Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Space station contamination modeling

Current plans for the operation of Space Station Freedom allow the orbit to decay to approximately an altitude of 200 km before reboosting to approximately 450 km. The Space Station will encounter dramatically increasing ambient and induced environmental effects as the orbit decays. Unfortunately, Shuttle docking, which has been of concern as a high contamination period, will likely occur during the time when the station is in the lowest orbit. The combination of ambient and induced environments along with the presence of the docked Shuttle could cause very severe contamination conditions at the lower orbital altitudes prior to Space Station reboost. The purpose here is to determine the effects on the induced external environment of Space Station Freedom with regard to the proposed changes in altitude. The change in the induced environment will be manifest in several parameters. The ambient density buildup in front of ram facing surfaces will change. The source of such contaminants can be outgassing/offgassing surfaces, leakage from the pressurized modules or experiments, purposeful venting, and thruster firings. The third induced environment parameter with altitude dependence is the glow. In order to determine the altitude dependence of the induced environment parameters, researchers used the integrated Spacecraft Environment Model (ISEM) which was developed for Marshall Space Flight Center. The analysis required numerous ISEM runs. The assumptions and limitations for the ISEM runs are described.

Gordon, T. D.↗

High resolution measures of polarization and color of selected lunar areas

High resolution observations of intensity, color (UBV) and polarization were obtained with scanning techniques for a number of lunar areas of special interest, including boundaries of some of the brightest and darkest lunar regions, certain Apollo landing sites and prominent craters. Two dimensional raster scans of colors were obtained for Alphonsus, Aristarchus, and Herodotus. The degree of polarization for any given phase angle appears to be roughly indicative of age. The darker younger mare surface are more highly polarized than the lighter and older mare surfaces, which appear to be more contaminated by lighter material from the highlands or by ray material thrown out from fresh craters. All mare surfaces are more highly polarized than the still older and lighter terra regions surrounding the maria. The very oldest craters are either dark-floored and show polarization characteristics similar to those of the mare surfaces, or if located in the highlands, they are less and less distinguishable from the highland background with greater age, and show the general highland polarization characteristics.

Riley, L. A.↗

Elimination of directional wave spectrum contamination from noise in elevation measurements

The Surface Contour Radar (SCR) is a 36-GHz computer-controlled airborne radar which generates a false-color-coded elevation map of the sea surface below the aircraft in real time, and can routinely produce ocean directional wave spectra with post-flight data processing which have much higher angular resolution than pitch-and-roll buoys. The SCR range measurements are not error-free and the resulting errors in the elevations corrupt the directional wave spectrum. This paper presents a technique for eliminating that contamination.

Walsh, E. J.↗

Qualification of the gritblast assembly and process for the inside diameter of the RSRM forward and aft domes

This gritblast assembly shall be used when refurbishing the Inside Diameter (ID) of RSRM forward and aft domes. Initial blasting is used to remove corrosion and adhesive not removed during the insulation washout. Final blasting is conducted just prior to part finalization in order to remove residual contamination and prepare the ID surface for bonding. The media used in this gritblaster is DuPont Zirclean Blasting Abrasive. It is possible to use other media in this gritblast assembly, however the only facility that has the control capability for this assembly is the Zirclean blast booth. This blast booth can not use other media without the occurrence of contamination. This automated process shall replace the manually controlled gritblasting that is currently in operation. Manual gritblasting does not provide the consistency, control, and safety that an automated process is capable of delivering.

Nolan, Michael J.↗

Investigating the Performance of the Jason-2/OSTM Radar Altimeter Over Lakes and Reservoirs

Many inland water investigations utilize archival and near-real time radar altimetry data to enable observation of the variation in surface water level. A multi-altimeter approach allows a more global outlook with improved spatial resolution, and combined long-term observations improve statistical analyses. Central to all programs is a performance assessment of each instrument. Here, we focus on data quantity and quality pertaining to the Poseidon-3 radar altimeter onboard the Jason-2/OSTM satellite.Utilizing an interim data set (IGDR), studies show that the new on-board DIODE/median and DIODE/DEM tracking modes are performing well, acquiring and maintaining the majority of lake and reservoir surfaces in varying terrains. The 20-Hz along-track resolution of the data, and particularly the availability of the range output from the ice-retracker algorithm, also improves the number of valid height measurements. Based on test-case lakes and reservoirs, output from the ice-retracker algorithm is also seen to have a clear advantage over the ocean-retracker having better height stability across calm and icy surfaces, a greater ability to gain coastline waters, and less sensitivity to loss of water surface when there is island contamination in the radar echo. Such on-board tracking and postprocessing retracking enables the lake waters to be quickly gained after coastline crossing. Values can range from <0.1 s to 2.5 s, but the majority of measurements are obtained in less than 0.4 s or <2.3 km from the coast. Validation exercises reveal that targets of 150 km2 surface area and 0.8 km width are able to be monitored offering greater potential to acquire lakes in the 100 C300 km2 size-category. Time series of height variations are also found to be accurate to 3 to 33 cm rms depending on target size and the presence of winter ice. These findings are an improvement over the IGDR/GDR results from the predecessor Jason-1 and TOPEX/Poseidon missions and can satisfy the accuracy requirements of both the science-related and operational lake study programs.

