Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tritium handling experience at Atomic Energy of Canada Limited

Canada has been a leader in tritium handling technologies as a result of the successful CANDU reactor technology used for power production. Over the last 50 to 60 years, capabilities have been established in tritium handling and tritium management in CANDU stations, tritium removal processes for heavy and light water, tritium measurement and monitoring, and understanding the effects of tritium on the environment. This paper outlines details of tritium-related work currently being carried out at Atomic Energy of Canada Limited (AECL). It concerns the CECE (Combined Electrolysis and Catalytic Exchange) process for detritiation, tritium-compatible electrolysers, tritium permeation studies, and tritium powered batteries. It is worth noting that AECL offers a Tritium Safe-Handling Course to national and international participants, the course is a mixture of classroom sessions and hands-on practical exercises. The expertise and facilities available at AECL is ready to address technological needs of nuclear fusion and next-generation nuclear fission reactors related to tritium handling and related issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applications Using the Advanced Simulation Capability for Environmental Management Tool-set - 16335

The Office of Soil and Groundwater of the U.S. Department of Energy (DOE) Office of Environmental Management (EM) developed the Advanced Simulation Capability for Environmental Management (ASCEM). The ASCEM tool-sets can be used for making informed choices in uncertain and complex environments, where cost-benefits of environmental impacts and human health need to be considered. The deployments and demonstrations show how ASCEM provides a unified framework that facilitates efficient modeling and analyses to address costs and benefits of engineering and remediation decisions: - Evaluation of engineered remediation and monitoring strategies at the Savannah River Site (SRS) F-Area in collaboration with the Office of Soil and Groundwater Remediation, Attenuation-Based Remedies in the Subsurface Applied Field Research Initiative; - Assessment of performance assessment issues and waste tank closure at SRS; - Evaluation of alternative conceptual models for the deep vadose zone at the Hanford Site, supporting waste tank closure. The ASCEM tool-sets enable computationally efficient representations of the complex subsurface systems, including fractured and faulted volcanic and carbonate aquifers, a very deep water table, and multiple contaminant sources. The applications demonstrate that deployment of the ASCEM tool-sets provides an opportunity to reduce conservatisms in modeling assessments and allows detailed investigation of alternative conceptual models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of High Performance Computing on the Detailed Simulation of Subsurface Flow and Contaminant Transport Using eSTOMP - 16341

The ability to model subsurface processes at the field-scale is essential to site closure and remedial action decisions. Field-scale models often require high-performance computing to meet the computational demands associated with complex systems, model calibration, and uncertainty quantification. eSTOMP, a parallel version of STOMP, is an analytical tool that meets the need for investigating coupled processes in the subsurface involving regional multi-fluid flow and biogeochemistry. The scalability of eSTOMP makes it ideal for simulating contaminant and geochemical reactive transport when long run times result from execution of a serial code. To demonstrate the impact of high-performance computation on subsurface analyses, the application of eSTOMP is presented for two sites. The first site involves uranium surface complexation within a highly dynamic, variably saturated flow field. The use of this model in conjunction with continued field monitoring is expected to provide a rigorous basis for developing operational strategies for field remediation and for defining defensible remediation endpoints. The second site involves the long-term dissolution of low-level radioactive glass emplaced within a near-surface repository. The waste form release rate is evaluated by modeling the basic physical and chemical processes that are known to control the waste form dissolution behavior, including pH and composition of the fluid contacting the glass. Simulations demonstrate that glass dissolution rates vary both in time and as a function of position within the disposal system, and that a 'leach rate' or radionuclide release rate parameter can only be estimated after identifying these impacts in a dynamic system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The suitability of large area drift chambers as the technology choice for the Cosmic Ray Inspection and Passive Tomography (CRIPT) project

