Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Likelihood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Pretreatment Prostate Volume on Severe Acute Genitourinary Toxicity in Prostate Cancer Patients Treated With Intensity-Modulated Radiation Therapy

Purpose: To assess the impact of pretreatment prostate volume on the development of severe acute genitourinary toxicity in patients undergoing intensity-modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Between 2004 and 2007, a consecutive sample of 214 patients who underwent IMRT (75.6 Gy) for prostate cancer at two referral centers was analyzed. Prostate volumes were obtained from computed tomography scans taken during treatment simulation. Genitourinary toxicity was defined using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 3.0 guidelines. Acute toxicity was defined as any toxicity originating within 90 days of the completion of radiation therapy. Patients were characterized as having a small or large prostate depending on whether their prostate volume was less than or greater than 50 cm{sup 3}, respectively. Genitourinary toxicity was compared in these groups using the chi-square or Fisher's exact test, as appropriate. Bivariate and multivariate logistic regression analysis was performed to further assess the impact of prostate volume on severe (Grade 3) acute genitourinary toxicity. Results: Patients with large prostates (>50 cm{sup 3}) had a higher rate of acute Grade 3 genitourinary toxicity (p = .02). Prostate volume was predictive of the likelihood of developing acute Grade 3 genitourinary toxicity on bivariate (p = .004) and multivariate (p = .006) logistic regression. Every 27.0 cm{sup 3} increase in prostate volume doubled the likelihood of acute Grade 3 genitourinary toxicity. Conclusions: Patients with larger prostates are at higher risk for the development of severe acute genitourinary toxicity when treated with IMRT for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Radiation Oncologists Would Disclose Errors: Results of a Survey of Radiation Oncologists and Trainees

Purpose: To analyze error disclosure attitudes of radiation oncologists and to correlate error disclosure beliefs with survey-assessed disclosure behavior. Methods and Materials: With institutional review board exemption, an anonymous online survey was devised. An email invitation was sent to radiation oncologists (American Society for Radiation Oncology [ASTRO] gold medal winners, program directors and chair persons of academic institutions, and former ASTRO lecturers) and residents. A disclosure score was calculated based on the number or full, partial, or no disclosure responses chosen to the vignette-based questions, and correlation was attempted with attitudes toward error disclosure. Results: The survey received 176 responses: 94.8% of respondents considered themselves more likely to disclose in the setting of a serious medical error; 72.7% of respondents did not feel it mattered who was responsible for the error in deciding to disclose, and 3.9% felt more likely to disclose if someone else was responsible; 38.0% of respondents felt that disclosure increased the likelihood of a lawsuit, and 32.4% felt disclosure decreased the likelihood of lawsuit; 71.6% of respondents felt near misses should not be disclosed; 51.7% thought that minor errors should not be disclosed; 64.7% viewed disclosure as an opportunity for forgiveness from the patient; and 44.6% considered the patient's level of confidence in them to be a factor in disclosure. For a scenario that could be considerable, a non-harmful error, 78.9% of respondents would not contact the family. Respondents with high disclosure scores were more likely to feel that disclosure was an opportunity for forgiveness (P=.003) and to have never seen major medical errors (P=.004). Conclusions: The surveyed radiation oncologists chose to respond with full disclosure at a high rate, although ideal disclosure practices were not uniformly adhered to beyond the initial decision to disclose the occurrence of the error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of the Utility of Magnetic Resonance Imaging in Determining Candidacy for Partial Breast Irradiation

