Installation and use of the microscope within a gastight glove box
High resolution phase contrast microscope adaptation for gastight glove box use with stage and focusing knobs in box for Apollo sample microbiological examination
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High resolution phase contrast microscope adaptation for gastight glove box use with stage and focusing knobs in box for Apollo sample microbiological examination
Microbiological fixed-bed process was developed in which supplementary oxygen required by microbial species is supplied by electrochemical device. Rate of addition of oxygen to waste treatment process is controlled to maintain aerobic metabolism and prevent anaerobic metabolisms which produce odorous or toxic products.
The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.
The development of freeze dried vegetables to be used in the Apollo food system is discussed. After the initial selection and screening of vegetables, several types of freeze dried vegetables were prepared in small batches. From these small batches, two vegetables were judged satisfactory for further testing and evaluation. These vegetables, mashed potatoes and asparagus, were subjected to storage at 100 deg plus or minus 5 F. for two weeks and then taste tested. The vegetables were also tested to determine if they complied with the microbiological requirements for Apollo food. The space food prototype production guide for the vegetables is submitted.
Results are presented of laboratory experiments conducted on the thermal resistance of naturally occurring airborne spores and microbiological examinations of space hardware using long-term slit samplers and rodac plate and swab-rinse methods of sampling environmental surfaces.
Complete SL-3 mission objectives and requirements, as revised 1 February 1972 (Rev. 6), are presented. Detailed test objectives are also given on the medical experiments, Apollo Telescope Mount experiments, Earth Resources Experiment Package, and corollary experiments and environmental microbiology experiments.
The principles of clean room technology and the criteria for their application to surgery are discussed. The basic types of surgical clean rooms are presented along with their advantages and disadvantages. Topics discussed include: microbiology of surgery suites; principles of laminar airflow systems, and their use in surgery; and asepsis and the operating room.
The technical development of a computer program for predicting microbial burden on unmanned planetary spacecraft is outlined. The discussion includes the derivation of the basic analytical equations, the selection of a method for handling several random variables, the macrologic of the computer programs and the validation and verification of the model. The prediction model was developed to (1) supplement the biological assays of a spacecraft by simulating the microbial accretion during periods when assays are not taken; (2) minimize the necessity for a large number of microbiological assays; and (3) predict the microbial loading on a lander immediately prior to sterilization and other non-lander equipment prior to launch. It is shown that these purposes not only were achieved but also that the prediction results compare favorably to the estimates derived from the direct assays. The computer program can be applied not only as a prediction instrument but also as a management and control tool. The basic logic of the model is shown to have possible applicability to other sequential flow processes, such as food processing.
Microbial survival in deep space environment, contamination of planets by nonsterile flight hardware, and hazards of back contamination are among the topics covered in papers concerned with the analytical basis for planetary quarantine. The development of the technology and policies of planetary quarantine is covered in contributions on microbiologic assay and sterilization of space flight hardware and control of microbial contamination. A comprehensive subject index is included. Individual items are abstracted in this issue.
Discussion of some of the problems in microbiology and engineering involved in the implementation of planetary quarantine. It is shown that the solutions require new knowledge in both disciplines for success at low cost in terms of both monetary outlay and man's further exploration of the planets. A related problem exists in that engineers are not accustomed to the wide variation of biological data and microbiologists must learn to work and think in more exact terms. Those responsible for formulating or influencing national and international policies must walk a tightrope with delicate balance between unnecessarily stringent requirements for planetary quarantine on the one hand and prevention of contamination on the other. The success of planetary quarantine measures can be assured only by rigorous measures, each checked, rechecked, and triple-checked to make sure that no errors have been made and that no factor has been overlooked.
Discussion of the concept and implications of back contamination and of the ways and means for its prevention. Back contamination is defined as contamination of the terrestrial biosphere with organisms or materials returned from outer space that are capable of potentially harmful terrestrial activity. Since the question of whether or not life exists on other planets may, in reality, not be answered until many samples are returned to earth for detailed study, requirements for the prevention of back contamination are necessary. A review of methods of microbiologic contamination control is followed by a discussion of the nature of back contamination and its risk levels, contamination sources and locations, and possible defenses against back contamination. The U.S. lunar back contamination program is described and shown to provide a valuable basis for further refining the technology for the control of planetary back contamination.
Extensive microbiological analyses that were performed on the Apollo 14 prime and backup crewmembers and ancillary personnel are discussed. The crewmembers were subjected to four separate and quite different environments during the 137-day monitoring period. The relation between each of these environments and observed changes in the microflora of each astronaut are presented.
Activities reported include studies on toxic air contaminants, excessive noise, poor lighting, food sanitation, water pollution, and exposure to nonionizing radiation as health hazards. Formulations for a radiological health manual provide guidance to personnel in the procurement and safe handling of radiation producing equipment and Apollo mission planning. A literature search and development of a water analysis laboratory are outlined to obtain information regarding microbiological problems involving potable water, waste management, and personal hygiene.
Planetary quarantine strategies for advanced spacecraft consider effects of satellite encounter, Jupiter atmosphere entry, space radiation, and cleaning and decontamination techniques on microbiological growth probability. Analytical restructuring is developed for microbial burden prediction and planetary contamination.
The microbiological studies of the Apollo 17 command module pre- and postflight samples are reported. A total of 20 types of microorganisms were identified on preflight and 14 on postflight samples. Changes in biochemical character due to subculture and storage of Bacillus isolates are also reported.
Data from numerous experiments and hardware inventories were scanned for Skylab personal hygiene use. A computer program was formulated for predicting the degree of man's involvement with personal hygiene needs. A tabulation was kept for such events as water intake, frequency of urination and defecation, accidents or events requiring clean-up, methods of clean-up, microbiological environment and shower water contamination.
A description of the design and function of the Apollo potable water system is presented. The command module potable water is supplied as a byproduct of the fuel cells. The cells, located in the service module, function primarily to supply electrical energy to the spacecraft. The source of the lunar module potable water is three tanks, which are filled before lift-off. The technique of supplying the water in each of these cases and the problems associated with materials compatibility are described. The chemical and microbiological quality of the water is reviewed, as are efforts to maintain the water in a microbially safe condition for drinking and food mixing.
Biomedical support hardware for SMEAT consisted basically of two systems, the inflight medical support system, and the operational bioinstrumentation system. The former is essentially a diagnostic and therapeutic kit; the latter is a belt equipped with sensors worn by the crewman to permit monitoring of his vital signs. Special attention was given during to the use and verification of the items in the systems so that changes required in the equipment could be pinpointed and effected prior to the Skylab mission. During the in-chamber testing, evaluations were made of the effectiveness of the proposed microbiology procedures, techniques, equipment, and the stability of media and reagents over the extended period of storage.