Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Wear Measurement of Highly Cross-linked UHMWPE using a 7 Be Tracer Implantation Technique

The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

cross-linked↗

A High-Performance Sodium-Ion Full Cell with a Layered Oxide Cathode and a Phosphorous-Based Composite Anode

A low-cost sodium-ion full cell with a O3-type layered Na[Cu 0.2 (Fe 1/3 Mn2/3) 0.8 ]O 2 cathode and an alloy-type P-TiP2-C anode is presented. The cathode is synthesized by an oxalate coprecipitation method and optimized cathodes shows a high specific capacity of 135 mAh g -1 at 0.1C rate with a high rate capability of 90 mAh g-1 at 1C rate and 70 mAh g -1 at 2C rate with good cyclability. The full cell exhibits better capacity retention than the half cell with the cathode due to the elimination of the degradation caused by sodium-metal anode. The dramatically enhanced electrochemical performance of the Na[Cu 0.2 (Fe 1/3 Mn 2/3 ) 0.8 ]O 2 / P-TiP 2 -C full cell compared to that of the sample with no Cu is attributed to the structural stabilization imparted by Cu by suppressing the phase change from the O3 structure to the P3 structure during cycling.

25 ENERGY STORAGE↗

Numerical characterization of quasi-steady thermal load for thin crystal at cryogenic temperature with nondiffusive heat transfer

With dramatically improved brightness and repetition rate, the thermal load for crystal optics in x-ray free-electron laser applications has also significantly increased. To mitigate the thermal load, one effective method is cryogenic cooling. However, the emerging nondiffusive heat transfer phenomenon at cryogenic temperature may cause design failure if overlooked. To evaluate the optical performance of thin crystal optics under thermal load at cryogenic temperature, an integrated numerical tool is presented and applied to characterize the thermal load on thin crystals with nondiffusive phenomena accounted. Significant thermally induced distortion of the rocking curve is observed from numerical simulation, leading to potential seed power reduction in hard x-ray self-seeding application. Cryogenic cooling is confirmed necessary by simulation to handle the thermal load at high repetition rate operation.

42 ENGINEERING↗

Quantum Simulations of Radiation Damage in a Molecular Polyethylene Analog

Abstract An atomic‐level understanding of radiation‐induced damage in simple polymers like polyethylene is essential for determining how these chemical changes can alter the physical and mechanical properties of important technological materials such as plastics. Ensembles of quantum simulations of radiation damage in a polyethylene analog are performed using the Density Functional Tight Binding method to help bind its radiolysis and subsequent degradation as a function of radiation dose. Chemical degradation products are categorized with a graph theory approach, and occurrence rates of unsaturated carbon bond formation, crosslinking, cycle formation, chain scission reactions, and out‐gassing products are computed. Statistical correlations between product pairs show significant correlations between chain scission reactions, unsaturated carbon bond formation, and out‐gassing products, though these correlations decrease with increasing atom recoil energy. The results present relatively simple chemical descriptors as possible indications of network rearrangements in the middle range of excitation energies. Ultimately, the work provides a computational framework for determining the coupling between nonequilibrium chemistry in polymers and potential changes to macro‐scale properties that can aid in the interpretation of future radiation damage experiments on plastic materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dual-energy CT in the obese: a preliminary retrospective review to evaluate quality and feasibility of the single-source dual-detector implementation

Purpose: To determine the feasibility of performing dual-energy CT with a single-source spectral detector system in obese patients. Materials and methods: Retrospective, IRB-approved review of 28 patients weighing ≥ 270 lbs (122 kg) who underwent CT of the abdomen on a single-source spectral detector system was performed. Two blinded, independent radiologists rated relative preference between conventional CT images taken at 120 kVp (CCT120) and monoenergetic 70 keV equivalent (MonoE70) as well as iodine map image quality in the spleen, pancreas, kidneys, and liver. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between conventional CT and MonoE70 images and correlated with body habitus markers of weight, height, and abdominal diameter. Results: MonoE70 images were preferred by radiologists 100% of the time (1-sample t test, p < 0.0001) over conventional CCT120 images. Noise was significantly lower; SNR and CNR were significantly higher in MonoE70 images than in CCT120 images (paired t tests, p < 0.0001). Mean iodine map rating (scale 1–5) was 4.54 ± 0.58, denoting near homogenous and complete iodine mapping through the spleen, pancreas, kidneys, and liver for the majority of patients. Body habitus markers were not significantly correlated with image preference score; noise; MonoE70 SNR; MonoE70 CNR; change in noise, SNR, or CNR from CCT120 to MonoE70, or iodine map quality; ordinal and linear regression, p = 0.2547, p = 0.6837, p = 0.1888, p = 0.5489, p = 0.9830, p = 0.8849, p = 0.8741, p = 0.1522, respectively. Conclusion: The single-source spectral detector implementation of dual-energy CT provides viable, high-quality imaging for obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weldability and Impact Energy Properties of High-Hardness Armor Steel

