Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STEAM SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Comparative net energy ratio analysis of pellet produced from steam pretreated biomass from agricultural residues and energy crops

Here, a process model was developed to determine the net energy ratio (NER) for production of pellets from steam pretreated agricultural residue (AR) and energy crop (i.e. switchgrass in this case). The NER is a ratio of the net energy output to the total net energy input from non-renewable energy sources into a system. Scenarios were developed to measure the effects of temperature and level of steam pretreatment on the NER of steam pretreated AR- and switch grass-based pellets. The NER for the base case at 6 kg h -1 is 1.76 and 1.37 for steam-pretreated AR- and switchgrass-based pellets, respectively. The reason behind the difference is that more energy is required to dry switchgrass pellets than AR pellets. The sensitivity analysis for the model shows that the optimum temperature for steam pretreatment is 160 C with 50% pretreatment (half the feedstock is pretreated, while the rest is undergoes regular pelletization). The uncertainty results for NER for steam pretreated AR and switch grass pellets are 1.62 ± 0.10 and 1.42 ± 0.11, respectively.

09 BIOMASS FUELS↗

Verification of Analytical Test Based Thermohydraulic Systems Codes for One- and Two-Phase Liquid-Metal Flows

This work is devoted to the development of a system of analytical tests for verification of the thermohydraulic codes used in modeling the flow of one- and two-phase flows of liquid metals. The change of temperature in constant and variable flow of coolant, effect of axial heat conduction of the coolant on the temperature distribution, development of natural circulation in a closed loop, motion of a two-phase mixture under gravity, and fluctuations of the gas volume and distribution of the true process steam content in the presence of boiling/condensation are studied. The developed system of tests was used to verify the HYDRA-IBRAE/LM thermohydraulic code and the thermohydraulic module of the SOKRAT-BN code. The computational errors in the individual thermohydraulic parameters are obtained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Packaged Combined Heat and Power Technology Overview and Market Profile

Combined heat and power (CHP), sometimes referred to as cogeneration, is an efficient and clean approach to generating electric power and useful thermal energy onsite from a single fuel source, offering reliable and affordable energy services to businesses and institutions. Furthermore, CHP provides a cost effective opportunity to improve the environmental footprint and resilience of industrial and commercial facilities across the United States. CHP equipment can be custom-engineered or installed as a predesigned and assembled package. A packaged CHP system is a standardized, pre-engineered system that includes all equipment, piping, wiring, and ancillary components to deliver electricity and thermal energy to a host facility with minimal onsite engineering and design time. Packaged CHP systems can be shipped as single or multiple modules with standard interconnections (e.g., fuel; electrical; thermal—hot water, steam, and/or chilled water), which simplifies installation and reduces the costs associated with the project. Most containerized or single packaged CHP system offerings range from 10 kW to 3 MW in capacity. Packaged CHP systems are extending the operating, efficiency, and emissions benefits of CHP to nontraditional markets in commercial, institutional, multifamily, light manufacturing, government, and military applications. These markets tend to be served by smaller systems (less than 5 MW) that are conducive to pre-engineered packaging and/or modularization. Many of these sectors have limited CHP experience and technical resources to adequately evaluate, install, and maintain onsite CHP systems. The introduction of packaged CHP offerings from experienced CHP Packagers and Solution Providers has accelerated CHP adoption, lowered energy costs, reduced emissions, and strengthened energy resilience in these sectors. In 2019, the US Department of Energy (DOE) launched the Packaged CHP eCatalog to promote increased acceptance of efficient, cost-effective CHP in these applications. The Packaged CHP eCatalog is a web-based, searchable platform that hosts DOE-recognized packaged CHP systems with features designed to reduce economic and performance risks for designers, developers, owners, and facility operators interested in installing CHP. DOE established the Packaged CHP Accelerator at the same time to help launch and publicize the eCatalog, and to validate project performance, cost, and installation time of CHP packages across a variety of applications. Accelerator efforts documented installed cost reductions and installation time reductions of more than 20% for packaged CHP systems over 100 kW compared with custom-engineered systems. The Packaged CHP Accelerator and eCatalog established a peer-to-peer network connecting public and private sector partners including utilities, state energy offices, and energy efficiency program administrators interested in promoting cost-effective, efficient CHP systems, Packagers, and Solution Providers. Feedback from these partners, along with input from DOE’s CHP Technical Assistance Partnerships (CHP TAPs), was critical in understanding the current market for packaged CHP technologies, stimulating investment in these technologies, and guiding future directions for packaged CHP systems and their applications. This report provides background on packaged CHP systems, an overview of their benefits, a profile of current packaged CHP installations, and a summary of future market trends; this report is intended for facility owners, project developers, engineers, policymakers, and other stakeholders looking to increase the adoption of efficient, flexible, and resilient packaged CHP systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methods identifying cost reduction potential for water electrolysis systems