Purpose: Retrospective data have demonstrated that breast magnetic resonance imaging (MRI) may change a patient's eligibility for partial breast irradiation (PBI) by identifying multicentric, multifocal, or contralateral disease. The objective of the current study was to prospectively determine the frequency with which MRI identifies occult disease and to establish clinical factors associated with a higher likelihood of MRI prompting changes in PBI eligibility. Methods and Materials: At The University of Chicago, women with breast cancer uniformly undergo MRI in addition to mammography and ultrasonography. From June 2009 through May 2011, all patients were screened prospectively in a multidisciplinary conference for PBI eligibility based on standard imaging, and the impact of MRI on PBI eligibility according to National Surgical Adjuvant Breast and Bowel Project protocol B-39/Radiation Therapy Oncology Group protocol 0413 entry criteria was recorded. Univariable analysis was performed using clinical characteristics in both the prospective cohort and in a separate cohort of retrospectively identified patients. Pooled analysis was used to derive a scoring index predictive of the risk that MRI would identify additional disease. Results: A total of 521 patients were screened for PBI eligibility, and 124 (23.8%) patients were deemed eligible for PBI based on standard imaging. MRI findings changed PBI eligibility in 12.9% of patients. In the pooled univariable analysis, tumor size ≥2 cm on mammography or ultrasonography (P=.02), age <50 years (P=.01), invasive lobular histology (P=.01), and HER-2/neu amplification (P=.01) were associated with a higher likelihood of MRI changing PBI eligibility. A predictive score was generated by summing the number of significant risk factors. Patients with a score of 0, 1, 2, and 3 had changes to eligibility based on MRI findings in 2.8%, 13.2%, 38.1%, and 100%, respectively (P<.0001). Conclusions: MRI identified additional disease in a significant number of patients eligible for PBI, based on standard imaging. Clinical characteristics may be useful in directing implementation of MRI in the staging of PBI candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nomograms Predicting Response to Therapy and Outcomes After Bladder-Preserving Trimodality Therapy for Muscle-Invasive Bladder Cancer

Purpose: Selective bladder preservation by use of trimodality therapy is an established management strategy for muscle-invasive bladder cancer. Individual disease features have been associated with response to therapy, likelihood of bladder preservation, and disease-free survival. We developed prognostic nomograms to predict the complete response rate, disease-specific survival, and likelihood of remaining free of recurrent bladder cancer or cystectomy. Methods and Materials: From 1986 to 2009, 325 patients were managed with selective bladder preservation at Massachusetts General Hospital (MGH) and had complete data adequate for nomogram development. Treatment consisted of a transurethral resection of bladder tumor followed by split-course chemoradiation. Patients with a complete response at midtreatment cystoscopic assessment completed radiation, whereas those with a lesser response underwent a prompt cystectomy. Prognostic nomograms were constructed predicting complete response (CR), disease-specific survival (DSS), and bladder-intact disease-free survival (BI-DFS). BI-DFS was defined as the absence of local invasive or regional recurrence, distant metastasis, bladder cancer-related death, or radical cystectomy. Results: The final nomograms included information on clinical T stage, presence of hydronephrosis, whether a visibly complete transurethral resection of bladder tumor was performed, age, sex, and tumor grade. The predictive accuracy of these nomograms was assessed. For complete response, the area under the receiving operating characteristic curve was 0.69. The Harrell concordance index was 0.61 for both DSS and BI-DFS. Conclusions: Our nomograms allow individualized estimates of complete response, DSS, and BI-DFS. They may assist patients and clinicians making important treatment decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Uncertainty in QUANTEC's Dose–Response Relation of Lung and Spinal Cord With a Bootstrap Analysis

Purpose: To apply a statistical bootstrap analysis to assess the uncertainty in the dose–response relation for the endpoints pneumonitis and myelopathy reported in the QUANTEC review. Methods and Materials: The bootstrap method assesses the uncertainty of the estimated population-based dose-response relation due to sample variability, which reflects the uncertainty due to limited numbers of patients in the studies. A large number of bootstrap replicates of the original incidence data were produced by random sampling with replacement. The analysis requires only the dose, the number of patients, and the number of occurrences of the studied endpoint, for each study. Two dose–response models, a Poisson-based model and the Lyman model, were fitted to each bootstrap replicate using maximum likelihood. Results: The bootstrap analysis generates a family of curves representing the range of plausible dose–response relations, and the 95% bootstrap confidence intervals give an estimated upper and lower toxicity risk. The curve families for the 2 dose–response models overlap for doses included in the studies at hand but diverge beyond that, with the Lyman model suggesting a steeper slope. The resulting distributions of the model parameters indicate correlation and non-Gaussian distribution. For both data sets, the likelihood of the observed data was higher for the Lyman model in >90% of the bootstrap replicates. Conclusions: The bootstrap method provides a statistical analysis of the uncertainty in the estimated dose–response relation for myelopathy and pneumonitis. It suggests likely values of model parameter values, their confidence intervals, and how they interrelate for each model. Finally, it can be used to evaluate to what extent data supports one model over another. For both data sets considered here, the Lyman model was preferred over the Poisson-based model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Mammographic Changes Across Three Different Fractionation Schedules for Early-Stage Breast Cancer

