Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Detect and Avoid and Collision Avoidance Flight Test Results with ACAS Xr

In October 2023, the National Aeronautics and Space Administration (NASA) completed its Integration of Automated Systems flight test series, conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. Approximately half of the flight test was devoted to assessing the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. The ownship was equipped with ACAS Xr and the intruder was equipped with Automatic Dependent Surveillance-Broadcast (ADS-B). The test points were blocked by ACAS Xr configuration, with individual encounters varying the ownship speed (90 knots or 20 knots), the intruder designation (en-route, terminal area, or structured airspace), and method of RA execution (automated or manually executed). Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

FT-01: Autonomous Helicopter Flight Testing Over Long Island Sound Special Session - Hazard Perception and Avoidance Tech Area

This presentation is included as part of a panel reporting on the Integration of Automated Systems (IAS) flight test series. The IAS series concluded in October 2023 and was conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. This portion of the panel presentation focuses on the results of the flight test that assessed the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

Detect and Avoid and Collision Avoidance Flight Test Results with ACAS Xr

In October 2023, the National Aeronautics and Space Administration (NASA) completed its Integration of Automated Systems flight test series, conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. Approximately half of the flight test was devoted to assessing the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. The ownship was equipped with ACAS Xr and the intruder was equipped with Automatic Dependent Surveillance-Broadcast (ADS-B). The test points were blocked by ACAS Xr configuration, with individual encounters varying the ownship speed (90 knots or 20 knots), the intruder designation (en-route, terminal area, or structured airspace), and method of RA execution (automated or manually executed). Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

X-ray color analysis of the spectra of active galactic nuclei

The identification and detection of X-ray absorption and emission features depends on the resolution and the signal-to-noise ratio (S/N) of the observation, the understanding of the instrument response, and the Galactic line-of-sight absorption. Since many of the active galactic nucleus (AGN) data sets are limited in their S/N and full modeling of the physical conditions is rather complicated, we suggest a new analysis method based on 'X-ray colors.' The two sets of X-ray colors, defined for low (ROSAT Position Sensitive Proportional Counter (PSPC)) and medium (Broad Band X-Ray Telescope (BBXRT)) and ASCA Solid-State Imaging Spectrometers (SIS) resolution experiments, are used to separate regions of different physical conditions in a two-dimensional color-color plane. They are similar but superior to previous methods using the X-ray 'hardness ratio' in being able to reveal more of the physical properties of the source. We illustrate the use of such diagrams by studying a number of AGNs suspected of showing absorption features. A sample of 14 AGNs observed by the ROSAT PSPC is presented which includes several objects with suspected 'warm absorbers' along the line-of-sight to the nucleus, several others exhibiting intrinsic continuum variations, and a number of control objects thought to be featureless. Our new observations show, for the first time, the color variation as a function of time for three of the Seyfert 1 sources: NGC 4051, Mrk 335, and Mrk 766. The variations suggest that in two sources we are witnessing real changes in continuum shape, while one (NGC 4051) is consistent with having a warm absorber. Four of the objects observed by BBXRT are reanalyzed using our X-ray colors. Out of these, we discuss in detail the case of NGC 4151 and show that the color-color analysis agrees very well with previous, detailed spectral fitting methods. In particular, we confirm that the observed BBXRT observation of this source is not consistent with the warm absorber explanation and must be interpreted as a combination of a variable hard component and another component. We explain the limitations in measuring low-energy emission features in ASCA SIS observations and present color-color diagrams which can be used as a powerful diagnostic tool in the analysis of data collected by this experiment.

Netzer, Hagai↗

E3SM‐Arctic: Regionally Refined Coupled Model for Advanced Understanding of Arctic Systems Interactions

Earth system models are essential tools for climate projections, but coarse resolutions limit regional accuracy, especially in the Arctic. Regionally refined meshes (RRMs) enhance resolution in key areas while maintaining computational efficiency. This paper provides an overview of the United States (U.S.) Department of Energy's (DOE's) Energy Exascale Earth System Model version 2.1 with an Arctic RRM, hereafter referred to as E3SMv2.1-Arctic, for the atmosphere (25 km), land (25 km), and ocean/ice (10 km) components. We evaluate the atmospheric component and its interactions with land, ocean, and cryosphere by comparing the RRM (E3SM2.1-Arctic) historical simulations (1950–2014) with the uniform low-resolution (LR) counterpart, reanalysis products, and observational data sets. The RRM generally reduces biases in the LR model, improving simulations of Arctic large-scale mean fields, such as precipitation, atmospheric circulation, clouds, atmospheric river frequency, and sea ice thickness. However, it introduces a seasonally dependent surface air temperature bias, reducing the LR cold bias in summer but enhancing the LR warm bias in winter, which contributes to the underestimated winter sea ice area and volume. Radiative feedback analysis shows similar climate feedback strengths in both model configurations, with the RRM exhibiting a more positive surface albedo feedback and contributing to a stronger surface warming than LR. These findings underscore the importance of high-resolution modeling for advancing our understanding of Arctic climate changes and their broader global impacts, although some persistent biases appear to be independent of model resolution at 10–100 km scales.

