Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generative adversarial networks for scintillation signal simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network — a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. Furthermore, the network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

47 OTHER INSTRUMENTATION↗

A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

Here we report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm)level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source.The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10 $-$4 cm $-$1 ppm $-$1 , correspondingto an absorption cross section of (4.99±0.51) × 10 $-$21 cm 2 molecule $-$1 .We obtain the relationship between absorption length and nitrogenconcentration over the 0 to 50 ppm range and discuss the implicationsfor the design and data analysis of future large liquid argon time projection chamber (LArTPC)detectors. Our results indicate that for a current-generation LArTPC, wherea concentration of 2 parts per million of nitrogen is expected, the attenuationlength due to nitrogen will be 30±3 meters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic Scintillator for Real-Time Neutron Dosimetry

We have developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with 137 Cs and 252 Cf, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV–0 MeV range using MCNPX-PoliMi. The measured unfolded 252 Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the light yield response of the Gd-compatible water-based liquid scintillator with the Brookhaven one-ton testbed

The water-based liquid scintillator (WbLS) enables hybrid detection by combining scintillation and Cherenkov signals, providing superior event reconstruction capabilities compared to conventional neutrino detectors. For this work, we measured the light yield of Gd-compatible WbLS at varying concentrations from 0.35% to 1% by mass, using cosmic-ray muons in a 1-ton scale detector at Brookhaven National Laboratory. The light yield is measured as (69.2 ± 6.9) ph/MeV at 0.35% concentration, which increased to (87.3 ± 8.7) ph/MeV at 1%. These results establish a quantitative basis for optimizing future WbLS-based detectors in neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discrete Electronic Bands in Semiconductors and Insulators: Potential High-Light-Yield Scintillators

Bulk semiconductors and insulators typically have continuous valence and conduction bands. In this paper, we show that valence and conduction bands of a multinary semiconductor or insulator can be split to narrow discrete bands separated by large energy gaps. This unique electronic structure is demonstrated by first-principles calculations in several quaternary elpasolite compounds, i.e., Cs 2 NaInBr 6 , Cs 2 NaBiCl 6 , and Tl 2 NaBiCl 6 . The narrow discrete band structure in these quaternary elpasolites is due to the large electronegativity difference among cations and the large nearest-neighbor distances in cation sublattices. We further use Cs 2 NaInBr 6 as an example to show that the narrow bands can stabilize self-trapped and dopant-bound excitons (in which both the electron and the hole are strongly localized in static positions on adjacent sites) and promote strong exciton emission at room temperature. The discrete band structure should further suppress thermalization of hot carriers and may lead to enhanced impact ionization, which is usually considered inefficient in bulk semiconductors and insulators. Finally, these characteristics can enable efficient room-temperature light emission in low-gap scintillators and may overcome the light-yield bottleneck in current scintillator research.

36 MATERIALS SCIENCE↗

Band-gap and band-edge engineering of multicomponent garnet scintillators from first principles

Complex doping schemes in R 3 Al 5 O 12 (where R is the rare-earth element) garnet compounds have recently led to pronounced improvements in scintillator performance. Specifically, by admixing lutetium and yttrium aluminate garnets with gallium and gadolinium, the band gap is altered in a manner that facilitates the removal of deleterious electron trapping associated with cation antisite defects. Here, we expand upon this initial work to systematically investigate the effect of substitutional admixing on the energy levels of band edges. Density-functional theory and hybrid density-functional theory (HDFT) are used to survey potential admixing candidates that modify either the conduction-band minimum (CBM) or valence-band maximum (VBM). We consider two sets of compositions based on Lu 3 B 5 O 12 where B is Al, Ga, In, As, and Sb, and R 3 Al 5 O 12 , where R is Lu, Gd, Dy, and Er. We find that admixing with various R cations does not appreciably affect the band gap or band edges. In contrast, substituting Al with cations of dissimilar ionic radii has a profound impact on the band structure. We further show that certain dopants can be used to selectively modify only the CBM or the VBM. Specifically, Ga and In decrease the band gap by lowering the CBM, while As and Sb decrease the band gap by raising the VBM, the relative change in band gap is quantitatively validated by HDFT. These results demonstrate a powerful approach to quickly screen the impact of dopants on the electronic structure of scintillator compounds, identifying those dopants which alter the band edges in very specific ways to eliminate both electron and hole traps responsible for performance limitations. Furthermore, this approach should be broadly applicable for the optimization of electronic and optical performance for a wide range of compounds by tuning the VBM and CBM.

