LOW VISCOSITY BEARING STABILITY INVESTIGATION SECOND QUARTERLY PROJECT
Turbomachinery bearing configurations - tests for long term, unattended operation with low viscosity lubricants in space environment
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Turbomachinery bearing configurations - tests for long term, unattended operation with low viscosity lubricants in space environment
This study presents the effect of the tuning capacitor on the stability and electrical power output of a gas spring-based free-piston Stirling convertor (FPSC) when the FPSC runs on a forced-oscillation type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Recent modeling analysis, however, suggests that while the effect on the stability is significant, the effect on the electrical power output is almost negligible as long as the operating frequency the FPSC is fixed by a forced-oscillation controller and operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and pressure, are unchanged. To verify the modeling analysis results, Advanced Stirling Convertor (ASC) is controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value is changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with the three tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The test results suggest that when the FPSC operates at a fixed frequency, the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather significant. Therefore, the tuning capacitor value should be selected toward the highest stability.
Data is presented on the phase and frequency stability, over time periods extending to one week, of the new NR field operable hydrogen masers developed by the Applied Physics Laboratory (APL) and the older NX and NP field operable hydrogen masers developed by Goddard Space Flight Center and maintained and upgraded by Bendix Field Engineering Corporation (BFEC). Data is presented on the NR masers in the laboratory showing frequency stabilities well into the 10 to the -15th power range and phase stabilities well into the 100 ps range for periods of up to one day. Data is presented on upgraded NP masers in the laboratory showing that the frequency stability has been improved substantially to virtually the NR level. VLBI data is presented on the phase difference between NX-2 at Owens Valley, California and NR-2 at Fort Davis, Texas for a one week period showing, after removal of a constant frequency drift, a 350 ps RMS phase stability.
The construction of an ion thruster module (including thruster, power conditioning, and control system) capable of operating for 10,000 hours over a five to one range at an effective specific impulse of approximately 2800 seconds is discussed. The several interrelated tasks involved in the construction of the engine are described. Performance tests of the engine and the effects of various modifications are reported. It was demonstrated that thruster performance and stability were not materially affected by reasonable changes from the nominal operating point.
An investigation has been made to determine the effect of ground proximity on the aerodynamic characteristics of aspect-ratio-1 airfoils. The investigation was made with the model moving over the water in a towing tank in order to eliminate the effects of wind-tunnel walls and of boundary layer on ground boards at small ground clearances. The results indicated that, as the ground was approached, the airfoils experienced an increase in lift-curve slope and a reduction in induced drag; thus, lift-drag ratio was increased. As the ground was approached, the profile drag remained essentially constant for each airfoil. Near the ground, the addition of end plates to the airfoil resulted in a large increase in lift-drag ratio. The lift characteristics of the airfoils indicated stability of height at positive angles of attack and instability of height at negative angles; therefore, the operating range of angles of attack would be limited to positive values. At positive angles of attack, the static longitudinal stability was increased as the height above the ground was reduced. Comparison of the experimental data with Wieselsberger's ground-effect theory (NACA Technical Memorandum 77) indicated generally good agreement between experiment and theory for the airfoils without end plates.
Figure 1 shows a simplified block diagram of an improved optoelectronic system for locking the phase of one laser to that of another laser with an adjustable offset frequency specified by the user. In comparison with prior systems, this system exhibits higher performance (including higher stability) and is much easier to use. The system is based on a field-programmable gate array (FPGA) and operates almost entirely digitally; hence, it is easily adaptable to many different systems. The system achieves phase stability of less than a microcycle. It was developed to satisfy the phase-stability requirement for a planned spaceborne gravitational-wave-detecting heterodyne laser interferometer (LISA). The system has potential terrestrial utility in communications, lidar, and other applications. The present system includes a fast phasemeter that is a companion to the microcycle-accurate one described in High-Accuracy, High-Dynamic-Range Phase-Measurement System (NPO-41927), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 22. In the present system (as in the previously reported one), beams from the two lasers (here denoted the master and slave lasers) interfere on a photodiode. The heterodyne photodiode output is digitized and fed to the fast phasemeter, which produces suitably conditioned, low-latency analog control signals which lock the phase of the slave laser to that of the master laser. These control signals are used to drive a thermal and a piezoelectric transducer that adjust the frequency and phase of the slave-laser output. The output of the photodiode is a heterodyne signal at the difference between the frequencies of the two lasers. (The difference is currently required to be less than 20 MHz due to the Nyquist limit of the current sampling rate. We foresee few problems in doubling this limit using current equipment.) Within the phasemeter, the photodiode-output signal is digitized to 15 bits at a sampling frequency of 40 MHz by use of the same analog-to-digital converter (ADC) as that of the previously reported phasemeter. The ADC output is passed to the FPGA, wherein the signal is demodulated using a digitally generated oscillator signal at the offset locking frequency specified by the user. The demodulated signal is low-pass filtered, decimated to a sample rate of 1 MHz, then filtered again. The decimated and filtered signal is converted to an analog output by a 1 MHz, 16-bit digital-to-analog converters. After a simple low-pass filter, these analog signals drive the thermal and piezoelectric transducers of the laser.
