Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Results Of Initial Analyses Of The Salt (Macro) Batch 9 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics. Further results on the chemistry and other tests will be issued in the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of initial analyses of the salt (macro) batch 9 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further results on the chemistry and other tests will be issued in the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of initial analyses of the salt (macro) batch 10 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 10 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 10 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RhizoGrid Indexed Sorghum Rhizosphere Multi-Omics

PerCon SFA project data dentification of spatially resolved biomarkers of drought in Sorghum bicolor rhizosphere molecular-microbe interactions using a novel root cartography "RhizoGrid" system for sampling plants under drought and control conditions across 10 equally sized root zone environments (4 quadrants each). Each quadrant was sampled and processed for 16S amplicon, metabolomics, and X-ray computed tomography (XCT). Data download includes experimental metadata and results files for 16S rRNA sequence analysis of microbial community assembly (processed data files), liquid chromatography mass spectrometry (LC-MS) metabolomics analysis of microbial community root exudates (processed data files), X-ray computed tomography (XCT) spatial gradient analysis (raw and processed data files) of microbial community composition, and related computational modeling outputs.

59 BASIC BIOLOGICAL SCIENCES↗

NREL's Capabilities in Analytical Sciences Supporting Research and Development (R&D)

NREL researchers perform biomass characterization in dedicated laboratories working with over $5 million in state-of-the-art analytical equipment. A dedicated team of highly skilled analytical chemists have over 100 cumulative years of experience in characterization. They have three specialized laboratories with dedicated sample processing and advanced analytical equipment. Core capabilities include biomass and biochemical characterization and quantification, publicly available laboratory analytical procedures (LAPs), and near-infrared rapid analysis.

analysis↗

Estimating Drizzle Parameters by Aircraft Sampling

In-cloud supersaturation is calculated from aircraft derived measurements of the in-cloud vertical gradient of liquid water content, vertical velocity, the pt and 3 rd cloud droplet radius moments and a parameter related to the heat and mass transport during condensation and evaporation of cloud droplets. The aircraft data where taken during the VOCALS 2008 study in marine stratocumulus clouds off the coast of Chile. Approximately 16000 discrete samples, 2.5 meter in length, were used in the present analysis of in-cloud supersaturation and its variability, both of which are indicative of turbulent processes within the cloud and their significant impact on drizzle formation. Two additional drizzle parameters, the eddy persistence time and the variance of fluctuations in in-cloud droplet growth rate were also estimated from this data set. These results will help to constrain parameterizations of underlying turbulent microphysical processes of clouds and thereby advance the future development of warm cloud and precipitation models for climate simulation.

54 ENVIRONMENTAL SCIENCES↗

Distillation-based Droplet Modeling of Non-Ideal Oxygenated Gasoline Blends: Investigating the Role of Droplet Evaporation on PM Emissions

In some studies, a relationship has been observed between increasing ethanol content in gasoline and increased particulate matter (PM) emissions from vehicles equipped with spark ignition engines. The fundamental cause of the PM increase seen for moderate ethanol concentrations is not well understood. Ethanol features a greater heat of vaporization (HOV) than gasoline and also influences vaporization by altering the liquid and vapor composition throughout the distillation process. A droplet vaporization model was developed to explore ethanol's effect on the evaporation of aromatic compounds known to be PM precursors. The evolving droplet composition is modeled as a distillation process, with non-ideal interactions between oxygenates and hydrocarbons accounted for using UNIFAC group contribution theory. Predicted composition and distillation curves were validated by experiments. Detailed hydrocarbon analysis was applied to fuel samples and to distillate fractions, and used as input for the initial droplet composition. With composition calculated throughout the distillation, the changing HOV and other physical properties can be found using reference data. The droplet can thus be modeled in terms of energy transfer, which in turn provides the transient mass transfer, droplet temperature, and droplet diameter. Model predictions suggest that non-ideal vapor-liquid equilibrium along with an increase in HOV can alter the droplet composition evolution. Results predict that the presence of ethanol causes enrichment of the higher boiling fractions (T90+) in the aromatic components as well as lengthens the droplet lifetime. A simulation of the evaporation process in a transient environment as experienced within an engine cylinder predicts a decrease in mixing time of the heaviest fractions of the fuel prior to spark initiation, possibly explaining observations linking ethanol to PM.

