Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICS DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Three-beam hybrid fs/ps coherent anti-Stokes Raman scattering of rotation–vibration non-equilibrium

In this work, we demonstrate time-resolved rotational and vibrational temperature measurements to probe plasma non-equilibrium through a simple three-beam hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system. A single pump/Stokes pair is employed to generate both the pure-rotational and ro-vibrational Raman coherence. A novel phase-matching scheme, to our knowledge, is employed to spatially overlap the two CARS signals, simplifying the optical design and allowing signal selection by tuning a single spectrometer grating. Measurements were performed near the electrodes in a N 2 DC glow discharge. Both the rotational temperature and the vibrational populations up to $v$ = 8 were calculated from the separately measured single-shot pure-rotational and ro-vibrational CARS spectra. Strong rotation–vibration non-equilibrium was observed at both electrodes, with the cathode showing higher vibrational and rotational temperatures. In addition, non-Boltzmann behaviors were observed at both electrodes. This simplified approach enables measurements of rotational and vibrational temperatures with high spatial resolution in non-equilibrium flows.

42 ENGINEERING↗

The Luminosity Reduction with Hourglass Effect and Crossing Angle in an e-p Collider

This paper derived the luminosity reduction caused by crossing angle and hourglass effect in an asymmetric collision. Here, we gave the general expressions of the geometrical reduction factor of luminosity for the asymmetric case caused by crossing angle and hourglass effect,for tri-Gaussian bunches colliding. We also gave it simple expression in some special cases to recover the earlier results, such as the formulas for only hour-glass effect exist and only crossing angle exist. The expressions used in e-p collider are also analysed in detail.

Zhang, Yuhong↗

nuSTORM FFAG Decay Ring

The neutrino beam produced from muons decaying in a storage ring would be an ideal tool for precise neutrino cross section measurements and search for sterile neutrinos due to its precisely known flavour content and spectrum. In the proposed nuSTORM facility pions would be directly injected into a racetrack storage ring, where circulating muon beam would be captured. The storage ring has two options: a FODO solution with large aperture quadrupoles and a racetrack FFAG (Fixed Field Alternating Gradient) using the recent developments in FFAGs. Machine parameters, linear optics design and beam dynamics are discussed in this paper.

43 PARTICLE ACCELERATORS↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

Increasing the efficiency of organic solar cells by photonic and electrostatic-field enhancements

Organic photovoltaic (OPV) technology is an attractive solar-electric conversion paradigm due to the promise of low cost roll-to-roll production and amenability to flexible substrates. Power conversion efficiency (PCE) exceeding 7% has recently been achieved. OPV cells suffer from low charge carrier mobilities of polymers, leading to recombination losses, higher series resistances and lower fill-factors. Thus, it is imperative to develop fabrication methodologies that can enable efficient optical absorption in films thinner than optical absorption length. Active layers conformally deposited on light-trapping, microscale textured, grating-type surfaces is one possible approach to achieve this objective. In this study, 40% theoretical increase in photonic absorption over flat OPVs is shown for devices with textured geometry by the simulation results. For verifying this theoretical result and improving the efficiency of OPVs by light trapping, OPVs were fabricated on grating-type textured substrates possessing t pitch and -coat PV active-layer on these textured substrates led to over filling of the valleys and shunts at the crest, which severely affected the performance of the resultant PV devices. Thus, it is established that although the optical design is important for OPV performance but the potential of light trapping can only be effectively tapped if the textures are amenable for realizing a conformal active layer. It is discovered that if the height of the underlying topographical features is reduced to sub-micron regime (e.g. 300 nm) and the pitch is increased to more than a micron (e.g. 2 μm), the textured surface becomes amenable to coating a conformal PV active-layer. The resultant PV cells showed 100% increase in average light absorption near the band edge due to trapping of higher wavelength photons, and 20% improvement in power conversion efficiency as compared with the flat PV cell. Another factor that severely limits the performance of OPVs is recombination of charge carriers. Thus it becomes imperative to understand the effect of processing conditions such as spin coating speed and drying rate on defect density and hence induced carrier recombination mechanism. In this study, It is shown that slow growth (longer drying time) of the active-layer leads to reduction of sub-bandgap traps by an order of magnitude as compared to fast grown active-layer. By coupling the experimental results with simulations, it is demonstrated that at one sun condition, slow grown device has bimolecular recombination as the major loss mechanism while in the fast grown device with high trap density, the trap assisted recombination dominates. It has been estimated that non-radiative recombination accounts nearly 50% of efficiency loss in modern OPVs. Generally, an external bias (electric field) is required to collect all the photogenerated charges and thus prevent their recombination. The motivation is to induce additional electric field in otherwise low mobility conjugated polymer based active layer by incorporating ferroelectric dipoles. This is expected to facilitate singlet exciton dissociation in polymer matrix and impede charge transfer exciton (CTE) recombination at polymer:fullerene interface. For the first time, it is shown that the addition of ferroelectric dipoles to modern bulk heterojunction (BHJ) can significantly improve exciton dissociation, resulting in a ~50% enhancement of overall solar cell efficiency. The devices also exhibit the unique ferroelectric-photovoltaic effect with polarization-controlled power conversion efficiency.