36 MATERIALS SCIENCE↗

Search for α decay of Te 104 with a novel recoil-decay scintillation detector

A search for superallowed α decay of N = Z nuclei Te 104 and Xe 108 was carried out using a novel recoil-decay scintillator detector at the tandem accelerator facility at the Japan Atomic Energy Agency (JAEA). In this study, inorganic crystal scintillation material YAP:Ce (yttrium aluminum perovskite) coupled to a position-sensitive photomultiplier tube (PSPMT) was implemented for the first time in a radioactive decay experiment. Residues from the fusion-evaporation reaction Ni 58 + Fe 54 → Xe * 112 were separated by the JAEA Recoil Mass Separator (RMS) and implanted into the YAP:Ce crystal. α decays of neutron-deficient tellurium isotopes were identified and proton emission of I 109 was observed. The α -decay chain Xe 109 → Te 105 → Sn 101 was recorded with a time interval of 960 ns between two α pulses. Position localization in the crystal for decays and ions in the energy range from hundreds of keV to 60 MeV was achieved with an accuracy of 0.67 mm, proving that this detector is capable of making temporal and spatial correlations for fast decay events. No conclusive evidence was found for the decay chain Xe 108 → Te 104 → Sn 100 within 3 days of experiment. However, two events were observed with properties consistent with the reported observation at the Fragment Mass Analyzer (FMA), but with a separation between signals of less than 4 ns. The cross section limit of 130 pb was obtained for production of two events of Xe 108 , about an order of magnitude below the expectation based on earlier cross section measurements and the HIVAP fusion-evaporation code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extending light WIMP searches to single scintillation photons in LUX

© 2020 American Physical Society. We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a twofold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c2 WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of the yield of 8 He isotopes produced in liquid scintillator by cosmic-ray muons at Daya Bay

Here, Daya Bay presents the first measurement of cosmogenic 8 He isotope production in liquid scintillator, using an innovative method for identifying cascade decays of 8 He and its child isotope, 8 Li. We also measure the production yield of 9 Li isotopes using well-established methodology. The results, in units of 10 –8 μ –1 ⁢g –1 cm 2 , are 0.307 ± 0.042, 0.341 ± 0.040, and 0.546 ± 0.076 for 8 He, and 6.73 ± 0.73, 6.75 ± 0.70, and 13.74 ± 0.82 for 9 Li at average muon energies of 63.9 GeV, 64.7 GeV, and 143.0 GeV, respectively. The measured production rate of 8 He isotopes is more than an order of magnitude lower than any other measurement of cosmogenic isotope production. It replaces the results of previous attempts to determine the ratio of 8 He to 9 Li production that yielded a wide range of limits from 0% to 30%. The results provide future liquid-scintillator-based experiments with improved ability to predict cosmogenic backgrounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface background suppression in liquid argon dark matter detectors using a newly discovered time component of tetraphenyl-butadiene scintillation

Here, decays of radioisotopes on inner detector surfaces can pose a major background concern for the direct detection of dark matter. While these backgrounds are conventionally mitigated with position cuts, these cuts reduce the exposure of the detector by decreasing the sensitive mass, and uncertainty in position determination may make it impossible to adequately remove such events in certain detectors. In this paper, we provide a new technique for substantially reducing these surface backgrounds in liquid argon (LAr) detectors, independent of position cuts. These detectors typically use a coating of tetraphenyl-butadiene (TPB) on the inner surfaces as a wavelength shifter to convert vacuum ultraviolet (VUV) LAr scintillation light to the visible spectrum. We find that TPB scintillation contains a component with a previously unreported exceptionally long lifetime (~ms). We discovered that this component differs significantly in magnitude between alpha, beta, and VUV excitation, which enables the use of pulse shape discrimination to suppress surface backgrounds by more than a factor of 10 3 with negligible loss of dark matter sensitivity. We also discuss how this technique can be extended beyond just LAr experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal Growth and Scintillation Properties of ${\rm Cs}_{2}{\rm NaGdBr}_{6}{:}{\rm Ce}^{3+}$

