Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear chemistry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Electrochemical Detectors for Elemental Characterization of Actinides - 20563

The characterization of the actinides contained in radioactive waste involves complex and expensive separation processes. Electrochemical methods allow identifying and quantifying quickly and accurately the elementary concentration of actinides such as Th, U, Pu, Am, and Cm in liquid waste. The objective of this research proposal is to build a low-cost portable miniaturized electrochemical detector, which can be an alternative for an initial characterization of actinides in liquid waste. Therefore, this work proposes the use of an electrochemical graphite detector modified with phthalocyanine, to detect and quantify actinides in aqueous media. The electrochemical response of the modified graphite electrodes was performed by cyclic voltammetry, and so the detection and quantification limits for U and Th were determined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Partitioning upon Ammonia Gas Treatment on Phyllosilicate Minerals

In the past, > 200,000 kg of U was released to the Hanford Site vadose zone from disposal and leakage of waste byproducts from plutonium production during World War II and the Cold War (Zachara et al., 2007). U is highly mobile due to the presence of carbonates and oxidizing conditions, with K{sub d} of 0.1 - 8 mL/g at the site (Zachara et al., 2007; Szecsody et al., 2013; Serne et al., 2008). NH{sub 3} (gas) injection is being investigated as a remediation technique as it is an in situ method that will not introduce additional liquid that could drive contaminants deeper into vadose zone towards groundwater. Objectives: To understand the impact of alkaline injection on geochemical processes in the Hanford Site vadose zone, including: 1)Long-term fate of uranium (U); 2)Dissolution and re-precipitation of secondary minerals. Apparent K{sub d}'s increase significantly with NH{sub 3} gas treatment, especially for six-month aging. - K{sub d} decreases after aeration, primarily due to U desorption at lower pH. U removal is still significantly greater than natural conditions (K{sub d} < 8 vs. > 100 mL/g). - Three-day aeration has higher loading than six-month after ammonia gas treatment and aeration. However, significantly greater desorption of U occurs with aeration in the six-month aged sample potentially due to transformation into different, more soluble solid phases with longer term aging. - U removal is primarily due to (1) co-precipitation of U with secondary minerals and (2) adsorption to minerals' surface, although further research is required to identify dominant mechanisms. Future experiments will focus on garnering a better understanding of the solid phase U speciation. Solids will be characterized using SEM-EDS, EMPA, XPS, XAFS, and TEM to better understand the effects of basic treatments on initial minerals and formation of secondary precipitates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disulfonamide Ligands as f-Element Extractants from Alkaline High-Level Waste

Almost 100 million gallons of high level waste (HLW) has been generated from defense reprocessing programs to support nuclear weapons production. HLW is currently stored at the Hanford and Savannah River Sites (SRS) [1]. It contains radioactive components, such as {sup 137}Cs, {sup 99}Tc and {sup 90}Sr, as well as large amounts of non-radioactive species, including solvated cations and insoluble metal hydroxides. HLW has high concentration of soluble hydroxides ([OH{sup -}] = 2 M at SRS [2]), complexing inorganic anions ([NO{sub 3}{sup -}] ∼ 0.65 - 3.7 M at SRS [2]) and a high ionic strength. Even though the majority of actinide component in alkaline HLW is precipitated, studies of An(III) and Ln(III) complexation in highly alkaline solutions in the presence of high nitrate concentrations have showed that soluble nitrate complexes can be formed [3]. The current treatment of HLW at SRS currently consists of two processes: The Actinide Removal Process (ARP) and the Next-Generation Caustic-Side Solvent Extraction process (NG-CSSX). Strontium and actinides are removed by sorption on monosodium titanate through the Actinide Removal Process (ARP) commonly referred to as the alpha-strike step [4]. Then, cesium is selectively extracted from the alkaline media via the Caustic-Side Solvent Extraction (CSSX) process [5]. The CSSX solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix containing i) a solvent modifier (alkylphenoxy alcohol) which increases extractant solubility and prevents third phase formation, and ii) a suppressor (trioctylamine or guanidine) - that mitigates surfactant effects. The CSSX process removes {sup 137}Cs selectively and rapidly, yet the post- CSSX aqueous stream may still contain high amounts of An, thus requiring a second ARP treatment (referred to as 'alpha-finishing') for some tanks. Despite the success of the ARP process in removing Sr and An, it often represents the kinetic bottleneck of integrated processing, as it is slower than solvent extraction. Understanding the complexation of actinides by organic ligands that are compatible with the CSSX process could eventually lead to a combined caustic-side Cs/Sr/actinide extraction process with better economics due to a reduced amount of monosodium titanate and/or a shorter required contact time with titanate during ARP. This would ensure a low-activity waste (LAW) stream with no actinides without additional ARP processing post-CSSX. Disulfonamides were studied for extraction of Sm(III) from alkaline aqueous media of pH 10-14 into dichloromethane. Up to 82% of Sm(III) was extracted from solutions of pH 12.5 -13.5 and up to 84% from solutions of pH 10.5 - 11.5. These results show some resemblance with Am extraction results by calixarene ligands previously reported [10]. Kinetic studies demonstrated that even 5 min is enough to complete stripping, whereas extraction is time-limiting process and requires up to 20 h for efficient removal of Sm(III) from alkaline aqueous media. Determination of composition of complexes in solution after extraction by the equilibrium shift method showed a 1:1 Sm(III):dsa-2 complexation ratio for the extracted species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Isothermal oxidation of zirconium using steam