The CRIPT project brings together several Canadian institutions, concerned with the detection of Special Nuclear Materials (SNM), addressing a requirement at ports-of-entry for detection of SNM in the many thousands of containers that flow into and out of Canada every day, while at the same time providing a way of monitoring the contents of nuclear waste storage containers, for waste management and non-proliferation reasons. The scale of these applications is large - typically tens of cubic metres, requiring detectors that can cover a large area at a minimum cost. The CRIPT project considered drift chambers adapted from high energy physics experience, as one of its technology choices. We report here on the performance of a full scale prototype, which covers an area of 2.4 m x 1.2 m with only 6 readout channels, and provides a 2D data point with accuracies (in x and z) of around 2 mm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Range and modulation dependencies for proton beam dose per monitor unit calculations

Calculations of dose per monitor unit (D/MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and electron therapy, the D/MU depends on several factors. This study focused on obtaining range and modulation dependence factors used in D/MU calculations for the double scattered proton beam line at the Midwest Proton Radiotherapy Institute. Three dependencies on range and one dependency on modulation were found. A carefully selected set of measurements was performed to discern these individual dependencies. Dependencies on range were due to: (1) the stopping power of the protons passing through the monitor chamber; (2) the reduction of proton fluence due to nuclear interactions within the patient; and (3) the variation of proton fluence passing through the monitor chamber due to different source-to-axis distances (SADs) for different beam ranges. Different SADs are produced by reconfigurations of beamline elements to provide different field sizes and ranges. The SAD effect on the D/MU varies smoothly as the beam range is varied, except at the beam range for which the first scatterers are exchanged and relocated to accommodate low and high beam ranges. A geometry factor was devised to model the SAD variation effect on the D/MU. The measured D/MU variation as a function of range can be predicted within 1% using the three modeled dependencies on range. Investigation of modulated beams showed that an analytical formula can predict the D/MU dependency as a function of modulation to within 1.5%. Special attention must be applied when measuring the D/MU dependence on modulation to avoid interplay between range and SAD effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Fermi Gamma-ray Burst Monitor Instrument

The Fermi Gamma-ray Space Telescope launched on June 11, 2008 carries two experiments onboard--the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM). The primary mission of the GBM instrument is to support the LAT in observing {gamma}-ray bursts (GRBs) by providing low-energy measurements with high temporal and spectral resolution as well as rapid burst locations over a large field-of-view ({>=}8 sr). The GBM will complement the LAT measurements by observing GRBs in the energy range 8 keV to 40 MeV, the region of the spectral turnover in most GRBs. The GBM detector signals are processed by the onboard digital processing unit (DPU). We describe some of the hardware features of the DPU and its expected limitations during intense triggers.

79 ASTRONOMY AND ASTROPHYSICS↗

FLARE-LIKE VARIABILITY OF THE Mg II {lambda}2800 EMISSION LINE IN THE {gamma}-RAY BLAZAR 3C 454.3

We report the detection of a statistically significant flare-like event in the Mg II {lambda}2800 emission line of 3C 454.3 during the outburst of autumn 2010. The highest levels of emission line flux recorded over the monitoring period (2008-2011) coincide with a superluminal jet component traversing through the radio core. This finding crucially links the broad emission line fluctuations to the non-thermal continuum emission produced by relativistically moving material in the jet and hence to the presence of broad-line region clouds surrounding the radio core. If the radio core were located at several parsecs from the central black hole, then our results would suggest the presence of broad-line region material outside the inner parsec where the canonical broad-line region is envisaged to be located. We briefly discuss the implications of broad emission line material ionized by non-thermal continuum in the context of virial black hole mass estimates and gamma-ray production mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

New High-Throughput Measurement Systems for Radioactive Wastes Segregation and Free Release - 16166

