Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTOTYPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Prototyping high-gradient mm-wave accelerating structures

We present single-cell accelerating structures designed for high-gradient testing at 110 GHz. The purpose of this work is to study the basic physics of ultrahigh vacuum RF breakdown in high-gradient RF accelerators. The accelerating structures are π-mode standing-wave cavities fed with a TM 01 circular waveguide. The structures are fabricated using precision milling out of two metal blocks, and the blocks are joined with diffusion bonding and brazing. The impact of fabrication and joining techniques on the cell geometry and RF performance will be discussed. First prototypes had a measured Q 0 of 2800, approaching the theoretical design value of 3300. The geometry of these accelerating structures are as close as practical to singlecell standing-wave X-band accelerating structures more than 40 of which were tested at SLAC. This wealth of X-band data will serve as a baseline for these 110 GHz tests. Furthermore, the structures will be powered with short pulses from a MW gyrotron oscillator. RF power of 1 MW may allow an accelerating gradient of 400 MeV/m to be reached.

43 PARTICLE ACCELERATORS↗

Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

We investigated the active pixel sensors based on the High-Voltage CMOS technology as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. Our paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. These results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for two active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An optimized prototype of electromagnetic calorimeter for the SoLID project at Jefferson Lab

A shashlik-type electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for the Solenoidal Large Intensity Device (SoLID). Wavelength-shifting (WLS) fibers and clear fibers will be used as the light guide part of the calorimeter. The blue light from scintillators is converted into green light by WLS fibers and is carried out to the back of the calorimeters for readout. Since the magnetic field of SoLID reaches about 1.5 T behind the calorimeters, the design is to use clear fibers to further guide the light out of the solenoid for readout by PMTs. Therefore, it is important to study the perfomance of WLS and clear fibers. This paper describes a comparative test of two different WLS fibers and a light attenuation test for a clear fiber. The results show that the performance of the two WLS fibers is the same under large curvature bending, and that the bending has no effect on the light transmission through the clear fiber. In addition, a comparison test for two fiber end-face reflective materials is also reported. It reveals that the use of silver ink as a reflective material can increase the light yield by 30%. Thereby, an optimized prototype based on the above experimental results was built and the basic performance was tested.

Shen, C.↗

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Here, the 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achievable noise performance of spectroscopic prototype DEPFET detectors

A new generation of spectroscopic X-ray DEPFET detectors has been produced here in the course of the detector development for the Wide Field Imager (WFI) of Athena. These devices served to perform a detailed analysis of the noise composition, which was enabled by the development of appropriate test algorithms. A result of the analysis is the distinction of different components, which sum up to the total noise. In particular the contribution of shot noise, white noise and 1/f noise to the readout noise is determined as well as the signal noise caused by the generation of charge carriers. The resulting parametrization enables the adaptation and optimization of operation modes to given purposes. The studied prototype detectors included 64×64 pixels with a linear gate design and provided an excellent noise, below 1.6 e - ENC at a readout time faster than 10 μs/pixel and a temperature of -80 °C in rolling-shutter operation. This performance is enabled by an extended signal integration time. A further noise reduction is prevented by the signal noise, caused by charge carrier generation. In order to demonstrate the low noise properties of the DEPFET transistor, the measurement conditions were adapted and a noise of 0.95 e - ENC was measured at the expense of the sensor size—by operating only parts of the sensor in window mode—and dynamic range—by using the Al Kα line at about 1.49 keV for calibration.

47 OTHER INSTRUMENTATION↗

Solid state streak camera prototype performance testing and future upgrades

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolving diagnostics for studying events that occur on the nanosecond to microsecond time scales. The Nevada National Security Site (NNSS) and Sandia National Laboratories (SNL) have built a 42-channel solid state streak camera (SSSC) prototype as a proof of concept for use as a streak camera replacement. This work is part of an ongoing project to develop the technology to a level competitive with analog streak cameras. This manuscript discusses the device concept, results from electronic and laser testing, and recent improvements to increase the device’s dynamic range.

Plasma diagnostics - interferometry, spectroscopy ↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7 ± 8.1 μm was measured for one chamber and 101.8 ± 7.8 μm for the other, compared with a design resolution of 106 μm. A further tracking resolution improvement to 83.4 ± 7.8 μm was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5 ± 0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.

43 PARTICLE ACCELERATORS↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