Oxidation of zirconium and its alloys under any atmosphere is generally characterised by a protective and non-protective stage. During the protective stage, the kinetics of oxidation are quasi-parabolic, while the oxide scale formed on the surface of the metal is black, compact, and protective in nature. For the non-protective stage, the oxidation rate becomes linear, while the protective oxide film turns into a deteriorated white scale. Breakaway is known as the transition point from protective to non-protective stage. The actual mechanism leading to breakaway of zirconium is still a matter of controversy, however some of the most common factors affecting breakaway are the following: - Impurities on the metal (Carbon, Oxygen, Nitrogen); - Oxidizing atmosphere (Presence of H{sub 2}O (g) or N{sub 2} (g)); - Sample preparation (Chemically etched or polished); - Temperature (LWR, LOCA). This research investigates the effect of temperature on 'breakaway' when zirconium is oxidized isothermally in steam for 60 min at 800 and 900 deg. C using thermogravimetric and optical microscopic imaging techniques. 1. Steam isothermal oxidations were performed on zirconium at 800 and 900 deg. C using a Thermogravimetric Analyzer (TGA). 2. Log-log plots of mass gain vs time were obtained from thermogravimetric results to calculate the reaction orders (n) and reaction rate constants (K) during oxidation. 3. Results of the kinetics of reaction were correlated with optical microscopic images form Light Microscope (LM) and Scanning Electron Microscope (SEM). Breakaway depends very strongly on temperature. At 800 deg. C, the weight gain followed a cubic-parabolic behaviour with evidence of a protective oxide film. On the other hand, oxidation at 900 deg. C showed signs of breakaway since the oxide film was cracked and oxidation rate was almost linear throughout the reaction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 90: US DOE Mixed Waste: Proposals for Dealing with Problematic Waste Streams and Policy Changes

This panel focused on generation and management of low level and mixed low-level radioactive wastes, challenges for disposition, innovative solutions applied at DOE sites, and collaboration among sites to ensure that waste disposition pathways are understood. In addition, potential policy initiatives were discussed including depleted uranium, elemental mercury, and treatment of legacy mixed waste components. As part of the introduction, Theresa Kliczewski provided an overview of why this panel is relevant: problematic mixed waste streams still exist across the DOE cleanup complex. Theresa noted that the DOE EM Headquarters Office of Waste and Materials Management (EM-4.2), for which she is employed with, continues to work with the DOE cleanup sites on a path forward for these problematic mixed waste streams. As part of this effort, EM-4.2 requested that the Energy Facility Contractors Group (EFCOG) perform a review of all the DOE sites problematic mixed waste streams. Panelists with presentations: Challenging Waste Streams: Disposition of Depleted Uranium Oxide Conversion Product (Douglas Tonkay); EFCOG WMWG Challenging Waste Subgroup (Tammy Monday); Mercury Waste Challenges (John Wrapp); Legacy Large Mixed Waste Components (Kalli Shupe)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sorption of Anionic Iodine and Molybdenum to Multi-sorbing Barrier (MSB) Materials - 20030

