Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Representations of relativistic particles of arbitrary spin in Poincaré, Lorentz, and Euclidean covariant formulations of relativistic quantum mechanics

Background: Relativistic treatments of quantum mechanical systems are important for understanding hadronic structure and dynamics at subnucleon scales. Relativistic invariance of a quantum system means that there is an underlying unitary representation of the Poincaré group. This is equivalent to the requirement that the quantum observables (probabilities, expectation values, and ensemble averages) for equivalent measurements performed in different inertial reference frames are identical. Different representations are used in practice, including Poincaré covariant forms of dynamics, representations based on Lorentz covariant wave functions, Euclidean covariant representations, and representations generated by Lorentz covariant fields. Purpose: The purpose of this work is to illustrate the relation between the different equivalent representations of states in relativistic quantum mechanics. Method: The starting point is a description of a particle of mass m and spin j using irreducible representations of the Poincaré group. Since any unitary representation of the Poincaré group can be decomposed into a direct integral of irreducible representations, these are the basic building blocks of any relativistically invariant quantum theory. The equivalence is established by constructing equivalent Lorentz covariant irreducible representations from Poincaré covariant irreducible representations and constructing equivalent Euclidean covariant irreducible representations from Lorentz covariant irreducible representations. Results: Equivalent descriptions for positive mass representations of arbitrary spin are presented in each of these frameworks. Dynamical realizations of the different representations are briefly discussed. Conclusion: Poincaré covariant, Lorentz covariant, and Euclidean covariant realizations of relativistic dynamics are shown to be equivalent by explicitly relating the positive-mass positive-energy irreducible representations of the Poincaré group that appear in the direct integral.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionization-induced thermally activated defect-annealing process in SiC

Ionizing events can lead to panoply of irradiation effects, and in silicon carbide (SiC), they drastically modify the defect production rate or the initial density. To better comprehend this phenomenon, 6H-SiC single crystals were first predamaged using low-velocity 100-keV Fe + ions at three fluences in the range of 10 14 cm -2 to induce three different initial disorder levels peaking at values between ~0.8 and 1 (1 corresponding to full amorphization). Crystals were then submitted to swift heavy ion irradiation in the 10 13 cm -2 fluence range at both low (~100 K) and high (~770 K) temperature. Rutherford backscattering spectrometry in channeling conditions revealed that swift ions allow annealing part of the initial damage, the recovery efficiency increasing with the irradiation temperature and reaching 75% in initially severely disordered crystals. This temperature effect has been qualitatively predicted by molecular dynamics simulations. Transmission electron microscopy allowed imaging both the recovery and the difference in the microstructure of the layers irradiated at low or high temperature. Recovery cross sections are discovered to lie in the range of a few square nanometers, consistent with previously reported values. A scenario for a general, two-step annealing mechanism referred to as an ionization-activated, thermally assisted defect-annealing (IATADA) process is proposed. This mechanism rationalizes the diverse descriptions reported so far in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dosimetry protocol for the preclinical trials in white-beam minibeam radiation therapy

Purpose: In the quest of a curative radiotherapy treatment for gliomas, new delivery modes are being explored. At the Biomedical Beamline of the European Synchrotron Radiation Facility, a new spatially fractionated technique, called minibeam radiation therapy (MBRT), is under development. The aims of this work were to assess different dosimetric aspects and to establish a dosimetry protocol to be applied in the forthcoming animal (rat) studies in order to evaluate the therapeutic index of this new radiotherapy approach. Methods: Absolute dosimetry was performed with a thimble ionization chamber (PTW semiflex 31010) whose center was positioned at 2 g cm{sup -2} depth. To translate the dose measured in broad beam configuration to the dose deposited with a minibeam, the scatter factors were used. Those were assessed by using the Monte Carlo simulations and verified experimentally with Gafchromic films and a Bragg Peak chamber. The comparison of the theoretical and experimental data were used to benchmark the calculations. Finally, the dose distributions in a rat phantom were evaluated by using the validated Monte Carlo calculations. Results: The absolute dosimetry in broad beam configuration was measured in reference conditions. The dose rate was in the range between 168 and 224 Gy/min, depending on the storage ring current. A scatter factor of 0.80 {+-} 0.04 was obtained. Percentage depth dose and lateral profiles were evaluated both in homogenous and heterogeneous slab phantoms. The general good agreement between Monte Carlo simulations and experimental data permitted the benchmark of the calculations. Finally, the peak doses in the rat head phantom were assessed from the measurements in reference conditions. In addition, the peak-to-valley dose ratio values as a function of depth in the rat head were evaluated. Conclusions: A new promising radiotherapy approach is being explored at the ESRF: Minibeam Radiation Therapy. To assess the therapeutic index of this new modality, in vivo experiments are being planned, for which an accurate knowledge of the dosimetry is essential. For that purpose, a complete set of measurements and Monte Carlo simulations was performed. The first dosimetry protocol for preclinical trials in minibeam radiation therapy was established. This protocol allows to have reproducibility in terms of dose for the different biological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-35: A General Fill Factor Definition Serving to Characterise the MLC Misalignment Detection Capabilities of Two-Dimensional Detector Arrays

Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al.{sup 1} the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detector cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm{sup 2} for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References:{sup 1}A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)

60 APPLIED LIFE SCIENCES↗

TU-EF-304-08: LET-Based Inverse Planning for IMPT

Purpose: Cell survival experiments suggest that the relative biological effectiveness (RBE) of proton beams depends on linear energy transfer (LET), leading to higher RBE near the end of range. With intensity-modulated proton therapy (IMPT), multiple treatment plans that differ in the dose contribution per field may yield a similar physical dose distribution, but the RBE-weighted dose distribution may be disparate. RBE models currently do not have the required predictive power to be included in an optimization model due to the variations in experimental data. We propose an LET-based planning method that guides IMPT optimization models towards plans with reduced RBE-weighted dose in surrounding organs at risk (OARs) compared to inverse planning based on physical dose alone. Methods: Optimization models for physical dose are extended with a term for dose times LET (doseLET). Monte Carlo code is used to generate the physical dose and doseLET distribution of each individual pencil beam. The method is demonstrated for an atypical meningioma patient where the target volume abuts the brainstem and partially overlaps with the optic nerve. Results: A reference plan optimized based on physical dose alone yields high doseLET values in parts of the brainstem and optic nerve. Minimizing doseLET in these critical structures as an additional planning goal reduces the risk of high RBE-weighted dose. The resulting treatment plan avoids the distal fall-off of the Bragg peaks for shaping the dose distribution in front of critical stuctures. The maximum dose in the OARs evaluated with RBE models from literature is reduced by 8–14\% with our method compared to conventional planning. Conclusion: LET-based inverse planning for IMPT offers the ability to reduce the RBE-weighted dose in OARs without sacrificing target dose. This project was in part supported by NCI - U19 CA 21239.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

H2A-Lite (Hydrogen Analysis Lite Production Model) [SWR-24-69]

Within H2A-Lite, users can provide a minimal number of inputs—such as hydrogen production technology of choice —to produce estimates about characteristic scale, capital, and operations. Price projections for energy and feedstock are based on the Energy Information Administration's Annual Energy Outlook 2022, AEO2022 Reference case. The model additionally allows users to override technology default values to adapt to specific technology scales or regional energy prices. As output, H2A-Lite provides cost breakdown from rigorous financial analysis as well as greenhouse gas and criteria pollutant emissions characteristics.

Penev, Michael [National Laboratory of the Rockies↗

Evaluation of PV performance models and their impact on project risk.

Photovoltaic systems are often priced in $/W{sub p}, where Wp refers to the DC power rating of the modules at Standard Test Conditions (1000 W/m{sup 2}, 25 C cell temperature) and $ refers to the installed cost of the system. However, the true value of the system is in the energy it will produce in kWhs, not the power rating. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, the annual energy yield (kWh/kW{sup p}) will vary among module technologies because of differences in response to low-light levels and temperature. Understanding energy yield is a key part of understanding system value. System performance models are used during project development to estimate the expected output of PV systems for a given design and location. Performance modeling is normally done by the system designer/system integrator. Often, an independent engineer will also model system output during a due diligence review of a project. A variety of system performance models are available. The most commonly used modeling tool for project development and due diligence in the United States is probably PVsyst, while those seeking a quick answer to expected energy production may use PVWatts. In this paper, we examine the variation in predicted energy output among modeling tools and users and compare that to measured output.