02 PETROLEUM↗

Non-destructive Quantitative Phase Analysis and Microstructural Characterization of Zirconium Coated U-10Mo Fuel Foils via Neutron Diffraction

This report uses neutron diffraction to investigate the crystal phase composition of uranium-molybdenum alloy foils (U-10Mo) for the CONVERT MP-1 Reactor Conversion Project, and determines the effect on alpha-uranium contamination following the deposition of a Zr metal diffusion layer by various methods: plasma spray deposition of Zr powders at LANL and hot co-rolling with Zr foils at BWXT. In summary, there is minimal decomposition of the gamma phase U-10Mo foil to alpha phase contamination following both plasma spraying and hot co-rolling. The average unit cell volume, i.e. lattice spacing, of the Zr layer can be mathematically extracted from the diffraction data; co-rolled Zr matches well with literature values of bulk Zr, while plasma sprayed Zr shows a slight increase in the lattice spacing, indicative of interstitial oxygen in the lattice. Neutron diffraction is a beneficial alternative to conventional methods of phase composition, i.e. x ray diffraction (XRD) and destructive metallography. XRD has minimal penetration depth in high atomic number materials, particularly uranium, and can only probe the first few microns of the fuel plate; neutrons pass completely through the foil, allowing for bulk analysis of the foil composition and no issues with addition of cladding layers, as in the final, aluminum-clad reactor fuel plates. Destructive metallography requires skilled technicians, cutting of the foil into small sections, hazardous etching conditions, long polishing and microscopy times, etc.; the neutron diffraction system has an automated sample loader and can fit larger foils, so there is minimal analysis preparation; the total spectrum acquisition time is ~ 1 hour per sample. The neutron diffraction results are limited by spectra refinement/calculation times and the availability of the neutron beam source. In the case of LANSCE at Los Alamos, the beam operates ~50% of the year. Following the lessons learned from these preliminary results, optimizations to the process and analysis can be made, and neutron diffraction can become a viable and efficient technique for gamma/alpha phase composition determination for nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Machine Learning-Based Vulnerability Analysis for Cascading Failures of Integrated Power-Gas Systems

This article proposes a cascading failure simulation (CFS) method and a hybrid machine learning method for vulnerability analysis of integrated power-gas systems (IPGSs). The CFS method is designed to study the propagating process of cascading failures between the two systems, generating data for machine learning with initial states randomly sampled. The proposed method considers generator and gas well ramping, transmission line and gas pipeline tripping, island issue handling and load shedding strategies. Then, a hybrid machine learning model with a combined random forest (RF) classification and regression algorithms is proposed to investigate the impact of random initial states on the vulnerability metrics of IPGSs. Extensive case studies are carried out on three test IPGSs to verify the proposed models and algorithms. Simulation results show that the proposed models and algorithms can achieve high accuracy for the vulnerability analysis of IPGSs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Formation and Decomposition Process of the Filled Skutterudite Sm{sub y}(Fe{sub x}Ni{sub 1−x}){sub 4}Sb{sub 12} (0.40 ≤ x ≤ 1) as Revealed by Differential Thermal Analysis

Filled skutterudites are among the most promising thermoelectric materials, and the obtainment of monophasic samples is crucial for the study of their transport properties. In this work, a differential thermal analysis study was performed on samples belonging to the Sm{sub y}(Fe{sub x}Ni{sub 1-x}){sub 4}Sb{sub 12} system with the aim to determine the most proper annealing temperature to possibly obtain skutterudite monophasic samples, and to study the effect of Sm addition on the thermodynamics of the Fe-Ni-Sb system. Samples were prepared through the traditional procedure consisting in melting–quenching–annealing the starting elements. DTA analyses were carried out on annealed samples, and results were interpreted using the Fe{sub 25}Sb{sub 75}-Ni{sub 25}Sb{sub 75} pseudobinary phase diagram taken from the literature as a starting point. They reveal that 870 K is the best annealing temperature, being the formation of a liquid phase just above this point; moreover, the Sm introduction results in widening the one-phase skutterudite stability region toward both higher temperatures and higher Fe concentrations compared with the Sm-free system.

