Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Representing Carbon Dioxide Transport and Storage Network Investments within Power System Planning Models

Carbon dioxide (CO 2 ) capture and storage (CCS) is frequently identified as a potential component to achieving a decarbonized power system at least cost; however, power system models frequently lack detailed representation of CO 2 transportation, injection, and storage (CTS) infrastructure. In this paper, we present a novel approach to explicitly represent CO 2 storage potential and CTS infrastructure costs and constraints within a continental-scale power system capacity expansion model. In addition, we evaluate the sensitivity of the results to assumptions about the future costs and performance of CTS components and carbon capture technologies. We find that the quantity of CO 2 captured within the power sector is relatively insensitive to the range of CTS costs explored, suggesting that the cost of CO 2 capture retrofits is a more important driver of CCS implementation than the costs of transportation and storage. Finally, we demonstrate that storage and injection costs account for the predominant share of total costs associated with CTS investment and operation, suggesting that pipeline infrastructure costs have limited influence on the competitiveness of CCS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Highly Insulated Wall Systems with Exterior Insulation of Polyisocyanurate under Different Facer Materials: Material Characterization and Long-Term Hygrothermal Performance Assessment

The application of exterior insulation in both new construction and retrofits is a common practice to enhance the energy efficiency of buildings. In addition to increased thermal performance, the rigid insulation can serve to keep the sheathing board warm and serve as a water-resistive barrier to keep moisture-related problems due to condensation and wind-driven rain. Polyisocyanurate (PIR) rigid boards have a higher thermal resistance in comparison to other commonly used exterior insulation boards. However, because of its perceived lower permeance, its use as exterior insulation is not very common. In this study, the hygrothermal property of PIR boards with different facer types and thicknesses is characterized. The material data obtained through experimental test and extrapolation is used in a long term hygrothermal performance assessment of a wood frame wall with PIR boards as exterior insulation. Results show that PIR with no facer has the smallest accumulated moisture on the sheathing board in comparison to other insulation boards. Walls with a bigger thickness of exterior insulation perform better when no vapor barrier is used. The PIR exterior insulation supports the moisture control strategy well in colder climates in perfect wall scenarios, where there is no air leakage and moisture intrusion. In cases where there is trapped moisture, the sheathing board has a higher moisture content with PIR boards with both aluminum or fiberglass type facers. An innovative facer material development for PIR boards can help efforts targeting improved energy-efficient and durable wall systems.

36 MATERIALS SCIENCE↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-Efficient Neuromorphic Architectures for Nuclear Radiation Detection Applications

A comprehensive analysis and simulation of two memristor-based neuromorphic architectures for nuclear radiation detection is presented. Both scalable architectures retrofit a locally competitive algorithm to solve overcomplete sparse approximation problems by harnessing memristor crossbar execution of vector–matrix multiplications. The proposed systems demonstrate excellent accuracy and throughput while consuming minimal energy for radionuclide detection. To ensure that the simulation results of our proposed hardware are realistic, the memristor parameters are chosen from our own fabricated memristor devices. Based on these results, we conclude that memristor-based computing is the preeminent technology for a radiation detection platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Green Roof Potential to Mitigate Urban Flooding in a Chinese City

The Middle and Lower Reaches of the Yangtze River (MLRYR) region, which has humid subtropical climate conditions and unique plum rain season, is characterized by a simultaneous high-frequency urban flooding and reduction in groundwater levels. Retrofitting the existing buildings into green roofs is a promising approach to combat urban flooding, especially for a densely developed city. Here, the application potential of the Green Roof System (GRS) and the Improved Green Roof System (IGRS) designed to divert overflowing water from green roofs to recharge groundwater were analyzed in a densely developed city, Nanchang, China. For the first time, the influence of GRS on the hydraulic condition of Combined Sewage System/Storm Water System (CSS/SWS) is analyzed, which is a direct reflection of the effect of GRS on alleviating urban flooding. The simulation results show that GRS can retain about 41–75% of precipitation in a 2-hour timescale and the flooding volumes in the GRS/IGRS region are 82% and 28% less than those of the Traditional Roof System (TRS) in 10- and 100-yr precipitation events, respectively. In the continuous simulations, GRS also enhances Evapotranspiration (ET), which accounts for 39% of annual precipitation, so that reduces the cumulative surface runoff. Considering the IGRS can provide more hydrological benefits than the GRS under the same climate conditions, we may conclude that the widespread implementation of both the GRS and the IGRS in Nanchang and other densely developed cities in the MLRYR region could significantly reduce surface and peak runoff rates.

