Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Critical Configuration and Physics Mesaurements for Graphite Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.27-CM Pitch)

A series of critical experiments were completed in 1962-1965 at Oak Ridge National Laboratory's Critical Experiments Facility in support of the Medium-Power Reactor Experiments (MPRE) program. In the late 1950's efforts were made to study 'power plants for the production of electrical power in space vehicles'. The MPRE program was a part of those efforts and studied the feasibility of a stainless steel system, boiling potassium 1 MW(t), or about 140 kW(e), reactor. The program was carried out in FY 1964, 1965, and 1966. A summary of the program's effort was compiled in 1967. The delayed critical experiments served as a mockup of a small, potassium-cooled space power reactor for validation of reactor calculations and reactor physics methods. Initial experiments, performed in November and December of 1962, consisted of a core of unmoderated 253 stainless steel tubes, each containing 26 UO 2 fuel pellets, surrounded by a graphite reflector. Measurements were made to determine critical reflector arrangements, fission-rate distributions, and cadmium ratio distributions. Subsequent experiments used beryllium reflectors and also measured the reactivity for various materials placed in the core. 'The [assemblies were built] on [a] vertical assembly machine so that the movable part was the core and bottom reflector.' The experiment studied within this evaluation was the first of the series and had the 253 fuel tubes packed tightly into a 22.87 cm outside diameter (OD) core tank. Two critical configurations were found by varying the amount of graphite reflector (References 1 and 2). Information for this evaluation was compiled from Reference 1 and 2, reports on subsequent experiments in the series, and the experimental logbook as well as from communication with the experimenter, John T. Mihalczo.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Configuration for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-CM Pitch and 7-Tube Clusters)

A series of critical experiments were completed in 1962-1965 at Oak Ridge National Laboratory’s Critical Experiments Facility in support of the Medium-Power Reactor Experiments (MPRE) program. In the late 1950’s efforts were made to study “power plants for the production of electrical power in space vehicles”. The MPRE program was a part of those efforts and studied the feasibility of a stainless steel system, boiling potassium 1 MW(t), or about 140 kW(e), reactor. The program was carried out in [fiscal years] 1964, 1965, and 1966. A summary of the program’s effort was compiled in 1967. The delayed critical experiments were a mockup of a small, potassium-cooled space power reactor for validation of reactor calculations and reactor physics methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

reactivity worth measurements↗

Water-Moderated U(4.31)O 2 Fuel Rod Lattices Containing Rhodium Foils

The US Department of Energy Nuclear Energy Research Initiative (NERI) funded the Burnup Credit Critical Experiment (BUCCX) at Sandia National Laboratories. The BUCCX was designed to investigate the effect of fission product materials on critical systems. The BUCCX assembly was a water-moderated and -reflected array of Zircaloy-clad triangular-pitched U(4.31%)0 2 fuel elements. Some of the fuel elements could be opened to allow placement of experiment materials between the fuel pellets in the element. The ten BUCCX critical experiments reported here test the effect of the fission product rhodium on the assembly. The calculated reactivity worth of the rhodium in the experiments ranged from 0% for cases with no rhodium to a maximum of 3.5% of k eff .

103-1-↗

Titanium and/or Aluminum Sleeve Experiments in Fully-Reflected Water-Moderated U(4.31)O 2 Fuel Rod Lattices with 2.8 cm Pitch.

The US Department of Energy Nuclear Energy Research Initiative (NERI) funded the Bumup Credit Critical Experiment (BUCCX) at Sandia National Laboratories. The BUCCX was designed to investigate the effect of fission product materials on critical systems. The BUCCX assembly is a water-moderated and -reflected array of Zircaloy-clad triangular-pitched U(4.31)02 fuel elements. The original BUCCX experiments with rhodium are evaluated in LEU-COMP-THERM-079. In the experiments here, sets of up to 60 experiment titanium and aluminum sleeves with nominal outside diameter of 1 in (2.54 cm), wall thickness of 0.035 in (0.0889 cm), and length of 19.60 (49.784 cm) were fabricated. The sleeves are approximately the same length as the fueled section of the fuel elements and have an inner diameter that is 0.421 in (1.0693 cm) larger than the fuel elements. This allows for each sleeve to be centered around a fuel element between the grid plates within the array. Configurations differ by the number and location of sleeves. The seventeen BUCCX critical experiments reported here compare the effects of the titanium and aluminum sleeves on nearly critical fuel assembly arrays.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation of a Solid-Rod Cathode in a Low-Pressure Discharge

Cathode erosion is one of the life-limiting mechanisms in several classes of electric thrusters. Since cathode erosion depends strongly on the cathode temperature, a quantitative understanding of the effects of cathode operation in the cathode temperature is required. A pure tungsten cathode was sucessfully operated in an argon discharge at pressures of 1.5 and 3.0 kPa and current levels of 600, 1000 and 1400 A.

cathode erosion cathode temperature cathode operat↗

Irradiation of SiC Clad Fuel Rods in the HFIR

During 2009 and- 2010, new test capability for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) was developed that allows testing of advanced nuclear fuels and cladding under prototypic light-water-reactor (LWR) operating conditions (i.e., cladding and fuel temperatures, fuel average linear heat generation rates, and cladding fluence). For the initial experiments for this test program, ORNL teamed with commercial fuel/cladding vendors who have developed an advanced composite-wound SiC cladding material for possible use in LWRs. The first experiment, containing SiC-clad UN fuel, was inserted in HFIR in June 2010, and the second experiment, containing SiC-clad UO2 fuel, was inserted in October 2010. Two capsules (one containing UN fuel and the other UO2) were withdrawn from their respective assemblies in November 2011 at an estimated fuel burnup of approximately 10 GWd/MTHM; and two capsules (one containing UN fuel and the other UO2) were withdrawn from their respective assemblies in February 2013 at an estimated fuel burnup of approximately 20 GWd/MTHM. These capsules are currently awaiting PIE. This paper will describe the experiment, as-run operating conditions for these capsules, and current PIE plans and status.

Irradiation SiC fuel rods HFIR↗