In this study, the weldability of high-hardness armor steel by the gas metal arc welding method has been investigated. The study was aimed at determining the weakness points of manual welding compared to automated welding through microhardness testing, the cooling rate, tensile characteristics and nondestructive analysis. Detailed studies were performed for automated welding on the impact energy and microhardness in the fusion line, as the most sensitive zone of the armor steel weld joint. It was demonstrated that the selection of the preheating and interpass temperature is important in terms of the cooling rate and quantity of diffusible and retained hydrogen in the weld joint. The tensile strength was higher than 800 MPa. The width of the heat-affected zone did not exceed 15.9 mm, measured from the weld centerline, while the impact energy results were 74 and 39 J at 20 and – 40 °C, respectively.

36 MATERIALS SCIENCE↗

Inverse ZrO 2 /Cu as a highly efficient methanol synthesis catalyst from CO 2 hydrogenation

Enhancing the intrinsic activity and space time yield of Cu based heterogeneous methanol synthesis catalysts through CO 2 hydrogenation is one of the major topics in CO 2 conversion into value-added liquid fuels and chemicals. Here we report inverse ZrO 2 /Cu catalysts with a tunable Zr/Cu ratio have been prepared via an oxalate co-precipitation method, showing excellent performance for CO 2 hydrogenation to methanol. Under optimal condition, the catalyst composed by 10% of ZrO 2 supported over 90% of Cu exhibits the highest mass-specific methanol formation rate of 524 g MeOH kg cat -1 h -1 at 220°C, 3.3 times higher than the activity of traditional Cu/ZrO 2 catalysts (159 g MeOH kg cat -1 h -1 ). In situ XRD-PDF, XAFS and AP-XPS structural studies reveal that the inverse ZrO 2 /Cu catalysts are composed of islands of partially reduced 1–2 nm amorphous ZrO 2 supported over metallic Cu particles. The ZrO 2 islands are highly active for the CO 2 activation. Meanwhile, an intermediate of formate adsorbed on the Cu at 1350 cm -1 is discovered by the in situ DRIFTS. This formate intermediate exhibits fast hydrogenation conversion to methoxy. The activation of CO 2 and hydrogenation of all the surface oxygenate intermediates are significantly accelerated over the inverse ZrO 2 /Cu configuration, accounting for the excellent methanol formation activity observed.

36 MATERIALS SCIENCE↗

CAPG: comprehensive allopolyploid genotyper

Genotyping by sequencing is a powerful tool for investigating genetic variation in plants, but many economically important plants are allopolyploids, where homoeologous similarity obscures the subgenomic origin of reads and confounds allelic and homoeologous SNPs. Recent polyploid genotyping methods use allelic frequencies, rate of heterozygosity, parental cross or other information to resolve read assignment, but good subgenomic references offer the most direct information. The typical strategy aligns reads to the joint reference, performs diploid genotyping within each subgenome, and filters the results, but persistent read misassignment results in an excess of false heterozygous calls. We introduce the Comprehensive Allopolyploid Genotyper (CAPG), which formulates an explicit likelihood to weight read alignments against both subgenomic references and genotype individual allopolyploids from whole-genome resequencing data. We demonstrate CAPG in allotetraploids, where it performs better than Genome Analysis Toolkit’s HaplotypeCaller applied to reads aligned to the combined subgenomic references.

59 BASIC BIOLOGICAL SCIENCES↗

Event Cause Analysis in Distribution Networks using Synchro Waveform Measurements

This paper presents a machine learning method for event cause analysis to enhance situational awareness in distribution networks. The data streams are captured using time-synchronized high sampling rates synchro waveform measurement units (SWMU). The proposed method is formulated based on a machine learning method, the convolutional neural network (CNN). This method is capable of capturing the spatiotemporal feature of the measurements effectively and perform the event cause analysis. Several events are considered in this paper to encompass a range of possible events in real distribution networks, including capacitor bank switching, transformer energization, fault, and high impedance fault (HIF). The dataset for our study is generated using the real time digital simulator (RTDS) to simulate real-world events. The event cause analysis is performed using only one cycle of the voltage waveforms after the event is detected. The simulation results show the effectiveness of the proposed machine learning-based method compared to the state-of-the-art classifiers.

