Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

A globally sampled high-resolution hand-labeled validation dataset for evaluating surface water extent maps

Effective monitoring of global water resources is increasingly critical due to climate change and population growth. Advancements in remote sensing technology, specifically in spatial, spectral, and temporal resolutions, are revolutionizing water resource monitoring, leading to more frequent and high-quality surface water extent maps using various techniques such as traditional image processing and machine learning algorithms. However, satellite imagery datasets contain trade-offs that result in inconsistencies in performance, such as disparities in measurement principles between optical (e.g., Sentinel-2) and radar (e.g., Sentinel-1) sensors and differences in spatial and spectral resolutions among optical sensors. Therefore, developing accurate and robust surface water mapping solutions requires independent validations from multiple datasets to identify potential biases within the imagery and algorithms. However, high-quality validation datasets are expensive to build, and few contain information on water resources. For this purpose, we introduce a globally sampled, high-spatial-resolution dataset labeled using 3 m PlanetScope imagery. Our surface water extent dataset comprises 100 images, each with a size of 1024×1024 pixels, which were sampled using a stratified random sampling strategy covering all 14 biomes. We highlighted urban and rural regions, lakes, and rivers, including braided rivers and coastal regions. We evaluated two surface water extent mapping methods using our dataset – Dynamic World, based on Sentinel-2, and the NASA IMPACT model, based on Sentinel-1. Dynamic World achieved a mean intersection over union (IoU) of 72.16 % and F1 score of 79.70 %, while the NASA IMPACT model had a mean IoU of 57.61 % and F1 score of 65.79 %. Performance varied substantially across biomes, highlighting the importance of evaluating models on diverse landscapes to assess their generalizability and robustness. Our dataset can be used to analyze satellite products and methods, providing insights into their advantages and drawbacks. Our dataset offers a unique tool for analyzing satellite products, aiding the development of more accurate and robust surface water monitoring solutions. The dataset can be accessed via https://doi.org/10.25739/03nt-4f29.

54 ENVIRONMENTAL SCIENCES↗

Stresses within rare-earth doped yttria-stabilized zirconia thermal barrier coatings from in-situ synchrotron X-ray diffraction at high temperatures

There is a growing interest for smart coatings that can be integrated into turbine engines for in-situ temperature measurements or health monitoring. The addition of rare-earth dopants into standard thermal barrier ceramic top coat materials is used to obtain luminescent coatings that enable spectral measurements, for real-time temperature or health monitoring. The thermomechanical performance and durability of such novel coating compositions in extreme environments still remains to be evaluated. Consequently, the ability to manufacture sensor coatings which present suitable thermal properties needs to be demonstrated. For this study, highly luminescent erbium and europium doped yttria-stabilized zirconia and state-of-the-art yttria-stabilized zirconia coatings manufactured by air plasma spray were characterized to determine the effects of the embedded rareearth dopants on coating internal strain and stress and to quantify and compare their high temperature response using synchrotron X-ray diffraction. In-situ depth-resolved strain measurements were performed at 15 μm intervals along the depth of the coatings to evaluate materials response at key locations, specifically at layer interfaces. In-plane stress was calculated for the coatings and a finite element model was implemented to supplement the results and enable further predictions. The results show that the sensor coatings that were manufactured in this work revealed only minor variations in the strain response of sensor coatings under a typical thermal cycle and especially at temperatures closer to that of gas turbine operating conditions, compared to state-of-the-art coatings. This work demonstrates the viability of manufacturing rare-earth doped yttria-stabilized zirconia coatings that provide beneficial spectroscopic monitoring capabilities while having minimal impact on the thermomechanical response of the thermal barrier coatings.