A multi-sorbing barrier (MSB) material containing sodium bentonite (NaB), organoclay, and anion resin is being evaluated for containment of anionic radionuclides. Batch tests on the MSB were conducted using two non-radioactive analog isotopes ({sup 127}I, {sup 95}Mo) as surrogates for {sup 129}I and {sup 99}Tc due to their similar valence and molecular weight relative to the radionuclides. Tests were conducted on the organoclay, anion resin, and NaB individually and on NaB-resin blends with resin contents of 1% and 5% by mass. The anion resin exhibits very strong sorption of {sup 127}I and {sup 95}Mo relative to the other materials. The organoclay exhibited modest sorption of {sup 95}Mo and {sup 127}I, and NaB little sorption. The sorption isotherms follow a linear model for NaB, a Freundlich model for the organoclay, and a Langmuir model for the anion resin and NaB-resin mixtures. Combining resin with NaB significantly enhances sorption relative to NaB alone, with a larger resin fraction yielding greater sorption. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Sorption Behavior of Europium to Calcium Silicate Hydrate by Thermal Analysis - 20172

High-level radioactive waste generated from reprocessing processes will be disposed in a geological disposal that is deep underground. Calcium silicate hydrate is formed as a secondary mineral in the repository via the reaction of calcium ions leaching from the cement and the silicic acid dissolved from the host rocks. In this study, the sorption behavior of europium, which is also known as a chemical analog of americium, on calcium silicate hydrate was examined. The solid phase was analyzed via thermogravimetry- differential thermal analysis, differential scanning calorimetry, Raman spectroscopy, fluorescence spectroscopy, and fluorescence lifetime analysis. To understand the behavior of calcium silicate hydrate under conditions saturated with groundwater, the study samples were analyzed using the above methods, except for deferential scanning calorimetry, without a drying process. The results of the differential scanning calorimetry analyses showed that the temperatures for the endothermic peaks of calcium silicate hydrate for the lower Ca/Si ratios were larger than those for the higher Ca/Si ratios for coexistent conditions of europium ions. Hence, the relationships of the temperatures of the endothermic peaks and the Ca/Si ratios were reversed by the addition of europium ions. These study results suggest that calcium silicate hydrate can immobilize europium ions, thus preventing the production of colloidal forms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyrolysis of Radioactive Spent Resins in the PRIME Installation - 20190

Montair and Belgoprocess developed the pilot PRIME (Pyrolysis Resins In Mobile Electric) Installation for treatment of spent resins in one single reactor without pre-treatment and without intermixing of other waste, allowing for easy traceability and isotopic characterization of the end product. Both low level waste (LLW, < 2 mSv/h) and medium level waste (MLW, > 2 mSv/h) can be treated in the installation. The PRIME pilot installation is designed to treat 2 batches of 100 liter of saturated ion exchange resins over a period of 24 hours. A dosing unit with screw feeder is used for the dosing of the saturated ion exchange resins to the pyrolysis reactor. This completely new developed innovative pyrolysis reactor contains a special design mechanical stirrer and can operate at a temperature of up to 600 deg. C under inert conditions. As a result, the organic molecules will decompose at an accelerated rate until only the mineralized material remains. The lower temperature and the absence of oxygen also prevent the breakdown of ion exchange resins into (powdery) ash, which is a considerable advantage during further handling. Gases that are released during drying and pyrolysis are treated in an also newly developed thermal oxidizer, which uses an innovative, electrically heated design instead of a traditional natural gas- or fuel oil secondary combustion chamber design. After passing through the thermal oxidizer, the gases are cooled down to saturation temperature and treated in the wet scrubbing system. An extraction fan keeps the system under negative pressure to prevent the possibility of any off-gas leakage out of the system. A series of tests were performed successfully with wet cationic resins, anionic resins and a mixture of both. The results of these tests are described in the presentation. For intellectual property protection, the system and process of pyrolysis of organic waste and the system of thermal oxidation of pyrolysis gases described in this paper are patent pending. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Use of Silver Chloride Injection in Remediation of Iodine-129 by In Situ Capture as Silver Iodide at the F-Area Seepage Basin - 20225

