Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Self-heterodyne detection of backscattered radiation in single-mode CO{sub 2} lasers

Self-heterodyning in dc-discharge-pumped single-mode CO{sub 2} lasers is analysed theoretically and studied experimentally under strong and weak feedback conditions. Relations for the autodyne gain and modulation depth due to the effect of backscattered radiation with a Doppler-shifted frequency are obtained. Nonlinear distortions of the autodyne signal caused by a strong laser - target feedback are studied. It is shown that the autodyne detection of backscattered radiation in CO{sub 2} lasers can be considered linear even in the case of strong laser beam distortions (nonlinear distortions below 5%). (control of laser radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Dosimetric Factors on Occurrence and Volume of Temporal Lobe Necrosis Following Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma: A Case-Control Study

Purpose: To determine dosimetric risk factors for the occurrence of temporal lobe necrosis (TLN) among nasopharyngeal carcinoma (NPC) patients treated with intensity modulated radiation therapy (IMRT) and to investigate the impact of dose-volume histogram (DVH) parameters on the volume of TLN lesions (V-N). Methods and Materials: Forty-three NPC patients who had developed TLN following IMRT and 43 control subjects free of TLN were retrospectively assessed. DVH parameters included maximum dose (Dmax), minimum dose (Dmin), mean dose (Dmean), absolute volumes receiving specific dose (Vds) from 20 to 76 Gy (V20-V76), and doses covering certain volumes (Dvs) from 0.25 to 6.0 cm{sup 3} (D0.25-D6.0). V-Ns were quantified with axial magnetic resonance images. Results: DVH parameters were ubiquitously higher in temporal lobes with necrosis than in healthy temporal lobes. Increased Vds and Dvs were significantly associated with higher risk of TLN occurrence (P<.05). In particular, Vds at a dose of ≥70 Gy were found with the highest odds ratios. A common increasing trend was detected between V-N and DVH parameters through trend tests (P for trend of <.05). Linear regression analysis showed that V45 had the strongest predictive power for V-N (adjusted R{sup 2} = 0.305, P<.0001). V45 of <15.1 cm{sup 3} was relatively safe as the dose constraint for preventing large TLN lesions with V-N of >5 cm{sup 3}. Conclusions: Dosimetric parameters are significantly associated with TLN occurrence and the extent of temporal lobe injury. To better manage TLN, it would be important to avoid both focal high dose and moderate dose delivered to a large area in TLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of the Pro-Apoptotic TRAIL-Receptor Antibody Mapatumumab With Ionizing Radiation Strongly Increases Long-Term Tumor Control Under Ambient and Hypoxic Conditions

Purpose: Mapatumumab, an agonistic tumor necrosis factor-related apoptosis inducing ligand-receptor antibody, exerts highly synergistic apoptotic effects in vitro and in short-term growth delay assays when combined with irradiation. Because it remained unclear in how far these effects influence local tumor control, long-term experiments using a colorectal xenograft model were undertaken. Material and Methods: Experiments were performed with irradiation (5 x 3 Gy, d1-5) and mapatumumab (10 mg/kg) in Colo205-xenograft-bearing NMRI (nu/nu) nude mice. Graded top up doses were delivered on the tumor-bearing hind leg under ambient and hypoxic conditions; follow-up was 270 days. Growth delay and local tumor control were end points of the study. Statistical analysis of the experiments included calculation of tumor regrowth and local tumor control. Results: After combined treatment, a pronounced tumor regrowth-delay was observed when compared with irradiation alone. Long-term experiments revealed a highly significant increase in local tumor control for ambient (p = 0.00076) and hypoxic treatment (p = 0.000069). Conclusions: The present data demonstrate for the first time that combination of a pro-apoptotic antibody with irradiation results in evidently reduced tumor regrowth times and subsequently highly increased local tumor control under normoxic and hypoxic conditions in a xenograft mouse model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compression of femtosecond pulses with a Gaussian temporal and spatial intensity distribution

