Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable surface acoustic wave device using semiconducting MgZnO and piezoelectric NiZnO dual-layer structure on glass

Tunable surface acoustic wave (SAW) devices have attracted considerable interests due to its applications in emerging fields, such as secured wireless communication, adaptive signal processing, and smart sensing systems. We report a dual-input-voltage-controlled tunable SAW built on glass, which uses a ZnO-based dual-layer structure consisting of a piezoelectric Ni- doped ZnO (NZO) and semiconducting Mg-doped ZnO (MZO). The interdigital (IDT) electrodes are buried in the piezoelectric NZO layer to form the delay line for SAW propagation, while the semiconductor MZO layer serves as the channel of a thin film transistor (TFT) to modulate the conductivity. Results show the interface between MZO channel and SiO 2 gate dielectric layer of the TFTT significantly impacts on SAW tuning performances due to Zn diffusion from MZO into SiO 2 . The TFT-SAW device using an ultra-thin MgO layer as interface modification enables SAW frequency tuning of 0.53% under solely V gs control with 0–12 V. The required voltage range is significantly reduced compared regular MZO-NZO TFT-SAW counterpart (Δf/f c ~ 0.25%; V gs –30 to –14 V) without interface modification. With additional control of V ds , the SAW frequency tunability is further expanded from 0.46% to 0.63%. As a result, this dual-input voltage-controlled frequency tuning device on glass is promising for low-voltage, low-cost portable smart sensors and voltage-controlled reconfigurable radio-frequency identification tags.

36 MATERIALS SCIENCE↗

Note: On-line weak signal detection via adaptive stochastic resonance

We design an instrument with a novel embedded adaptive stochastic resonance (SR) algorithm that consists of a SR module and a digital zero crossing detection module for on-line weak signal detection in digital signal processing applications. The two modules are responsible for noise filtering and adaptive parameter configuration, respectively. The on-line weak signal detection can be stably achieved in seconds. The prototype instrument exhibits an advance of 20 dB averaged signal-to-noise ratio and 5 times averaged adjust R-square as compared to the input noisy signal, in considering different driving frequencies and noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A contactless approach for respiratory gating in PET using continuous-wave radar

Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a readout circuit incorporating a 12-bit analog-to-digital converter for cooled infrared focal plane array

The infrared focal plane array (IRFPA) is gradually becoming more systematic. In order to enhance the signal processing capabilities, analog-to-digital converters (ADC) integrated into the readout integrated circuit (ROIC) is an important development trend. However, the cryogenic effects of MOSFET devices will affect the conversion accuracy of the ADC at 77 K. In this paper, the main parameters of MOSFET are extracted at 77 K in 0.18 μm CMOS process, and a cryogenic model is established. Based on this, a digital ROIC is designed, which integrates a 12-bit single-slope integral ADC in pixel unit. By applying continuous integral ramp generator and mixed-voltage comparator, a high-linearity and low-power consumption single-slope ADC is realized for the cooled readout circuit. The measured dynamic effective number of bits of the ADC at 77 K is 10.92 bits, the static no-missing code resolution reaches 11.99 bits, the maximum differential nonlinear |DNL| < 1LSB and maximum integral nonlinear |INL| < 1LSB. This paper realizes the design of a digital ROIC for IRFPA and improves the simulation accuracy at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting multipartite classical states and their resemblances

We study various types of multipartite states lying near the quantum-classical boundary. The so-called classical states are precisely those in which each party can perfectly identify a locally held state without disturbing the global state, a task known as nondisruptive local state identification (NDLID). We show NDLID to be closely related local broadcasting, and we introduce a class of states called generalized classical states which allow for both NDLID and multipartite broadcasting when the most general quantum measurements are permitted. Simple analytical methods and a physical criterion are given for detecting whether a multipartite state is classical or generalized classical. For deciding the latter, a semidefinite programming algorithm is presented which may find use in other fields such as signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Organization of the Escherichia coli Chemotaxis Network Imaged with Super-Resolution Light Microscopy