36 MATERIALS SCIENCE↗

Milestone report - M4FT-15OR03120210 - Multi-lab Analytical Plan for Analysis of Legacy 85 Kr Samples

Legacy samples composed of 85 Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened and the inner package removed and placed in a radiation hood. The individual capsules were double bagged as they were removed from the inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 was previously opened. The end of this capsule appears to have been cut off and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. A conference call was held on February 19, 2015, with participation from ORNL, Idaho National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory Sigma Team members. The nondestructive analysis (NDA) results were discussed, and a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging and spatially resolved mass spectrometry applications in nephrology

The application of spatially resolved mass spectrometry (MS) and MS imaging approaches for studying biomolecular processes in the kidney is rapidly growing. These powerful methods, which enable label-free and multiplexed detection of many molecular classes across omics domains (including metabolites, drugs, proteins and protein post-translational modifications), are beginning to reveal new molecular insights related to kidney health and disease. Further, the complexity of the kidney often necessitates multiple scales of analysis for interrogating biofluids, whole organs, functional tissue units, single cells and subcellular compartments. Various MS methods can generate omics data across these spatial domains and facilitate both basic science and pathological assessment of the kidney. Optimal processes related to sample preparation and handling for different MS applications are rapidly evolving. Emerging technology and methods, improvement of spatial resolution, broader molecular characterization, multimodal and multiomics approaches and the use of machine learning and artificial intelligence approaches promise to make these applications even more valuable in the field of nephology. Overall, spatially resolved MS and MS imaging methods have the potential to fill much of the omics gap in systems biology analysis of the kidney and provide functional outputs that cannot be obtained using genomics and transcriptomic methods.

60 APPLIED LIFE SCIENCES↗

Blackout Diffusion: Generative Diffusion Models in Discrete-State Spaces

Typical generative diffusion models rely on a Gaussian diffusion process for training the backward transformations, which can then be used to generate samples from Gaussian noise. However, real world data often takes place in discrete-state spaces, including many scientific applications. Here, we develop a theoretical formulation for arbitrary discrete-state Markov processes in the forward diffusion process using exact (as opposed to variational) analysis. We relate the theory to the existing continuous-state Gaussian diffusion as well as other approaches to discrete diffusion, and identify the corresponding reverse-time stochastic process and score function in the continuous-time setting, and the reverse-time mapping in the discrete-time setting. As an example of this framework, we introduce “Blackout Diffusion”, which learns to produce samples from an empty image instead of from noise. Numerical experiments on the CIFAR-10, Binarized MNIST, and CelebA datasets confirm the feasibility of our approach. Generalizing from specific (Gaussian) forward processes to discrete-state processes without a variational approximation sheds light on how to interpret diffusion models, which we discuss.

Santos, Javier E.↗

Expression profile analysis of differentially expressed genes in ruptured intracranial aneurysms: In search of biomarkers

Highlights: • Bioinformatics can identify potential biomarkers of ruptured intracranial aneurysm. • BASP1, CD74, CEBPB, ECHDC2, GZMK, HLA-DRB3, KLHL3, SLC2A3 & SOCS3 affect IA rupture. • DEGs are involved in antigen processing and presentation and immune response. • Vascular brain injury affects gene expression in IA tissue. Intracranial aneurysms (IAs) result from the bulging of arterial walls secondary to several factors such as flow, vessel morphology, and genetics. Subarachnoid hemorrhage occurs when such walls rupture, leading to high disability and mortality. Despite numerous investigations pertaining to the relationship between geometric characteristics and IA rupture, only a few have obtained consistent results. This study aimed to further identify the potential genes associated with the pathogenesis of IAs, which may provide novel molecular biomarkers. We downloaded and reanalyzed six datasets, which were divided into four groups. IA walls and blood samples were screened for differentially expressed genes (DEGs); then, functional and pathway enrichment analyses were conducted. In total, 158 common DEGs were identified from Groups 1–3 and 396 genes (187 upregulated and 209 downregulated genes) were differentially expressed in Group 4. The functional analysis revealed that the DEGs were mainly associated with the major histocompatibility complex class II protein complex and antigen processing and presentation. Finally, we identified nine key genes, both in aneurysm tissue samples and blood samples, of which three were mostly associated with the progression and rupture of IAs. Bioinformatics was used to analyze the datasets of the ruptured IAs and identify potential biomarkers, which may provide information for the early detection and treatment of IAs.

60 APPLIED LIFE SCIENCES↗

Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

holding time↗

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