Conductive two-dimensional titanium carbide ‘clay’ with high volumetric capacitance
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)
Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. There is thus a need for other systems which can be used for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission inflight reprioritization). We describe and report on a one year effort with as primary goal to provide a recommendation to SERDP for a path forward in the implementation of one or more autonomous unmanned magnetometer rotorcraft platforms. This recommendation (which is provided in chapter 6) is based on the following three elements a) An assessment on the applicability of autonomous rotorcraft magnetometer systems to the current DoD site inventory, and an initial assessment of which type(s) of autonomous unmanned magnetometer rotorcraft platforms (in terms of performance characteristics such as payload, altitude, obstacle avoidance, production rate and flight time) would be most relevant to this inventory (chapter 3); b) An evaluation of the feasibility of assembling such platforms from commercial components (unmanned rotorcraft, control systems and sensors – both magnetometer sensors and supporting sensors). This evaluation included several highly successful field tests (chapter 4 and 5); c) A recommendation of the path forward, which includes a detailed outline of the efforts required in the design, assembly and testing of different modular platforms (chapter 6)
This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps for neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.
Flexible photovoltaics (PV) represents a promising research field with great potential for wearable, portable, and indoor applications. Significant progress has been made in recent years, with flexible emerging PV reporting power conversion efficiency (PCE) over 24%. Yet, there is a need for a unifying protocol to assess PV performance, compare research results, and evaluate the state- of-the-art achievements in flexible PV. In this paper, a consensus protocol is presented for measuring PCE over 1,000 bending cycles under 1% strain. Moreover, several good practice guidelines are proposed including bending procedures, flexibility testing with and without encapsulation, and ambient conditions during testing (e.g., temperature, humidity, illumination). Notably, the importance of uniform application of bending radius and the testing of parallel and perpendicular orientations of bending axis with respect to the direction of the electric current are emphasized. These recommendations aim to promote consistency in device comparison and allow for better reproducibility.
ENRICO is a coupled application developed under the U.S. Department of Energy's Exascale Computing Project (ECP) targeting the modeling of advanced nuclear reactors. It couples radiation transport with heat and fluid simulation, including the high-fidelity, highresolution Monte-Carlo code Shift and the Computational fluid dynamics code NekRS. NekRS is a highly-performant open-source code for simulation of incompressible and low-Mach fluid flow, heat transfer, and combustion with a particular focus on turbulent flows in complex domains. It is based on rapidly convergent high-order spectral element discretizations that feature minimal numerical dissipation and dispersion. State-of-the-art multilevel preconditioners, efficient high-order time-splitting methods, and runtime-adaptive communication strategies are built on a fast OCCA-based kernel library, libParanumal, to provide scalability and portability across the spectrum of current and future high-performance computing platforms. On Frontier, Nek5000/RS has recently achieved an unprecedented milestone in breaching over 1 billion spectral elements and 350 billion degrees of freedom. Shift has demonstrated the capability to transport upwards of 1 billion particles per second in full core nuclear reactor simulations featuring complete temperature-dependent, continuous-energy physics on Frontier. Shift achieved a weak-scaling efficiency of 97.8% on 8192 nodes of Frontier and calculated 6 reactions in 214,896 fuel pin regions below 1% statistical error yielding first-of-a-kind resolution for a Monte Carlo transport application.
Polymer binders are important components of most battery electrodes, ensuring high performance and long-term durability. Increasing demand for lithium-ion batteries in the automotive, stationary power, and portable electronics industries calls for a greener binder to replace poly(vinylidene difluoride) (PVDF). We evaluate the performance of aqueous solution-processed electrodes prepared with a rigid-rod polymer binder, poly(2,2'-disulfonyl-4,4'-benzidine terephthalamide) (PBDT). The polyamide backbone and double-helical configuration of PBDT give rise to its mechanical strength and rigidity, and its functional nature (H-bonding amides and sulfonates) can provide specific binding with electrode particles. LiFePO 4 electrodes prepared with 3 wt% PBDT show mechanical integrity and cycling stability, achieving over 1000 cycles at 4C rate with negligible capacity decay. These electrodes demonstrate comparable rate performance with their PVDF counterparts while eliminating fluorine from the electrode as well as the organic solvents needed for processing. Furthermore, this study reveals that PBDT holds great potential as a binder for advanced sustainable batteries.
State-of-the-Art solid oxide fuel cells (SOFC) are amongst the main candidates for clean energy technology due to their high efficiency, fuel flexibility, low air pollution, and minimal greenhouse gas emission. However, high operational temperature of SOFC is a greater challenge in commercialization these devices for low cost and portable applications. High temperature operation of SOFC degrades its performance with aging, limits the selection of materials for fuel cell components, and increases the fabrication cost. Thus, there have been enormous efforts to improve the properties of existing materials and develop new materials for SOFC components in order to lower the operating temperature of SOFC. Recent advances in thin film technology have also been utilized to develop new materials with improved properties for SOFC. One of the key components in SOFC is the electrolyte and several research groups are working on developing new electrolyte materials. In this chapter, we will discuss the recent advances in thin film SOFC electrolytes. This extensive discussion includes the evolution of doped ceria, doped zirconia, and multilayer hetero-structured thin film electrolytes. The newly developed nanoscale thin films and multi-layer hetero-structures with improved oxygen ionic conductivity will have significant impact on SOFC devices.
Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.
The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.
Cylinder assay and mass measurements, the mainstay of enrichment plant verification efforts have historically been performed by International Atomic Energy Agency (IAEA) inspectors using portable equipment. For the sake of efficiency, accuracy, and timeliness, such equipment is being supplanted by unattended measurement stations. Ancillary systems must be employed with such stations to ensure that measured parameters are properly recorded, cylinders are positively identified, operations occur according to procedure, and no tampering takes place in the inspectors’ absence. Depending on the facility, it may prove feasible to track cylinders from the measurement vicinity to their storage locations using surveillance. This paper will provide a cursory description of the various subsystems associated with Pacific Northwest National Laboratory’s Integrated Cylinder Verification Station and how inattention to the requirements of such systems could seriously diminish the capability of the integrated whole.
Large areas across the United States and internationally are potentially contaminated with unexploded ordinance (UXO), with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with (1) near 100% coverage and (2) near 100% detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 to 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys, resulting in costs of approximately $100-$150/acre. In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide highresolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. Thus there is a need for other systems, which can be used for effective data collection. An Unmanned Aerial Vehicle (UAV) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission in-flight reprioritization).
A portable imaging-based measurement device is developed to perform 2D projection based measurements on an object that is difficult or dangerous to access. This device is equipped with self calibration capability and built-in operating procedures to ensure proper imaging based measurement.
Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)
Objective We describe use cases and an institutional reference architecture for maintaining high-capacity, data-intensive network flows (e.g., 10, 40, 100 Gbpsþ) in a scientific, medical context while still adhering to security and privacy laws and regulations. Materials and Methods High-end networking, packet filter firewalls, network intrusion detection systems. Results We describe a “Medical Science DMZ” concept as an option for secure, high-volume transport of large, sensitive data sets between research institutions over national research networks. Discussion The exponentially increasing amounts of “omics” data, the rapid increase of high-quality imaging, and other rapidly growing clinical data sets have resulted in the rise of biomedical research “big data.” The storage, analysis, and network resources required to process these data and integrate them into patient diagnoses and treatments have grown to scales that strain the capabilities of academic health centers. Some data are not generated locally and cannot be sustained locally, and shared data repositories such as those provided by the National Library of Medicine, the National Cancer Institute, and international partners such as the European Bioinformatics Institute are rapidly growing. The ability to store and compute using these data must therefore be addressed by a combination of local, national, and industry resources that exchange large data sets. Maintaining data-intensive flows that comply with HIPAA and other regulations presents a new challenge for biomedical research. Recognizing this, we describe a strategy that marries performance and security by borrowing from and redefining the concept of a “Science DMZ”—a framework that is used in physical sciences and engineering research to manage high-capacity data flows. Conclusion By implementing a Medical Science DMZ architecture, biomedical researchers can leverage the scale provided by high-performance computer and cloud storage facilities and national high-speed research networks while preserving privacy and meeting regulatory requirements.
Computing demands for large scientific experiments, such as the CMS experiment at the CERN LHC, will increase dramatically in the next decades. To complement the future performance increases of software running on central processing units (CPUs), explorations of coprocessor usage in data processing hold great potential and interest. Coprocessors are a class of computer processors that supplement CPUs, often improving the execution of certain functions due to architectural design choices. We explore the approach of Services for Optimized Network Inference on Coprocessors (SONIC) and study the deployment of this as-a-service approach in large-scale data processing. In the studies, we take a data processing workflow of the CMS experiment and run the main workflow on CPUs, while offloading several machine learning (ML) inference tasks onto either remote or local coprocessors, specifically graphics processing units (GPUs). With experiments performed at Google Cloud, the Purdue Tier-2 computing center, and combinations of the two, we demonstrate the acceleration of these ML algorithms individually on coprocessors and the corresponding throughput improvement for the entire workflow. This approach can be easily generalized to different types of coprocessors and deployed on local CPUs without decreasing the throughput performance. We emphasize that the SONIC approach enables high coprocessor usage and enables the portability to run workflows on different types of coprocessors.
The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.
DARMA is a portability layer for asynchronous many-task (AMT) runtime systems. AMT runtime systems show promise to mitigate challenges imposed by next generation high performance computing architectures. However, current runtime system technologies are not production-ready. DARMA is a portability layer that seeks to insulate application developers from idiosyncrasies of individual runtime systems, thereby facilitating application-developer use of these technologies. DARMA comprises a frontend application programming interface (API) for application developers, a backend API for runtime system developers, and a translation that translates frontend API calls into backend API calls. Application developers use C++ abstractions to annotate both data and tasks in their code. The DARMA translation layer uses C++ template metaprogramming to capture data-task dependencies, and provides this information to a potential backend runtime system via a series of backend API calls.