Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Spatial resolution in secondary-electron microscopy

Here, we first review the significance of resolution and contrast in electron microscopy, and the effect of the electron optics on these two quantities. We then outline the physics of the generation of secondary electrons (SE) and their transport and emission from the surface of a specimen. Contrast and resolution are discussed for different kinds of SE imaging in scanning (SEM) and scanning-transmission (STEM) instruments, with some emphasis on the observation of individual atoms and atomic columns in a thin specimen. The possibility of achieving atomic resolution from a bulk specimen at SEM energies is also considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct Probing of Radiolysis Chemistry in the Gas Cell Electron Microscopy

Here, the radiolytic decomposition of materials is inevitable in electron microscopy, alongside knock-on effects, electrical charging, and heating damage. Especially with the radiation-susceptible chemistry in the fluidic phase (liquid and gas), consideration of mitigating or leveraging these phenomena is particularly important.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Streaming Large-Scale Microscopy Data to a Supercomputing Facility

Data management is a critical component of modern experimental workflows. As data generation rates increase, transferring data from acquisition servers to processing servers via conventional file-based methods is becoming increasingly impractical. The 4D Camera at the National Center for Electron Microscopy generates data at a nominal rate of 480 Gbit s -1 (87,000 frames s -1 ⁠), producing a 700 GB dataset in 15 s. To address the challenges associated with storing and processing such quantities of data, we developed a streaming workflow that utilizes a high-speed network to connect the 4D Camera’s data acquisition system to supercomputing nodes at the National Energy Research Scientific Computing Center, bypassing intermediate file storage entirely. In this work, we demonstrate the effectiveness of our streaming pipeline in a production setting through an hour-long experiment that generated over 10 TB of raw data, yielding high-quality datasets suitable for advanced analyses. Additionally, we compare the efficacy of this streaming workflow against the conventional file-transfer workflow by conducting a postmortem analysis on historical data from experiments performed by real users. Our findings show that the streaming workflow significantly improves data turnaround time, enables real-time decision-making, and minimizes the potential for human error by eliminating manual user interactions.

4D-STEM↗

Towards Mitigating Electron Beam-Induced Damage in MOFs Using Low Dose Electron Microscopy for In-Situ Room-Temperature Measurements

Metal-Organic Frameworks (MOFs) have emerged as a versatile class of materials with applications in gas storage and separation, catalysis, and drug delivery [1]. Understanding their damage mechanisms in under various environmental conditions is crucial for optimizing performance and stability [2]. This study employs a combination of Length Structural Coherence (LSC) analysis in electron scattering and Electron Energy Loss Spectroscopy (EELS) to elucidate the damage mechanisms in two representative MOFs. MIL101(Fe), and MIL101(Cr). Here, the primary objective is to reveal structural and chemical changes that occur under electron beam irradiation in Scanning Transmission Electron Microscopy (STEM), both in the pristine state and during in-situ CO and CO 2 adsorption. By combining LSC in Radial Distribution Function (RDF) analysis with EELS, comprehensive insights into the nanoscale alterations are obtained and correlated to the electron dose rate.

dos Santos, Gabriel T. [Northwestern University, E↗

Stability and Viability of Off-Axis Photoemission Geometries in 4D Ultrafast Electron Microscopy

Femtosecond (fs) laser-based 4D ultrafast electron microscopy (UEM) commonly makes use of photoelectron emission from a source material in the electron gun region of an otherwise conventional TEM. For TEMs equipped with thermionic guns, the source material is often LaB 6 , the same as used for thermionic operation. Here, such thermionic-based UEMs have proven useful for applications requiring large electron fluxes (i.e., high beam currents) often at the expense of beam coherence and brightness, which is especially important for single-shot nanosecond applications. Importantly, for fs-based UEMs, beam currents can be controlled over a broad range of parameter space through the properties of the fs laser and the photon pulses produced therefrom.

Willis, Simon A. [University of Minnesota, Minneap↗

End-to-End Automated Segmentation Framework for Four-Dimensional Scanning Transmission Electron Microscopy Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) is powerful for rapidly characterizing arrays of nanoparticles produced via high-throughput synthesis. However, such 4D-STEM datasets typically contain thousands of nanoparticles, each characterized by thousands of diffraction patterns spatially distributed across the nanoparticle, necessitating efficient and comprehensive analysis. We propose an end-to-end segmentation framework to automatically segment each nanoparticle into regions with distinct composition/orientation of crystal grains, using only the 4D-STEM data. Bragg disk information is extracted in a physics-informed manner from the diffraction patterns at each spatial location and combined with the real space coordinates to form feature vectors. These feature vectors are then used as inputs to a Gaussian mixture model (GMM) to segment the nanoparticle into distinct regions. We also develop two visualization tools based on the GMM outputs to infer the interface transition and the degree of superposition. Our framework comprehensively integrates machine learning tools and physics knowledge, and provides a basis for substantially compressing enormous 4D-STEM datasets, e.g., by replacing the full 4D-STEM dataset for each nanoparticle with only a single set of Bragg disk features for each distinct crystal grain identified in the nanoparticle. In this article, we demonstrate the power of our framework by presenting results for real, complex datasets.