Niazazari, Iman↗

Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3 films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent{sup ®} electronic brachytherapy source (Axxent{sup ®} source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent{sup ®} source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent{sup ®} source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent{sup ®} source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent{sup ®} source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft Inc. (a subsidiary of iCAD). This work was also supported by the Radiological Sciences T32 Training Grant through the University of Wisconsin-Madison Medical Physics department (5T32CA009206-37).

60 APPLIED LIFE SCIENCES↗

Harnessing Condorcet Methods to Improve Decision-making Based on Ranked Data

Decision-makers must often choose between multiple alternatives based on their relative merits across a variety of criteria. These multiple-criteria decision-making (MCDM) problems must be approached in an objective, measurable, and transparent fashion to obtain well-supported outcomes. The challenge of using sets of ranked data to identify the optimal choice is not unlike the challenge of using ranked ballots to identify the winner of an election in a preference voting system. As such, the methods of rank aggregation used in elections can be applied to help resolve MCDM problems. Previous research into the design of elections and ballots has yielded many algorithms with well-understood properties. A subset of these, called Condorcet methods, reliably identify the “Condorcet winner,” if it exists, giving the result that would defeat any other in a pairwise comparison. That, in addition to several other desirable qualities, makes Condorcet methods like the Schulze method, Ranked Pairs, and Copeland’s method, effective and scalable means for tackling MCDM problems. These rank aggregation methods have been implemented in JavaScript functions for incorporation into a web-based MCDM decision tool. These algorithms can be applied in a wide variety of contexts (for example, determining the “best” environmental remediation method or selecting a subcontractor) to facilitate effective decision-making. The performance of the JavaScript Condorcet prototype tool was compared across the implemented algorithms and with both a non-Condorcet rank aggregation method as well as an implementation of the Simple Multi-Attribute Rating Technique (SMART) algorithm.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Test Code for Determining and Reporting Annual Heat Rate and CO2 for Coal Fueled EGUs

This material is based upon work supported by the Department of Energy under Award Number DEFE0031933. The US Department of Energy (DOE) has retained the services of ASME Standards Technology LLC (ASME ST-LLC) to develop a standardized test method and calculation protocol for determining and reporting annual/long-term heat rate for coal-fueled plants electricity generating units. ASME ST-LLC has retained the services of McHale & Associates, Inc. and Licata Energy & Environmental Consultants, Inc. to provide the technical input to this study. This code applies to hydrocarbon fueled Rankine cycle power generating facilities of any size. It is intended to be used for the determination of continuous power output and heat rate of a generating facility in its operating load cycle and in its operational lineup during the reporting period.

01 COAL, LIGNITE, AND PEAT↗

Implementation of Perturbation Theory and Sensitivity Capabilities in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor Multiphysics analysis application, jointly developed by Argonne and Idaho National Laboratories under the DOE-NE NEAMS program. This fiscal year, capabilities for reactivity and sensitivity evaluation using perturbation methods were implemented and verified. The First Order Perturbation Method (FOPT) was employed to compute reactivity worth resulting from small perturbations in input parameters, while the Generalized Perturbation Theory (GPT) was used to evaluate sensitivities of a range of response types, including reaction rate ratio, k-eigenvalue, neutron generation time, and effective delayed neutron fraction. These perturbation methods enable users to quantify how response quantities change due to a perturbation in a input parameter without explicitly performing an additional transport simulation for each perturbed state. In particular, the GPT formulation accounts for indirect effects arising from flux changes by solving generalized inhomogeneous equations, for which a Neumann series-based iterative solution method was developed and implemented in Griffin. The implemented reactivity and sensitivity evaluation capabilities were verified using two test problems: an infinite homogeneous system and a two-dimensional hexagonal core. The results showed excellent agreement with reference solutions obtained by a direct method based on finite difference approximation as well as GPT-based results from the PERSENT code, confirming the accuracy of both reactivity and sensitivity evaluations. Additionally, preliminary uncertainty quantification (UQ) results were obtained by combining the sensitivity values computed using GPT and external covariance data, demonstrating that the implemented sensitivity results can be reliably used for uncertainty calculations. To further demonstrate the generality and practical strength of the implementation, the sensitivity evaluation capability was successfully applied to the Empire microreactor with a geometrically complex design that poses significant modeling challenges. The results confirm that Griffin enables sensitivity evaluations even for irregular and highly heterogeneous reactor configurations, thereby establishing a foundation for UQ applications in advanced reactor designs and analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Issues Associated with Compensating and Competing Processes in Climate Models: an Example from ECHAM-HAM

