Efficient data acquisition and training of collisional-radiative model artificial neural network surrogates through adaptive parameter space sampling

Abstract Effective plasma transport modeling of magnetically confined fusion devices relies on having an accurate understanding of the ion composition and radiative power losses of the plasma. Generally, these quantities can be obtained from solutions of a collisional-radiative (CR) model at each time step within a plasma transport simulation. However, even compact, approximate CR models can be computationally onerous to evaluate, and in-situ evaluation of these models within a larger plasma transport code can lead to a rigid bottleneck. As a way to bypass this bottleneck, we propose deploying artificial neural network (ANN) surrogates to allow rapid evaluation of the necessary plasma quantities. However, one issue with training an accurate ANN surrogate is the reliance on a sufficiently large and representative training and validation data set, which can be time-consuming to generate. In this work we explore a data-driven active learning and training routine to allow autonomous adaptive sampling of the problem parameter space to ensure a sufficiently large and meaningful set of training data is assembled for the network training. As a result, we can demonstrate approximately order-of-magnitude savings in required training data samples to produce an accurate surrogate.

97 MATHEMATICS AND COMPUTING↗

Levitation Technology in International Space Station Research

The International Space Station (ISS) is a unique multidisciplinary orbiting laboratory for science and technology research, enabling discoveries that benefit life on Earth and exploration of the universe. ISS facilities for containerless sample processing in Materials Science experiments include levitation devices with specimen positioning control while reducing containment vessel contamination. For example, ESA's EML (ElectroMagnetic Levitator), is used for melting and solidification of conductive metals, alloys, or semiconductors in ultra-high vacuum, or in high-purity gaseous atmospheres. Sample heating and positioning are accomplished through electromagnetic fields generated by a coil system. EML applications cover investigation of solidification and microstructural formation, evaluation of thermophysical properties of highly reactive metals (whose properties can be very sensitive to contamination), and examination of undercooled liquid metals to understand metastable phase convection and influence convection on structural changes. MSL utilization includes development of novel light-weight, high-performance materials. Another facility, JAXA's ELF (Electrostatic Levitation Furnace), is used to perform high temperature melting while avoiding chemical reactions with crucibles by levitating a sample through Coulomb force. ELF is capable of measuring density, surface tension, and viscosity of samples at high temperatures. One of the initial ELF investigations, Interfacial Energy-1, is aimed at clarification of interfacial phenomena between molten steels and oxide melts with industrial applications in control processes for liquid mixing. In addition to these Materials Science facilities, other ISS investigations that involve levitation employ it for biological research. For example, NASA's "Magnetic 3D Culturing and Bioprinting" investigation uses magnetic levitation for three-dimensional culturing and positioning of magnetized cells to generate spheroid assemblies for biomedical applications. Levitation is also used as a modeled microgravity ground analog in the NASA OsteoOmics ISS investigation, which tests whether magnetic levitation accurately simulates microgravity conditions by studying gravitational regulation of osteoblast and osteoclast genomics and metabolism. Elucidating the cellular mechanisms of bone loss in microgravity contributes to the understanding of bone loss in medical disorders on Earth, which may lead to development of preventive or therapeutic countermeasures. Thus, the ISS state-of-the-art laboratory offers various levitation capability platforms with applications for innovative research in Materials and Life Sciences disciplines, with benefits for humanity.

Guinart-Ramirez, Y.↗

Theory and applications of sampled analog recursive CTD comb filters

Sampled analog comb filter using a recursive filter implementation was studied. Charge transfer device delay lines were used as the delay elements. The similarities and differences between sampled analog recursive filter and digital recursive filter were pointed out. Both canceller type and integrator type comb filter using the first order or the second order canonical circuits were studied. Experimental results of frequency response are presented to show their difference from that of digital filters. A theoretical analysis was presented based essentially on the digital filter theory but modified to take into account the differences described above. The usefulness of this theory in analyzing the comb filter characteristics was discussed. Several applications of both the canceller type comb filter and the integrator type comb filter were demonstrated.