The electrochemical reduction of water to form hydrogen is an emerging alternative for energy storage, where hydrogen can be used as a transportation fuel, combusted to generate electricity, utilized in a fuel cell, or used as a feedstock for chemical synthesis. Techno-economic analysis (TEA) is a valuable tool for understanding how to inform research directions that could make hydrogen from electrolysis cost competitive with that produced by conventional means like steam methane reforming. The current state of knowledge on TEA of electrolysis systems suggests cost reductions are likely to result from advances in system design and materials, scale-up of manufacturing processes, and learning by doing effects as electrolysis deployment increases. Future directions and opportunities for TEA of electrolysis systems include dispatchable operation in wholesale power markets, optimization of capital cost and system durability, and analysis of pathways for hydrogen to support economy-wide decarbonization.

08 HYDROGEN↗

Computation of Air Discharge into a Water Pool by Using Volume-of-Fluid Method

Suppression tanks, in-containment refueling water storage tanks (IRWSTs) and filtered containment venting systems (FCVSs) of nuclear power plants use water pools to accommodate high-pressure and high-temperature discharge of non-condensable gases and/or steam. Dynamic behavior of gas bubbles inside a water pool determines pressure and temperature loading to the system and thus we need validated method for applications. The underlying physics relevant to these problems is still a difficult issue due to the complicated nature of gas- liquid interfacial transfers of mass, momentum, and energy in a two-phase flow. Therefore, notwithstanding many studies performed over the past two or three decades, two-fluid theory is still a formidable task and direct numerical simulation (DNS) needs huge computing cost. Pellegrini et al. analyzed steam condensation and chugging in the water pool of the PPOOLEX STB-24 test by using STAR-CCM+ code implemented with two-phase interface model based on the Rayleigh-Taylor instability theory (RTI) which triggers steam depressurization. For the solution of the fine interface, they used Eulerian-Eulerian model for the fluid domain since the volume-of-fluid (VOF) model requires larger mesh points. The RTI resulted in complete steam condensation consistent with the experiment. The fluid tank was open to the atmosphere. They reported the volume fraction distributions in the pool, not the pool temperature or pressure history. For non-condensing gas discharges, however, the VOF is still a good alternative to the Eulerian two-fluid or the DNS approaches. The spatial distribution of each phase is defined in terms of volume fractions and the cell physical properties are obtained from linear combinations of those of constituent phases weighted by each volume fraction. Therefore, conditions where thermal and phase change effects become important are less likely to be simulated realistically. The VOF model is suited for the simulation of flows where each phase constitutes a large structure with a relatively small total contact area between phases. Present work is also interested in this VOF method for application to air discharge into a water pool which occurs in the early operating stages of the said facilities. Our purpose is to validate the VOF method against an existing air discharge experiment of PPOOLEX by using a commercial CFD code, STAR-CCM+ version 10.04, in terms of macroscopic flow properties. Effect of turbulence is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Thermal system engineering experiment

The technical feasibility of a solar thermal collector to provide process steam in an industrial environment was determined. The form of the experiment was an industrial field test.