Birkett, C. M.↗

Development of a new class of chemical and biological ultrasensors: Ribonuclease contamination and control

In order to define ribonuclease contamination, an assay for ribonuclease having picogram level sensitivity was established. In this assay, polycytidylic acid is digested by ribonuclease leading to smaller fragments of poly C that remain soluble after treatment of the sample with perchloric acid and lanthanum acetate. An absorbance measurement at 260 nm of the supernatant from the centrifuged sample measures the ribonuclease. A standard curve is shown. Using this assay procedure, ribonuclease contamination was found to be significant in routine laboratory proteins, in particular, bovine serum albumin, lysozyme, catalase, and cytochrome C. This was confirmed by demonstrating a considerable reduction in this activity in the presence of phosphate buffer since phosphate inhibits ribonuclease. Ribonuclease contamination was not significantly encountered in routine laboratory glassware, plasticware, column surfaces, chromatographic particles, and buffer reagents, including airborne contamination. Some contamination could be introduced by fingerprints, however.

Source record↗

Compatibility of grain-stabilized platinum with candidate propellants for resistojets

An examination is conducted into the suitability of grain-stabilized Pt as a resistojet thruster material for Space Station auxiliary propulsion. A series of 1000-hour tests was conducted in CO2, H2, and NH3 at 1400 C; another series was conducted at 500 C in CH4 for the same duration. SEM, Auger electron microscopy, and depth profiling analysis were used to determine the effects of propellants on the material surface as well as to evaluate possible material contamination and possible grain growth. Carbon deposition is noted on the surface of Pt/Y2O3 and Pt/ZrO2 in both the CO2 and CH4 environments.

Whalen, M. V.↗

A study of molecular contamination

Contamination kinetics of typical space materials were studied using several techniques, including ellipsometry. Data were obtained on contaminant deposition rates, sticking coefficients, and reevaporation of the contamination. Materials studied included silicone sealants, a thermal control paint, and a graphite laminate as contaminant sources, and gold coated surfaces, a thermal control paint and a second surface mirror material as the contaminees. Both deposition and reevaporation rates were found to be nonlinear with time, and followed an exponential decay. A hypothesis is presented that the nonlinear behavior was a result of disproportionation of the molecular weight fractions of the polymers. The measured sticking coefficients were found to vary substantially with temperature over narrow ranges. Simulated space radiation was found to reduce the evaporation rates of contaminants by several orders of magnitude.

Allen, T. H.↗

Development of a Comprehensive Physics-Based Model for Study of NASA Gateway Lunar Dust Contamination

NASA is committed to landing the first woman and first person of color on the Moon by 2025 to begin a sustaining presence. A major component of this mission is NASA’s orbiting lunar outpost, Gateway, that will be subjected to the harsh environment of space during its 7-day orbit around the Moon. One aspect of this environment that is not well quantified is microscopic lunar regolith particles, or simply, lunar dust. As Apollo 17 Mission Commander Eugene Cernan said, “I think dust is probably one of our greatest inhibitors to a nominal operation on the moon. I think we can overcome other physiological or physical or mechanical problems except dust” [1]. These dust particles, most of which are smaller than the width of two human hairs and of highly irregular shape, are composed mainly of dielectric materials. Such characteristics can allow the dust particles to collect electric charge from the surrounding environment, resulting in electrostatic interactions between the dust, electromagnetic fields, and electrically charged surfaces [2-3]. Due to the nature of these fields, dust can collect on and contaminate charged surfaces. Lunar dust introduced into the Gateway environment by a lunar ascent vehicle element returning from the surface of the Moon presents risks to Gateway hardware such as radiators, solar arrays, antennae, and docking mechanisms. To quantify this risk and inform NASA, International Partner, and Commercial Provider stakeholders, Booz Allen, in partnership with NASA, is developing a toolset to model the interaction of charged lunar dust particles with the cis-lunar and deep-space environments. This includes a comprehensive physics model of the space plasma and solar radiation environment and electromagnetic interaction of spacecraft and lunar dust. Spacecraft charging and plasma environment are solved using the open-source code from The French Aerospace Lab (ONERA) and the European Space Agency (ESA), known as Spacecraft Plasma Interaction Software (SPIS) [4]. The physics of particle charging and motion is handled by a time-dependent implementation of Orbital-Motion-Limited (OML) theory which accounts for plasma flows and positive potential grains [5-7], using Siemens STAR-CCM+ as the framework. Model validation includes lab experiments by NASA experts and academia, as well as future on-orbit dust detecting payloads on the exterior of Gateway and Commercial Lunar Payload Services (CLPS) missions to the lunar surface [7-9]. The results and analyses will inform Gateway Program system owners at risk for lunar dust contamination.

