Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Daily Satellite Observations of Methane from Oil and Gas Production Regions in the United States

Production of oil and natural gas in North America is at an all-time high due to the development and use of horizontal drilling and hydraulic fracturing. Methane emissions associated with this industrial activity are a concern because of the contribution to climate radiative forcing. We present new measurements from the space-based TROPOspheric Monitoring Instrument (TROPOMI) launched in 2017 that show methane enhancements over production regions in the United States. In the Uintah Basin in Utah, TROPOMI methane columns correlated with in-situ measurements, and the highest columns were observed over the deepest parts of the basin, consistent with the accumulation of emissions underneath inversions. In the Permian Basin in Texas and New Mexico, methane columns showed maxima over regions with the highest natural gas production and were correlated with nitrogen-dioxide columns at a ratio that is consistent with results from in-situ airborne measurements. The improved detail provided by TROPOMI will likely enable the timely monitoring from space of methane emissions associated with oil and natural gas production.

54 ENVIRONMENTAL SCIENCES↗

Optimal choice of multiple line-of-sight measurements determining plasma hotspot velocity at the National Ignition Facility

The measurement of plasma hotspot velocity provides an important diagnostic of implosion performance for inertial confinement fusion experiments at the National Ignition Facility. The shift of the fusion product neutron mean kinetic energy as measured along multiple line-of-sight time-of-flight spectrometers provides velocity vector components from which the hotspot velocity is inferred. Multiple measurements improve the hotspot velocity inference; however, practical considerations of available space, operational overhead, and instrumentation costs limit the number of possible line-of-sight measurements. Here, we propose a solution to this classical “experiment design” problem that optimizes the precision of the velocity inference for a limited number of measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-cost, constrained-motion dynamometer for milling force measurement

This paper describes the design and testing of a low-cost dynamometer for milling force measurement. The monolithic design is based on constrained-motion/flexure-based kinematics, where force is inferred from displacement measured using a low-cost optical interrupter (i.e., a knife edge that partially interrupts the beam in an emitter-detector pair). The time-dependent displacement of the dynamometer’s moving platform caused by the milling force is converted to the frequency domain, multiplied by the inverse of the single degree of freedom frequency response, and converted back to the time domain to obtain the time dependent cutting force. Lastly, comparisons with commercially available, piezoelectric-based force measurement are provided.

47 OTHER INSTRUMENTATION↗

On the measurement of hardness at high strain rates by nanoindentation impact testing

Recent advances in electronics have enabled nanomechanical measurements with very low noise, fast time constants and high data acquisition rates. Furthermore, these capabilities open the door for a wide range of ultra-fast nanomechanical testing. Given the inherent dynamic nature of high-speed testing, a thorough understanding of the testing system's dynamics and electronics is extremely important for accurate measurements. In this work, an analytical framework that includes the mechanical and electronic contributions of the instrument and the material constitutive response is presented to provide guidelines for performing high strain rate measurements of hardness by nanoindentation testing. Simple closed-form solutions that provide insights on the choice of test methodology, test parameters and instrument design are presented along with the strain rate range over which accurate measurements can be performed with the commercially available nanoindenters.

36 MATERIALS SCIENCE↗

Dynamical dark energy in light of the DESI DR2 baryonic acoustic oscillations measurements

Understanding whether cosmic acceleration arises from a cosmological constant or a dynamical component is a central goal of cosmology, and the Dark Energy Spectroscopic Instrument (DESI) enables stringent tests with high-precision distance measurements. Here we analyse measurements of baryon acoustic oscillations in DESI Data Release 1 and Data Release 2 and consider type Ia supernovae and a distance prior for the cosmic microwave background. With the larger statistical power and wider redshift coverage of Data Release 2, the preference for dynamical dark energy does not diminish relative to Data Release 1. Using both a shape-function reconstruction and non-parametric approaches with a Horndeski-motivated correlation prior, we find that the equation of state for dark energy w(z) varies with redshift. Baryon acoustic oscillation data alone yield modest constraints, but in combination with independent supernova compilations and the prior for the cosmic microwave background, they strengthen the evidence for dynamics. A Bayesian comparison of models shows moderate support for departures from Λ cold dark matter (ΛCDM) when several degrees of freedom in w(z) are allowed, corresponding to ~3σ tension with ΛCDM (and higher for some datasets). Despite methodological differences, our results are consistent with companion DESI papers, underscoring the complementarity of the approaches. Possible systematics remain under study; forthcoming DESI, Euclid and next-generation cosmic microwave background data will provide decisive tests.