14 SOLAR ENERGY↗

Reuse of Material Containing Natural Radionuclides - 12444

Disposal of and use of wastes containing natural radioactive material (NORM) or technologically enhanced natural radioactive material (TENORM) with excessive natural background as a building material is very important in the supervision body activity. At the present time, the residents of Octyabrsky village are under resettlement. This village is located just near the Priargunsky mining and chemical combine (Ltd. 'PPGHO'), one of the oldest uranium mines in our country. The vacated wooden houses in the village are demolished and partly used as a building material. To address the issue of potential radiation hazard of the wooden beams originating from demolition of houses in Octyabrsky village, the contents of the natural radionuclides (K-40, Th-232, Ra-226, U- 238) are being determined in samples of the wooden beams of houses. The NORM contents in the wooden house samples are higher, on average, than their content in the reference sample of the fresh wood shavings, but the range of values is rather large. According to the classification of waste containing the natural radionuclides, its evaluation is based on the effective specific activity. At the effective specific activity lower 1.5 kBq/kg and gamma dose rate lower 70 μR/h, the material is not considered as waste and can be used in building by 1 - 3 classes depending upon A{sub eff} value. At 1.5 kBq/kg < A{sub eff} ≤ 4 kBq/kg (4 class), the wooden beams might be used for the purpose of the industrial building, if sum of ratios between the radionuclide specific activity and its specific activity of minimum significance is lower than unit. The material classified as the waste containing the natural radionuclides has A{sub eff} higher 1.5 kBq /kg, and its usage for the purpose of house-building and road construction is forbidden. As for the ash classification and its future usage, such usage is unreasonable, because, according to the provided material, more than 50% of ash samples are considered as radioactive waste containing natural radionuclides. All materials originated from demolition of houses in Octyabrsky village are subjected to the obligatory radiation control. The decision to use the wooden beams shall enter into force after agreement with the State Sanitary and Epidemiological Supervision bodies. Conclusions: 1 - The wooden beam originated from the house demolition in Octyabrsky village might be used as the construction material only in case of compliance with the requirements of the regulatory documents, as well as under approval of the authorities responsible for the state sanitary and epidemiological supervision in this area. 2 - The industrial control is introduced to verify the compliance with the current regulations. 3 - The material originated from the house demolition might be used only if such usage does not cause increasing radiation exposure to the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF VADOSE-ZONE HYDRAULIC PARAMETER VALUES

Several approaches have been developed to establish a relation between the soil-moisture retention curve and readily available soil properties. Those relationships are referred to as pedotransfer functions. Described in this paper are the rationale, approach, and corroboration for use of a nonparametric pedotransfer function for the estimation of soil hydraulic-parameter values at the yucca Mountain area in Nevada for simulations of net infiltration. This approach, shown to be applicable for use at Yucca Mountain, is also applicable for use at the Hanford Site where the underlying data were collected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-stage formation-energy correction (NbZr, TaZr, VZr)

This bundle contains the scripts, the raw and corrected per-structure data, and the manuscript plots for the NbZr / TaZr / VZr BCC binary formation energies and the associated RMSDs. Why a two-stage correction is necessary: The "raw" formation energy of every relaxed VASP configuration is computed in the usual way, FE_raw(c) = E_alloy(c) - sum_i x_i * E_pure_i , where E_pure_i are the per-atom total energies of the pure-element reference structures (Nb, Ta, V, Zr in the same BCC supercell, with identical INCAR / KPOINTS / PAW choices). With perfectly consistent reference runs the raw FE should vanish at the two pure-element endpoints (x = 0 and x = 1) by construction. In practice this does not hold for two reasons that are present in our dataset: 1. Reference-energy inconsistency (composition-dependent bias). Even with identical input parameters, the pure-element runs (stored in `corrected_DFT_pure_element_runs/`) differ slightly from the values that would be implied by the alloy runs at near-pure compositions (a few meV/atom). This bias is approximately linear in concentration, because the residual error in E_pure_Nb (or E_pure_Ta / E_pure_V) propagates into FE_raw(c) as (1 - x) * dE_pure_1, and the corresponding error in E_pure_Zr propagates as x * dE_pure_2. Left uncorrected, this produces a non-physical "tilt" of FE_raw(x) and shifts the entire FE-vs-x cloud away from zero at the endpoints. 2. Endpoint anchoring against the audited true endpoints. The strict endpoint values (FE_x0_meVatom, FE_x1_meVatom in `corrected_fe_strict_endpoints_20260518/strict_endpoint_check_20260518.csv`) were re-derived from an independent cross-check of the pure-element runs. After stage 1 removes the linear bias, the near-pure compositions in the alloy dataset still extrapolate to values that differ slightly from these audited endpoints — because stage 1 is fit from a few near-end alloy bins, not from the audited pure-element references themselves. The README.txt file discusses how these issues are addressed by the two-stage correction, and describes folder layout, pipeline summary, and how to re-run.