14 SOLAR ENERGY↗

Toward Simultaneous Single-Particle Chemical and Optical Characterization: Development of a Multi-Angle Optical Scattering Module for the Aerosol Time-of-Flight Mass Spectrometer (Final Report)

This project was an initial effort to investigate the feasibility of an instrument combining real-time atmospheric particle composition measurements using an ATOFMS (Atmospheric Time-Of-Flight Mass Spectrometer) such as those performed by Prather’s group at the University of California, San Diego (UCSD) with multi-wavelength scattering measurements of the type investigated by Sorensen et al., of Kansas State University (KSU). In this Phase I effort we proposed to investigate near-angle scattering and the possibility of integration of a multi-wavelength scattering instrument into the UCSD ATOFMS. After an initial optical design and calculations, we discovered issues with the theory of measurement and with mechanical integration. Evidence emerged that the method of multi-wavelength scattering is only efficacious for spherical particles, while most atmospheric particles are non-spherical fractal aggregates. We also determined that the integration of the detector into existing ATOFMS instruments would be severely limited by volume constraints, and additional volume would require prohibitive additional pumping compared with the existing ATOFMS systems. Based on this evidence, we decided not to pursue a Phase II effort.

47 OTHER INSTRUMENTATION↗

Maximum Current of the NSLS-II Linac

The maximum current of the NSLS-II linac is an important operational parameter for determining the safety envelope of the acceleration. In this document we establish the maximum current of the NSLS-II linac. First we establish the maximum current that can be emitted by the gun and the parameters that limit this. Then we show that beam loading in the linac further limits the current available at the exit of the linac. Beam loading also determines the energy spectrum of the beam at the end of the linac. Once the maximum current at the exit of the linac is established, we transport this beam through the linac to booster transport line using the designed optics which will match the beam from the linac into the booster. This will determine the maximum current that can be delivered to the booster accelerator from the linac.

36 MATERIALS SCIENCE↗

Ionization Cooling using Parametric Resonances. Final Technical Report on SBIR Project DE-FG02-04ER84016

Ionization Cooling using Parametric Resonances was an SBIR project begun in July 2004 and ended in January 2008 with Muons, Inc., (Dr. Rolland Johnson, PI), and Thomas Jefferson National Accelerator Facility (JLab) (Dr. Yaroslav Derbenev, Subcontract PI). The project was to develop the theory and simulations of Parametric-resonance Ionization Cooling (PIC) so that it could be used to provide the extra transverse cooling needed for muon colliders in order to relax the requirements on the proton driver, reduce the site boundary radiation, and provide a better environment for experiments. During the course of the project, the theoretical understanding of PIC was developed [1,2] and a final exposition is ready for publication [Appendix I]. Workshops were sponsored by Muons, Inc. in May and September of 2007 that were devoted to the PIC technique [3]. One outcome of the workshops was the interesting and somewhat unexpected realization that the beam emittances using the PIC technique can get small enough that space charge forces can be important. A parallel effort to develop our G4beamline simulation program to include space charge effects was initiated to address this problem [4]. A method of compensating for chromatic aberrations by employing synchrotron motion was developed and simulated [5 and Appendix II]. A method of compensating for spherical aberrations using beamline symmetry was also developed and simulated [6 and Appendix III]. Different optics designs have been developed [7] using the OptiM program in preparation for applying our G4beamline simulation program, which contains all the power of the Geant4 toolkit. However, no PIC channel design that has been developed has had the desired cooling performance when subjected to the complete G4beamline simulation program. This is believed to be the consequence of the difficulties of correcting the aberrations associated with the naturally large beam angles and beam sizes of the PIC method that are exacerbated by the fringe fields of the rather complicated channel designs that have been attempted. That is, while the designs developed and tested using the matrix program OptiM can work well, a real simulation with lumped dipoles, quadrupoles, and solenoids and their associated fringe fields has not succeeded. As a consequence of this realization, a new approach is being attempted that is based on the use of a helical solenoid (HS) channel that is made of simple coils that provide a much more homogeneous magnetic field. However, in order to use the HS a new approach was required to generate a variable dispersion that is needed according to the PIC theory described above. This approach and its first implementation will be described at EPAC08 in June, 2008 [8]. In the sections of the report that follow, the general theory of muon beam cooling is described starting from the basic ideas of ionization cooling and ending with the PIC ideas that have been developed in this project.