The purpose of this paper is to draw attention to the need for appropriate numerical techniques to represent process interactions in climate models. In two versions of the ECHAM-HAM model, different time integration methods are used to solve the sulfuric acid (H2SO4) gas evolution equation, which lead to substantially different results in the H2SO4 gas concentration and the aerosol nucleation rate. Using convergence tests and sensitivity simulations performed with various time stepping schemes, it is confirmed that numerical errors in the second model version are significantly smaller than those in version one. The use of sequential operator splitting in combination with long time step is identified as the main reason for the large systematic biases in the old model. The remaining errors in version two in the nucleation rate, related to the competition between condensation and nucleation, have a clear impact on the simulated concentration of cloud condensation nuclei in the lower troposphere. These errors can be significantly reduced by employing an implicit solver that handles production, condensation and nucleation at the same time. Lessons learned in this work underline the need for more caution when treating multi-time-scale problems involving compensating and competing processes, a common occurrence in current climate models.

climate↗

Development of Accelerated Steady-state Test Capsule Experiments to Replicate EBR-II Fuel Behavior Using BISON Fuel Performance Analysis

Here in this work, BISON fuel performance calculations were performed to predict the fuel behavior of accelerated burnup U-Pu-Zr fuel, with temperature operation conditions of the fuel and the cladding mirroring conditions within EBR-II fuel pins. The temperature operating conditions within the FAST accelerated burnup rods were aimed at replicating EBR-II X447/X447A fuel surface and inner cladding surface temperatures. Due to the FAST capsule design, these temperatures can be replicated with fission rate densities being significantly increased. fuel performance modeling has not been assessed for novel experiments such as accelerated burnup utilizing the FAST capsule within ATR. This is an important step in understanding accelerated irradiation methods as many performance models are empirical models conforming to the results of PIE but do not always include physical models that would represent the changes in irradiation tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Room Temperature, Dip Coating Organic Passivation for c-Si Surfaces

Surface passivation of crystalline Si (c-Si) to reduce recombination rate is crucial to obtain high-efficiency c-Si solar cells. A fast passivation technique that can be performed at room temperature is needed when studying the degradation behaviors using various characterization methods to not destroy the degraded states. In this contribution, we explore Nafion via dip coating on n-type Cz wafers. We show that both the Nafion concentration and the conditions of surface and edge affect the passivation quality, and we achieve excellent passivation quality of iVoc of 716 mV, with a saturation current density (J0) of 7 fA/cm2. Additionally, electron paramagnetic resonance (EPR) shows Nafion can be used under cryogenic temperature and reveals the reduction of Si dangling bond after Nafion treatment.

dielectric solar cell↗

Evaluating methods to reduce duration of near-threshold fatigue crack growth rate measurements for low-alloy steels in hydrogen gas

Measurement of the near-threshold fatigue crack growth rate (da/dN) vs. stress-intensity factor range (∆K) relationship in hydrogen gas is essential for maximizing the calculated design fatigue life of high-pressure hydrogen storage vessels. However, such measurements are rarely performed, since the low cyclic loading frequencies applied in standard practice lead to prohibitively protracted test durations. The objective of this study was to demonstrate two means for reducing test durations when measuring near-threshold da/dN vs. ΔK relationships under decreasing ΔK for low-alloy pressure vessel steels in hydrogen gas: 1) imposing steeper K-gradients relative to the recommended limits in standards such as ASTM E647, and 2) increasing cyclic loading frequency relative to typical values applied during fatigue crack growth testing of low-alloy steels in hydrogen gas. Recognizing that steeper K-gradients could amplify loading-history effects, test methods employing this approach were designed to mitigate such effects by either maintaining constant K max or gradually increasing the K-gradient as the threshold was approached. Although the varying K-gradient method was vulnerable to loading-history effects in the form of plasticity-induced crack closure, particularly at lower stress ratio (R) and higher starting K max values, these effects could be compensated by applying the adjusted compliance ratio (ACR) method. Here, it was demonstrated that steeper K-gradients in concert with increased cyclic loading frequency reduced the duration of near-threshold fatigue crack growth tests in hydrogen gas by more than 99% relative to standard practices.

Fatigue threshold↗