54 ENVIRONMENTAL SCIENCES↗

Pool-Based Tow System for Testing Tethered Hydrokinetic Devices Being Developed to Harvest Energy From Ocean Currents

Abstract The immense potential for ocean current energy harvesting is being actively explored as the push for renewable energy becomes more urgent. This paper demonstrates a tow testing platform built to examine and validate mathematical models related to the performance of tethered, underwater, hydrokinetic devices in development to harvest energy from ocean currents, and presents experimental results illustrating how such a system can be used. The platform has been modularly designed to allow for the testing of various tethered, underwater energy-generation systems, including kite-based systems, coaxial turbines, and duct sails. Previous research on tethered energy-generating systems has primarily been focused on airborne systems. Additionally, the limited experimental research on tethered, underwater energy-generation systems has relied on a rigid rod for mechanical and electrical connections between the test articles and instrumentation. The tow testing platform presented in this paper accomplishes the mechanical and electrical connection through a dual-function tether, featuring internal conductors and an external sheath to support towing loads. The goal of this platform was to enable the emulation of ocean currents, which are largely unidirectional, and to retrofit a regular pool into a cost-effective, adaptable, small-scale tow tank test bed. The capabilities of the system include two-way communication with tethered devices, multiple towing profiles in order to emulate different flow regimes, real-time control, and differential velocities via dual winch operation.

Engineering↗

Mixing-Controlled Combustion of Ethanol Enabled by Prechamber Ignition (PC-MCC): A Preliminary Experimental Demonstration

This experimental study presents preliminary investigations of prechamber-enabled mixing-controlled combustion (PC-MCC) at −2 bar brake mean effective pressure (BMEP) and 2200 rpm with fuel-grade ethanol (E98). Experimental results are conducted on a prechamber retrofitted single-cylinder Caterpillar C9.3B test engine. First, a series of prechamber-only experiments were conducted with a motored engine to evaluate the salient combustion trends in response to relevant prechamber operating parameters. Under firing conditions, the prechamber operating strategy was assessed with respect to the impact on ignition assistance of direct-injected E98 and overall engine performance. The preliminary results indicate the jet-induced ignition process is robust and prompts diffusion combustion of E98 at diesel-like boundary conditions. Here, the effect of external exhaust gas recirculation (EGR) on the residual tolerance of the prechamber combustion process was also investigated and showed stable combustion in both the main chamber and prechamber up to 30% EGR. Experiments were also conducted with the stock diesel engine for baseline comparison. At matched combustion phasing, mixing-controlled combustion of ethanol enabled by prechamber ignition was able to achieve heightened gross thermal efficiency while simultaneously reducing NOx and practically eliminating smoke emissions relative to diesel combustion. In addition, the covariance of load and standard deviation of combustion phasing was diesel-like and less than 2% and 1 CAD, respectively.

PC-MCC↗

Deliver Signal Phase and Timing (SPAT) for Energy Optimization of Vehicle Cohort Via Cloud-Computing and LTE Communications

Predictive Signal Phase and Timing (SPAT) message set is one fundamental building block for vehicle-to-infrastructure (V2I) applications such as Eco-Approach and Departure (EAD) at traffic signal controlled urban intersections. Among the two complementary communication methods namely short-range sidelink (PC5) and long-range cellular radio link (Uu), this paper documents the work with long-range link: the complete data chain includes connecting to the traffic signals via existing backhaul communication network, collecting the raw signal phase state data, predicting the signal state changes and delivering the SPAT data via a geofenced service to requests over HTTP protocols. An Application Programming Interface (API) library is developed to support various cellular data transmission reduction and latency improvement techniques. An emulation-based algorithm is applied to predict the traffic signal state changes to provide adequate prediction horizon (e.g., at minimum 2 minutes) for the cohort energy optimization. In fact, the same connectivity and SPAT delivery methodology has been applied to traffic signalized intersections nationwide in the United States upon public agency approvals for access to their firewalled traffic control network and signal control systems or directly to individual controllers. This methodology proves its effectiveness and potential for rapid growth of such SPAT deliveries at mass production scale without needing infrastructure hardware retrofit or excessive communication means. To support the energy optimization of light and heavy-duty vehicle cohorts of mixed automation and propulsion systems (EV, ICE and hybrid), the connection and SPAT deliveries at two sites were completed, including public roads in Washtenaw County, Michigan and closed track test sites at American Center for Mobility (ACM) in Ypsilanti, Michigan. However, only closed test track results at ACM will be presented in this paper. A neuroevolution based optimizer is developed and implemented to control the speed of a vehicle cohort with different propulsion systems and automation levels. Closed track tests showed significant energy savings of the cohort operation.

