Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

A scanning multichannel microwave radiometer for Nimbus-G and SeaSat-A

A scanning multichannel microwave radiometer (SMMR) has been designed for the Nimbus-G spacecraft and incorporated also into the SeaSat-A payload for the primary purpose of determining sea surface temperatures and wind stress on a nearly all-weather basis. Observations of microwave polarization components will be made at wavelengths of 0.8, 1.4, 1.7, 2.8, and 4.6 cm over a swath 822 km wide below the Nimbus-G and 595 km wide below the SeaSat-A spacecraft. The smallest spatial resolution cell is about 20 km at a wavelength of 0.8 cm, and proportionately larger at the other wavelengths. Using algorithms based on a combination of experimental data and physical models for converting the observed brightness temperatures, the indicated accuracy of the results (excluding conditions of significant rainfall) are within 1 K for sea surface temperature and 2 m/s for surface wind speeds, over a range from 0-50 m/s.

Gloersen, P.↗

Estimating regional heat flux from scanning radiometer data

Method using matrix approach to determine best linear estimate of total flux consistent with condition of minimum variance proves useful in meteorological studies. It is useful for researchers studying options in scanner design such as scan pattern, scan rate, and radiometer field-of-view.

Bess, T. D.↗

Data processing for the DMSP microwave radiometer system

A software program was developed and tested to process microwave radiometry data to be acquired by the microwave sensor (SSM/T) on the Defense Meteorological Satellite Program spacecraft. The SSM/T 7-channel microwave radiometer and systems data will be data-linked to Air Force Global Weather Central (AFGWC) where they will be merged with ephemeris data prior to product processing for use in the AFGWC upper air data base (UADB). The overall system utilizes an integrated design to provide atmospheric temperature soundings for global applications. The fully automated processing at AFGWC was accomplished by four related computer processor programs to produce compatible UADB soundings, evaluate system performance, and update the a priori developed inversion matrices. Tests with simulated data produced results significantly better than climatology.

Rigone, J. L.↗

Advanced very high resolution radiometer

The advanced very high resolution radiometer development program is considered. The program covered the design, construction, and test of a breadboard model, engineering model, protoflight model, mechanical structural model, and a life test model. Special bench test and calibration equipment was also developed for use on the program.

Source record↗

Frequency selection and calibration of a water vapor radiometer

The calibration coefficients of existing water vapor radiometers are dependent upon meteorology profiles. This is shown to be due mainly to incorrect frequency pairs. By properly selecting an optimum frequency pair, the dependency can be reduced to a relatively small amount which can be handily adjusted by surface measurement alone. Hence, a universal calibration equation is applicable to all environmental conditions - site, seasonal and diurnal variations. Optimum frequency pairs are systematically searched. Error analysis indicates that calibration for the water vapor phase delay accurate to less than 2 cm is possible at all elevation angles greater than 15 degrees.

Wu, S. C.↗

Advanced microwave radiometer antenna system study

The practicability of a multi-frequency antenna for spaceborne microwave radiometers was considered in detail. The program consisted of a comparative study of various antenna systems, both mechanically and electronically scanned, in relation to specified design goals and desired system performance. The study involved several distinct tasks: definition of candidate antennas that are lightweight and that, at the specified frequencies of 5, 10, 18, 22, and 36 GHz, can provide conical scanning, dual linear polarization, and simultaneous multiple frequency operation; examination of various feed systems and phase-shifting techniques; detailed analysis of several key performance parameters such as beam efficiency, sidelobe level, and antenna beam footprint size; and conception of an antenna/feed system that could meet the design goals. Candidate antennas examined include phased arrays, lenses, and optical reflector systems. Mechanical, electrical, and performance characteristics of the various systems were tabulated for ease of comparison.

Kummer, W. H.↗

Geosynchronous Microwave Atmospheric Sounding Radiometer (MASR) antenna feasibility study. Volume 3: Antenna feasibility

Antenna systems capable of operating with a multichannel microwave radiometer intended for mapping severe storm activity over patches on the surface of the earth 750 km square were compared. These systems included a paraboloidal reflector with an offset focal point feed, and a symmetrical Cassegrain reflector system. Both systems are acceptable from the point of view of beam efficiency, however, from the point of view of maintaining the required positional accuracies and surface tolerances, as well as from the point of view of manufacturability, cost effectiveness, and technical risk, the symmetrical Casegrain was selected as the preferred configuration. Performance characteristics were calculated and a mechanical design study was conducted to provide estimates of the technical risk, costs, and development time required for the construction of such an antenna system.