Energy Exascale Earth System Model (E3SM)↗

Mapped Landmark Algorithm for Precision Landing

A report discusses a computer vision algorithm for position estimation to enable precision landing during planetary descent. The Descent Image Motion Estimation System for the Mars Exploration Rovers has been used as a starting point for creating code for precision, terrain-relative navigation during planetary landing. The algorithm is designed to be general because it handles images taken at different scales and resolutions relative to the map, and can produce mapped landmark matches for any planetary terrain of sufficient texture. These matches provide a measurement of horizontal position relative to a known landing site specified on the surface map. Multiple mapped landmarks generated per image allow for automatic detection and elimination of bad matches. Attitude and position can be generated from each image; this image-based attitude measurement can be used by the onboard navigation filter to improve the attitude estimate, which will improve the position estimates. The algorithm uses normalized correlation of grayscale images, producing precise, sub-pixel images. The algorithm has been broken into two sub-algorithms: (1) FFT Map Matching (see figure), which matches a single large template by correlation in the frequency domain, and (2) Mapped Landmark Refinement, which matches many small templates by correlation in the spatial domain. Each relies on feature selection, the homography transform, and 3D image correlation. The algorithm is implemented in C++ and is rated at Technology Readiness Level (TRL) 4.

Johnson, Andrew↗

Numerical techniques for large cosmological N-body simulations

Techniques for carrying out large N-body simulations of the gravitational evolution of clustering in the fundamental cube of an infinite periodic universe are described and compared. The accuracy of the forces derived from several commonly used particle mesh schemes is examined, showing how submesh resolution can be achieved by including short-range forces between particles by direct summation techniques. The time integration of the equations of motion is discussed, and the accuracy of the codes for various choices of 'time' variable and time step is tested by considering energy conservation as well as by direct analysis of particle trajectories. Methods for generating initial particle positions and velocities corresponding to a growing mode representation of a specified power spectrum of linear density fluctuations are described. The effects of force resolution are studied and different simulation schemes are compared. An algorithm is implemented for generating initial conditions by varying the number of particles, the initial amplitude of density fluctuations, and the initial peculiar velocity field.

Efstathiou, G.↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

SeaWiFS technical report series. Volume 15: The simulated SesWiFS data set, version 2

This document describes the second version of the simulated SeaWiFS data set. A realistic simulated data set is essential for mission readiness preparations and can potentially assist in all phases of ground support for a future mission. The second version improves on the first version primarily through additional realism and complexity. This version incorporates a representation of virtually every aspect of the flight mission. Thus, it provides a high-fidelity data set for testing several aspects of the ground system, including data acquisition, data processing, data transfers, calibration and validation, quality control, and mission operations. The data set is constructed for a seven-day period, 25-31 March 1994. Specific features of the data set include Global Area coverage (GAC), recorded Local Area Coverage (LAC), and realtime High Resolution Picture Transmission (HRPT) data for the seven-day period. A realistic orbit, which is propagated using a Brouwer-Lyddane model with drag, is used to simulate orbit positions. The simulated data corresponds to the command schedule based on the orbit for this seven-day period. It includes total (at-satellite) radiances not only for ocean, but for land, clouds, and ice. The simulation also utilizes a high-resolution land-sea mask. It includes the April 1993 SeaWiFS spectral responses and sensor saturation responses. The simulation is formatted according to July 1993 onboard data structures, which include corresponding telemetry (instrument and spacecraft) data. The methods are described and some examples of the output are given. The instrument response functions made available in April 1993 have been used to produce the Version 2 simulated data. These response functions will change as part of the sensor improvements initiated in July-August 1993.

Hooker, Stanford B.↗

Resolving the Inner Parsec of the Blazar J1924–2914 with the Event Horizon Telescope

The blazar J1924–2914 is a primary Event Horizon Telescope (EHT) calibrator for the Galactic center’s black hole Sagittarius A*. Here we present the first total and linearly polarized intensity images of this source obtained with the unprecedented 20 μas resolution of the EHT. J1924–2914 is a very compact flat-spectrum radio source with strong optical variability and polarization. In April 2017 the source was observed quasi-simultaneously with the EHT (April 5–11), the Global Millimeter VLBI Array (April 3), and the Very Long Baseline Array (April 28), giving a novel view of the source at four observing frequencies, 230, 86, 8.7, and 2.3 GHz. These observations probe jet properties from the subparsec to 100 pc scales. We combine the multifrequency images of J1924–2914 to study the source morphology. We find that the jet exhibits a characteristic bending, with a gradual clockwise rotation of the jet projected position angle of about 90° between 2.3 and 230 GHz. Linearly polarized intensity images of J1924–2914 with the extremely fine resolution of the EHT provide evidence for ordered toroidal magnetic fields in the blazar compact core.

