Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Study of a Proposed fissionTPC Measurement of 233 U(n,f)/ 235 U(n,f) Cross Section Ratio

A review of the available 233 U( n, f )/ 235 U( n, f ) cross section ratio data compared to the ENDF evaluation in the fast neutron energy range, 0.1–20 MeV, shows that discrepancies exist between some of the various measurements and the evaluation. The discrepancies vary and a function of incident neutron energy and range between 1–5%. In this document we review two potential options for performing new measurements of the cross section ratio to potentially resolve these discrepancies. The two options are compared and contrasted in terms of measurement accuracy and cost. The first option would utilize the fissionTPC, which was designed specifically to achieve measurement uncertainties of better than 1% to resolve a similar data–evaluation discrepancy in the 239 Pu( n, f ) cross section. While this would seem to be an ideal option in this case also, there are challenges. The fissionTPC is a complex instrument and the cost of maintenance and operations are significant. Furthermore, some of the fissionTPC equipment is nearing the end of its useful life which presents a risk to completion of a measurement campaign. The second option is to use a dual-fission chamber, which is the more traditional approach to these types of measurements. The cost is estimated to be about half that of a fissionTPC measurement, while the much simpler design of the detector reduces overall risk. The trade-off is the measurement uncertainty, which would be on order of 1–3% with a careful measurement and analysis. This uncertainty however may not be good enough to fully resolve the discrepancies. The objective of a new measurement would be the improvement in the ENDF evaluation with the end goal of improving the accuracy of models and simulations at the end of the nuclear data pipeline. An understanding of the sensitivity of these models to the data uncertainties would help guide the choice of measurement techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANL/LLNL 240 Pu( n,f ) Prompt Fission Neutron Spectrum Measurement (Q4 FY2022 Progress Report)

The report details the joint LANL/LLNL measurement of the 240 Pu( n,f ) prompt fission neutron spectrum (PFNS) for incident neutron energies from 1–20 MeV. A summary of the experimental setup, including details of the parallel-plate avalanche counter (PPAC) used for this experiment, beam time awarded and received, and adaptations made for specifically for this experiment are described in Sec. II. Some preliminary results obtained with a portion of the total available statistics from the executed experiment are then described in Sec. III with a discussion of potential benefits and losses if more data were collected. Finally, some primary tasks remaining to convert these data to final results are discussed in Sec. IV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools: Case Studies of U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2 [References 3-5]. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. An initial comparison involved four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been documented in References 10-13. This study extends the comparison to include cases U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM- 004-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hands-On Experimental Training [Slides]

Training provided includes: Nuclear Criticality Safety Fundamentals, Sub-Critical "Hands On" Demonstration, Hand-Stacking and Remote Approach to Critical Using the Planet Assembly, Flattop Free-Run Demonstration, and Godiva-IV Critical Assembly Demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Producing ENDF/B-quality Evaluations of 239 Pu(n,f) and 235 U(n,f) Average Prompt Neutron Multiplicities using the CGMF Model

This report documents evaluations of the neutron-induced 239 Pu and 235 U average prompt neutron multiplicities, $\overline{v}_p$, using the CGMF model developed at LANL. These evaluations are not updates of existing ENDF/B-VIII.0 nuclear data, but were both re-done from "scratch". That is, all experimental data were extracted from EXFOR, re-normalized to the newest nuclear data representing monitor observables, and detailed uncertainties were estimated from information in EXFOR as well as from templates of expected measurement uncertainties. We also included experimental data that were not yet available for ENDF/B-VIII.0, for instance, the data of Marini et al. for 239 Pu(n,f) $\overline{v}_p$ or the data of Khoklov et al. for 235 U(n,f) $\overline{v}_p$. Finally, we include the CGMF model; it computes $\overline{v}_p$ based on model parameters that at the same time calculate fission fragments as a function of mass, Y (A), the average total kinetic energy as a function of incident-neutron energy, $\langle TKE \rangle$(E inc ), etc. Such a detailed fission model that ties together many fission quantities has not been used to date for any $\overline{v}_p$ evaluation in ENDF/B. Here, we show that we can get evaluated 235 U(n,f) and 239 Pu $\overline{v}_p$ that not only correspond well to experimental $\overline{v}_p$, but that the associated evaluated model parameters also yield parameterizations of Y (A), $\langle TKE \rangle$(E inc ), etc., that correspond well to their respective experimental data. The new evaluated 239 Pu(n,f) $\overline{v}_p$ was also combined into a 239 Pu test file with the newest nuclear data for the 239 Pu prompt-fission neutron spectrum and fission cross sections. This new 239 Pu file performed reasonably well in predicting PU-MET-FAST assemblies, reaction rates in Jezebel and Flattop and three LLNL pulsed spheres. Due to that, the new 239 Pu(n,f) $\overline{v}_p$ evaluation presented here is being considered for ENDF/B-VIII.1. Hence, we can show here that CGMF is able to produce ENDF/B quality $\overline{v}_p$ nuclear data.

