Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Ringed Structures of the HD 163296 Protoplanetary Disk Revealed by ALMA

We present Atacama Large Millimeter and Submillimeter Array observations of the protoplanetary disk around the Herbig Ae star HD 163296 that trace the spatial distribution of millimeter-sized particles and cold molecular gas on spatial scales as small as 25 astronomical units (A.U.). The image of the disk recorded in the 1.3 mm continuum emission reveals three dark concentric rings that indicate the presence of dust depleted gaps at about 60, 100, and 160 A.U. from the central star. The maps of the 12 CO, 13 CO, and C 18 O J = 2 - 1 emission do not show such structures but reveal a change in the slope of the radial intensity profile across the positions of the dark rings in the continuum image. By comparing the observations with theoretical models for the disk emission, we find that the density of CO molecules is reduced inside the middle and outer dust gaps. However, in the inner ring there is no evidence of CO depletion. From the measurements of the dust and gas densities, we deduce that the gas-to-dust ratio varies across the disk and, in particular, it increases by at least a factor 5 within the inner dust gap compared to adjacent regions of the disk. The depletion of both dust and gas suggests that the middle and outer rings could be due to the gravitational torque exerted by two Saturn-mass planets orbiting at 100 and 160 A.U. from the star. On the other hand, the inner dust gap could result from dust accumulation at the edge of a magnetorotational instability dead zone, or from dust opacity variations at the edge of the CO frost line. Observations of the dust emission at higher angular resolution and of molecules that probe dense gas are required to establish more precisely the origins of the dark rings observed in the HD 163296 disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronic Population Transfer via Impulsive Stimulated X-Ray Raman Scattering with Attosecond Soft-X-Ray Pulses

Free electron lasers provide a source of X-ray pulses short enough and intense enough to drive nonlinearities in molecular systems. Impulsive interactions driven by these X-ray pulses provide a way to create and probe valence electron motions with high temporal and spatial resolution. Observing these electronic motions is crucial to understand the role of electronic coherence in chemical processes. A simple nonlinear technique for probing electronic motion, impulsive stimulated X-ray Raman scattering (ISXRS), involves a single impulsive interaction to produce a coherent superposition of electronic states. In this work, we demonstrate electronic population transfer via ISXRS using broad bandwidth (5.5 eV full width at half maximum) attosecond X-ray pulses produced by the Linac Coherent Light Source (LCLS). The impulsive excitation is resonantly enhanced by the oxygen 1s → 2π* resonance of nitric oxide (NO), and excited state neutral molecules are probed with a time-delayed UV laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Correlated Double-Electron Additions at the Edge of a Two-Dimensional Electronic System

We create laterally large and low-disorder GaAs quantum-well-based quantum dots that act as small two-dimensional electron systems. We monitor tunneling of single electrons to the dots by means of capacitance measurements and identify single-electron capacitance peaks in the addition spectrum from occupancies of one up to thousands of electrons. The data show two remarkable phenomena in the Landau level filling factor range ν = 2 to ν = 5 in selective probing of the edge states of the dot: (i) Coulomb blockade peaks arise from the entrance of two electrons rather than one; (ii) at and near ν = 5/2 and at fixed gate voltage, these double-height peaks appear uniformly in a magnetic field with a flux periodicity of h/2e, but they group into pairs at other filling factors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The Quantum Instrumentation Control Kit (QICK) is a standalone open-source qubit controller that was first introduced in 2022. In this follow-up work, we present recent upgrades to the QICK and the experimental use cases they uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, predistorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical conductivity study of mixed-valent quasi-one-dimensional CeIr 3 ⁢B 2

Here, we present a combined theoretical and experimental study on the optical conductivity of CeIr 3 ⁢B 2 , where quasi-one-dimensional Ce chains form along the 𝑐 axis of the monoclinic crystal. Significant hybridization-induced features are observed along the Ce chains by broadband infrared spectroscopy, demonstrating mixed-valent behavior over a wide range of temperatures (6–300 K) and energies (up to 0.8 eV). The ferromagnetic transition at 41 K had no noticeable influence on the temperature evolution of the optical conductivity. A comparison with density functional theory plus dynamic mean-field theory calculations demonstrates the quasi-one-dimensional nature of CeIr 3 ⁢B 2 and the local character of the interactions responsible for the electronic renormalization. Furthermore, we demonstrate how the spectroscopic signatures of this mixed-valent compound are captured by theory, providing a clear distinction from the response expected in the integer-valent Kondo regime.

36 MATERIALS SCIENCE↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

The Effect of Clean Energy Generation Targets on the Portfolio of Electric Grid Generation Technologies

A least-cost generation and transmission expansion planning model is used to optimize the U.S. generation portfolio in 2030 under a range of Clean Energy Generation Target (CEGT) policy goals. As reference cases for comparison, the model is used to optimize the generation portfolio for the future electric grid with and without the Investment and Production Tax Credits (ITC and PTC). Next, the model is used to optimize the generation portfolio with a CEGT ranging from 10% to 70%. The results show that due to the ITC and PTC extensions by the 2022 Inflation Reduction Act, there is little additional investment in renewable energy generation assets at low CEGT levels. Significant additional installations of both renewable energy generation and energy storage systems – both batteries and pumped storage hydro – become important at CEGT levels above approximately 30%.