Source record↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM-PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that comes in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter offgas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel multifunctional energy system (MES) for CO{sub 2} removal with zero energy penalty - article no. 021401

This paper proposes a novel, multifunctional energy system (MES), in which hydrogen and electricity are cogenerated and about 90% of CO{sub 2} is removed. By integrating the methane steam reforming reaction and combustion of coal, the natural gas and coal are utilized synthetically, and coal is burned to provide high-temperature thermal energy to the methane steam reforming reaction. Afterwards, the resulting syngas enters a pressure swing adsorption (PSA) unit to separate about 70% of hydrogen, thereby significantly increasing the concentration of carbon dioxide from nearly 20% to 43% in the PSA tail gas. As a result, the overall efficiency of the new system becomes 63.2%. Compared to a conventional natural gas-based hydrogen plant and a coal-firing steam power plant without CO{sub 2} removal (the overall efficiency of the two systems is 63.0%), the energy penalty for CO{sub 2} removal in the new system is almost totally avoided. Based on the graphical exergy analysis, we propose that the integration of synthetic utilization of fossil fuel (natural gas and coal) and the CO{sub 2} removal process plays a significant role in zero energy penalty for CO{sub 2} removal and its liquefaction in the MES. The result obtained here provides a new approach for CO{sub 2} removal with zero or low thermal efficiency reduction (energy penalty) within an energy system.

20 FOSSIL-FUELED POWER PLANTS↗

An Analysis of Methanol and Hydrogen Production via High-Temperature Electrolysis Using the Sodium Cooled Advanced Fast Reactor

Integration of an advanced, sodium-cooled fast spectrum reactor into nuclear hybrid energy system (NHES) architectures is the focus of the present study. A techno-economic evaluation of several conceptual system designs was performed for the integration of a sodium-cooled Advanced Fast Reactor (AFR) with the electric grid in conjunction with wind-generated electricity. Cases in which excess thermal and electrical energy would be reapportioned within an integrated energy system to a chemical plant are presented. The process applications evaluated include hydrogen production via high temperature steam electrolysis and methanol production via steam methane reforming to produce carbon monoxide and hydrogen which feed a methanol synthesis reactor. Three power cycles were considered for integration with the AFR, including subcritical and supercritical Rankine cycles and a modified supercritical carbon dioxide modified Brayton cycle. The thermal efficiencies of all of the modeled power conversions units were greater than 40%. A thermal efficiency of 42% was adopted in economic studies because two of the cycles either performed at that level or could potentially do so (subcritical Rankine and S-CO2 Brayton). Each of the evaluated hybrid architectures would be technically feasible but would demonstrate a different internal rate of return (IRR) as a function of multiple parameters; all evaluated configurations showed a positive IRR. As expected, integration of an AFR with a chemical plant increases the IRR when “must-take” wind-generated electricity is added to the energy system. Additional dynamic system analyses are recommended to draw detailed conclusions on the feasibility and economic benefits associated with AFR-hybrid energy system operation.

09 BIOMASS FUELS↗

Technoeconomic assessment of hydrogen cogeneration via high temperature steam electrolysis with a light-water reactor

Increased electricity production from renewable energy resources, coupled with low natural gas (NG) prices, has caused existing light-water reactors (LWRs) to experience diminishing returns from the electricity market. This reduction in revenue is forcing LWRs to consider alternative revenue streams, such as introduction hydrogen production or desalination, to remain profitable. This paper performs a technoeconomic assessment (TEA) regarding the viability of retrofitting existing pressurized-water reactors (PWRs) to produce green hydrogen (H 2 ) via high-temperature steam electrolysis (HTSE). Such an integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long term and eliminate CO 2 emissions from the hydrogen production process. Here, to accommodate such an integration, a detailed single market levelized cost of hydrogen (LCOH) and multimarket analyses were conducted of HTSE process operation, requirements, costing, and flexibility. Alongside this costing analysis, market analyses were conducted on the electric and hydrogen markets in the PJM interconnect. Utilizing a novel stochastic, dispatch optimization approach results suggest that a positive gain is achievable, and by operating in multiple markets, the nuclear facility can avoid the sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted is a differential cash flow analysis and, as such, does not present profit levels. LCOH analysis results demonstrate the potential exists to produce hydrogen at a cost as low as $1.20/kg. This price is lower than traditional steam methane reforming (SMR) allowing nuclear based hydrogen production to disrupt the existing hydrogen production market.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A novel means to flexibly operate a hybrid concentrated solar power plant and improve operation during non-ideal direct normal irradiation conditions