The possibility of using the cubic self-action effect of intense radiation for the additional time compression of Gaussian beams with a quasi-uniform cross section is investigated. The ability to recompress 30-fs Gaussian pulses down to 14 fs (16 fs) with the heterogeneity of less than 1.5 fs (2 fs) on the spatial scale, which corresponds to the energy level 63% (86%) of the beam, is theoretically demonstrated at the B-integral of ∼3. (control of laser radiation parameters)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Cylindrical Antenna With Partly Adaptive Phased-Array Feed

A proposed design for a phased-array fed cylindrical-reflector microwave antenna would enable enhancement of the radiation pattern through partially adaptive amplitude and phase control of its edge radiating feed elements. Antennas based on this design concept would be attractive for use in radar (especially synthetic-aperture radar) and other systems that could exploit electronic directional scanning and in which there are requirements for specially shaped radiation patterns, including ones with low side lobes. One notable advantage of this design concept is that the transmitter/ receiver modules feeding all the elements except the edge ones could be identical and, as a result, the antenna would cost less than in the cases of prior design concepts in which these elements may not be identical.

Hussein, Ziad↗

Postmastectomy Hypofractionated and Accelerated Radiation Therapy With (and Without) Subcutaneous Amifostine Cytoprotection

Purpose: Postmastectomy radiation therapy (PMRT) provides major local control and survival benefits. More aggressive radiation therapy schemes may, however, be necessary in specific subgroups, provided they are safely administered. We report the tolerance and efficacy of a highly accelerated and hypofractionated regimen (HypoARC). Methods and Materials: One hundred twelve high-risk patients who had undergone mastectomy received 10 consecutive fractions of 3.5 Gy in 12 days (thoracic wall and axillary/supraclavicular areas). Two consecutive additional fractions of 4 Gy were given to the surgical scar area (electrons 8-10 MeV) and 1 3.5-Gy fraction to the axilla (in cases with extensive nodal involvement). A minimum follow-up of 24 months (median, 44 months) was allowed before analysis. Of 112 patients, 21 (18.7%) refused to receive amifostine, the remaining receiving tolerance-based individualized doses (500-1000 mg/day subcutaneously). Results: By use of a dose individualization algorithm, 68.1%, 11%, and 18.7% of patients received 1000 mg, 750 mg, and 500 mg/day of amifostine. Patchy moist skin desquamation outside and inside the booster fields was noted in 14 of 112 (12.5%) and 26 of 112 (23.2%) patients, respectively. No case of acute pneumonitis was recorded. High amifostine dose offered a significant skin protection. Within a median follow-up time of 44 months, moderate subcutaneous edema outside and within the booster thoracic area was noted in 5 of 112 (4.4%) and 8 of 112 (7.1%) cases, respectively. Intense asymptomatic radiographic findings of in field lung fibrosis were noted in 4 of 112 (3.6%) patients. Amifostine showed a significant protection against lung and soft tissue fibrosis. A 97% projected 5-year local relapse free survival and 84% 5-year disease-specific survival were recorded. Lack of steroid receptor expression, simple human epidermal growth factor 2 positivity, or triple negative phenotype defined higher metastasis rates but had no effect on local control. Conclusions: PMRT with HypoARC showed an excellent early and short-term late toxicity profile, and amifostine further reduced early and late radiation sequelae. Encouraging local control rates are obtained in high-risk subgroups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance characteristics and output power stability of a multichannel fibre laser

The effect of the density and number of spectral channels on the output power stability in a multichannel cw laser has been studied theoretically and experimentally. In our calculations, we used a model in which the interaction between channels due to gain medium saturation was determined by channel frequency spacing-dependent cross-saturation coefficients. The key features of lasing have been analysed and illustrated by the examples of three-, five- and nine-channel lasers. It has been shown that, at a given excess of the pump power over threshold, the channel powers can be equalised by introducing additional losses into the highest power channels. At a sufficiently high channel density, raising the pump power then leads to termination of lasing in the even channels. As the number of channels increases, the laser system retains its stability, but the time needed for the transition to a steady state increases sharply. In our experiments, we used an erbium-doped fibre laser whose design ensured independent control over the powers of up to 40 spectral channels anchored on the telecommunication frequency grid. Our experimental data are in qualitative agreement with the calculation results. In particular, a long-term relative instability less than 3 dB was only observed at a number of channels less than seven and channel frequency spacings above 400 GHz. Instability was shown to increase with an increase in the number and density of channels. (control of laser radiation parameters)