239Pu, 235U, Average Prompt-fission Neutron Multip↗

Nondestructive Assay Technical Infrastructure Program Mission and Vision

The Nondestructive Assay Program (NDAP) mission and vision is achieved by identifying and accomplishing a set of programmatic goals that correspond with eight broad technical program elements. The NDAP was created as a result of Defense Nuclear Facility Safety Board Recommendation 2007-1, entitled “Safety-Related In Situ Nondestructive Assay of Radioactive Materials,” which emphasized the need to improve in situ measurements of radioactive material at US Department of Energy (DOE) defense nuclear facilities. An NDAP five-year plan will define tasks to accomplish specific goals identified in the NDAP mission and vision. This mission and vision is applicable for eight technical program elements: Hardware/Software Development, Algorithm Development and Nuclear Data, Uncertainty Quantification, Nuclear Materials, Staffing, Personnel, And Training, Data Management, Requirement and Standards, and Information Preservation and Dissemination. An additional program element is technical support, which provides daily execution management support for the NDAP, site scope, and deliverable tracking via site task managers, along with technical advisement and support from the technical support group. The NDAP mission and vision provides attributes with specific goals for each program element, and some goals benefit multiple program elements. The goals and attributes defined herein are implemented via an NDAP five-year execution plan that defines site work scope, budget, and deliverables, all of which are updated annually. The NDAP is designed to benefit nondestructive assay (NDA) needs to support DOE nuclear criticality safety programs, ensuring that NDA technology is sufficiently capable of guaranteeing the safety of those who handle, store, process, or transport fissionable materials in the complex. Especially important for the NDAP is to maximize capabilities to identify, characterize, and manage in situ fissile material deposits in process equipment to ensure nuclear criticality safety at processing facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data? [Slides]

Importance of nuclear data to bias changed significantly when including diverse measurement sets. LLNL pulsed sphere measurements provided information for 9 Be nuclear data above 2 MeV and subcritical benchmarks provided information for 240 Pu nuclear data between 100 keV and 10 MeV. Pulsed sphere leakage spectra and neutron noise observables are differently sensitive to nuclear data compared to critical benchmarks. Leakage spectra are sensitive to nuclear data above 5 MeV. Count rate and Feynman Y are more sensitive to nuclear data. A change in bias can help evaluators identify discrepant nuclear data. In the future, EUCLID plans to perform RAFIEKI analysis with additional benchmark and measurement sets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of URR Implementations in GNDS Format [Slides]

LLNL implemented infrastructure to include treatment of URR in GNDS. There are two options to store URR probabilities: cross-sections pdf and ACE-like probability tables. Issues were found with both options during verification with criticality benchmarks. Projected future steps include resolving issues in the next year and adding criticality benchmarks sensitive to URR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The History of Monte Carlo and MCNP at Los Alamos [Slides]

The Monte Carlo method for radiation particle transport has its origins at LANL dating back to the 1940’s. The creators of these methods were Drs. Stanislaw Ulam, John von Neumann, Robert Richtmyer, and Nicholas Metropolis. Monte Carlo methods for particle transport have been driving computational developments since the beginning of modern computers; this continues today. In the 1950’s and 1960’s, these new methods were organized into a series of special-purpose Monte Carlo codes, including MCS, MCN, MCP, and MCG. These codes were able to transport neutrons and photons for specialized LANL applications. In 1977, these separate codes were combined to create the LANL Monte Carlo N-Particle (MCNP) radiation particle transport code. In 1983, MCNP3 was released for public distribution to the Radiation Safety Information Computational Center (RSICC). MCNP6.3 will be released late in 2021. Each year, LANL has ~100 MCNP new users and RSICC ~1250 new licenses distributed. This talk will review the Los Alamos history of the development of the modern Monte Carlo method and MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Questionable Benchmarks [Slides]

An investigation and initial review of ‘questionable benchmarks’ was performed at LANL. Multiple methods were used, including machine learning techniques, to identify 'questionable benchmarks' and/or benchmarks with low uncertainties. Those benchmarks were then reviewed for obvious errors. This is not a recommendation to ICSBEP, but can be used as a starting point for a more comprehensive review. A journal paper is being written on this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a New Fixed-source Sensitivity Tally Capability in the MCNP ® Code [Slides]

Current work includes FSEN capability development, continued verification of adjoint-weighted sensitivity method, and improvement of algorithm speed and parallelism capability. Future work is forecasted to include extensions to non-Boltzmann responses, adding more responses and particle types, and connection to new MCNP6.3 tally backend.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