Purpose: As the use of hypofractionated breast radiation therapy (RT) increases, so will the need for long-term data on post-RT mammographic changes. The purpose of the present study was to longitudinally compare the incidence of common mammographic sequelae seen after breast conserving surgery and RT in patients treated with accelerated partial breast irradiation (APBI), hypofractionated whole breast irradiation (HWBI), and conventionally fractionated whole breast irradiation (WBI). Methods and Materials: Patients treated with either APBI or HWBI after breast conserving therapy and with ≥3 mammograms of the treated breast were identified. They were matched 1:1 by age ±5 years to patients treated with WBI. The mammograms were evaluated for common post-RT breast findings by a mammographer who was unaware of the treatment. The outcomes were analyzed using a cumulative logistic regression model; P<.05 indicated statistically significance. Results: Of 89 patients treated with RT from 2006 to 2011, 29 had received APBI, 30 had received HWBI, and 30 had received WBI. Their median age was 60 years (range 33-83). A total of 605 mammograms were evaluated, with a median follow-up of 48 months. The treatment technique did not affect the severity of architectural distortion when the groups were evaluated longitudinally. The likelihood of finding skin thickening decreased with increasing follow-up duration (odds ratio 0.6; P<.001) adjusted for fractionation schemes. No differences were seen with respect to changes in skin thickening, fluid collections, or calcifications among the treatment groups, after adjustment for the follow-up time. The clinical characteristics, including age, race, T stage, and chemotherapy use, were not linked to the likelihood of finding several mammographic phenomena over time. Conclusions: Although specific post-treatment imaging findings evolved over time, RT fractionation did not alter the relative incidence or severity of architectural distortion, skin thickening, fluid collections, or calcifications. These findings will be useful to both radiologists and radiation oncologists when counseling patients regarding follow-up studies after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs on each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nature of Medical Malpractice Claims Against Radiation Oncologists

Purpose: To examine characteristics of medical malpractice claims involving radiation oncologists closed during a 10-year period. Methods and Materials: Malpractice claims filed against radiation oncologists from 2003 to 2012 collected by a nationwide liability insurance trade association were analyzed. Outcomes included the nature of claims and indemnity payments, including associated presenting diagnoses, procedures, alleged medical errors, and injury severity. We compared the likelihood of a claim resulting in payment in relation to injury severity categories (death as referent) using binomial logistic regression. Results: There were 362 closed claims involving radiation oncology, 102 (28%) of which were paid, resulting in $38 million in indemnity payments. The most common alleged errors included “improper performance” (38% of closed claims, 18% were paid; 29% [$11 million] of total indemnity), “errors in diagnosis” (25% of closed claims, 46% were paid; 44% [$17 million] of total indemnity), and “no medical misadventure” (14% of closed claims, 8% were paid; less than 1% [$148,000] of total indemnity). Another physician was named in 32% of claims, and consent issues/breach of contract were cited in 18%. Claims for injury resulting in death represented 39% of closed claims and 25% of total indemnity. “Improper performance” was the primary alleged error associated with injury resulting in death. Compared with claims involving death, major temporary injury (odds ratio [OR] 2.8, 95% confidence interval [CI] 1.29-5.85, P=.009), significant permanent injury (OR 3.1, 95% CI 1.48-6.46, P=.003), and major permanent injury (OR 5.5, 95% CI 1.89-16.15, P=.002) had a higher likelihood of a claim resulting in indemnity payment. Conclusions: Improper performance was the most common alleged malpractice error. Claims involving significant or major injury were more likely to be paid than those involving death. Insights into the nature of liability claims against radiation oncologists may help direct efforts to improve quality of care and minimize the risk of being sued.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Geriatric Assessment Tools in Selecting Therapies in Women Aged ≥70 Years With Hormone Receptor–Positive Early-Stage Breast Cancer: Preliminary Experience With a Quality Improvement Initiative