47 OTHER INSTRUMENTATION↗

Novel Focused Ion Beam Liftouts for Spatial Characterization of Spherical Biominerals With Transmission Electron Microscopy

Abstract Focused ion beam (FIB) is frequently used to prepare electron- and X-ray-beam-transparent thin sections of samples, called lamellae. Typically, lamellae are prepared from only a subregion of a sample. In this paper, we present a novel approach for FIB lamella preparation of microscopic samples, wherein the entire cross-section of the whole sample can be investigated. The approach was demonstrated using spherical, porous, and often hollow microprecipitates of biologically precipitated calcium carbonate. The microprecipitate morphology made these biogenic samples more fragile and challenging than materials commonly investigated using FIB lamellae. Our method enables the appropriate orientation of the lamellae required for further electron/X-ray analyses after attachment to the transmission electron microscopy (TEM) grid post and facilitates more secure adhesion onto the grid post. We present evidence of autofluorescence in bacterially precipitated vaterite using this lamella preparation method coupled with TEM selected area diffraction. This innovative approach allows studying biomineralization at the micro to nano scales, which can provide novel insights into bacterial responses to microenvironmental conditions.

47 OTHER INSTRUMENTATION↗

In-Situ Transmission Electron Microscopy Study of the Evolution of Extended Defects in Oxide Nuclear Fuels

In-situ transmission electron microscopy (TEM) with simulated extreme environments is an effective tool for understanding and tracking microstructural changes down to the atomic scale. The objective of this research is to study the effect of temperature on the evolution of extended defects in ThO2 and UO2. Here, we present in-situ TEM isochronal thermal annealing experiments using a micro-electro-mechanical-system (MEMS)-based heating holder. ThO2 and UO2 single crystal specimens were grown inside an inert silver ampoule using hydrothermal synthesis. Both samples were irradiated using 2 MeV protons at 600oC up to 0.1 dpa at Texas A&M University’s Accelerator Laboratory. Fig. 1a shows a weak-beam dark field TEM image of ThO2 after irradiation, indicating the presence of faulted 1/3 <111> type dislocation loops. This presentation will discuss the effect of annealing temperature (600oC, 800oC, 1000oC, 1100oC, etc.) on dislocation loop density, size and distribution, loop nature (interstitial/vacancies) and Burgers vector, as well as the formation of voids in both ThO2 and UO2. This work will also discuss the interaction between defects during annealing. The in-situ TEM annealing cycle is shown in Fig 1b. This research significantly improves the understanding of defect behavior in oxide nuclear fuels with temperature and will aid computational modeling efforts. This work was supported as part of the Center for Thermal Energy Transport under Irradiation (TETI) Energy Frontier Research Center, funded by the U.S. Department of Energy Office of Science.

36 MATERIALS SCIENCE↗

Revealing Possible Coherence Limiting Sources in Superconducting Qubit with Advanced Electron Microscopy

Superconducting materials hold great potential for solid-state quantum computing. Their fabrication relies on established semiconductor fabrication techniques, such as thin film deposition and lithography, but the complex processing steps can result in defects at the qubits' interfaces and surfaces that can negatively impact coherence time. To improve superconducting qubit performance, it is essential to understand the structural features, at the atomic scale, that may act as sources of decoherence limiting factor in both the Josephson junction (JJ) and resonators, which are key components of superconducting qubit. This talk will present our recent studies on the microstructures in a 2D-transmon, with an emphasis on the JJ. For this research, a combination of advanced microscopy techniques, including high-resolution (S)TEM imaging, and spectroscopy (EDS and EELS) are used to identify possible coherence-limiting defects or structural features.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

The development and use of metal-based probes for X-ray fluorescence microscopy

Abstract X-ray fluorescence microscopy (XFM) has become a widely used technique for imaging the concentration and distribution of metal ions in cells and tissues. Recent advances in synchrotron sources, optics, and detectors have improved the spatial resolution of the technique to <10 nm with attogram detection sensitivity. However, to make XFM most beneficial for bioimaging—especially at the nanoscale—the metal ion distribution must be visualized within the subcellular context of the cell. Over the years, a number of approaches have been taken to develop X-ray-sensitive tags that permit the visualization of specific organelles or proteins using XFM. In this review, we examine the types of X-ray fluorophore used, including nanomaterials and metal ions, and the approaches used to incorporate the metal into their target binding site via antibodies, genetically encoded metal-binding peptides, affinity labeling, or cell-specific peptides. We evaluate their advantages and disadvantages, review the scientific findings, and discuss the needs for future development.