Villeneuve, A. T.↗

The Seasat-A Scanning Multichannel Microwave Radiometer

A Scanning Multichannel Microwave Radiometer has been designed for the Nimbus-G Spacecraft and incorporated also into the Seasat-A payload for the primary purpose of determining sea surface temperatures and wind stress on a nearly all-weather basis. Observations of microwave polarization components will be made at wavelengths of 0.8, 1.4, 1.7, 2.8, and 4.6 cm over a swath 577 km wide below the Seasat-A spacecraft. The smallest spatial resolution cell is 15 x 23 km at a wavelength of 0.8 cm, and proportionately larger at the other wavelengths. Using experimentally determined algorithms for converting the observed brightness temperatures, the indicated accuracies of the results (excluding conditions of significant rainfall) are within 1 K for sea surface temperature and 2 m/sec for surface wind speeds, over a range from 0-50 m/sec.

Gloersen, P.↗

Noise calibration repeatability of an airborne third-generation radiometer

A third-generation S-band radiometer has been calibrated at intervals over 3.5 years. The built-in stabilization concepts have proven to be very effective. In spite of some nonideal conditions (on runway, in wind, and in rain), an rms value of 0.7-K calibration repeatability has been observed with an average temperature deviation (bias error) of 0.03 K.

Blume, H.-J. C.↗

Estimation of regional heat flux from scanning radiometer measurements

The paper presents a statistical method for extracting regional information on the radiative heat flux at the top of the atmosphere from a satellite-borne scanning radiometer. The radiative heat flux distribution is denoted by a double Fourier series with coefficients to be determined from measurements. The method determines, in the sense of minimum variance, the best linear estimator of the total flux over a region. The heat flux distribution is represented by a truncated series which is unbiased.

Bess, T. D.↗

High resolution soil moisture radiometer

An electrically scanned pushbroom phased antenna array is described for a microwave radiometer which can provide agriculturally meaningful measurements of soil moisture. The antenna size of 100 meters at 1400 MHz or 230 meters at 611 MHz requires several shuttle launches and orbital assembly. Problems inherent to the size of the structure and specific instrument problems are discussed as well as the preliminary design.

Wilheit, T. T.↗

Microwave radiometer measurement of water vapor path delay: Data reduction techniques

Data reduction techniques are developed to compensate for water vapor path delay, a limiting error source in geodetic measurements made with very long baseline interferometry and in radio ranging to spacecraft. It is shown that water vapor path delay is proportional to a linear combination of saturation-corrected sky brightness temperatures, measured on and off the water vapor line. The effects of emission from liquid water droplets in clouds as well as most of the oxygen emission are removed by the off-line channel. Sky brightness temperatures are saturation-corrected or 'linearized' using estimates of effective sky temperatures made from surface temperature. Tipping curves are used to remove instrumental error. Coefficients are found by two methods: from a regression analysis of measured brightness temperatures versus radiosonde measured delay, and from a regression analysis of theoretical brightness temperatures versus radiosonde measured delay. In each case the coefficients are adjusted for differing climatic conditions by measurements of surface temperature, pressure, and relative humidity. Regression solutions are constrained to remove liquid water contributions and to give the correct slope for radiometer versus radiosonde path delay.

Claflin, E. S.↗

DSN water vapor radiometer development: Recent work, 1978

A water vapor radiometer (WVR) was developed that measures the atmospheric noise temperature at two different frequencies near 22 GHz. These noise temperature are used in empirical-theoretical equations that yield tropospheric range delay, in centimeters, through the atmosphere along the beam of the WVR. This range correction is then applied, as needed, to measurements concerning spacecraft range and to VLBI baseline determinations. The WVR design and calibration techniques are discussed.

Batelaan, P. D.↗

Objective tropical cyclone analysis and forecasting technique using conventional and Nimbus-5 electrically scanning microwave radiometer measurements

The ADAPT empirical analysis programs, based on finding an optimal representation of the data in the Karhunen-Loeve sense, were applied to 120 observations of twenty-nine 1973 and 1974 Pacific tropical cyclones. Each observation consists of NIMBUS-5 electrically scanning microwave radiometer (ESMR) radiation measurements at 267 grid points covering and surrounding the tropical cyclone plus nine other non-satellite derived descriptors. Analysis and forecast algorithms to estimate storm motion and intensity were developed for times ranging from the observation time up to 72 hours later. The 24 hr wind speed forecasts with an accuracy of 11.7 knots and position forecasts with accuracies 15% better than persistence were demonstrated using independent tests.

Hunter, H. E.↗

Scanning and focusing mechanisms of METEOSAT radiometer

Two mechanisms, both of screw-jack type are described. The scanning mechanism, an oil lubricated and sealed unit drives and accurately positions the telescope of the METEOSAT radiometer. The dry lubricated focusing mechanism is used to adjust the focus of this telescope. The METEOSAT program is nearly completed, and the first flight model will be launched at the end of the year.

Jouan, J.↗