As of July, 2000 the Enhanced Thematic Mapper Plus (ETM+) sensor on Landsat-7 has been operating on-orbit for about 15 months. The ETM+ images the Earth in has eight spectral bands in the visible, near-infrared (IR), short wavelength infrared (SWIR), and thermal portions of the spectrum. Three on-board calibration systems are available for the reflective bands: (1) the Internal Calibrator (IC), (2) the Partial Aperture Solar Calibrator (PASC), and (3) the Full Aperture Solar Calibrator (FASC). The Internal Calibrator also provides the thermal band calibration. Several investigators on the Landsat science team are also regularly performing vicarious calibrations. The internal calibrator, which during much of the pre-launch testing and early on-orbit check out period, showed up to 15% variability with time, has since stabilized as the instrument has assumed a regular schedule of operations and is now typically showing only a few percent variation with time, mostly associated with warm-up. The PASC has been the most variable of the sources: the response to the PASC has increased by as much as 50% is some bands and is oscillating with time, perhaps due to contamination. The FASC has been the most stable of the sources: mid scan response to the FASC diffuser have varied from -4%/yr for band 4 (0.83 microns) to -2%/yr for band 1 (0.49 microns) to +1%/yr for band 7 (2.2 microns). These decreases in response in bands 1-4 would have been about half as large if measured on the right (west) side of the panel and about twice as large if measured on the left side of the panel. The current interpretation is that the FASC diffuser panel is changing non-uniformly in its reflectance characteristics. Vicarious ground measurements have generally been consistent with the pre-launch measurements of the instrument responsivity and have not shown evidence of a change in responsivity with time. The FASC, IC, and vicarious results suggest the instrument has not changed by more than two percent in responsivity since launch and that the absolute calibration is good to the advertised five percent.
Development and certification tests have been conducted on the Space Shuttle Main Engine to verify design changes made on the high-pressure turbopumps to expand operating margin at full-power level, increase life, and reduce maintenance requirements. Design changes are summarized and the verification process is described in detail. Methods of testing turbopumps for increased rotor stability, reduced bearing loads, extended bearing and turbine blade life, and reduced turbine operating temperatures are also described. Accomplishments to date in extending both the power level and life of the SSME are summarized.
The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. Two forward-slanted slot stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of 18.5 percent was obtained with the superior configuration if a constant pressure was maintained in the bypass plenum. Limited unstart angle-of-attack data are presented.
In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.
Increasing jet aircraft fuel costs from 25 percent to nearly 60 percent of the aircraft direct operating costs have led to a heavy emphasis on the development of transport aircraft with significantly improved aerodynamic performance. The application of the concept of relaxed static stability (RSS) and the utilization of an active control stability augmentation system make it possible to design an aircraft with reduced aerodynamic trim drag due to a farther-aft cg balance. Reduced aerodynamic parasite drag and lower structural weight due to a smaller horizontal tail surface can also be obtained. The application of RSS has been studied under a NASA-sponsored program to determine ways of improving the energy efficiency in current and future transport aircraft. Attention is given to a near-term pitch active control system, an advanced pitch active control system, and an operational overview.
The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.
Computer programs for calculating the stability characteristics of a balloon tethered in a steady wind are presented. Equilibrium conditions, characteristic roots, and modal ratios are calculated for a range of discrete values of velocity for a fixed tether-line length. Separate programs are used: (1) to calculate longitudinal stability characteristics, (2) to calculate lateral stability characteristics, (3) to plot the characteristic roots versus velocity, (4) to plot the characteristic roots in root-locus form, (5) to plot the longitudinal modes of motion, and (6) to plot the lateral modes for motion. The basic equations, program listings, and the input and output data for sample cases are presented, with a brief discussion of the overall operation and limitations. The programs are based on a linearized, stability-derivative type of analysis, including balloon aerodynamics, apparent mass, buoyancy effects, and static forces which result from the tether line.