79 ASTRONOMY AND ASTROPHYSICS↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

High throughput non-dispersive hard X-ray spectrograph with angular resolution for cosmic bursts, transients, and sources

An instrument concept which offers high throughput nondispersive spectroscopy in the 35-150 keV band for measuring line intensities and widths of faint supernovae is described. The design is based on existing xenon filled, two-dimensional, position sensitive, multiwired proportional counters. Effective detector areas of 1000 sq cm are readily achievable, and expansion to 10,000 sq cm per unit is feasible. Either single-unit or array operation to provide all-sky coverage with one arcmin resolution is possible. The instrument could be used to record gamma ray bursts and would have the capability of distinguishing particle events. Observations could also be made of X ray cyclotron lines and the Ti-44 lines expected to issue from a supernova explosion.

Gorenstein, P.↗

Mode Tracker for Mode-Hop-Free Operation of a Laser

A mode-tracking system that includes a mode-controlling subsystem has been incorporated into an external-cavity (EC) quantum cascade laser that operates in a mid-infrared wavelength range. The mode-tracking system makes it possible to perform mode-hop-free wavelength scans, as needed for high-resolution spectroscopy and detection of trace gases. The laser includes a gain chip, a beam-collimating lens, and a diffraction grating. The grating is mounted on a platform, the position of which can be varied to effect independent control of the EC length and the grating angle. The position actuators include a piezoelectric stage for translation control and a motorized stage for coarse rotation control equipped with a piezoelectric actuator for fine rotation control. Together, these actuators enable control of the EC length over a range of about 90 m with a resolution of 0.9 nm, and control of the grating angle over a coarse-tuning range of +/-6.3deg and a fine-tuning range of +/-520 microrad with a resolution of 10 nrad. A mirror mounted on the platform with the grating assures always the same direction of the output laser beam.

Wysocki, Gerard↗

Deriving spatially explicit direct and indirect interaction networks from animal movement data

Abstract Quantifying spatiotemporally explicit interactions within animal populations facilitates the understanding of social structure and its relationship with ecological processes. Data from animal tracking technologies (Global Positioning Systems [“GPS”]) can circumvent longstanding challenges in the estimation of spatiotemporally explicit interactions, but the discrete nature and coarse temporal resolution of data mean that ephemeral interactions that occur between consecutive GPS locations go undetected. Here, we developed a method to quantify individual and spatial patterns of interaction using continuous‐time movement models (CTMMs) fit to GPS tracking data. We first applied CTMMs to infer the full movement trajectories at an arbitrarily fine temporal scale before estimating interactions, thus allowing inference of interactions occurring between observed GPS locations. Our framework then infers indirect interactions—individuals occurring at the same location, but at different times—while allowing the identification of indirect interactions to vary with ecological context based on CTMM outputs. We assessed the performance of our new method using simulations and illustrated its implementation by deriving disease‐relevant interaction networks for two behaviorally differentiated species, wild pigs ( Sus scrofa ) that can host African Swine Fever and mule deer ( Odocoileus hemionus ) that can host chronic wasting disease. Simulations showed that interactions derived from observed GPS data can be substantially underestimated when temporal resolution of movement data exceeds 30‐min intervals. Empirical application suggested that underestimation occurred in both interaction rates and their spatial distributions. CTMM‐Interaction method, which can introduce uncertainties, recovered majority of true interactions. Our method leverages advances in movement ecology to quantify fine‐scale spatiotemporal interactions between individuals from lower temporal resolution GPS data. It can be leveraged to infer dynamic social networks, transmission potential in disease systems, consumer–resource interactions, information sharing, and beyond. The method also sets the stage for future predictive models linking observed spatiotemporal interaction patterns to environmental drivers.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

An Analysis of the Automated Meteorological Profiling System Low Resolution Flight Element

A study was conducted to determine the quality of thermodynamic and wind data measured by or derived from the Low Resolution Flight Element (LRFE) of the Automated Meteorological Profiling System (AMPS). The AMPS LRFE replaced the Meteorological Sounding System (MSS), which was used to provide vertical profiles of thermodynamic and low-resolution wind data in support of spacecraft launch operations at the Cape Canaveral Air Force Station (CCAFS) and NASA Kennedy Space Center (KSC), Florida. Air temperature, relative humidity, and height, which are directly measured by the LRFE, are used to derive air pressure and density. Test flights were conducted where an LRFE sonde and an MSS sonde were attached to the same balloon and the two profiles were compared. MSS data was used as the standard reference data. The objective of the thermodynamic testing was to determine a) if the LRFE met Space Shuttle Program (SSP) accuracy requirements outlined in the Space Shuttle Launch and Landing Program Requirements Document (PRD) and/or, b) if the LRFE met or exceeded MSS data quality. AMPS uses the Global Positioning System (GPS) to determine wind speed and direction. In order to provide a basis for comparison, either an AMPS High Resolution Flight Element (HRFE) or a radar tracked Jimsphere was released simultaneously with each AMPS LRFE at CCAFS. The goal of these tests was to determine if the LRFE wind data met the requirement for low-resolution wind data defined in the Shuttle PRD. Based on the available data, the LRFE is shown to produce more consistent thermodynamic measurements than the MSS. The LRFE is also shown to meet the Shuttle PRD requirements for low resolution wind data.

Leahy, Frank B.↗