Single crystals of Cs 2 NaGdBr 6 with different Ce +3 activator concentrations were grown by a two-zone Bridgman method. This new compound belongs to a large elpasolite halide (A 2 BLnX 6 ) family. Many of these elpasolite compounds have shown high luminosity, good energy resolution and excellent proportionality in comparison to traditional scintillators such as CsI and NaI; therefore, they are particularly attractive for gamma-ray spectroscopy applications. This study investigated the scintillator properties of Cs 2 NaGdBr 6 :Ce +3 crystals as a new material for radiation detection. Special focus has been placed on the effects of activator concentration (0 to 50 mol.%) on the photoluminescence responses. Results of structural refinement, photoluminescence, radioluminescence, lifetime and proportionality measurements for this new compound are reported.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating the anisotropic scintillation response in anthracene through neutron, gamma-ray, and muon measurements

Our paper reports a series of measurements that characterize the directional dependence of the scintillation response of crystalline anthracene to incident DT neutrons, DD neutrons, 137 Cs gamma rays, and, for the first time, cosmic ray muons. Moreover, the neutron measurements give the amplitude and pulse shape dependence on the proton recoil direction over one hemisphere of the crystal, confirming and extending previous results in the literature. In similar measurements using incident gamma rays, no directional effect is evident, and any anisotropy with respect to the electron recoil direction is constrained to have a magnitude of less than a tenth of that present in the proton recoil events. Cosmic muons are measured at two directions, and no anisotropy is observed. Our set of observations indicates that high dE/dx is necessary for an anisotropy to be present for a given type of scintillation event, which in turn could be used to discriminate among different hypotheses for the underlying causes of the anisotropy, which are not well understood.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of σ/Q ββ =1 %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler, Trento, Italy, in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. Here, we report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Scintillator high-gain avalanche rushing photoconductor active-matrix flat panel imager: Zero-spatial frequency x-ray imaging properties of the solid-state SHARP sensor structure

Purpose: The authors are investigating the feasibility of a new type of solid-state x-ray imaging sensor with programmable avalanche gain: scintillator high-gain avalanche rushing photoconductor active matrix flat panel imager (SHARP-AMFPI). The purpose of the present work is to investigate the inherent x-ray detection properties of SHARP and demonstrate its wide dynamic range through programmable gain. Methods: A distributed resistive layer (DRL) was developed to maintain stable avalanche gain operation in a solid-state HARP. The signal and noise properties of the HARP-DRL for optical photon detection were investigated as a function of avalanche gain both theoretically and experimentally, and the results were compared with HARP tube (with electron beam readout) used in previous investigations of zero spatial frequency performance of SHARP. For this new investigation, a solid-state SHARP x-ray image sensor was formed by direct optical coupling of the HARP-DRL with a structured cesium iodide (CsI) scintillator. The x-ray sensitivity of this sensor was measured as a function of avalanche gain and the results were compared with the sensitivity of HARP-DRL measured optically. The dynamic range of HARP-DRL with variable avalanche gain was investigated for the entire exposure range encountered in radiography/fluoroscopy (R/F) applications. Results: The signal from HARP-DRL as a function of electric field showed stable avalanche gain, and the noise associated with the avalanche process agrees well with theory and previous measurements from a HARP tube. This result indicates that when coupled with CsI for x-ray detection, the additional noise associated with avalanche gain in HARP-DRL is negligible. The x-ray sensitivity measurements using the SHARP sensor produced identical avalanche gain dependence on electric field as the optical measurements with HARP-DRL. Adjusting the avalanche multiplication gain in HARP-DRL enabled a very wide dynamic range which encompassed all clinically relevant medical x-ray exposures. Conclusions: This work demonstrates that the HARP-DRL sensor enables the practical implementation of a SHARP solid-state x-ray sensor capable of quantum noise limited operation throughout the entire range of clinically relevant x-ray exposures. This is an important step toward the realization of a SHARP-AMFPI x-ray flat-panel imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Exradin W1 scintillator for use in radiotherapy

Purpose: To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. Methods: We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. Results: Exradin W1 showed a temperature dependence of −0.225% °C{sup −1}. The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. Conclusions: The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