42 ENGINEERING↗

Broadband tunable source of mid-IR laser radiation for photoacoustic spectroscopy

Control over volatile products of metabolic processes in human body in exhaled air is a promising method for noninvasive medical diagnostics. The mid-IR range (2–12 μm) is of great interest for diagnostic applications of the exhaled air spectral analysis. Laser optoacoustic spectroscopy is quite attractive for detecting a large set of gaseous substances; however, high-power sources of tunable radiation are required to increase the method sensitivity. We consider the possibility of using a parametric light generator based on a BaGa{sub 4}Se{sub 7} crystal as a broadband tunable mid-IR laser source for laser optoacoustic spectroscopy. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in the long-pulse steady-state high beta H-mode scenario with active controls of divertor heat and particle fluxes in EAST

Since the last IAEA-Fusion Energy Conference, the Experimental Advanced Superconducting Tokamak (EAST) research program has been, in support of ITER and CFETR, focused on development in terms of the long-pulse steady-state (fully noninductive) high beta H-mode scenario with active controls of the stationary and transient divertor heat and particle fluxes. The operational domain of the steady-state H-mode plasma scenario has been significantly extended with ITER-like tungsten mono-block divertor, plasma control and heating schemes. EAST has achieved several important milestones in the development of high β p H-mode scenario and its key physics and technologies. A 60 s-scale long-pulse steady-state high β p H-mode discharge with the major normalized plasma parameters similar to the designed performance of the CFETR 1GW fusion power operation scenario has been successfully established and sustained by pure RF heating and current drive. Several feedback control schemes have been developed for a sustained detachment with good core confinement. This includes control of the total radiation power, target electron temperature, and particle flux measured using divertor Langmuir probes or a combination of the control of target electron temperature and AXUV radiation near the X point. The detachment feedback control schemes have been integrated with small-ELM regimes and high β p scenario via neon seeding, enabling a core and edge compatible integrated high-beta scenario applicable to long-pulse operations. ELM suppression has been achieved using various methods, including resonant magnetic perturbations and impurity seeding. Full suppression of ELMs by using n=4 RMPs has been demonstrated for ITER for the first time in low input torque plasmas in EAST. Finally, EAST has been operated with helium to support the ITER research requirements for the first time. For a long-pulse, high bootstrap current fraction operation, a new lower tungsten divertor with active water-cooling has been installed, along with improvements in the heating and current drive capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of load-following capacity based on the flame radiation intensity signal in a power plant

The capability to perform fast load changes has been an important issue due to the increasing commercialization of the power market. In the traditional boiler control system, the feedback signals come from the variations of the steam pressure and the steam flow, which leads to a large time delay. Therefore, a new method for the boiler control system based on radiation intensity for improving the load-following capacity of a coal-fired power plant has been developed in this paper. The system is implemented by adding the radiation intensity of the flame to the existing boiler control system as a complement. The radiation intensity obtained by the sensor can directly reflect the input heat in the boiler, with a faster response and higher sensitivity. Field tests on a 300 MW coal-fired power plant reveal that the improved boiler control system increases the load-following capacity. At the same time, the steam pressure variations are smaller as compared with those of the existing control system. 14 refs., 19 figs., 1 tab.

20 FOSSIL-FUELED POWER PLANTS↗

Radiation Induced Degradation of the White Thermal Control Paints Z-93 and Z-93P

This paper details a comparison analysis of the zinc oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 years in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.↗

Automatic Range Changer For SWR Meter

Commercial unit modified for antenna-pattern measurements. Addition of automatic range-changing circuit converts Hewlett-Packard 415E standing-wave-ratio (SWR) meter into radio-frequency detector suitable for computer-controlled measurements of radiation patterns of antennas. Modification gives SWR meter effective dynamic range of at least 40 dB. Includes two digital lines communicating one of four range settings to controlling computer and one digital line to inhibit transfer of data when range being changed. Ideal instrument for use in applications involving computer-controlled monitoring of power when large changes in signal level expected.