Tao, T. F.↗

Electro-optic network analyzer

The bandwidth of frequency domain measurement methods of electrical signals has usually been far greater than the bandwidth of time domain methods. The primary limits of the time domain approach have been the 20 to 30 GHz bandwidth limit for electronic waveform acquisition instrumentation, and the lack of usable electrical pulse generators for excitation of a test device. The bandwidth of frequency domain network analysis appears to have reached a plateau of between 100 to 200 GHz, while time domain measurement have improved markedly in both bandwidth and sensitivity with the introduction of the pulsed laser based electro-optic sampling approach. Network analysis or the measurement of device scattering parameters provides information necessary to the design of electronic network such as high frequency amplifiers, mixers, and phase shifter. The bandwidth of frequency domain network analysis is currently being exceeded by the next generations of high frequency transistors and devices. Thus the electro-optic approach is a natural means of extending network analysis into the range above 100 GHz by employing time domain methods. In this approach, a suitable electrical excitation pulse is generated and propagated along a transmission line toward a test device. In the picosecond domain, laser driven photoconductive switches provide a unique method of generating electrical transients. Several materials were studied for generating short electrical pulses using photoconductive switches. The various semiconductive materials tested for photoconductive switching, and the electro-optic measurement technique used to characterize the material performance are described.

Jackson, Todd A.↗

High-resolution and site-specific scanning spreading resistance microscopy and its applications to silicon devices

Due to the continuous reduction of the critical dimensions of semiconductor devices, it becomes very important to know the two dimensional (2D) doping profile for improving device performance. Scanning spreading resistance microscopy (SSRM) performed in high vacuum is a powerful technique for quantitative 2D-doping profiling, with high spatial resolution and wide dynamic range of carrier concentration, as well as capability of site-specific analysis for accurate position. In this paper, we review SSRM applications to source/drain engineering in Si devices and their correlation with device characteristics by demonstrating several case studies. Direct observation of (110)/(100) CMOSFETs clarified significant differences between both pFETs and nFETs on (110) and (100) silicon substrates, revealing 2D channeling effect of boron ion implantation in pFETs; as well as silicidation impact on junction leakage-current characteristics in nFETs. Furthermore, our sample-preparation breakthrough enables site-specific SSRM characterization within 60 nm ultra thin samples and therefore failure analysis of real SRAM devices, demonstrating the high potential of SSRM technology for further device scaling and for failure analysis.

36 MATERIALS SCIENCE↗

Analysis of Organic Electron Materials using Neutron Scattering (Final Report)

Neutron scattering is a powerful suite of measurement techniques that enable unique analysis of structure and dynamics of a wide variety of materials. Specifically, neutrons interact strongly with protons, which enables excellent contrast in light element organic materials that cannot be obtained with any other measurements. This series of three proposals focused on using inelastic neutron scattering (INS) to study the vibrations (dynamics) of the organic molecules involved in organic electronic devices. Our main goals were to demonstrate that INS is capable of elucidating new, useful, and unique knowledge about organic electronic samples that could be used to improve the function of devices or to solve outstanding problems that could not be solved using other measurement techniques. Since all of the goal involved using INS or other neutron techniques to do something “new” a large part of the effort was focused on complex data interpretation and development of modeling workflows that could be used by other members of the organic electronics community to study their materials. To facilitate the goal of making INS measurements more accessible to a broader community and for a wider range of materials, we optimized and engineered the computational workflows to be well documented, publicly available, and user friendly. The individual titles of the three sequential DOE-BES awards are: (1) Engineering doping profiles in organic semiconducting materials, (2) Measurement and modeling of molecular dopant structure and dynamics, and (3) Quantification of Dynamic Disorder in Electronic and Excitonic Organic Materials. For readability, this report is organized to highlight the progress of the research thematically. Many of the ideas started in one grant period and then spilled over into later awards and collaborative research.

