Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical response from terahertz to visible light of electronuclear transitions in LiYF 4 : Ho3 +

Because of its role as a model system with tunable quantum fluctuations and quenched disorder, and the desire for optical control and readout of its states, we have used high-resolution optical absorption spectroscopy to measure the crystal-field excitations for Ho 3+ ions in LiHo x Y 1-x F 4 from the terahertz to visible regimes. We show that many of the excitations yield very narrow lines visibly split even by the nuclear hyperfine interaction, making Ho 3+ in LiHo x Y 1-x F 4 a candidate host for optically addressable electronuclear qubits with quality factors as high as Q = 4.7 × 10 5 , where the higher-lying levels are electronic singlets. Optical transitions in the easily accessible near- and mid-infrared are narrow enough to allow readout of the ground-state electronuclear qubits responsible for the interesting magnetism of LiHo x Y 1-x F 4 . While many of the higher-lying states have been observed previously, we also report here detailed spectra of terahertz excitations. The strengths of the electric and magnetic dipole crystal-field transition lines of five of the lowest excited spin-orbit manifolds of dilute LiYF 4 : Ho 3+ were calculated and compared with measurement. Finally, the magnitude of the nuclear hyperfine coupling was used to assign the correct upper and lower states to transition lines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

Here, we present results from a 3.25 kg–day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ~7 events per kg-day and electron-equivalent energies of ~80 eV, whose origin remains unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimating the energy threshold of phonon-mediated superconducting qubit detectors operated in an energy-relaxation sensing scheme

In recent years, the lack of a conclusive detection of weakly interacting massive particle dark matter at the 10 GeV/c 2 mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair in most superconductors. Among them, devices based on superconducting qubits are interesting candidates for sensing due to their observed sensitivity to broken Cooper pairs. Here, we have developed an end-to-end G 4 CMP -based simulation framework and have used it to evaluate performance metrics of qubit-based devices operating in a gate-based “energy relaxation” readout scheme, akin to those used in recent studies of qubit sensitivity to ionizing radiation. We find that for this readout scheme, the qubit acts as a phonon sensor with an energy threshold ranging down to ≃ 0.4 eV for near-term performance parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The Quantum Instrumentation Control Kit (QICK) is a standalone open-source qubit controller that was first introduced in 2022. In this follow-up work, we present recent upgrades to the QICK and the experimental use cases they uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, predistorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Backaction-evading receivers with magnetomechanical and electromechanical sensors

Today's mechanical sensors are capable of detecting extremely weak perturbations while operating near the standard quantum limit. However, further improvements can be made in both sensitivity and bandwidth when we reduce the noise originating from the process of measurement itself—the quantum-mechanical backaction of measurement—and go below this ‘standard’ limit, possibly approaching the Heisenberg limit. One of the ways to eliminate this noise is by measuring a quantum nondemolition variable such as the momentum in a free-particle system. Here, we propose and characterize theoretical models for direct velocity measurement that utilize traditional electric and magnetic transducer designs to generate a signal while enabling this backaction evasion. We consider the general readout of this signal via electric or magnetic field sensing by creating toy models analogous to the standard optomechanical position-sensing problem, thereby facilitating the assessment of measurement-added noise. Using simple models that characterize a wide range of transducers, we find that the choice of readout scheme—voltage or current—for each mechanical detector configuration implies access to either the position or velocity of the mechanical subsystem. This in turn suggests a path forward for key fundamental physics experiments such as the direct detection of dark matter particles. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of quasiparticle generation by microwave drives in superconducting qubits

Microwave drives play a central role in the control of superconducting quantum circuits, enabling qubit gates, readout, and parametric interactions. As the drive frequencies are typically an order of magnitude smaller than (twice) the superconducting gap, it is generally assumed that such drives do not disturb the BCS ground state. However, sufficiently strong drives can activate multiphoton pair-breaking processes that generate quasiparticles (QPs) and result in qubit errors. In this work, we present a theoretical framework for calculating the rates of multiphoton-assisted pair-breaking transitions induced by charge- or flux-coupled microwave drives. Through illustrative examples, we show that photon-assisted QP generation may affect novel high-frequency dispersive readout architectures, as well as Floquet-engineered superconducting circuits operating under strong driving.

circuit quantum electrodynamics↗

Offset Charge Dependence of Measurement-Induced Transitions in Transmons

A key challenge in achieving scalable fault tolerance in superconducting quantum processors is readout fidelity, which lags behind one- and two-qubit gate fidelity. A major limitation in improving qubit readout is measurement-induced transitions, also referred to as qubit ionization, caused by multiphoton qubit-resonator excitation occurring at specific photon numbers. Since ionization can involve highly excited states, it has been predicted that in transmons—the most widely used superconducting qubit—the photon number at which measurement-induced transitions occur is gate-charge dependent. This dependence is expected to persist deep in the transmon regime where the qubit frequency is gate-charge insensitive. We experimentally confirm this prediction by characterizing measurement-induced transitions with increasing resonator photon population while actively calibrating the transmon’s gate charge. Furthermore, because highly excited states are involved, achieving quantitative agreement between theory and experiment requires accounting for higher-order harmonics in the transmon Hamiltonian.

Quantum circuits↗

Pixelated transmission-mode diamond X-ray detector

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60–100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ~1 kHz, which leads to an image sampling rate of ~30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5–15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10 -2 to 90 W mm -2 . Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental results from the characterization of a 32-channels mixed-signal processor for the GAPS experiment

This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.

Riceputi, Elisa↗

Measurements of DC SQUID Damping Effects on Superconducting Resonant Circuits

Here, we present experimental measurements of SQUID-induced damping effects on strongly coupled, lumped-element resonators in the 500kHz–1 MHz frequency range. While dc SQUIDs are commonly used for sensitive readout of electromagnetic signals such as in lumped-element axion dark matter searches, coupling a dc SQUID to a resonant circuit modifies the circuit's resonance frequency, quality factor, noise, and impedance. These parameters have a direct impact on the science reach of axion dark matter detectors, making it important to understand SQUID damping contributions. We describe a helium dip probe and two-stage SQUID readout scheme used to probe SQUID damping effects. Measurements from this setup inform the design and operation of both future test platforms as well as next-generation dark-matter experiments.