Complex Plasma↗

Protective Coating Enhances the Durability of Retroreflectors for the International Space Station

Corner cube reflectors (retroreflectors) will be used on the International Space Station to aid in rendezvous and docking. They are designed to reflect light, such as that from a laser, directly back to the source. The resulting bright reflection from the surface can be used for critical alignment purposes. The housing for the reflectors is composed of polyoxymethylene, a polymer known as Delrin (DuPont), which is highly susceptible to erosion by the atomic oxygen environment that surrounds the station. Atomic oxygen is highly chemically reactive and will convert polymers such as Delrin into volatile oxidation products. This could cause the reflectors to detach from the housing or could cause volatile products and other contamination to recondense onto the surface of the reflectors, causing them to darken. The NASA Lewis Research Center is applying their patented fluoropolymer-filled silicon dioxide coating to the surface of the Delrin retroreflector to prevent degradation in performance caused by reactions with atomic oxygen.

Rutledge, Sharon K.↗

Application of the complex cepstrum to the location of acoustic sources near reflective surfaces

The complex cepstrum is used to correct bearing estimations of acoustic sources in the presence of a reflective surface. An automated liftering procedure is used which zeros out a block portion of the cepstrum including the echo information. The problem of the resulting distortion is alleviated by applying a coherence criterion to the recovered direct signals at each microphone. Thus to a large degree the interactive nature of cepstral processing is overcome for this application. For the test signals and geometries considered the cepstrum is shown to accurately correct for bearing errors in acoustic signals contaminated with reflections from nearby surfaces.

Fuller, C. R.↗

Blind to Chemistry: Molecular Contaminant Films We Could Be Missing During Visual Inspections and the Potential Impact to System Performance

Throughout the assembly, integration and test process, molecular contamination levels of space mission hardware are monitored to meet system performance requirements. Qualitatively, reflective surfaces and witness mirrors are continuously inspected for the visible presence of molecular contaminant films. Quantitatively, periodic reflectance measurements of witness mirrors indicate changes of mirror reflectivity over time due to the accumulation of molecular contaminant films. However, both methods only consider the presence of a contaminant film and not the molecular composition. Additionally, there is a risk that hardware may appear to be “visibly clean” even with a molecular contaminant film present on critical surfaces. To address these issues, experiments were performed to quantify the maximum molecular contaminant film that could be missed in visual inspections on witness mirrors with five different contaminants present. The corresponding changes in mirror reflectivity were modeled using the program STACK to determine the impact to space mission hardware performance. The results of this study not only show the criticality in considering the chemical make-up of molecular contaminant films on system performance, but also the need to recognize and understand the limitations of traditional visual inspection techniques on detecting molecular contaminant films.

Seasly, Elaine↗

Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Metal Surfaces for Planetary Protection

To prevent forward contamination from microbes aboard spacecraft intended to search for extraterrestrial life, there is a need for effective sterilization methods. However, current techniques are both time-consuming and expensive. For example, dry heat sterilization requires removal from the assembly site and several days of treatment. Furthermore, some components such as optics and electronics are not compatible with current sterilization techniques. Here, we report the latest results in our development of a novel femtosecond laser processing technique for the rapid sterilization of spacecraft hardware. Femtosecond lasers produce extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. Aluminum coupons were inoculated with specific densities of Bacillus subtilis bacterial endospores. These coupons were treated with various laser illumination parameters. Afterward, metal coupon samples were assayed for viable spores using a polyvinyl alcohol (PVA) peel, serial dilution, and plating for colony-forming units (CFU). Results indicate that with high enough energy density and pulse counts, most bacterial spores are inactivated with minimal damage to the metal. The sterilization is dependent on both the fluence and pulse count. In addition, femtosecond pulses are more effective than longer pulses for inactivation. These experiments have consistently achieved 4-log reduction in viable spores. Sterilization has been achieved on both flat metal coupons and non-flat surfaces with microchannels, with a slight reduction in sterilization efficiency on the uneven surface. The application of air flow during laser processing was also investigated as a way to remove spores that are dislodged from the surface by the laser illumination, which would contribute to the reduction of spacecraft bioburden. With laser processing technology rapidly evolving, our results support the possibility of an extremely rapid, in-situ surface sterilization method for use in spacecraft assembly clean rooms.