Aldeman, Matthew↗

Advancements in NbTiN based circuits for Superconducting Digital Logic

Superconducting (SC) electronics have emerged as a promising platform for high-speed, energy-efficient computing and quantum information processing. This work, centered on NbTiN, presents recent advances in material science and fabrication methods leading to significant improvements in performance, scalability and vertical integration. We specifically report on fabrication and characterization of key components, including Josephson junctions (JJs), flux trapping structures and SC interconnects. Together, these efforts represent critical steps towards realizing practical, complex, dense and large-scale SC integrated circuits.

Pokhrel, A. [Imec,Heverlee,Belgium]↗

Characterization of Field-Exposed Photovoltaic Modules Featuring Signs of Contact Degradation

Here, this work investigates several photovoltaic (PV) modules that have shown signs of metal contact corrosion due to field exposure in a hot and humid climate. This includes two multicrystalline silicon aluminum back surface field systems with 10 and 14 years of exposure and one monocrystalline silicon passivated emitter and rear cell system with four years of exposure. A comprehensive, multiscale characterization process is used to evaluate these PV modules in great detail. Current–voltage (I−V), Suns-V OC measurements, electroluminescence imaging, infrared imaging, and ultraviolet fluorescence imaging were performed, and locations of interest were cored and analyzed using cross-sectional scanning electron microscopy (SEM). A rigorous, quantitative analysis procedure for the cross-sectional SEM images is proposed and implemented. Careful characterization does reveal that some of these PV modules do indeed exhibit the same classic signs of acetic-acid-based corrosion of the glass frit that is present at the silver/silicon interface, which have been observed previously in PV modules exposed to damp heat in an environmental chamber.

14 SOLAR ENERGY↗

Micromachined Piezoresistive-sensed Diaphragms for Infrasonic Monitoring

Micromachined, piezoresistive-sensed diaphragms are designed and fabricated specifically for infrasound sensing applications. Relatively large diaphragms, up to 6 mm × 6 mm, are fabricated to meet the high sensitivity requirements of infrasonic monitoring. A double-stack SOI wafer process is used, resulting in a streamlined two-mask process without the need for doping or ion-implantation. Pressure-sensitivities of diaphragms are studied using a custom static calibration set-up. Here, the piezoresistance of longitudinal and transverse resistors are studied over a large pressure range of ±5,500 Pa so that the linear and nonlinear response regions of diaphragms are observed. Measurements are compared against a nonlinear finite element simulation—shown to accurately predict the sensor’s behavior over a large response range.

47 OTHER INSTRUMENTATION↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Beta Radiation Hardness of GYGAG(Ce) Transparent Ceramic Scintillators

GYGAG(Ce) transparent ceramic garnet scintillators were irradiated with electrons from 0.5 to 2 MeV with fluences from 10 16 e – /cm 2 to 10 19 e – /cm 2 , corresponding to doses from 0.3 to 310 Gigarad. Absorption spectra were measured before and after irradiations. Light yields from alpha, beta, and gamma excitations were measured before and after irradiation and compared to preirradiation values to gain a deeper understanding of how electron irradiations can affect light yield, as well as defects generated in both the surface and bulk. Within experimental error, no degradation in light yield was observed for the electron-irradiated samples, as measured via beta or gamma excitation, with minimal degradation observed via alpha excitation. A small increase in optical absorption near the wavelength of emission was observed following the largest dose irradiation. These results suggest that GYGAG(Ce) is radiation hard to electron irradiation up to 10 19 e – /cm 2 and doses up to 310 Gigarad. Furthermore, this robustness to irradiation indicates that transparent ceramic garnets may prove useful for applications such as scintillation-based nuclear batteries by allowing for higher energy beta emitters, increased power densities, and enabling long service lifetimes.

36 MATERIALS SCIENCE↗

Silicon Photomultipliers Coupled to Scintillators With the Emission Maximum at 550 nm

A majority of the silicon photomultipliers (SiPMs) are sensitive to blue and near-ultraviolet (NUV) photons that are not optimized for scintillators with the emission maximum at wavelengths longer than 500 nm. The red–green–blue (RGB) SiPM is developed for the maximum photon detection efficiency (PDE) at 550 nm, which is a good match for some high-light-yield scintillators, such as CsI:Tl (CsI) and Gd 1.5 Y 1.5 Ga 2 Al 3 O 12 :Ce (GYGAG). Comparisons are made for the performance of these scintillators coupled to the RGB SiPM and a blue-sensitive SiPM. Because it takes tens of nanoseconds for the microcells to recharge after registering a photon hit, the linearity of these scintillation detectors was studied for high-energy gammas where numerous scintillation photons are generated. In addition, the energy resolution of the 662-keV gamma emitted by 137 Cs was measured for temperatures between –20 °C and 50 °C. The nonlinearity was observed above 1 MeV for all measurements, and however, it can be corrected by energy calibration using a third-degree polynomial. For CsI, the energy resolution is better with the blue-sensitive SiPM because of the lower dark count rate (DCR). In contrast, GYGAG coupled to the RGB SiPM has a better energy resolution for temperatures below 30 °C because of the well-matched emission spectrum and PDE distribution. Nevertheless, the advantage disappears for temperatures above 30 °C due to the higher DCR. It would be useful to further develop the RGB SiPM with a lower DCR and higher operating temperatures.

42 ENGINEERING↗