Use of Machine Learning with On-Line Monitoring Systems for Reprocessing.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Presentation of NNSS Drinking Water and Wastewater 2021 monitoring
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A method of making an optical fiber sensor device for distributed sensing includes generating a laser beam comprising a plurality of ultrafast pulses, and focusing the laser beam into a core of an optical fiber to form a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to a longitudinal axis of optical fiber. Also, an optical fiber sensor device for distributed sensing includes an optical fiber having a longitudinal axis, a core, and a nanograting structure within the core, wherein the nanograting structure includes a plurality of spaced nanograting elements each extending substantially parallel to the longitudinal axis of the optical fiber. Also, a distributed sensing method and system and an energy production system that employs such an optical fiber sensor device.
A reference electrode includes a metal body, a lead disposed within the metal body, an insulator disposed between the lead and the metal body, the insulator including a ceramic material, and a porous metal chamber coupled to the metal body, the lead extending into the porous metal chamber. The porous metal chamber is configured to maintain an electrolyte solution within the porous metal chamber to establish a redox couple with the lead.
Abstract not provided.
This paper presents a computational method for the helium leakage from a canister. The governing equations for compressible fluids consist of mass conservation equation in Eulerian description, momentum equations and energy equation. The numerical procedures are divided into three phases, advection, diffusion and acoustic phases, and the equations of compressible fluids are discretized with a finite volume method. Thus, the mass conservation law is sufficiently satisfied in the calculation region. In particular, our computational method enables us to predict the change of the temperature distributions around the canister boundaries by calculating the governing equations for the compressible gas flows, which are leaked out from a slight crack on the canister boundary. In order to confirm the validity of our method, it was applied to the basic problem, 2-dimensional natural convection flows in a rectangular cavity. As a result, it was shown that the naturally convected flows can be reasonably simulated by our method. Furthermore, numerical experiments were conducted for the helium leakage from canister and we derived a close relationship between the inner pressure and the boundary temperature distributions.
In the context of Chinese (TSN) EPR reactors project, a new on-line support system was introduced to give information, either continuously or upon request, to the plant operators about some advanced physics parameters corresponding to the current state of the nuclear core. This document provides a description of the functions that are available and the advantages provided by using their results. For each function the Human Machine Interface (HMI) is illustrated. (authors)
A plastic scintillator performance for an in-situ measurement system was analyzed using both simulation and experimental methods. The measurement results of four major pure beta-emitting radionuclides - namely H-3. C-14, P-32 and Sr-90/Y-90 - were compared with those from a Monte Carlo N-particle (MCNP) code simulation. Good agreement between the simulation and experimental results was observed for P-32 and Sr-90/Y-90. However, due to the short range of their beta particles in water, the efficiency for both H-3 and C-14 was rather low, and these radionuclides could not be detected. The optimal thickness for the plastic scintillator was identified, as was its suggested diameter. The effect of water depth on system performance was also considered. (authors)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An automatic, self-contained device for detecting toxic agents in a water supply includes an analyzer for detecting at least one toxic agent in a water sample, introducing a means for introducing a water sample into the analyzer and discharging the water sample from the analyzer, holding means for holding a water sample for a pre-selected period of time before the water sample is introduced into the analyzer, and an electronics package that analyzes raw data from the analyzer and emits a signal indicating the presence of at least one toxic agent in the water sample.