Hybridization of concentrated solar power (CSP) with other energy sources can drastically increase how much solar energy is harnessed and potentially expand the current geographical deployment of CSP installlations. In this study, a novel operation strategy referred to as flexible heat integration (FHI), is proposed and applied to a hybrid CSP-natural gas power plant. The proposed plant, modeled in Simulink, employs a solar central receiver (SCR) and dual-source gas boiler to drive a steam Rankine power cycle. FHI involves collecting and dispatching solar energy at modified temperatures during off-design direct normal irradiance (DNI). During low-grade (<100 W/m 2 ) and medium-grade (100–500 W/m 2 ) levels of DNI, molten salt is used for steam boiling and feedwater preheating, respectively, rather than superheating usually seen in SCR steam plants. Hybrid gas-firing supplies energy to bypassed systems. FHI is applied to a hybrid plant over the course of a day from each season for a plant located in Salt Lake City, Utah, an unconventional location due to off-design DNI variability. A spring day exhibiting variable DNI is used as the main case study to demonstrate the dynamics and robust operation under the FHI framework. The operation of the plant over the winter day shows the largest improvement in solar-to-electric (STE) efficiency whereas the summer day exhibits the smallest improvement. Monthly results follow a similar trend with FHI improving STE from 15.3% and 16.3% to 17.0% and 16.7% in January and July, respectively. Yearly results show FHI improving STE efficiency from 16.1% to 17.1% relative to standard hybrid operation. Altogether, the proposed concept expands the current understanding of energy management in hybrid SCR-natural power plants under non-ideal DNI conditions and locations that have lower DNI by applying FHI.

14 SOLAR ENERGY↗

Towards a Consolidated Approach for the Assessment of Evaluation Models of Nuclear Power Reactors

The STARS project at the Paul Scherrer Institut (PSI) has adopted the TRACE thermal-hydraulic (T-H) code for best-estimate system transient simulations of the Swiss Light Water Reactors (LWRs). For analyses involving interactions between system and core, a coupling of TRACE with the SIMULATE-3K (S3K) LWR core simulator has also been developed. In this configuration, the TRACE code and associated nuclear power reactor simulation models play a central role to achieve a comprehensive safety analysis capability. Thus, efforts have now been undertaken to consolidate the validation strategy by implementing a more rigorous and structured assessment approach for TRACE applications involving either only system T-H evaluations or requiring interfaces to e.g. detailed core or fuel behavior models. The first part of this paper presents the preliminary concepts of this validation strategy. The principle is to systematically track the evolution of a given set of predicted physical Quantities of Interest (QoIs) over a multidimensional parametric space where each of the dimensions represent the evolution of specific analysis aspects, including e.g. code version, transient specific simulation methodology and model "nodalisation". If properly set up, such environment should provide code developers and code users with persistent (less affected by user effect) and quantified information (sensitivity of QoIs) on the applicability of a simulation scheme (codes, input models, methodology) for steady state and transient analysis of full LWR systems. Through this, for each given transient/accident, critical paths of the validation process can be identified that could then translate into defining reference schemes to be applied for downstream predictive simulations. In order to illustrate this approach, the second part of this paper presents a first application of this validation strategy to an inadvertent blowdown event that occurred in a Swiss BWR/6. The transient was initiated by the spurious actuation of the Automatic Depressurization System (ADS). The validation approach progresses through a number of dimensions here: First, the same BWR system simulation model is assessed for different versions of the TRACE code, up to the most recent one. The second dimension is the "nodalisation" dimension, where changes to the input model are assessed. The third dimension is the "methodology" dimension. In this case imposed power and an updated TRACE core model are investigated. For each step in each validation dimension, a common set of QoIs are investigated. For the steady-state results, these include fuel temperatures distributions. For the transient part of the present study, the evaluated QoIs include the system pressure evolution and water carry-over into the steam line.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CIRCULATING MOVING BED COMBUSTION PROOF OF CONCEPT