The Escherichia coli chemotaxis network is a model system for biological signal processing. In E. coli, transmembrane receptors responsible for signal transduction assemble into large clusters containing several thousand proteins. These sensory clusters have been observed at cell poles and future division sites. Despite extensive study, it remains unclear how chemotaxis clusters form, what controls cluster size and density, and how the cellular location of clusters is robustly maintained in growing and dividing cells. Here, we use photoactivated localization microscopy (PALM) to map the cellular locations of three proteins central to bacterial chemotaxis (the Tar receptor, CheY, and CheW) with a precision of 15 nm. We find that cluster sizes are approximately exponentially distributed, with no characteristic cluster size. One-third of Tar receptors are part of smaller lateral clusters and not of the large polar clusters. Analysis of the relative cellular locations of 1.1 million individual proteins (from 326 cells) suggests that clusters form via stochastic self-assembly. The super-resolution PALM maps of E. coli receptors support the notion that stochastic self-assembly can create and maintain approximately periodic structures in biological membranes, without direct cytoskeletal involvement or active transport.

59 BASIC BIOLOGICAL SCIENCES↗

Noise Performance Evaluation of the Candidate Digitizers for the MAJORANA DEMONSTRATOR

The noise performance evaluation of the two digitizer cards being considered for the MAJORANA DEMONSTRATOR (MJD) is presented in this document. The procurement of the data acquisition electronics for the MJD is scheduled to happen this year. At the time of writing this document, there are two candidate digitizer electronic boards. One aspect that is being considered by the collaboration is the feasibility of using the MJD for dark matter searches. The feasibility of using the MJD for this application is going to be dictated by the ability of the demonstrator to reach sub-keV energy resolution. One of the potential sources of noise in the MJD is the data acquisition system. This document will is concluded with a recommendation for the final digitizer board by comparing the noise performance of the two electronics systems. Noise parameters such as the effective number of bits, input range linearity and signal to noise ratio are experimentally determined. The two digitizer cards feature different on-board digital signal processing and these features are compared. The experimental set-up was also used to identify sources of noise. This paper describes these sources of noise in the data acquisition system, along with mitigation strategies. Issues such as grounding and wiring scheme have an impact in the overall data acquisition system performance and are discussed in detail. As a conclusion, the suitability of each one of the cards to become the back bone of the data acquisition system of the MJD is discussed.

99 GENERAL AND MISCELLANEOUS↗

Research in Neutrinoless Double-Beta Decay (Final Report)

The research objective of the supported work was to search for neutrinoless double-beta decay in 76 Ge and investigate and identify backgrounds to a double-beta decay search. Understanding the neutrino mass generation mechanism, the absolute neutrino mass scale, the neutrino mass spectrum, and the possible Majorana nature of neutrinos are some of the future discoveries of the next generation neutrino experiments. The Majorana collaboration operated the Demonstrator experiment comprising 44 kg (30 kg enriched in 76 Ge) of Ge detectors in total split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Observation of 0νββ would have profound implications for the Standard Model of particle physics by demonstrating that neutrinos are Majorana particles, that lepton number is not conserved, and it would provide a measure of the effective Majorana neutrino mass. The decay rate of 0νββ is incredibly small and may only produce a few signature events in a detector per year. Therefore, observation of this rare process demands a careful study and implementation of signal processing, detector design, and new levels of background suppression.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An ultrasonic flowmeter for measuring dynamic liquid flow

A novel oscillating pipe system was developed to provide dynamic calibration wherein small sinusoidal signals with amplitudes of 0.5 to 10% of the steady-state flow were added to the steady-state flow by oscillating the flowmeter relative to the fixed pipes in the flow system. Excellent agreement was obtained between the dynamic velocities derived from an accelerometer mounted on the oscillating pipe system and those sensed by the flowmeter at frequencies of 7, 19, and 30 Hz. Also described were the signal processing techniques used to retrieve the small sinusoidal signals which were obscured by the fluid turbulence.

