Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SILICONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast and efficient Sb-based type-II phototransistors integrated on silicon

Increasing the energy efficiency and reducing the footprint of on-chip photodetectors enable dense optical interconnects for emerging computational and sensing applications. While heterojunction phototransistors (HPTs) exhibit high energy efficiency and negligible excess noise factor, their gain-bandwidth product (GBP) has been inferior to that of avalanche photodiodes at low optical powers. Here, we demonstrate that utilizing type-II energy band alignment in an Sb-based HPT results in six times smaller junction capacitance per unit area and a significantly higher GBP at low optical powers. These type-II HPTs were scaled down to 2 μm in diameter and fully integrated with photonic waveguides on silicon. Thanks to their extremely low dark current and high internal gain, these devices exhibit a GBP similar to the best avalanche devices (∼270 GHz) but with one order of magnitude better energy efficiency. Their energy consumption is about 5 fJ/bit at 3.2 Gbps, with an error rate below 10−9 at −25 dBm optical power at 1550 nm. These features suggest new opportunities for creating highly efficient and compact optical receivers based on phototransistors with type-II band alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Triangular cross-section grating couplers for integrated quantum nanophotonic hardware in silicon carbide

We design, fabricate, and characterize fishbone grating couplers for triangular cross-section photonics in silicon carbide compatible with color center integration. The periodic and aperiodic grating coupler designs are optimized to outcouple up to 31% of light in the fundamental TE mode of a triangular waveguide. The devices are fabricated using an ion beam etching process in a 4H–SiC sample implanted with NV center ensembles. The room-temperature transmission and the cryogenic NV center photoluminescence collection measurements indicate experimental grating coupler efficiency of up to 24%. This result provides a scalable method to efficiently extract color center light from SiC quantum nanophotonic devices to free-space optics.

Saha, Pranta↗

Identification of dislocation-related and point-defects in III-As layers for silicon photonics applications

Abstract The aim of this paper is to identify, analyze and compare the defects present in III-As, as a function of dislocation density, and as a function of the presence/absence of quantum dots (QDs). Such materials are of fundamental importance for the development of lasers and photodiodes for silicon photonics. The study is based on an extensive deep-level transient spectroscopy investigation, carried out on GaAs pin diodes grown on Si and on GaAs (that differ in the dislocation density), with and without embedded QDs. The original results described in this paper demonstrate that: (a) we were able to identify four different defects within the device grown on Si (three electron and one hole traps) and one defect (hole trap) in the device on GaAs, common to both samples; (b) all the majority carrier traps identified are located near midgap, i.e. are efficient non-radiative recombination centers; (c) such defects are absent (or non-detectable) in the sample grown on GaAs substrate, having a very low dislocation density; (d) the presence of QDs does not result in additional defects within the semiconductor material; (e) the analysis of the capture kinetics revealed that two of the identified traps are related to point defects, whereas the other two traps can be associated with point defects located near a dislocation; (f) a comparison with previous reports indicate that the detected traps are related to native III-As defects, or to oxygen-related complexes.

Physics↗

Etched Silicon Planar CRL Optics for the High-Energy X-ray Diffraction Beamlines 11-ID-B and 11-ID-C at the APS

We report the focusing of high-energy X-rays is most commonly achieved by commercially available compound refractive lenses (CRL), which are added together in larger structures. There is a need for high-energy X-ray beamlines to enable focusing in only one dimension down to a few micrometers to study layered materials and thin films. High-energy X-rays above 50 keV require often 100 lenses or more, therefore it is more efficient to etch the complete arrays of lenses into a monolithic substrate like a silicon wafer. Custom lens arrays were fabricated for the high-energy x-ray beamlines 11-ID-B, and 11-ID-C at the Argonne National Laboratory. The fabrication required tuning parameters of the Bosch process to optimize the etching of deep vertical sidewalls at a reasonable speed without overheating. The beamline 11-ID-B is equipped with lens arrays of 85-110 lenses for 59 keV and 190-250 lenses for 87 keV photon energy, focusing the beam vertically below 5.0 µm at the sample positions between 1600 mm to 2100 mm. 11-ID-C has received arrays of 435 lenses that focus 106 keV X-rays to a vertical height of 2.0 µm at the sample position. In both cases, the flux density gain in the focal spot is larger than a factor of 20, relative to using slits to cut the beam size. The lens setup is permanently installed and can be moved in and out of the beam during the experiment without further alignment. The lenses have enabled operando diffraction studies on interfaces in batteries and the development of pair distribution function (PDF) analysis using grazing incidence geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Effects Model for Ultra-Thin Silicon Solar Cells

This work is focused on investigation of radiation effects in Ultra-Thin Silicon solar cells with a particular emphasis on electron irradiation. The study is motivated by the application of these solar cells, developed by Solestial, Inc., for powering space missions, including those led by NASA, the Department Of Defence (DOD), and commercial satellite missions. Our research encompasses both experimental and theoretical approaches, addressing unique challenges posed by ultra-thin solar cell technology that deviates from the traditional models. From the experimental point of view, the test structures were irradiated with 1 MeV electrons up to the fluence of 1E+15 e/cm$^{2}$. Radiation effects due to accumulated electron dose were noticed as a drop in open-circuit voltage (Voc). An analytical expression for modeling the Voc characteristic of the UT-Si cell after exposure to electron irradiation was formulated and subsequently compared with experimental data. The theoretical foundation of the proposed approach builds upon the Non-Ionising Energy Loss (NIEL) concept, a fundamental parameter in addressing radiation damage modelling and survivability predictions.

Fedoseyev, Alex↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for precise hit position reconstruction in Resistive Silicon Detectors

RSDs are LGAD silicon sensors with 100% fill factor, based on the principle of AC-coupled resistive read-out. Signal sharing and internal charge multiplication are the RSD key features to achieve picosecond-level time resolution and micron-level spatial resolution, thus making these sensors promising candidates as 4D-trackers for future experiments. This paper describes the use of a neural network to reconstruct the hit position of ionizing particles, an approach that can boost the performance of the RSD with respect to analytical models. The neural network has been trained in the laboratory and then validated on test beam data. The device-under-test in this work is a 450 μm-pitch matrix from the FBK RSD2 production, which achieved a resolution of about 65 μm at the DESY Test Beam Facility, a 50% improvement compared to a simple analytical reconstruction method, and a factor two better than the resolution of a standard pixel sensor of equal pitch size with binary read-out. The test beam result is compatible with the laboratory ones obtained during the neural network training, confirming the ability of the machine learning model to provide accurate predictions even in environments very different from the training one. Prospects for future improvements are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