One important aspect of the WFIRST coronagraphic instrument (CGI) technology demonstration is its ability to take high contrast spectra with an integral field spectrograph (IFS). Future missions such as LUVOIR and HabEx rely on IFS technologies for the spectral characterization of any objects they discover; spectral characterization is the core science of their exoplanet imaging instruments. The CGI IFS, being designed and built and Goddard Space Flight Center, has a spectral resolution of R50 and is designed to accommodate a 20% bandpass spanning 600-970nm. The bands and spectral resolution were chosen by the science investigation teams to target key methane absorption features, with the aim of constraining abundances. For CGI as a technology demonstration, these are the minimum set of defining features to demonstrate on-orbit wavefront control with an IFS capable of producing science. The ability to close a wavefront control loop around an IFS, maintain a stable dark hole, and provide time resolved data that simultaneously spans spatial and spectral dimensions are crucial demonstrations for future observatories. We highlight the IFS requirements and how the on-orbit calibration is handled. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, anticipated performance, and operations concept of the CGI IFS.
A pitch active control system (PACS) was developed and flight tested on a wide body jet transport (L-1011) with a flying horizontal stabilizer. Two dual channel digital computers and the associated software provide command signals to a dual channel series servo which controls the stabilizer power actuators. Input sensor signals to the computer are pitch rate, column trim position, and dynamic pressure. Control laws are given for the PACS and the system architecture is defined. Discussions are given regarding piloted flight simulation and vehicle system simulation and vehicle system simulation tests that are performed to verify control laws and system operation prior to installation on the aircraft. Modifications to the basic aircraft included installation of the PACS, addition of a c.g. management system to provide a c.g. range from 25 to 39% mac, and downrigging of the geared elevator to provide the required nose down control authority for aft c.g. flight test conditions. Three pilots used the Cooper-Harper Rating Scale to judge flying qualities of the aircraft with PACS on and off. The handling qualities with the c.g. at 39% mac (41% stability margin) and PACS operating were judged to be as good as the handling qualities with the c.g. at 25% mac (+15% stability margin) and PACS off.
This study presents the effect of the tuning capacitor on stability and electrical power output of a gas-bearing based free-piston Stirling convertor (FPSC) when operating on a fixed-frequency type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Models suggest the stability of the FPSC is strongly coupled to the tuning capacitance, while the coupling to the electrical power output is weak. This applies to cases where the operating frequency of the FPSC is fixed by a fixed-frequency controller and other operating conditions, such as the hot-end and cold-end temperatures, piston amplitude, and pressure are constant. To verify the modeling analysis results, an Advanced Stirling Convertor (ASC) was controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value was changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with different tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The experimental test results verified that the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather noticeable. Therefore, the ideal tuning capacitor value should be selected based on required stability of the FPSC.
Future NASA and Air Force missions require reliable and safe sources of energy with high specific energy and energy density that can provide thousands of charge-discharge cycles at more than 40% depth- of-discharge and that can operate at low temperatures. All solid-state batteries have substantial advantages with respect to stability, energy density, storage fife and cyclability. Among all solid-state batteries, those with flexible polymer electrolytes offer substantial advantages in cell dimensionality and commensurability, low temperature operation and thin film design. The above considerations suggest that lithium-polymer electrolyte systems are promising for high energy density batteries and should be the systems of choice for NASA and US Air Force applications. Polyelectrolytes (single ion conductors) are among most promising avenues for achieving a major breakthrough 'in the applicability of polymer- based electrolyte systems. Their major advantages include unit transference number for the cation, reduced cell polarization, minimal salt precipitation, and favorable electrolyte stability at interfaces. Our research is focused on synthesis, modeling and cell testing of single ion carriers, polyelectrolytes. During the first year of this project we attempted the synthesis of two polyelectrolytes. The synthesis of the first one, the poly(ethyleneoxide methoxy acrylateco-lithium 1,1,2-trifluorobutanesulfonate acrylate, was attempted few times and it was unsuccessful. We followed the synthetic route described by Cowie and Spence. The yield was extremely low and the final product could not be separated from the impurities. The synthesis of this polyelectrolyte is not described in this report. The second polyelectrolyte, comb polysiloxane polyelectrolyte containing oligoether and perfluoroether sidechains, was synthesized in sufficient quantity to study the range of properties such as thermal stability, Li- ion- conductivity and stability toward lithium metal. Also, the batteries containing this polyelectrolyte were assembled and tested. The results are detailed below. The synthesis of another polyelectrolyte similar to polysiloxane polyelectrolyte has been started, however, the synthesis was not completed due to termination of the project.
This paper describes the techniques and the equipment used in the assembly and alignment of the Cryogenic Limb Array Etalon Spectrophotometer (CLAES) Telescope and Spectrometer, together with those used to test the system at operating temperatures in order to establish the correct focus for the detector array and other system components. In addition, cryogenic tests were used to determine the stability of the optics over the specified environment, and blur size measurements were performed at operational temperatures.