42 ENGINEERING↗

Maximum Current of the NSLS-II Linac

The maximum current of the NSLS-II linac is an important operational parameter for determining the safety envelope of the acceleration. In this document we establish the maximum current of the NSLS-II linac. First we establish the maximum current that can be emitted by the gun and the parameters that limit this. Then we show that beam loading in the linac further limits the current available at the exit of the linac. Beam loading also determines the energy spectrum of the beam at the end of the linac. Once the maximum current at the exit of the linac is established, we transport this beam through the linac to booster transport line using the designed optics which will match the beam from the linac into the booster. This will determine the maximum current that can be delivered to the booster accelerator from the linac.

36 MATERIALS SCIENCE↗

Lens and Camera Arrays for Sky Surveys and Space Surveillance

In recent years, a number of sky survey projects have chosen to use arrays of commercia l cameras coupled with commercial photographic lenses to enable low-cost, wide-area observation. Projects such as SuperWASP, FAVOR, Raptor, Lotis, PANOPTES, and Dragonfly rely on multiple cameras with commercial lenses to image wide areas of the sky each night. The sensors are usually commercial astronomical change coupled devices (CCD) or digital single reflex (DSLR) cameras, while the lenses are large-aperture, high-end consumer items intended for general photography. While much of this equipment is very capable and relatively inexpensive, this approach comes with a number of significant limitations that reduce sensitivity and overall utility of the image data. The most frequently encountered limitations include lens vignetting, narrow spectral bandpass, and relatively large point spread function. Understanding these limits helps to assess the utility of the data, and identify areas where advanced optical designs could significantly improve survey performance.

42 ENGINEERING↗

Measurements and Modeling of Black-Carbon Aerosols in the Arctic

We have made the first continuous measurements of black carbon in Barrow, Alaska at the ARM aerosol-observing site at the NOAA Barrow Observatory using a Single-Particle Soot Photometer (SP2). These data demonstrate that BC particles are extremely small, and a majority of the particles (by number density) are smaller than 0.5 fg, the lower limit of reliability of the SP2. We developed the first numerical model capable of quantitatively reproducing the laser-induced incandescence (LII) and scattering signals produced by the SP2, the industry-standard BC instrument. Our model reproduces the SP2 signal temporally and spectrally and demonstrates that the current SP2 optical design allows substantial contamination of LII on the scattering signal. We ran CAM5-SE in nudged mode, i.e., by constraining the transport used in the model with meteorological data. The results demonstrate the problem observed previously of under-predicting BC at high latitudes. The cause of the discrepancy is currently unknown, but we suspect that it is associated with scavenging and rainout mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Raman Spectroscopy for the On Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of new combustion approaches such as chemical looping combustion (CLC). This process is based on using oxygen carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide the oxygen for the combustion process. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. Our goal is to develop a sensor for the on-line analysis of the oxidation state of oxygen carrier particles and to demonstrate its feasibility. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. The expected results are to be of a statistical nature, providing relative concentrations of the different oxidation states. These requirements make a strong case for using non-contact, stand-off, pulsed Raman spectroscopy as a sensor for the high-temperature on-line analysis of oxygen carrier particles. In order to achieve our goal, we have set up and tested a pulsed Raman spectroscopy system in combination with a pressurized high-temperature sample chamber, and have taking initial Raman spectra of various materials at high temperature. We are now in the process of optimizing the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, data acquisition, etc. We will also develop an analysis procedure for the interpretation of the Raman spectra. Typical Raman spectra consist of a convolution of background signal and multiple individual spectra. In order to extract relevant information such as the concentration ratio of a material in different oxidation states, we need to process (background subtraction, deconvolution, fitting, etc.) the measured data. In addition, statistical modeling and multivariate calibration need to be performed to correctly analyze the Raman spectra.

20 FOSSIL-FUELED POWER PLANTS↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct of the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