The European Metrology Research Program (EMRP) is a coordinated research-and-development program that pursues the closer integration of national research programs. The EMRP Metrology for Decommissioning Nuclear Facilities 'MetroDecom' Joint Research Project ENV54 (JRP ENV54), a 36-month project started in September 2014, delivers research products addressing all aspects of the decommissioning process. This includes the characterization of waste materials present on the decommissioning site, pre-selection prior to free release or repository acceptance measurement, free-release measurement, the measurement of waste packages thermal power prior to the repository storage, and the monitoring of stored wastes and repositories in the very long term. This paper describes the track record of two JRP ENV54 working packages, which address the measurement facilities for pre-selection of waste materials prior to measurement for repository acceptance or possible free release (segregation measurement system); and free release (free release measurement system), based on a single standardized concept characterized by unique, patented lead-free shielding. The key objective is to improve the throughput, accuracy, reliability, modularity and mobility of segregation and free-release measurement. This will result in more reliable decision-making with regard to the safe release and disposal of radioactive wastes into the environment and, resulting in positive economic outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Whole-breast irradiation: a subgroup analysis of criteria to stratify for prone position treatment

To select among breast cancer patients and according to breast volume size those who may benefit from 3D conformal radiotherapy after conservative surgery applied with prone-position technique. Thirty-eight patients with early-stage breast cancer were grouped according to the target volume (TV) measured in the supine position: small ({<=}400 mL), medium (400-700 mL), and large ({>=}700 ml). An ad-hoc designed and built device was used for prone set-up to displace the contralateral breast away from the tangential field borders. All patients underwent treatment planning computed tomography in both the supine and prone positions. Dosimetric data to explore dose distribution and volume of normal tissue irradiated were calculated for each patient in both positions. Homogeneity index, hot spot areas, the maximum dose, and the lung constraints were significantly reduced in the prone position (p < 0.05). The maximum heart distance and the V{sub 5Gy} did not vary consistently in the 2 positions (p = 0.06 and p = 0.7, respectively). The number of necessary monitor units was significantly higher in the supine position (312 vs. 232, p < 0.0001). The subgroups analysis pointed out the advantage in lung sparing in all TV groups (small, medium and large) for all the evaluated dosimetric constraints (central lung distance, maximum lung distance, and V{sub 5Gy}, p < 0.0001). In the small TV group, a dose reduction in nontarget areas of 22% in the prone position was detected (p = 0.056); in the medium and high TV groups, the difference was of about -10% (p = NS). The decrease in hot spot areas in nontarget tissues was 73%, 47%, and 80% for small, medium, and large TVs in the prone position, respectively. Although prone breast radiotherapy is normally proposed in patients with breasts of large dimensions, this study gives evidence of dosimetric benefit in all patient subgroups irrespective of breast volume size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy

Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique. Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc{sub multi-field}) and the standard robust optimized intensity modulated proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds. Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc{sub multi-field} plans. Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRD-06: Creating a Safety Net for a Fully Automated, Script Driven Electronic Medical Record

Purpose: Demonstrate the effectiveness of in-house software in ensuring EMR workflow efficiency and safety. Methods: A web-based dashboard system (WBDS) was developed to monitor clinical workflow in real time using web technology (WAMP) through ODBC (Open Database Connectivity). Within Mosaiq (Elekta Inc), operational workflow is driven and indicated by Quality Check Lists (QCLs), which is triggered by automation software IQ Scripts (Elekta Inc); QCLs rely on user completion to propagate. The WBDS retrieves data directly from the Mosaig SQL database and tracks clinical events in real time. For example, the necessity of a physics initial chart check can be determined by screening all patients on treatment who have received their first fraction and who have not yet had their first chart check. Monitoring similar “real” events with our in-house software creates a safety net as its propagation does not rely on individual users input. Results: The WBDS monitors the following: patient care workflow (initial consult to end of treatment), daily treatment consistency (scheduling, technique, charges), physics chart checks (initial, EOT, weekly), new starts, missing treatments (>3 warning/>5 fractions, action required), and machine overrides. The WBDS can be launched from any web browser which allows the end user complete transparency and timely information. Since the creation of the dashboards, workflow interruptions due to accidental deletion or completion of QCLs were eliminated. Additionally, all physics chart checks were completed timely. Prompt notifications of treatment record inconsistency and machine overrides have decreased the amount of time between occurrence and execution of corrective action. Conclusion: Our clinical workflow relies primarily on QCLs and IQ Scripts; however, this functionality is not the panacea of safety and efficiency. The WBDS creates a more thorough system of checks to provide a safer and near error-less working environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Interactive Reporting of Groundwater Monitoring and Remediation Progress at the Hanford Site, Washington - 16485