cosmology↗

Dynamical dark energy in light of the DESI DR2 baryonic acoustic oscillations measurements

Understanding whether cosmic acceleration arises from a cosmological constant or a dynamical component is a central goal of cosmology, and the Dark Energy Spectroscopic Instrument (DESI) enables stringent tests with high-precision distance measurements. Here we analyse measurements of baryon acoustic oscillations in DESI Data Release 1 and Data Release 2 and consider type Ia supernovae and a distance prior for the cosmic microwave background. With the larger statistical power and wider redshift coverage of Data Release 2, the preference for dynamical dark energy does not diminish relative to Data Release 1. Using both a shape-function reconstruction and non-parametric approaches with a Horndeski-motivated correlation prior, we find that the equation of state for dark energy w(z) varies with redshift. Baryon acoustic oscillation data alone yield modest constraints, but in combination with independent supernova compilations and the prior for the cosmic microwave background, they strengthen the evidence for dynamics. A Bayesian comparison of models shows moderate support for departures from Λ cold dark matter (ΛCDM) when several degrees of freedom in w(z) are allowed, corresponding to ~3σ tension with ΛCDM (and higher for some datasets). Despite methodological differences, our results are consistent with companion DESI papers, underscoring the complementarity of the approaches. Possible systematics remain under study; forthcoming DESI, Euclid and next-generation cosmic microwave background data will provide decisive tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Scanning Mobility Particle Sizer (SMPS) Instrument Handbook

The Model 3936 Scanning Mobility Particle Spectrometer (SMPS) measures the size distribution of aerosols ranging from 10 nm up to 1000 nm. The SMPS uses a bipolar aerosol charger to keep particles within a known charge distribution. Charged particles are classified according to their electrical mobility, using a long-column differential mobility analyzer (DMA). Particle concentration is measured with a condensation particle counter (CPC). The SMPS is well-suited for applications including: nanoparticle research, atmospheric aerosol studies, pollution studies, smog chamber evaluations, engine exhaust and combustion studies, materials synthesis, filter efficiency testing, nucleation/condensation studies, and rapidly changing aerosol systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Soil moisture, physical and chemical properties coincident with airborne SAR data collections for 2017 and 2019, Seward Peninsula, Alaska

Soil samples were collected coincident with in-situ soil moisture and thaw depth measurements at NGEE Arctic study sites on the Seward Peninsula, Alaska in August 2017 and 2019 Field measurements and flights were conducted during both summers as a collaboration between the NASA ABoVE Project's Airborne SAR Campaign and the NGEE Arctic Project. Airborne overflights of L-band SAR instruments occurred during the soil sampling periods. Laboratory measurements of soil properties include bulk density, volumetric and gravimetric water content, carbon and nitrogen content, and particle size of mineral components. Soil samples processed and reported in this dataset were collected coincident with in situ measurements of soil moisture and thaw depth and airborne P-band and L-band SAR measurements as a collaboration between NGEE Arctic and NASA ABoVE. To learn more about how ABoVE protocols were applied for sampling site selection and making in situ measurements, see the following datasets: (2017: https://doi.org/10.5440/1423892 and 2019: https://doi.org/10.5440/1856042). Contained in this dataset are four .csv data files (including data dictionaries) and one zipped folder of *.pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort (with some overlap with Covid-19 pandemic) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of aircraft measurements during GoAmazon2014/5 and ACRIDICON-CHUVA