36 MATERIALS SCIENCE↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

Semiconductor neutron detectors using depleted uranium oxide

This paper reports on recent attempts to develop and test a new type of solid-state neutron detector fabricated from uranium compounds. It has been known for many years that uranium oxide (UO2), triuranium octoxide (U3O8) and other uranium compounds exhibit semiconducting characteristics with a broad range of electrical properties. We seek to exploit these characteristics to make a direct-conversion semiconductor neutron detector. In such a device a neutron interacts with a uranium nucleus, inducing ssion. The ssion products deposit energy-producing, detectable electron-hole pairs. The high energy released in the ssion reaction indicates that noise discrimination in such a device has the potential to be excellent. Schottky devices were fabricated using a chemical deposition coating technique to deposit UO2 layers a few microns thick on a sapphire substrate. Schottky devices have also been made using a single crystal from UO2 samples approximately 500 microns thick. Neutron sensitivity simulations have been performed using GEANT4. Neutron sensitivity for the Schottky devices was tested experimentally using a 252Cf source.

neutron detection, uranium oxide, semiconductor↗

Formation of Ultra-Shallow Junctions by Advanced Plasma Doping Techniques

The fabrication of advanced CMOS devices calls for production worthy doping solutions to address requirements for increasingly shallow and abrupt junctions, while maintaining high dopant activation to meet series resistance requirements. Plasma Doping (PLAD), which has already been adopted in high volume manufacturing in the ultra high dose, low energy regime for advanced DRAM technology nodes, is now being investigated for source drain extension (SDE) implants, where precise and repeatable dopant placement is critical for maintaining control over device parameters. In this article, we investigate the process performance of SDE implants carried out in a VIISta registered PLAD system using p- type dopant precursors. Key metrics, such as junction depth, profile abruptness and sheet resistance are reported for as-implanted junctions, as well as samples processed with low thermal budget anneal techniques. Device performance data demonstrating the feasibility of the approach are presented. The advanced control features in the PLAD system are critical in enabling the process performance required for SDE implants.

36 MATERIALS SCIENCE↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Bioelectrochemical crossbar architecture screening platform for extracellular electron transfer

Electroactive microbes can serve as living components in bioelectronic devices, where their unique ability to transfer electrons enables applications in sensing, energy conversion, and synthesis, but they remain challenging to engineer because the bioelectrochemical systems (BESs) used for characterization are low throughput. Here, we present a bioelectrochemical crossbar architecture screening platform (BiCASP) that uses stacked and orthogonally arrayed electrodes to enable individual sample selection for characterization in arrayed formats. This device reports on the current generated by electroactive bacteria on the minute timescale, decreasing the time for data acquisition by several orders of magnitude compared to conventional BESs. This device increases the throughput of screening engineered biological components in cells, identifying mutants of the membrane protein wire MtrA in Shewanella oneidensis that retain the ability to support extracellular electron transfer (EET). BiCASP may be integrated with bioelectronics that need directed evolution of electroactive proteins.

Shewanella↗

Effect of particle characteristics on the evolution of particle size, particle morphology, and fabric of sands loaded under uniaxial compression

This work presents the results and analyses of uniaxial compression experiments performed on three silica sands. The sands have comparable particle-size distributions, but their particles differ in morphology and strength. Cylindrical samples of the three sands were compressed in a loading device placed inside an X-ray microscope (XRM) and scanned at multiple stress levels during uniaxial compression. 3D tomography data of the samples obtained from the XRM at different stress levels were then analyzed to obtain the distributions of particle size, particle morphology, and interparticle contact normals within the sample. Results indicate that: (1) the compressibility of the sands loaded under uniaxial compression is closely tied to particle morphology and strength and (2) the anisotropy in the orientations of interparticle contact normals generally increases with axial stress; however, this increase is limited by the occurrence of particle crushing in the sample.

3D X-ray computed tomography↗

Pre-conceptual design activities for the materials plasma exposure experiment

The development of next step fusion facilities such as DEMO or a Fusion Nuclear Science Facility (FNSF) requires first closing technology gaps in a few critical areas. Understanding the material-plasma interface is necessary to enable the development of divertors for long-pulse plasma facilities. A pre-conceptual design for a proposed steady-state linear plasma device, the Materials Plasma Exposure Experiment (MPEX), is underway. A helicon plasma source along with ion cyclotron and electron Bernstein wave heating systems will produce ITER divertor relevant plasma conditions with steady-state parallel heat fluxes of up to 40 MW/m 2 with ion fluxes up to 10 24 /m 2 s on target. Current plans are for the device to use superconducting magnets to produce 1–2 T fields. As a steady-state device, active cooling will be required for components that interact with the plasma (targets, limiters, etc.), as well as for other plasma facing components (transport regions, vacuum tanks, diagnostic ports). Design concepts for the vacuum system, the cooling system, and the plasma heating systems have been completed. The device will include the capability for handling samples that have been neutron irradiated in order to consider the multivariate effects of neutrons, plasma, and high heat-flux on the microstructure of divertor candidate materials. A vacuum cask, which can be disconnected from the high field environment in order to perform in-vacuo diagnosis of the surface evolution is also planned for the facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic and Morphological Inhomogeneities in Pristine and Deteriorated Perovskite Photovoltaic Films