36 MATERIALS SCIENCE↗

Reformulation of Density Functional Theory for N-Representable Densities and the Resolution of the v-Representability Problem

Density functional theory for the case of general, N-representable densities is reformulated in terms of density functional derivatives of expectation values of operators evaluated with wave functions leading to a density, making no reference to the concept of potential. The developments provide a complete solution of the v-representability problem by establishing a mathematical procedure that determines whether a density is v-representable and in the case of an affirmative answer determines the potential (within an additive constant) as a derivative with respect to the density of a constrained search functional. It also establishes the existence of an energy functional of the density that, for v-representable densities, assumes its minimum value at the density describing the ground state of an interacting many-particle system. The theorems of Hohenberg and Kohn emerge as special cases of the formalism.

36 MATERIALS SCIENCE↗

Efficient optimal minimum error discrimination of symmetric quantum states

This article deals with the quantum optimal discrimination among mixed quantum states enjoying geometrical uniform symmetry with respect to a reference density operator rho{sub 0}. It is well known that the minimal error probability is given by the positive operator-valued measure obtained as a solution of a convex optimization problem, namely a set of operators satisfying geometrical symmetry, with respect to a reference operator PI{sub 0} and maximizing Tr(rho{sub 0}PI{sub 0}). In this article, by resolving the dual problem, we show that the same result is obtained by minimizing the trace of a semidefinite positive operator X commuting with the symmetry operator and such that X>=rho{sub 0}. The new formulation gives a deeper insight into the optimization problem and allows to obtain closed-form analytical solutions, as shown by a simple but not trivial explanatory example. In addition to the theoretical interest, the result leads to semidefinite programming solutions of reduced complexity, allowing to extend the numerical performance evaluation to quantum communication systems modeled in Hilbert spaces of large dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Group Additivity Determination for Oxygenates, Oxonium Ions, and Oxygen-Containing Carbenium Ions

Bio-oil produced from biomass fast pyrolysis often requires catalytic upgrading to remove oxygen and acidic species over zeolite catalysts. The elementary reactions in the mechanism for this process involve carbenium and oxonium ions. In order to develop a detailed kinetic model for the catalytic upgrading of biomass, rate constants are required for these elementary reactions. The parameters in the Arrhenius equation can be related to thermodynamic properties through structure-reactivity relationships, such as the Evans-Polanyi relationship. For this relationship, enthalpies of formation of each species are required, which can be reasonably estimated using group additivity. However, the literature previously lacked group additivity values for oxygenates, oxonium ions, and oxygen-containing carbenium ions. In this work, 71 group additivity values for these types of groups were regressed, 65 of which had not been reported previously and six of which were newly estimated based on regression in the context of the 65 new groups. Heats of formation based on atomization enthalpy calculations for a set of reference molecules and isodesmic reactions for a small set of larger species for which experimental data was available were used to demonstrate the accuracy of the Gaussian-4 quantum mechanical method in estimating enthalpies of formation for species involving the moieties of interest. Isodesmic reactions for a total of 195 species were constructed from the reference molecules to calculate enthalpies of formation that were used to regress the group additivity values. The results showed an average deviation of 1.95 kcal/mol between the values calculated from Gaussian-4 and isodesmic reactions versus those calculated from the group additivity values that were newly regressed. Importantly, the new groups enhance the database for group additivity values, especially those involving oxonium ions.

09 BIOMASS FUELS↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Stable Adaptive Inertial Control of a Doubly-Fed Induction Generator

This paper proposes a stable adaptive inertial control scheme of a doubly-fed induction generator. The proposed power reference is defined in two sections: the deceleration period and the acceleration period. The power reference in the deceleration period consists of a constant and the reference for maximum power point tracking (MPPT) operation. The latter contributes to preventing a second frequency dip (SFD) in this period because its reduction rate is large at the early stage of an event but quickly decreases with time. To improve the frequency nadir (FN), the constant value is set to be proportional to the rotor speed prior to an event. The reference ensures that the rotor speed converges to a stable operating region. To accelerate the rotor speed while causing a small SFD, when the rotor speed converges, the power reference is reduced by a small amount and maintained until it meets the MPPT reference. The results show that the scheme causes a small SFD while improving the FN and the rate of change of frequency in any wind conditions, even in a grid that has a high penetration of wind power.

24 POWER TRANSMISSION AND DISTRIBUTION↗