable to standard VMAT (4,868 MU) and substantially lower than IMRT (13,283 MU). Conclusion: Collimator trajectory optimization-based VMAT provides an additional degree of freedom that can improve target coverage and cord sparing of paraspinal SBRT plans compared with standard VMAT and IMRT approaches.

07 ISOTOPE AND RADIATION SOURCES↗

Online Adaptive Replanning Method for Prostate Radiotherapy

Purpose: To report the application of an adaptive replanning technique for prostate cancer radiotherapy (RT), consisting of two steps: (1) segment aperture morphing (SAM), and (2) segment weight optimization (SWO), to account for interfraction variations. Methods and Materials: The new 'SAM+SWO' scheme was retroactively applied to the daily CT images acquired for 10 prostate cancer patients on a linear accelerator and CT-on-Rails combination during the course of RT. Doses generated by the SAM+SWO scheme based on the daily CT images were compared with doses generated after patient repositioning using the current planning target volume (PTV) margin (5 mm, 3 mm toward rectum) and a reduced margin (2 mm), along with full reoptimization scans based on the daily CT images to evaluate dosimetry benefits. Results: For all cases studied, the online replanning method provided significantly better target coverage when compared with repositioning with reduced PTV (13% increase in minimum prostate dose) and improved organ sparing when compared with repositioning with regular PTV (13% decrease in the generalized equivalent uniform dose of rectum). The time required to complete the online replanning process was 6 {+-} 2 minutes. Conclusion: The proposed online replanning method can be used to account for interfraction variations for prostate RT with a practically acceptable time frame (5-10 min) and with significant dosimetric benefits. On the basis of this study, the developed online replanning scheme is being implemented in the clinic for prostate RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Functional MRI and White Matter Tractography in Stereotactic Radiosurgery Clinical Practice

Purpose: To study the efficacy of the integration of functional magnetic resonance imaging (fMRI) and diffusion tensor imaging tractography data into stereotactic radiosurgery clinical practice. Methods and Materials: fMRI and tractography data sets were acquired and fused with corresponding anatomical MR and computed tomography images of patients with arteriovenous malformation (AVM), astrocytoma, brain metastasis, or hemangioma and referred for stereotactic radiosurgery. The acquired data sets were imported into a CyberKnife stereotactic radiosurgery system and used to delineate the target, organs at risk, and nearby functional structures and fiber tracts. Treatment plans with and without the incorporation of the functional structures and the fiber tracts into the optimization process were developed and compared. Results: The nearby functional structures and fiber tracts could receive doses of >50% of the maximum dose if they were excluded from the planning process. In the AVM case, the doses received by the Broadmann-17 structure and the optic tract were reduced to 700 cGy from 1,400 cGy and to 1,200 cGy from 2,000 cGy, respectively, upon inclusion into the optimization process. In the metastasis case, the motor cortex received 850 cGy instead of 1,400 cGy; and in the hemangioma case, the pyramidal tracts received 780 cGy instead of 990 cGy. In the astrocytoma case, the dose to the motor cortex bordering the lesion was reduced to 1,900 cGy from 2,100 cGy, and therefore, the biologically equivalent dose in three fractions was delivered instead. Conclusions: Functional structures and fiber tracts could receive high doses if they were not considered during treatment planning. With the aid of fMRI and tractography images, they can be delineated and spared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