Purpose: To develop a multidisciplinary algorithmic approach to management of women aged ≥70 years with clinically staged T1N0 hormone receptor–positive breast cancer, including geriatric assessments predicting life expectancy and the likelihood of functional decline in the near future, in the context of a program-wide quality improvement initiative, to better select patients for therapeutic interventions. Methods and Materials: Two geriatric assessment tools, the Combined Lee-Schonberg Index and the Vulnerable Elderly Scale, were introduced into our clinical workflow to predict long-term mortality and likelihood of functional decline. Scores from these tools, along with patient preferences and clinical features, were incorporated into a preoperative algorithm addressing the use of sentinel lymph node biopsy (SLNB), and a postoperative algorithm addressing the use of adjuvant radiation therapy (RT). Results: The algorithms were approved for use in August 2015. Twenty-four patients were identified by in-clinic screening and have been managed using the algorithms as a guide. Mean patient age was 80 years (range, 71-89 years). Per the preoperative algorithm, consideration of omission of SLNB was an option in 11 of 24 patients (46%), and in total 18 of 24 (75%) opted against SLNB. Per the postsurgical algorithm, consideration of omission of adjuvant RT was an option for 19 of 24 patients (79%), and in total 17 of 24 (71%) opted to forego RT. Conclusion: Incorporation of simple geriatric assessments seems to have had a marked impact on decision making regarding both surgical and adjuvant therapies for women aged ≥70 years with early-stage hormone-positive breast cancer compared with historical patterns, with ≥71% omission of both SLNB and adjuvant RT in patients managed according to an institutional quality improvement initiative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Jacobian-free Newton Krylov method for mortar-discretized thermomechanical contact problems

Multibody contact problems are common within the field of multiphysics simulation. Applications involving thermomechanical contact scenarios are also quite prevalent. Such problems can be challenging to solve due to the likelihood of thermal expansion affecting contact geometry which, in turn, can change the thermal behavior of the components being analyzed. This paper explores a simple model of a light water reactor nuclear fuel rod, which consists of cylindrical pellets of uranium dioxide (UO{sub 2}) fuel sealed within a Zircalloy cladding tube. The tube is initially filled with helium gas, which fills the gap between the pellets and cladding tube. The accurate modeling of heat transfer across the gap between fuel pellets and the protective cladding is essential to understanding fuel performance, including cladding stress and behavior under irradiated conditions, which are factors that affect the lifetime of the fuel. The thermomechanical contact approach developed here is based on the mortar finite element method, where Lagrange multipliers are used to enforce weak continuity constraints at participating interfaces. In this formulation, the heat equation couples to linear mechanics through a thermal expansion term. Lagrange multipliers are used to formulate the continuity constraints for both heat flux and interface traction at contact interfaces. The resulting system of nonlinear algebraic equations are cast in residual form for solution of the transient problem. A Jacobian-free Newton Krylov method is used to provide for fully-coupled solution of the coupled thermal contact and heat equations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian inference of nonlinear unsteady aerodynamics from aeroelastic limit cycle oscillations

A Bayesian model selection and parameter estimation algorithm is applied to investigate the influence of nonlinear and unsteady aerodynamic loads on the limit cycle oscillation (LCO) of a pitching airfoil in the transitional Reynolds number regime. At small angles of attack, laminar boundary layer trailing edge separation causes negative aerodynamic damping leading to the LCO. The fluid–structure interaction of the rigid, but elastically mounted, airfoil and nonlinear unsteady aerodynamics is represented by two coupled nonlinear stochastic ordinary differential equations containing uncertain parameters and model approximation errors. Several plausible aerodynamic models with increasing complexity are proposed to describe the aeroelastic system leading to LCO. The likelihood in the posterior parameter probability density function (pdf) is available semi-analytically using the extended Kalman filter for the state estimation of the coupled nonlinear structural and unsteady aerodynamic model. The posterior parameter pdf is sampled using a parallel and adaptive Markov Chain Monte Carlo (MCMC) algorithm. The posterior probability of each model is estimated using the Chib–Jeliazkov method that directly uses the posterior MCMC samples for evidence (marginal likelihood) computation. The Bayesian algorithm is validated through a numerical study and then applied to model the nonlinear unsteady aerodynamic loads using wind-tunnel test data at various Reynolds numbers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear sparse Bayesian learning for physics-based models