We perform scanning microwave microscopy (SMM) to study the spatially varying electronic properties and related morphology of pristine and degraded methylammonium lead-halide (MAPI) perovskite films fabricated under different ambient humidity. Here, we find that higher processing humidity leads to the emergence of increased conductivity at the grain boundaries but also correlates with the appearance of resistive grains that contain PbI 2 . Deteriorated films show larger and increasingly insulating grain boundaries as well as spatially localized regions of reduced conductivity within grains. These results suggest that while humidity during film fabrication primarily benefits device properties due to the passivation of traps at the grain boundaries and self-doping, it also results in the emergence of PbI 2 -containing grains. We further establish that MAPI film deterioration under ambient conditions proceeds via the spatially localized breakdown of film conductivity, both at grain boundaries and within grains, due to local variations in susceptibility to deterioration. These results confirm that PbI 2 has both beneficial and adverse effects on device performance and provide new means for device optimization by revealing spatial variations in sample conductivity as well as morphological differences in resistance to sample deterioration.

14 SOLAR ENERGY↗

Terahertz quantum well photodetectors with reflection-grating couplers

The design, fabrication, and characterization of terahertz (THz) quantum well photodetectors with one-dimensional reflection-grating coupler are presented. It is found that the reflection gratings could effectively couple the THz waves normally incident to the device. Compared with the 45-degree facet sample, the peak responsivity of this grating-coupled detector is enhanced by over 20%. The effects of the gratings on the photocurrent spectra are also analyzed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigation of GaN-on-GaN vertical p - n diode with regrown p -GaN by metalorganic chemical vapor deposition

Here, to mimic selective-area doping, p -GaN was regrown on an etched GaN surface on GaN substrates by metalorganic chemical vapor deposition. Vertical GaN-on-GaN p - n diodes were fabricated to investigate the effects of the etch-then-regrowth process on device performance. The crystal quality of the sample after each epitaxial step was characterized by X-ray diffraction, where the etch-then-regrowth process led to a very slight increase in edge dislocations. A regrowth interfacial layer was clearly shown by transmission electron microscopy. Strong electroluminescence was observed with three emission peaks at 2.2 eV, 2.8 eV and 3.0 eV, respectively. The forward current density increased slightly with the increasing temperature, while the reverse current density was almost temperature independent indicating tunneling as the reverse transport mechanism. This result is very similar to the reported Zener tunnel diode comprising a high doping profile at the junction interface. High levels of silicon and oxygen concentrations were observed at the regrowth interface with a distribution width of ~100 nm. This work provides valuable information of p -GaN regrowth and regrown GaN p - n diodes, which can serve as an important reference for developing selective doping for advanced GaN power electronics for high voltage and high power applications.

42 ENGINEERING↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Beam-driven dynamics of aluminium dopants in graphene

Abstract Substituting heteroatoms into graphene can tune its properties for applications ranging from catalysis to spintronics. The further recent discovery that covalent impurities in graphene can be manipulated at atomic precision using a focused electron beam may open avenues towards sub-nanometer device architectures. However, the preparation of clean samples with a high density of dopants is still very challenging. Here, we report vacancy-mediated substitution of aluminium into laser-cleaned graphene, and without removal from our ultra-high vacuum apparatus, study their dynamics under 60 keV electron irradiation using aberration-corrected scanning transmission electron microscopy and spectroscopy. Three- and four-coordinated Al sites are identified, showing excellent agreement with ab initio predictions including binding energies and electron energy loss spectrum simulations. We show that the direct exchange of carbon and aluminium atoms predicted earlier occurs under electron irradiation, although unexpectedly it is less probable than the same process for silicon. We also observe a previously unknown nitrogen–aluminium exchange that occurs at Al–N double-dopant sites at graphene divacancies created by our plasma treatment.

36 MATERIALS SCIENCE↗