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. As part of operations, the F-Area Seepage Basins operated until 1988 for the disposition of deionized acidic wastewater from the F Separations Facility. The wastewater contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The seepage basins were closed in 1988 and backfilled and capped by 1991. The groundwater emanating from beneath the closed and capped seepage basins is acidic and contains elevated levels of both chemical and radiological contaminants. Releases from the groundwater plumes sourced from the F-Area Seepage Basins have impacted the water quality of Fourmile Branch, which is a small tributary to the Savannah River, a regional water source. A large pump-and-treat system was constructed in 1997 and operated until 2003 in an attempt to capture the releases to Fourmile Branch. The system in F Area and a similar system in H Area were expensive (∼$1.3 M/month) to operate and produced large quantities of radioactive waste, with concentrations of I- 129 too high to be disposed of at the SRS. In 2004, SRS replaced pump-and-treat with a funnel and gate system that along with operation of a base injection system at the gates reduces the flux of contaminants to the wetlands adjacent to Fourmile Branch. The alkaline solution injected into the aquifer neutralizes the acidic plume and immobilizes many of the cationic constituents. However, base injection is not effective in managing the release of iodine-129, an anionic contaminant. To address iodine-129 SRS and the Savannah River National Laboratory developed an in situ technology that uses ultra-fine ground silver chloride (AgCl) as an injectable capture medium for the sequestration of iodine-129. The AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture iodine-129. Dissolved iodine-129 forms a stable and highly insoluble solid (silver iodide) upon contact with AgCl. Laboratory studies, a field scale pilot test (2009), and three deployments (2011, 2015 and 2019) of AgCl have been successfully performed at the F-Area Seepage Basins. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Guidance for the Disposition of Used Oil and Oil Samples at the Columbia Generating Station - 20232

It is a fact that oil can become contaminated during plant operations. When used oil is collected, the water is decanted from the used oil. The separated used oil is typically analyzed for gamma emitting radionuclides and then sent off-site for processing (incineration) or recycling. If there is no detectable radioactivity, then some plants may release the oil for unrestricted use. Many nuclear power plants have no standard process for evaluating Tritium and Carbon-14 in oil; therefore, there may be variability in how plants are determining whether oil contains Tritium and Carbon-14, and at what concentration. Questions may arise whether there is a technically sound basis and evaluation method for used oil and if process knowledge and/or sampling may be appropriate in making that determination. Recently, there has been an increase in regulatory scrutiny regarding these practices to ensure that the utilities are evaluating oil for all plant-produced radionuclides prior to free release. Regulators have indicated that the requirement to conduct adequate surveys should include evaluating oils for Tritium and Carbon-14. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Assessment for Radioiodine at the Hanford Site - 20240

An evaluation was conducted to assess the practicability of technologies of sufficient promise and maturity to warrant treatability tests for remediating radioiodine (I-129) in groundwater at the 200-UP-1 operable unit at the U.S. Department of Energy Hanford Site. Technologies were evaluated based on recent updated knowledge of subsurface iodine transport behavior at Hanford, and the effectiveness, implementability, and cost of potential treatment technologies for I-129. Because more than two-thirds of the iodine at Hanford is estimated to be present in its oxidized form as iodate, treatment technologies were evaluated with respect to addressing iodate. In situ treatments were identified as having limited implementability because the plume core is located directly beneath the Environmental Restoration Disposal Facility disposal cells, a landfill used for the disposal of low-level radioactive, hazardous, and mixed wastes generated from Hanford cleanup activities. Further limitations in treatment technologies for radioiodine were due to the isotopic distribution of subsurface iodine. Data indicate that stable iodine (I- 127) concentrations are up to three orders of magnitude greater than I-129, limiting the effectiveness of potential technologies because they are not isotope-specific. Ex situ approaches also lacked the effectiveness and maturity required to treat I-129. Hence, the technology evaluation did not identify any technologies that needed treatability testing, driven by site and contaminant properties that hinder effectiveness and/or implementability of the technologies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation into Reductive Separation of Tc-99 from Low Activity Waste Off-Gas Condensate by Zero Valent Iron Materials - 20311