The indirect effect of atmospheric aerosol particles on the Earth's radiation balance remains one of the most uncertain components affecting climate change throughout the industrial period. The large uncertainty is partly due to the incomplete understanding of aerosol–cloud interactions. One objective of the GoAmazon2014/5 and the ACRIDICON (Aerosol, Cloud, Precipitation, and Radiation Interactions and Dynamics of Convective Cloud Systems)-CHUVA (Cloud Processes of the Main Precipitation Systems in Brazil) projects was to understand the influence of emissions from the tropical megacity of Manaus (Brazil) on the surrounding atmospheric environment of the rainforest and to investigate its role in the life cycle of convective clouds. During one of the intensive observation periods (IOPs) in the dry season from 1 September to 10 October 2014, comprehensive measurements of trace gases and aerosol properties were carried out at several ground sites. In a coordinated way, the advanced suites of sophisticated in situ instruments were deployed aboard both the US Department of Energy Gulfstream-1 (G1) aircraft and the German High Altitude and Long-Range Research Aircraft (HALO) during three coordinated flights on 9 and 21 September and 1 October. Here, we report on the comparison of measurements collected by the two aircraft during these three flights. Such comparisons are challenging but essential for assessing the data quality from the individual platforms and quantifying their uncertainty sources. Similar instruments mounted on the G1 and HALO collected vertical profile measurements of aerosol particle number concentrations and size distribution, cloud condensation nuclei concentrations, ozone and carbon monoxide mixing ratios, cloud droplet size distributions, and downward solar irradiance. We find that the above measurements from the two aircraft agreed within the measurement uncertainties. The relative fraction of the aerosol chemical composition measured by instruments on HALO agreed with the corresponding G1 data, although the total mass loadings only have a good agreement at high altitudes. Furthermore, possible causes of the discrepancies between measurements on the G1 and HALO are examined in this paper. Based on these results, criteria for meaningful aircraft measurement comparisons are discussed.

47 OTHER INSTRUMENTATION↗

Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for characterizing radiated noise from marine energy converters

Marine energy converters can generate electricity from energetic ocean waves and water currents. Because sound is extensively used by marine animals, the radiated noise from these systems is of regulatory interest. However, the energetic nature of these locations poses challenges for performing accurate passive acoustic measurements, particularly with stationary platforms. The Drifting Acoustic Instrumentation SYstem (DAISY) is a modular hydrophone recording system purpose-built for marine energy environments. Using a flow shield in currents and mass–spring–damper suspension system in waves, we demonstrate that DAISYs can effectively minimize the masking effect of flow noise at frequencies down to 10 Hz. In addition, we show that groups of DAISYs can utilize time-delay-of-arrival post-processing to attribute radiated noise to a specific source. Consequently, DAISYs can rapidly measure radiated noise at all frequencies of interest for prototype marine energy converters. Furthermore, the resulting information from future operational deployments should support regulatory decision-making and allow technology developers to make design adjustments that minimize the potential for acoustic impacts as their systems are scaled up for utility-scale power generation.

16 TIDAL AND WAVE POWER↗

Electric Field Data from the North Slope of Alaska

File contains raw as well as calibrated electric field values (V/m) from two CS110 electric field meters. The file also contains raw 2-m U and V winds at the same site. The sampling rate is 1Hz. All files contain raw electric field data, as well as calibrated values to a one week ground-based calibration setup. During this week, simultaneous upward-facing ground based electric field measurements were taken alongside the two downward facing instruments on the pole (CS110-3 at 2m and CS110-2 at 5m). Slopes and intercepts were calculated and applied to the values influenced by the pole to convert the raw data to calibrated values. These calibrated values are absolute electric field measurements. There are no missing data codes. The missong data is not included in the files, and thus any files with missing data will be shorter than the normal 86,400 values. In July 2023, the CS110-3 was replaced with an identical instrument named CS110-8, and the CS110-2 was replaced with an identical instrument called CS110-9. All the variable names remained consistent and the same.

54 ENVIRONMENTAL SCIENCES↗

dlppi2 (b1)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grain Growth and Coarsening Dynamics in a Compositionally Asymmetric Block Copolymer Revealed by X-ray Photon Correlation Spectroscopy

The dynamics of nanostructured soft materials crucially impact their associated macroscopic material properties, yet they are often difficult to measure due to spatiotemporal limitations of conventional instrumentation. Herein, we use X-ray photon correlation spectroscopy (XPCS) to directly observe particle-scale dynamics during grain growth and coarsening in a BCC- forming diblock polymer melt, with specific attention to the distribution of structural relaxation times associated with the interplanar (110) distance. Following sample quenching from the disordered state, these dynamical phenomena surprisingly exhibit little dependence on time and thermal quench depth. We posit that these relaxations stem from collective particle motions during grain rotation. We also observe unusual internally-referenced heterodyne correlations, which enable measurements of speed distributions within the sample. In this work, these speeds are significantly slower and appear at much longer annealing times than those previously reported during grain nucleation and growth in microphase separated block polymer melts. Drawing on analogies between polycrystalline hard and soft materials, we ascribe these speed distributions to misorientation-dependent grain boundary migration during ordered domain coarsening and anomalously fast, cooperative string-like particle motion along the grain boundaries. Thus, these coherent X-ray measurements provide new opportunities to interrogate grain boundary structure and dynamics in polycrystalline soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