36 MATERIALS SCIENCE↗

Electron microscopy evidence of gadolinium toxicity being mediated through cytoplasmic membrane dysregulation

Past functional toxicogenomic studies have indicated that genes relevant to membrane lipid synthesis are important for tolerance to the lanthanides. Moreover, previously reported imaging of patient's brains following administration of gadolinium-based contrast agents shows gadolinium lining the vessels of the brain. Taken together, these findings suggest the disruption of cytoplasmic membrane integrity as a mechanism by which lanthanides induce cytotoxicity. In the presented work we used scanning transmission electron microscopy and spatially resolved elemental spectroscopy to image the morphology and composition of gadolinium, europium, and samarium precipitates that formed on the outside of yeast cell membranes. In no sample did we find that the lanthanide contaminant had crossed the cell membrane, even in experiments using yeast mutants with disrupted genes for sphingolipid synthesis—the primary lipids found in yeast cytoplasmic membranes. Rather, we have evidence that lanthanides are co-located with phosphorus outside the yeast cells. Finally, these results lead us to hypothesize that the lanthanides scavenge or otherwise form complexes with phosphorus from the sphingophospholipid head groups in the cellular membrane, thereby compromising the structure or function of the membrane, and gaining the ability to disrupt membrane function without entering the cell.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY↗

Using Fourier-Plane Imaging Microscopy for Determining Transition-Dipole-Moment Orientations in Organic Light-Emitting Devices

Here, we use Fourier-plane imaging microscopy (FIM) to determine the transition-dipole-moment orientation in doped organic emissive thin films. The use of FIM enables precise, sensitive, and rapid measurement of dipole orientation in the emission layer of an organic light-emitting device (OLED). An optical model of a stratified birefringent multilayer is introduced for interpreting results obtained by FIM. Using the model, we determine the average orientation of transition-dipole-moment vectors of three phosphorescent dopant emitters. The dipole alignment measured by FIM quantitatively explains the difference in OLED efficiencies using these archetype dopant molecules. FIM provides a nondestructive tool to measure and ultimately improve the outcoupling efficiency of OLEDs and other light-emitting devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

Scanning X-Ray Diffraction Microscopy for Diamond Quantum Sensing

An understanding of nano- and microscale crystal strain in chemical-vapor-deposition diamond is crucial to the advancement of diamond quantum technologies. In particular, the presence of such strain and its characterization presents a challenge to diamond-based quantum sensing and information applications-as well as for future dark-matter detectors, where the directional information about incoming particles is encoded in crystal strain. Here, we exploit nanofocused scanning x-ray diffraction microscopy to quantitatively measure crystal deformation from defects in diamond with high spatial and strain resolution. The combination of information from multiple Bragg angles allows stereoscopic three-dimensional modeling of strain-feature geometry; the diffraction results are validated via comparison to optical measurements of the strain tensor based on spin-state-dependent spectroscopy of ensembles of nitrogen-vacancy centers in the diamond. Finally, our results demonstrate both strain and spatial resolution sufficient for directional detection of dark matter via x-ray measurement of crystal strain and provide a promising tool for diamond growth analysis and improvement of defect-based sensing.

42 ENGINEERING↗

Ferrorotational domain walls revealed by electric quadrupole second harmonic generation microscopy

Domain walls are ubiquitous in materials that undergo phase transitions driven by spontaneous symmetry breaking. Domain walls in ferroics and multiferroics have received tremendous attention recently due to their emergent properties distinct from their domain counterparts—for example, their high mobility and controllability, as well as their potential applications in nanoelectronics. However, it is extremely challenging to detect, visualize, and study the ferrorotational (FR) domain walls because the FR order, in contrast to ferromagnetism and ferroelectricity, is invariant under both the spatial-inversion and the time-reversal operations and, thus, hardly couple with conventional experimental probes. Here, a FR candidate NiTi⁢O 3 is investigated by ultrasensitive electric quadrupole (EQ) second-harmonic generation rotational anisotropy (SHG RA) to probe the point symmetries of the two degenerate FR domain states, showing their relation by the vertical mirror operations that are broken below the FR critical temperature. We then visualize the real-space FR domains by scanning EQ SHG microscopy, and further, resolve the FR domain walls by revealing a suppressed SHG intensity at the domain walls. By taking local EQ SHG RA measurements, we show the restoration of the mirror symmetry at FR domain walls and prove their unconventional nonpolar nature. In conclusion, our findings not only provide a comprehensive insight into FR domain walls, but also demonstrate a unique and powerful tool for future studies on domain walls of unconventional ferroics both of which pave the way towards future manipulations and applications of FR domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Constraints on a split superconducting transition under uniaxial strain in Sr 2 RuO 4 from scanning SQUID microscopy

More than two decades after the discovery of superconductivity in Sr 2 RuO 4 , it is still unclear whether the order parameter has a single component or two degenerate components. For any two-component scenario, application of uniaxial strain is expected to lift the degeneracy, generating two distinct phase transitions. The presence of a second (lower-temperature) transition may be observable by probes that are sensitive to changes in the London penetration depth, λ, as a function of temperature, T. Furthermore, we use scanning SQUID microscopy combined with a uniaxial strain device to test for a second transition under strain. We only observe a single transition. Within the temperature range where a second transition has been suggested by μSR measurements, we further place a tight upper bound of less than 1% on the change in the zero temperature superfluid density n s ∝ λ –2 (0) due to a second transition, suggesting that such a transition does not occur. These results constrain theories of the order parameter in Sr 2 RuO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