DOE annually publishes a groundwater monitoring report and separate groundwater remediation summary reports to comply with reporting and regulatory requirements for the Hanford Site, located in southeastern Washington State. The reports describe year-over-year groundwater monitoring and remediation progress. The annual groundwater monitoring report provides a summary of groundwater monitoring for chemical and radioactive liquid waste releases to the soil that contaminated groundwater from past operations at the site. Content initially consisted of paper reports with static electronic copies available online. Based on an initiative from DOE to provide additional transparency of data and data interpretations presented in the reports, companion interactive versions of the reports were deployed online starting in 2012. The online version provides readers with map-based tools and links to supporting documents and reference materials; individual users can read the reports at their own personal level of expertise and interactively explore groundwater contaminant plume evolution, analytical data, site geology, and remediation system performance. An online user's guide and tutorials for each tool are also provided to assist the user with the overall application and individual tools. The online reports are available at: http://www.hanford.gov/page.cfm/SoilGroundwaterAnnualReports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microbial Influence on Iodine Speciation at the 200 West Hanford Site - 16549

A waste product from nuclear fission, the radioisotope iodine-129 ({sup 129}I) is of environmental concern due to its long half-life (∼16 million years), mobility, and hazardous potential to humans through bioaccumulation in the thyroid gland. The Hanford Site in Richland, Washington, contains two separate {sup 129}I contaminant plumes over 1,500 acres with concentrations of ∼3.5 pCi/L in groundwater samples, exceeding the federal drinking water standard of <1 pCi/L. Consequently, understanding the mechanisms and contributors to iodine speciation is important in order to develop appropriate remediation strategies for iodine in non-aqueous environments such as the vadose zone, the subsurface environment located directly above groundwater. A lack of current remedial techniques is due to the complexity of microbial influence and presence of dissolved organics that impact the transport and speciation of {sup 129}I. Although, iodide (I{sup -}) is thermodynamically favored in the geological support material, based on current pH and Eh ranges at the Hanford Site, groundwater sampling of monitoring wells within the 200 West Area have found the dominant species to be iodate (IO{sub 3}{sup -}) (70.6%) while organo-iodine (25.8%) and iodide (3.6%) were found in far lower quantities. Enrichments of Lower Ringgold sediment from the 200 West Hanford site allowed the isolation of microbial species metabolically involved in the speciation of iodine. Through a series of batch studies and spectrophotometric assays, isolates were found to couple nitrate (NO{sub 3}) reduction with iodate (IO{sub 3}), where iodate reduction was not observed in the absence of nitrate. Additionally, isolates able to oxidize iodide were also identified. Currently, analytical techniques are being developed to further understand the kinetics and enzymatic activity for both of these redox reactions. Ongoing research involves these isolates and their influence on iodine speciation in the presence of organics such as humic acid or lignocellulose. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the Sensitivity of the Antineutrino Probe for Reactor Core Monitoring

This paper presents a feasibility study of the use of the detection of reactor-antineutrinos (ν{sup ¯}{sub e}) for non proliferation purpose. To proceed, we have started to study different reactor designs with our simulation tools. We use a package called MCNP Utility for Reactor Evolution (MURE), initially developed by CNRS/IN2P3 labs to study Generation IV reactors. The MURE package has been coupled to fission product beta decay nuclear databases for studying reactor antineutrino emission. This method is the only one able to predict the antineutrino emission from future reactor cores, which don't use the thermal fission of {sup 235}U, {sup 239}Pu and {sup 241}Pu. It is also the only way to include off-equilibrium effects, due to neutron captures and time evolution of the fission product concentrations during a reactor cycle. We will present here the first predictions of antineutrino energy spectra from innovative reactor designs (Generation IV reactors). We will then discuss a summary of our results of non-proliferation scenarios involving the latter reactor designs, taking into account reactor physics constraints.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An open-walled ionization chamber appropriate to tritium monitoring for glovebox

