Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physics - Plasma physics , Mathematics and Computing, Physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Advances in Nuclear Data Evaluation Theory for NCSP [Slides]

The generalized form of the Bayes’ Theorem improves UQ for NCSP of differential and/or integral data evaluations and of applications. It is being implemented in an API for use by SCALE, SAMMY, etc. Extended R-matrix formalism improves evaluations of RRR including direct reactions, direct capture, and the Reich-Moore approx., doorway state reactions with applications to RPI data on lead isotopes. Extended R-Matrix formalism will be implemented into SAMMY post modernization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Horizontal Split Table Conceptual Design for Validation of Nuclear Data used in Advanced Reactors [Slides]

A methodology to create conceptual designs of benchmark critical experiments for advanced reactors nuclear data testing and validation was developed. A first concept was explored, pebble-bed high-temperature gas cooled reactor, based on the HTR-10 reactor. The very high correlation is a proof of concept that the design is similar to the application, and performing such critical experiments would help nuclear data testing and validation. This proof-of-concept was included in the IER-539 CED-1:Preliminary Design of a New Horizontal Split Table report. Other concepts could be explored if needed, such as Molten-salt reactor, Sodium-cooled fast reactor or Heat pipe reactors/Microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expanded Validation of Uranium Systems with the KENO Monte Carlo Codes and SCALE 6.2.4 [Slides]

There is likely a trend in bias for uranium-fueled systems as a function of spectrum, but probably not as a function of enrichment. Some enrichment trends appear, but are potentially the result of outlier experimental results; further investigation is needed where possible. There are good examples in this data of markedly different biases from different systems. Future work includes review and vetting for inclusion in the VALID library and analysis with TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAMMY Modernization Efforts [Slides]

This presentation details several SAMMY modernization and maintenance goals, as well as the efforts made towards these goals and future plans for SAMMY.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to the n+ 63,65 Cu Evaluations: RRR and Angular Distributions [Slides]

This work updates the evaluation of n+ 63,65 Cu for neutron energies in the resolved resonance region (RRR) and slightly higher energies. The updates strive to improve the statistical properties of the resonance parameters and the continuity of the evaluation between the RRR and the high-energy region while preserving or improving critical assembly benchmark performance. We will review our work on the resonance parameters and present the current status of our angular distribution analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Slide Rule Update - Phase 4 Plutonium Configurations – Delayed Gamma [Slides]

The fourth phase of Slide-Rule update gives a calculation scheme for DFG doses and its application to five plutonium material, as well as comparisons between radiation transport and depletion codes such as MCNP, SCALE, COG and FISPACT. Overall, DFG dose rates calculated by each laboratory led to consistent results. Extra effort is under way to identify the cause of the remaining differences, especially for case 2, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Error Study of FlecSim Using the Method of Manufactured Solutions [Slides]

Error was calculated using exact solution chosen with the method of manufactured solutions. Hydrodynamics match expected order of accuracy for spatial error within 1.5% for all variables tested. Radiation transport matches expected order of temporal accuracy within 0.5% for all variables tested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation

The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Infidelity Associated with Eliminating the Bus Resonator

This summer project started out to quantify the error associated with an approximate model of a superconducting circuit, where two qubits are dispersively coupled through a bus resonator. Understanding this error helps us decide if the approximate model is sufficient for the purpose of optimal control. We find out that the error of the approximate model covers up a nontrivial problem of the underlying circuit, which limits the fidelity of two-qubit gates under 99% for practical parameters. This suggests that high fidelity gates of this circuit cannot be achieved through optimal control alone, and changes of the parameters/design of the circuits appear necessary. Additionally, to carry out the algebra involved, a symbolic commutator algebra package HamMaker is developed in Julia. The package is capable of automating some difficult algebra in optimal control that previously had to be performed by hand. Within this work, HamMaker has been used to derived some simple but nontrivial corrections to the existing effective Hamiltonian.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

Documentation on How to Run the NEAMS Workbench GUI on Sawtooth

This document provides guidelines on how to run Moose-based applications from the NEAMS WorkbenchGUI on the HPC platform Sawtooth located at Idaho National Laboratory. The different steps are illustrated with a multi-app example modeling a sodium-cooled fast reactor (SFR) taken from the virtual test bed (VTB) website. The workflow consists of four steps to demonstrate the capabilities of the NEAMS Workbench GUI, that covers log into Sawtooth, editing and validating input files, submission of the job to the queue and visualization of the numerical solution and the geometry. Each step is illustrated with figures in the text, and a demonstration video is also available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Thermohydraulic Simulations using RELAP for Critical Dual Purpose Canisters

Simulations using the RELAP5-3D systems analysis code and STAR-CCM+, a high-fidelity CFD code, were performed on a model of a real-scale MPC-32 dual purpose canister undergoing a criticality event. These simulations were performed to provide code-to-code verification of the natural convection capabilities in RELAP5. The STAR-CCM+ simulations revealed various natural convection flow patterns that aided in the cooling of fission heat produced in the fuel rods in the canister. Negligible spatial temperature variations were observed across the canister in the STAR-CCM+ results, supporting the use of RELAP5 in predicting the sub-cooled regime. The surface-averaged rod temperature predicted by RELAP5 compared well with STAR-CCM+, verifying the predictive capability of RELAP5 for sub-cooled conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Characterization Summary: WSMR Fast Burst Reactor Environment at the 6-Inch and 24-Inch Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G), at the 6-inch and the 24-inch irradiation locations. The neutron, prompt gamma-ray, and delayed gamma-ray energy spectra, uncertainties, and covariance matrices are presented. Code dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