Air plasma spray↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

A study of mechanoelectrical transduction behavior in polyvinyl chloride (PVC) gel as smart sensors

Abstract Polyvinyl chloride (PVC) gels are soft electroactive polymers (EAPs) being researched for soft robotic applications. Sensing properties of these EAPs have not been investigated in detail in regard to fundamental mechanoelectrical transduction behavior, but this smart material has been shown to exhibit a detectable response to external stimuli. This study shows PVC gels to be an extremely sensitive material when undergoing mechanoelectrical transduction and explores some response dependencies and proposes a theoretical framework for mechanoelectrical transduction within the gel. The work presented here also uncovers a very interesting phenomena under extremely low compressive loads during the initial contact with the gel. This phenomenon is attributed to a surface tension creeping motion onto the loading surface with an accompanying polarity inversion in the sensing signal relative to fully loaded gels in compression. Experimental work on hysteresis was also completed showing very little memory in steady state mechanoelectrical response to repeated stepped loading cycles. This study demonstrates the mechanoelectric ability of PVC gels to perform in sensing experiments and acts as a fundamental framework to further broaden the applications of PVC gel sensors.

Instruments & Instrumentation↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

Boosting Electrochemical Catalysis and Nonenzymatic Sensing Toward Glucose by Single‐Atom Pt Supported on Cu@CuO Core–Shell Nanowires

Abstract It is critical to develop high‐performance electrocatalyst for electrochemical nonenzymatic glucose sensing. In this work, a single‐atom Pt supported on Cu@CuO core–shell nanowires (Pt 1 /Cu@CuO NWs) for electrochemical nonenzymatic glucose sensor is designed. Pt 1 /Cu@CuO NWs exhibit excellent electrocatalytic oxidation toward glucose with 70 mV lower onset potential (0.131 V) and 2.4 times higher response current than Cu NWs. Sensors fabricated using Pt 1 /Cu@CuO NWs also show high sensitivity (852.163 µA mM −1 cm −2 ), low detection limit (3.6 µM), wide linear range (0.01–5.18 µM), excellent selectivity, and great long‐term stability. The outstanding sensing performance of Pt 1 /Cu@CuO NWs, investigated by experiments and density functional theory (DFT) calculations, is attributed to the synergistic effect between Pt single atoms and Cu@CuO core–shell nanowires that generates strong binding energy of glucose on the nanowires. The work provides a new pathway for exploring highly active SACs for electrochemical nonenzymatic glucose sensor.