An open-walled ionization chamber is developed to monitor the tritium concentration in gloveboxes in tritium processing systems. Two open walls are used to replace the sealed wall in common ionization chambers, through which the tritium gas can diffuse into the chamber without the aid of pumps and pipelines. Some basic properties of the chamber are examined to evaluate its performance. Results turn out that an open-walled chamber of 1 l in volume shows a considerably flat plateau over 700 V for a range of tritium concentration. The chamber also gives a good linear response to gamma fields over 4 decades under a pressure condition of 1 atm. The pressure dependence characteristics show that the ionization current is only sensitive at low pressures. The pressure influence becomes weaker as the pressure increases mainly due to the decrease in the mean free path of {beta} particles produced by tritium decay. The minimum detection limit of the chamber is 3.7x10{sup 5} Bq/m{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Moving Voxel Image Reconstruction (MVIR) Method in the Fixed Site Detection System (FSDS) Prototype

We have developed a dynamic image reconstruction method called MVIR (Moving Voxel Image Reconstruction) for lane detection in multilane portal monitor systems. MVIR was evaluated for use in the Fixed Site Detection System, a prototype three-lane portal monitor system for EZ-pass toll plazas. As a baseline, we compared MVIR with a static image reconstruction method in analyzing the same real and simulated data sets. Performance was judged by the distributions of image intensities for source and no-source vehicles over many trials as a function of source strength. We found that MVIR produced significantly better results in all cases. The performance difference was greatest at low count rates, where source/no-source distributions were well separated with the MVIR method, allowing reliable source vehicle identification with a low probability of false positive identifications. Static reconstruction of the same data produced overlapping distributions that made source vehicle identification unreliable. The performance of the static method was acceptable at high count rates. Both algorithms reliably identified two strong sources passing through at nearly the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel approach to criticality accident detection for a legacy facility

For operations on the Sellafield site involving fissile material a Criticality Accident Alarm System (CAAS) has traditionally been installed unless an omission case can be made. An omission case would examine if, in the absence of all controls, a criticality could reasonably be expected or whether the potential dose to an operator would remain below a maximum acceptable dose. It is a UK legal requirement for adequate emergency arrangements to be in place for hazards on a nuclear licensed site. For facilities where criticality is credible there is a regulatory expectation that a -Criticality Warning System- should be in place. A -Criticality Warning System- is not necessarily a full CAAS and alternative means of criticality detection may be part of an adequate emergency plan. The Sellafield site has a Magnox fuel reprocessing facility which has been operated since the 1960's. Evaporation of the Medium Active (MA) liquid waste from this process is undertaken in an associated building. Following extensive review of the plant and process a number of maloperations which can route fissile material to the MA evaporator were identified. Adequate controls to prevent these scenarios were shown to be in place. In the unlikely event of a failure of controls leading to sustained loss of fissile material a criticality incident may occur and hence an emergency plan was determined to be necessary. The novel emergency arrangements which were developed utilized the existing gamma monitor network located across multiple building floors. These gamma monitors are present for radiological safety. This emergency arrangement would require rapid interpretation of the gamma alarms by an operator and the manual triggering of a criticality evacuation alarm. The gamma monitors were demonstrated to be able to detect the minimum incident of concern (10{sup 15} fissions) as well as being able to alarm during the ramp up in power of a large criticality incident (10{sup 18} fissions). It was shown that a criticality accident could readily be distinguished from a radiological event (e.g. loss of containment). To support this work, criticality excursion analysis was used to examine the likely characteristics of a criticality in the MA evaporator. This novel arrangement was justified due to a number of factors including: the limited remaining operational lifetime of this facility (<5 years), the low frequency of maloperation coupled with a failure of controls and the crucial risk reduction provided by the continued reprocessing of Magnox fuel. Furthermore, the time and cost involved with design and installation of a standard CAAS would be substantially greater than a plan based upon existing instrumentation. These arguments were accepted by the UK regulator the Office for Nuclear Regulation (ONR). (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