This paper addresses the issue of overfitting while calibrating unknown parameters of over-parameterized physics-based models with noisy and incomplete observations. Here, a semi-analytical Bayesian framework of nonlinear sparse Bayesian learning (NSBL) is proposed to identify sparsity among model parameters during Bayesian inversion. NSBL offers significant advantages over machine learning algorithm of sparse Bayesian learning (SBL) for physics-based models, such as 1) the likelihood function or the posterior parameter distribution is not required to be Gaussian, and 2) prior parameter knowledge is incorporated into sparse learning (i.e. not all parameters are treated as questionable). NSBL employs the concept of automatic relevance determination (ARD) to facilitate sparsity among questionable parameters through parameterized prior distributions. The analytical tractability of NSBL is enabled by employing Gaussian ARD priors and by building a Gaussian mixture-model approximation of the posterior parameter distribution that excludes the contribution of ARD priors. Subsequently, type-II maximum likelihood is executed using Newton's method whereby the evidence and its gradient and Hessian information are computed in a semi-analytical fashion. We show numerically and analytically that SBL is a special case of NSBL for linear regression models. Subsequently, a linear regression example involving multimodality in both parameter posterior pdf and model evidence is considered to demonstrate the performance of NSBL in cases where SBL is inapplicable. Next, NSBL is applied to identify sparsity among the damping coefficients of a mass-spring-damper model of a shear building frame. These numerical studies demonstrate the robustness and efficiency of NSBL in alleviating overfitting during Bayesian inversion of nonlinear physics-based models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-variance replica exchange SGMCMC for inverse and forward problems via Bayesian PINN

Physics-informed neural network (PINN) has been successfully applied in solving a variety of nonlinear non-convex forward and inverse problems. However, the training is challenging because of the non-convex loss functions and the multiple optima in the Bayesian inverse problem. In this work, we propose a multi-variance replica exchange stochastic gradient Langevin dynamics method to tackle the challenge of the multiple local optima in the optimization and the challenge of the multiple modal posterior distribution in the inverse problem. Replica exchange methods are capable of escaping from the local traps and accelerating the convergence; two chains with different temperatures are designed where the low temperature chain aims for the local convergence, and the target of the high temperature chain is to travel globally and explore the whole loss function entropy landscape. However, it may not be efficient to solve mathematical inversion problems by using the vanilla replica method directly since the method doubles the computational cost in evaluating the forward solvers (likelihood functions) in the two chains. To address this issue, we propose to make different assumptions on the energy function estimation and this facilities one to use solvers of different fidelities in the likelihood function evaluation. More precisely, one can use a solver with low fidelity in the high temperature chain while using a solver with high fidelity in the low temperature chain. Our proposed method significantly lowers the computational cost in the high temperature chain, meanwhile preserving the accuracy and converging very fast. Here we give an unbiased estimate of the swapping rate and give an estimation of the discretization error of the scheme. To verify our idea, we design and solve four inverse problems which have multiple modes. The proposed method is also employed to train the Bayesian PINN to solve the forward and inverse problems; faster and more accurate convergence has been observed when compared to the stochastic gradient Langevin dynamics (SGLD) method and vanilla replica exchange methods.

97 MATHEMATICS AND COMPUTING↗

Planning green infrastructure placement based on projected precipitation data

Continued urbanization has led to tremendous changes on the landscape. These changes have exacerbated the effects of extreme climatic events such as flooding because of constrained water infiltration and increased surface flow. Typical runoff control measures involve sophisticated gray infrastructure that guide excess surface flow into storage and disposal sites. In a dynamic climate system, these measures are not sustainable since they cannot be easily modified to accommodate large volumes of runoff. Green Infrastructure (GI) is an adaptable technique that can be used to minimize runoff, in addition to offering an array of additional benefits (urban heat regulation, aesthetics, improved air quality etc.). Strategic placement of GI is key to achieving maximum utility. While physical site characteristics play a major role in determining suitable GI placement sites, knowledge of future precipitation patterns is crucial to ensure successful flood mitigation. Here, suitable GI sites within the city of Knoxville, Tennessee, were determined based on potential impact of an extreme flood event as indicated by site characteristics. Then, the relative potential likelihood of a flood event was determined based on projected precipitation data and knowledge of existing flood zones. By combining potential impact with likelihood information, low, medium, and high priority GI implementation sites were established. Results indicate that high priority sites are in the central parts of the city with priority decreasing outward. The GI prioritization scheme presented here, offers valuable guidance to city planners and policy makers who wish to exploit the GI approach for flood mitigation.