Kaleb McQuillan↗

X-Ray Photoelectron Spectroscopy Study of the Effect of Hydrocarbon Contamination on Poly(Tetrafluoroethylene) Exposed to a Nitrogen Plasma

It has been shown that unless the surface of poly(tetrafluoroethylene)(PTFE) is free of hydrocarbon contamination, anomalous changes in the oxygen and fluorine contents, as measured by X-ray photoelectron spectroscopy (XPS), and hence also the surface properties, may be improperly ascribed to a PTFE film exposed to a oxygen plasma.

Golub, Morton A.↗

Analysis of CO2 Composite Spray Cleaning System Results

In a previous study, the cleaning efficiency of a CO2 composite cleaning system for particulate removal was tested. The study covered particles from spores to fluorescent particles of different sizes as well as a variety of substrate surfaces, including aluminum, titanium, stainless steel, and nitinol. Particles were deposited using aerosol (dry) and droplet (wet) deposition. Results from the previous study show that the CO2 composite spray system is capable of cleaning to sterility for aerosol deposited spores and is capable of cleaning a minimum of a 4-log reduction for droplet deposited spores. This minimum 4-log reduction matches current Planetary Protection dry heat microbial reduction requirements. In this paper we will present new data to further correlate the cleaning efficiency with how contamination was introduced to the surface, the surface roughness, and particle size. Possible causes for such correlations will be discussed.

Chung, Shirley↗

Accuracy Assessment of Aqua-MODIS Aerosol Optical Depth Over Coastal Regions: Importance of Quality Flag and Sea Surface Wind Speed

Coastal regions around the globe are a major source for anthropogenic aerosols in the atmosphere, but the underlying surface characteristics are not favorable for the Moderate Resolution Imaging Spectroradiometer (MODIS) algorithms designed for retrieval of aerosols over dark land or open-ocean surfaces. Using data collected from 62 coastal stations worldwide from the Aerosol Robotic Network (AERONET) from approximately 2002-2010, accuracy assessments are made for coastal aerosol optical depth (AOD) retrieved from MODIS aboard Aqua satellite. It is found that coastal AODs (at 550 nm) characterized respectively by the MODIS Dark Land (hereafter Land) surface algorithm, the Open-Ocean (hereafter Ocean) algorithm, and AERONET all exhibit a log-normal distribution. After filtering by quality flags, the MODIS AODs respectively retrieved from the Land and Ocean algorithms are highly correlated with AERONET (with R(sup 2) is approximately equal to 0.8), but only the Land algorithm AODs fall within the expected error envelope greater than 66% of the time. Furthermore, the MODIS AODs from the Land algorithm, Ocean algorithm, and combined Land and Ocean product show statistically significant discrepancies from their respective counterparts from AERONET in terms of mean, probability density function, and cumulative density function, which suggest a need for future improvement in retrieval algorithms. Without filtering with quality flag, the MODIS Land and Ocean AOD dataset can be degraded by 30-50% in terms of mean bias. Overall, the MODIS Ocean algorithm overestimates the AERONET coastal AOD by 0.021 for AOD less than 0.25 and underestimates it by 0.029 for AOD greater than 0.25. This dichotomy is shown to be related to the ocean surface wind speed and cloud contamination effects on the satellite aerosol retrieval. The Modern Era Retrospective-Analysis for Research and Applications (MERRA) reveals that wind speeds over the global coastal region 25 (with a mean and median value of 2.94 meters per second and 2.66 meters per second, respectively) are often slower than 6 meters per second assumed in the MODIS Ocean algorithm. As a result of high correlation (R(sup 2) greater than 0.98) between the bias in binned MODIS AOD and the corresponding binned wind speed over the coastal sea surface, an empirical scheme for correcting the bias of AOD retrieved from the MODIS Ocean algorithm is formulated and is shown to be effective over the majority of the coastal AERONET stations, and hence can be used in future analysis of AOD trend and MODIS AOD data assimilation.

Anderson, J. C.↗