Chemistry↗

Process Anomaly Detection for Sparsely Labeled Events in Nuclear Power Plants

An essential aspect of online monitoring, subtle anomaly detection increases the detection lead time for equipment failure and enables a nuclear power plant (NPP) to mitigate unexpected partial or full outages, resulting in significant cost saving to the plant. Once an anomaly is detected by plant staff, its cause and severity are investigated. Because the vast majority of anomalies require some level of investigation, including some that require time-consuming examination, before they are passed over to the engineering organization for further analysis, plants are often equipped with tools to assist the staff in performing anomaly detection. Those tools operate as a black box and are often based on statistical methods that establish sensor correlations using preconfigured mathematical models and flag correlation deviations as anomalies. Due to the number of anomalies detected at a given NPP on a daily basis, a significant number of flagged anomalies usually await examination for days or weeks. A primary cause of this backlog is that the methods used by the tools generate many false positives. Though this is usually attributed to oversensitive model settings due to very narrow normal operation bands, it can also be associated with the model development being inadequate for the process being monitored, or with missing model inputs that could have explained misclassified positives. The performance of anomaly detection tools impacts their plant acceptance and utilization, especially when the effort to address false positives generated by the tool depletes the value or cost saved by using that tool. Thus, means to advance anomaly detection performance have been investigated by the Department of Energy’s Light Water Reactor Sustainability program. Previous and ongoing efforts have targeted unsupervised machine-learning (ML) methods, which do not require the labeling of any data fed into the ML model. By contrast, in supervised anomaly detection methods, every data point is labeled as either a normal or abnormal process condition, and the model is trained to replicate the classification process. Supervised methods usually outperform unsupervised methods, due to the added value in differentiating normal from anomalous states of the monitored process. An NPP’s corrective action program requires it to track and document, via a dedicated report, the resolution of any issues that occur within the plant. Once created, each report is reviewed by a plant screening committee, and several classifications and decisions are made. Recently, a collaborating NPP developed an artificial intelligence and ML-based classifier to categorize a condition report (CR) into classes that can serve to label the data as normal or anomalous. Applying CRs as labels represents a semi-supervised use case. Semi-supervised ML assumes that labels exist for some data points (i.e., labeled anomalies, in this case) but not for the rest. In this effort, semi-supervised ML methods were used to fuse data from CRs with anomaly detection methods in order to test the hypothesis that partially labeled anomalies would improve the accuracy of the anomaly detection methods. Specifically, two methods were used. The first is the deep Semi-supervised Anomaly Detection (deep SAD) method, which can handle labels ranging from fully unsupervised to fully supervised cases. The second is a newly designed ML method developed specifically for this effort and referred to as the high-order feature (HOF)-based method. To evaluate these two methods in controlled environments, synthetic data generators were developed and used. The first datasets used a spring-mass-damper (SMD) system simulator commonly found in mechanical engineering references. This was used to create two use cases: a one- and a three-mass system. Anomalies were introduced by changing the spring and damper coefficients while the system was actuated by random forces. The second datasets used the commercial Dymola-Modelica software to build a simplified nuclear reactor model. Anomalies were added in the form of corrupted sensor readings and/or control commands. The deep SAD method was tested using the SMD system, while the HOF method was tested using both datasets. Application of the deep SAD semi-supervised ML method demonstrated that labels can generate increased confidence in detecting true anomalies. This helped increase the number of true positives and decrease the number of false negatives—something that would aid in addressing the backlog of possible anomalies. Application of the HOF method demonstrated that labels can aid in down selecting from a candidate set of features to a more optimal subset in order to better differentiate between normal and anomalous conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Displacement driven balancing of a diamond turning machine flycutter

The spindle balancing operation is critical to the performance of precision lathes and should be conducted anytime the configuration of the spindle or its tooling is modified such that an unbalanced condition may occur. Within the machine tool community, accelerometers are typically used as the feedback device during the balancing operation. At Lawrence Livermore National Laboratory (LLNL), we have nearly 40 years of history using displacement sensors, such as capacitance gauges, in place of accelerometers when balancing precision spindles. The process of balancing a precision machine spindle using displacement sensors is presented in the context of two work examples. In this case, the details of the one-dimensional balancing operation performed after replacing a flycutter on the spindles of two unique large optic diamond turning machines is discussed. The pros and cons of accelerometer driven balancing and displacement driven balancing are also presented. In the accelerometer context, the level of balance achieved for our work example is less than 100 micro-g or a total indicator reading (TIR) of 1.6 µm. The process of balancing has been enhanced over the years as advances have been made in software, data acquisition systems, and instrumentation. The balancing system is described including details about instrumentation, set-up, how phase and spindle structure stiffness is calculated, and how the LLNL developed software that guides the user through the process by suggesting corrective action.

42 ENGINEERING↗

Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

The Simons Observatory: Design, Optimization, and Performance of Low-Frequency Detectors

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment located in the Atacama Desert in Chile that will make precise temperature and polarization measurements over six spectral bands ranging from 27 to 285 GHz. Three small aperture telescopes (SATs) and one large aperture telescope (LAT) will house ~60,000 detectors and cover angular scales between one arcminute and tens of degrees. We present the performance of the dichroic, low-frequency (LF) lenslet-coupled sinuous antenna transition-edge sensor (TES) bolometer arrays with bands centered at 27 and 39 GHz. The LF focal plane will primarily characterize Galactic synchrotron emission as a critical part of foreground subtraction from CMB data. We will discuss the design, optimization, and current testing status of these pixels.

79 ASTRONOMY AND ASTROPHYSICS↗

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