54 ENVIRONMENTAL SCIENCES↗

High tensile alloy of copper to mitigate current collector deformation in silicon electrodes for lithium-ion batteries

The volumetric changes of silicon electrodes, along with the strong adhesive properties of certain binders, can lead to plastic deformation of the current collector and create damage in the electrode coating. Here, in this study, we report a detailed study of silicon coatings on a high-tensile alloy (HTA) foil of copper with strength over twice that of conventional copper foils. The HTA current collectors with high mechanical strength can mitigate plastic deformation upon continuous cycling. At moderate areal capacities (2.5–3 mAh cm −2 ), conventional copper foils show significant wrinkling after only a few electrochemical cycles, whereas the HTA foils remain intact. We demonstrate viability of the HTA foils in large format xx6395 pouch cells, in which the HTA current collectors remain intact even at an areal capacity of 4.5 mAh cm −2 ; in contrast, wrinkles form in conventional copper current collectors increasing the likelihood of lithium plating. Computational studies show that stresses generated during cycling of silicon electrodes are very high in the current collector and at the current collector-coating interface, explaining the wrinkling of conventional Cu foils. Our studies highlight importance of current collector to solve the electrochemical and chemo-mechanical performance challenges associated with high-loading silicon electrodes.

Chemo-mechanical degradation↗

Performance of neutron spectrum unfolding using deuterated liquid scintillator

The performance of the maximum likelihood expectation maximization method for unfolding neutron energy spectra using deuterated liquid scintillator is evaluated for future utilization with rare isotope beams. High-resolution neutron energy spectra as well as the detector response matrix were measured at the Edwards Accelerator Laboratory at Ohio University. Maximum-likelihood expectation maximization (MLEM) unfolded neutron spectra are compared with spectra from neutron time-of-flight. In conclusion, the effects of the MLEM stopping criteria and spectrum statistics are also investigated.

47 OTHER INSTRUMENTATION↗

Emergency core cooling system performance criteria for Multi-Layered Silicon Carbide nuclear fuel cladding

Multi-layered Silicon Carbide (SiC) cladding has been proposed to replace the current Zircaloy (Zr) cladding in existing nuclear power plants. Due to its ceramic property, SiC may have a different failure mechanism from that of metallic Zr clad. This characteristic should be considered in designing the plant’s safety system performance, such that the fuel’s integrity is reasonably assured during accident scenarios. This paper aims at optimizing the Emergency Core Cooling System (ECCS) performance criteria in mitigating LBLOCA accidents at a Pressurized Water Reactor (PWR) using the uranium dioxide fuel and duplex or triplex SiC cladding structures. Clad failures by brittle fractures and thermal degradation were modeled in a fuel analysis code. This fuel model was coupled with the RELAP5 plant model by adapting the fuel’s mesh configuration and formulating the effective heat transfer coefficients. A model to quantify the likelihood of clad functional failure as a combination of individual layer fractures at various axial positions was proposed. Updated SiC material properties were gathered from recent reference studies. Clad reliability estimates using the proposed model were compared with the estimates obtained using other models. The results were used to relax the criterion of required actuation timing of ECCS, such that the risk of the new plant design is less or equal to that of the initial plant configuration. Triplex clad was more reliable than duplex clad and Zr, reducing the conditional core damage probability by three orders of magnitude in the reference LBLOCA scenario. Compressive stresses due to irradiation swelling played the determining role in the vulnerabilities of each clad design. The duplex clad was vulnerable to pressure-loading stresses while triplex clad was prone to fail due to thermal shocks experienced during the LOCA reflood phase. Additionally, it was concluded that the most vulnerable axial fuel rod location in the reference LBLOCA scenario was located at the highest axial power peaking location. A sensitivity study on the ECCS timing density was conducted. The results showed that ECCS actuation timing could be extended from the initial technical specification, without increasing the fuel damage likelihood. The time extension was distributed in the order of several hundreds of seconds, which was comparable with time extensions offered by FeCrAl and Cr-coated-Zr clad designs in LBLOCA scenarios. This time extension may potentially reduce the failure probabilities of EDGs and pumps, hence improving the plant safety further.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