99 GENERAL AND MISCELLANEOUS↗

Scout Benchmark Scenarios for U.S. Building Energy and CO2 Emissions to 2050

Overview and Intended Use Cases: These scenarios establish a range of futures for U.S. buildings sector energy use and CO2 emissions to 2050 using Scout (scout.energy.gov), a reproducible and granular model of U.S. building energy use, emissions, and consumer costs developed by the U.S. national labs for the U.S. Department of Energy's Building Technologies Office (BTO). Scout benchmark scenario data are suitable for the following example use cases: setting high-level policy goals for the U.S. buildings sector to 2050 (e.g., X% building CO2 emissions reductions vs. 2005 levels by 2030, Y% reductions vs. 2005 levels by 2050); exploring the effects of key dynamics driving U.S. buildings sector energy and CO2 emissions to 2050 that could be affected by policy levers (e.g., raising minimum technology performance levels; accelerating electrification and/or retrofit rates; introducing breakthrough technologies to the market); determining priority segments (regions, building types, and end use/technology types) and sequencing of U.S. buildings sector energy and CO2 emissions reductions to 2050 under a given set of assumptions; and/or identifying the energy and emissions impacts or cost effectiveness of specific technologies or operational approaches of interest—in isolation or after considering competition with other measures in a scenario portfolio. Scenario Summary: A total of 8 scenarios explore the effects of changes across both the demand- and supply-side of building energy use on annual U.S. building energy use and CO2 emissions from 2022–2050. Scenarios are organized into three groups representing low, moderate, and best-case potentials for building decarbonization, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Investigating Building Energy Consumption and CO2 Emission in Phoenix Using AutoBEM and Future Typical Meteorological Year (fTMY) Weather Data

This research investigates the energy performance and CO2 emissions of each building stock across the Phoenix metropolitan area using the Automatic Building Energy Modeling (AutoBEM) framework and Model America v2 (MAv2) dataset from Oak Ridge National Laboratory (ORNL). Typical Meteorological Year (TMY) and Future Typical Meteorological Year (fTMY) files were used for AutoBEM simulation. The simulation results from TMY and fTMY were compared. It was found that a projected 10.28% increase in total CO2 emissions and a 9.30% rise in total energy consumption by 2080–2099 relative to current typical conditions. The results highlight the disparities in emissions among different building stocks and the influence of climate change on future energy demand. The findings underscore the necessity of targeted policy interventions and retrofitting strategies (eg. advanced HVAC systems, improved insulation, reflective roofing) to mitigate emissions in high-energy-use and emission-intensed buildings, particularly as climate conditions evolve. This study contributes to the growing understanding of building-sector emissions and their long-term implications under future climate scenarios.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conceptual Design of Integrated Energy Systems with Market Interaction Surrogate Models

Most integrated energy system (IES) optimization frameworks employ the price-taker approximation, which ignores important interactions with the market and can result in overestimated economic values. In this work, we propose a machine learning surrogate-assisted optimization framework to quantify IES/market interactions and thus go beyond price-taker. We use time series clustering to generate representative IES operation profiles for the optimization problem and use machine learning surrogate models to predict the IES/market interaction. We quantify the accuracy of the time series clustering and surrogate models in a case study to optimally retrofit a nuclear power plant with a polymer electrolyte membrane electrolyzer to co-produce electricity and hydrogen.

Chen, Xinhe↗