Circulating Moving Bed (CMB) combustion technology has its roots in traditional circulating fluidized bed technology and involves a novel method of solid fuel combustion and heat transfer. CMB technology represents a step change in improved performance and cost relative to conventional PC and FBC boilers. The CMB heat exchanger preheats the energy cycle working fluid, steam or air, to the high temperature levels required in systems for advanced power generation. Unique features of the CMB are the reduction of the heat transfer surfaces by about 60% as a result of the enhanced heat transfer rates, flexibility of operation, and about 30% lower cost over existing technology. The CMB Phase I project ran from July 2001 through March 2003. Its objective was to continue development of the CMB technology with a series of proof of concept tests. The tests were conducted at a scale that provided design data for scale up to a demonstration plant. These objectives were met by conducting a series of experiments in ALSTOM Power’s Multi-use Test Facility (MTF). The MTF was modified to operate under CMB conditions of commercial interest. The objective of the tests were to evaluate gas-to-solids heat transfer in the upper furnace, assess agglomeration in the high temperature CMB bubbling bed, and evaluate solids-to-tube heat transfer in the moving bed heat exchanger. The Phase I program results showed that there are still some significant technical uncertainties that needed to be resolved before the technology can be confidently scaled up for a successful demonstration plant design. Work remained in three primary areas: • scale up of gas to solid heat transfer • high temperature finned surface design • the overall requirements of mechanical and process design. The CMB Phase II workscope built upon the results of Phase I and specifically addressed the remaining technical uncertainties. It included a scaled MTF heat transfer test to provide the necessary data to scale up gas-to-solids heat transfer. A stress test rig was built and tested to provide validation data for a stress model needed to support high temperature finned surface design. Additional cold flow model tests and MTF tests were conducted to address mechanical and process design issues. This information was then used to design and cost a commercial CMB design concept. Finally, the MBHE was reconfigured into a slice arrangement and tested for an extended duration at a commercial CFB plant.

42 ENGINEERING↗

Stable Catalysts for Combined Dry and Steam Reforming of Methane and Carbon Dioxide

The specific aim of this project is to develop a comprehensive understanding of cheaper and more stable methane and carbon dioxide reforming catalysts with an optimal introduction of steam to reduce carbon deposits that typically prevent the catalytic systems from transferring to commercial implementation. The work was proposed as a two-year project with the end goal of to show a reliable catalyst system run for at least 400 hours at temperatures less than 800 °C with less than 5% loss of activity of the catalyst and a carbon monoxide to hydrogen product ratio of at least 1:1. The project went for one-year and met the end of year milestone by developing two strategies (use of a cerium co-catalyst and introducing 5% water) that reduced the carbon deposition rates by at least 20% relative to the baseline 10% NiMgAlO methane reforming of CO 2 at < 800 °C in order to shown technical feasibility of the concept.

36 MATERIALS SCIENCE↗

Development of dry coal feeders

Design and fabrication of equipment of feed coal into pressurized environments were investigated. Concepts were selected based on feeder system performance and economic projections. These systems include: two approaches using rotating components, a gas or steam driven ejector, and a modified standpipe feeder concept. Results of development testing of critical components, design procedures, and performance prediction techniques are reviewed.

Bonin, J. H.↗

Heat pipes and their use in technology

Heat pipes may be employed as temperature regulators, heat diodes, transformers, storage batteries, or utilized for transforming thermal energy into mechanical, electric, or other forms of energy. General concepts were established for the analysis of the transfer process in heat pipes. A system of equations was developed to describe the thermodynamics of steam passage through a cross section of a heat pipe.

Vasilyev, L.↗