Dengler, Robert J.↗

Age Disparity in Palliative Radiation Therapy Among Patients With Advanced Cancer

Purpose/Objective: Palliative radiation therapy represents an important treatment option among patients with advanced cancer, although research shows decreased use among older patients. This study evaluated age-related patterns of palliative radiation use among an elderly Medicare population. Methods and Materials: We identified 63,221 patients with metastatic lung, breast, prostate, or colorectal cancer diagnosed between 2000 and 2007 from the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked database. Receipt of palliative radiation therapy was extracted from Medicare claims. Multivariate Poisson regression analysis determined residual age-related disparity in the receipt of palliative radiation therapy after controlling for confounding covariates including age-related differences in patient and demographic covariates, length of life, and patient preferences for aggressive cancer therapy. Results: The use of radiation decreased steadily with increasing patient age. Forty-two percent of patients aged 66 to 69 received palliative radiation therapy. Rates of palliative radiation decreased to 38%, 32%, 24%, and 14% among patients aged 70 to 74, 75 to 79, 80 to 84, and over 85, respectively. Multivariate analysis found that confounding covariates attenuated these findings, although the decreased relative rate of palliative radiation therapy among the elderly remained clinically and statistically significant. On multivariate analysis, compared to patients 66 to 69 years old, those aged 70 to 74, 75 to 79, 80 to 84, and over 85 had a 7%, 15%, 25%, and 44% decreased rate of receiving palliative radiation, respectively (all P<.0001). Conclusions: Age disparity with palliative radiation therapy exists among older cancer patients. Further research should strive to identify barriers to palliative radiation among the elderly, and extra effort should be made to give older patients the opportunity to receive this quality of life-enhancing treatment at the end of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Control Probability Modeling and Systematic Review of the Literature of Stereotactic Body Radiation Therapy for Prostate Cancer

Dose escalation improves localized prostate cancer disease control, and moderately hypofractionated external beam radiation is noninferior to conventional fractionation. The evolving treatment approach of ultrahypofractionation with stereotactic body radiation therapy (SBRT) allows possible further biological dose escalation (biologically equivalent dose [BED]) and shortened treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating Cloud Processes in the Community Atmosphere Model, Version 5.

This paper provides a description on the parameterizations of global cloud system in CAM5. Compared to the previous versions, CAM5 cloud parameterization has the following unique characteristics: (1) a transparent cloud macrophysical structure that has horizontally non-overlapped deep cumulus, shallow cumulus and stratus in each grid layer, each of which has own cloud fraction, mass and number concentrations of cloud liquid droplets and ice crystals, (2) stratus-radiation-turbulence interaction that allows CAM5 to simulate marine stratocumulus solely from grid-mean RH without relying on the stability-based empirical empty stratus, (3) prognostic treatment of the number concentrations of stratus liquid droplets and ice crystals with activated aerosols and detrained in-cumulus condensates as the main sources and evaporation-sedimentation-precipitation of stratus condensate as the main sinks, and (4) radiatively active cumulus. By imposing consistency between diagnosed stratus fraction and prognosed stratus condensate, CAM5 is free from empty or highly-dense stratus at the end of stratus macrophysics. CAM5 also prognoses mass and number concentrations of various aerosol species. Thanks to the aerosol activation and the parameterizations of the radiation and stratiform precipitation production as a function of the droplet size, CAM5 simulates various aerosol indirect effects associated with stratus as well as direct effects, i.e., aerosol controls both the radiative and hydrological budgets. Detailed analysis of various simulations revealed that CAM5 is much better than CAM3/4 in the global performance as well as the physical formulation. However, several problems were also identifed, which can be attributed to inappropriate regional tuning, inconsistency between various physics parameterizations, and incomplete model physics. Continuous efforts are going on to further improve CAM5.

CAM5↗