Carpini, T. D.↗

NASA's satellite relay tracking and data acquisition program

The Tracking and Data Acquisition System (TDAS) is currently being planned to support NASA missions and the Space Station and will serve as a replacement to the present Tracking and Data Relay Satellite System (TDRSS). Its operational date is currently projected for the late 1990s. Near term objectives involve the definition of a TDAS architecture, the development of functional and performance specifications and implementation of a TDRSS-to-TDAS transition plan. The present paper provides an overview of the baseline TDAS architecture and summarizes key ingredients of system and technology studies in progress. In particular, this paper addresses a summary of projected mission requirements for the TDAS era; a characterization of the space segment constellation; use of lasers, 60 GHz, and multibeam 30/20 GHz technologies; ground architecture and operational interfaces; a distributed hardware/software processing concept for more flexible and reliable interfaces, signal processing and operations. Also included is a status summary of the TDAS program plan for the 1984-1990 time frame. Finally, an overview is presented of NASA's current plans to augment the TDRSS to meet the Space Station IOC requirements in the time period 1993-2000.

Schwartz, J. J.↗

ACTS and OLYMPUS propagation experiments

The OLYMPUS and ACTS satellites both provide opportunities for 10 to 30 GHz propagation measurements. The spacecraft are sufficiently alike that OLYMPUS can be used to test some prototype ACTS equipment and experiments. Data are particularly needed on short term signal behavior and in support of uplink power control and adaptive forward error correction (FEC) techniques. The Virginia Tech Satellite Communications Group has proposed a set of OLYMPUS experiments including attenuation and fade rate measurements, data communications, uplink power control, rain scatter interference, and small-scale site diversity operation. A digital signal processing receiver for the OLYMPUS and ACTS beacon signals is being developed.

Bostian, Charles W.↗

Total hydrocarbon analysis by ion mobility spectrometry

Astronauts must be alerted quickly to chemical leaks that compromise their health and the success of their missions. An ideal leak detector would be equally sensitive to all compounds that might constitute a hazard and insensitive to nontoxic compounds. No ideal sensor exists; thus, selection of a methodology is a series of compromises. The commonly used methods are either insensitive at the low exposure levels set by OSHA, NASA, and other organizations or are selectively insensitive to important classes of chemicals such as Freons. After extensive study and experience, the Toxicology Group at JSC has selected ion mobility spectrometry (IMS) for development into a broad range, sensitive detector. In addition to the sensing method, signal processing is important leak detection because a background signal can be expected at all times. The leak-detecting instrument must be programmed to discriminate between authentic leaks and background fluctuations caused by routine operations. The results of an evaluation of the prototype THA is presented in terms related to spacecraft operations. The evaluation included determination of instrumental parameters such as stability and response times. We also included responses to some common components of spacecraft atmospheres in pure form and in binary and ternary mixtures. The output of the four algorithms to the mixtures was found to be noticeably different. These responses are compared on the basis of their utility for signaling a chemical leak. As a means of evaluating its resistance to a falsely positive response, the THA was challenged with carbon dioxide and methane, compounds whose concentrations normally increase in spacecraft air during human habitation. The instrument showed virtually no response to these interferences. Although the prototype THA is designed for space flight, this detector is expected to be useful for field screening at chemical waste dumps and other environmentally sensitive locations.

Cross, John H.↗

Methods and Apparatus for Reducing Multipath Signal Error Using Deconvolution

A deconvolution approach to adaptive signal processing has been applied to the elimination of signal multipath errors as embodied in one preferred embodiment in a global positioning system receiver. The method and receiver of the present invention estimates then compensates for multipath effects in a comprehensive manner. Application of deconvolution, along with other adaptive identification and estimation techniques, results in completely novel GPS (Global Positioning System) receiver architecture.

Kumar, Rajendra↗

Multimodal neuroelectric interface development

We are developing electromyographic and electroencephalographic methods, which draw control signals for human-computer interfaces from the human nervous system. We have made progress in four areas: 1) real-time pattern recognition algorithms for decoding sequences of forearm muscle activity associated with control gestures; 2) signal-processing strategies for computer interfaces using electroencephalogram (EEG) signals; 3) a flexible computation framework for neuroelectric interface research; and d) noncontact sensors, which measure electromyogram or EEG signals without resistive contact to the body.

Evaluation Studies↗