This study is investigating the potential for reductive separation of technetium-99 (Tc) from off-gas condensate generated from vitrification of legacy tank waste at the Hanford Tank Waste Treatment and Immobilization Plant. Management of Tc is a high-priority activity for the U.S. Department of Energy (DOE) Office of Environmental Management (EM) complex, which must be addressed based on knowledge gaps and technology development needs outlined in the DOE-EM Technetium Management Program Plan [1]. Technetium is one of the main risk drivers in the permanent disposal of low activity waste (LAW) by vitrification at the Hanford Site due to its high volatility and only fractional incorporation into borosilicate glass. Volatilized Tc will be captured by an off-gas treatment system, and the current plan is to continuously recycle generated condensate back to the LAW glass melter feed. Off-gas recycling is effective at increasing Tc loading in the LAW glass, but it also disproportionately increases concentrations of sulfate, halides, and other volatile compounds impeding overall LAW processing leading to significantly greater waste glass volume requirements. Removal of Tc from secondary liquid waste offers an alternative disposal route to continuous off-gas recycling which may result in significant reduction of the volumes of LAW waste glass and substantial cost savings. The objective of this research funded by the DOE-EM Minority Serving Institutions Partnership Program (MSIPP) is to determine the suitability of zero valent iron (ZVI) as a separation technology to remove Tc from the off-gas condensate stream to minimize its recycle. While ZVI has been proposed for various remediation applications with Tc, it has not been studied for its suitability for removing Tc from the LAW off-gas condensate. The goal is to identify the optimal conditions for which Tc{sup (VII)} will be reduced to Tc{sup (IV)} species and incorporated into an iron matrix. This paper presents a programmatic overview of our evaluation of commercial ZVI materials for their efficiency towards Tc{sup (VII)} reductive removal from simplified off-gas simulant solutions under aerobic conditions. Tc concentrations in solutions were monitored for up to 30 days to determine efficiency and kinetics of reductive removal of Tc. The best performing candidate materials were selected for further experiments evaluating the effects of (1) variable ionic strength, (2) the presence of chromium and corrosive anions, and (3) ZVI aging on Tc{sup (VII)} reductive removal in batch experiments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of He Ion Irradiation in Simple Borosilicate Glasses for HLW Immobilisation - 20324

High-level radioactive waste (HLW) consists of fission products and minor actinides. Borosilicate glass is the host material of choice in most countries to safely immobilize HLW, followed by eventual geological disposal. HLW glasses will experience both self-heating and self-irradiation effects due to the decay of fission products and minor actinides present therein. During the first 500 years of geological disposal, beta-gamma decay will be the main source of radiation due to short half-lives of fission products, as compared to very long-lived actinides which will be responsible for irradiation over much longer timescales. High-energy alpha particles and alpha recoil nuclei can potentially have significant impact (stored energy, volume change, accumulated dose, chemical durability) on the performance of the wasteform over longer timescales. Thus, to ensure safe and economic disposal over geological periods (10{sup 4} - 10{sup 6} years), the assessment of performance and properties in terms of radiation effects becomes indispensable. This work aims to simulate the effects of alpha decay in radioactive waste glasses. Two international glasses, namely UK 'MW' lithium-sodium borosilicate and Indian sodium-barium borosilicate, which are being used as HLW immobilization matrices by the UK and India respectively, were prepared by a melt-quench method and annealed below their glass transition temperatures. Both glasses were irradiated with 650 KeV He{sup 2+} ions with doses ranging from 10{sup 15} to 10{sup 17} ions/cm{sup 2}. Structural analysis was carried out using electron paramagnetic resonance (EPR) and Raman spectroscopies. First derivative continuous wave EPR spectra were recorded for all pristine and irradiated glass monoliths at room temperature using an X-band (frequency 9.6 GHz) EPR Bruker spectrometer. Results from EPR analyses showed the formation of irradiation induced paramagnetic centers at g ∼ 2.00 in all irradiated glasses. Raman spectra of pristine and irradiated samples were acquired, and showed notable changes in glass structure post-irradiation, with the emergence of a broad Raman band at 1560 cm{sup -1} upon irradiation with high fluences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