Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Overview of CW electron guns and LCLS-II RF gun performance

Various continuous-wave (CW) electron gun technologies are reviewed, including DC, superconducting radio frequency RF (SRF), hybrid DC-SRF and normal-conducting RF. Also, the SLAC Linac Coherent Light Source II (LCLS-II) normal-conducting RF gun and injector are described, and the performance to date, including the bunch emittance achieved and the dark current observed, is presented.

43 PARTICLE ACCELERATORS↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolutional Neural Network for Segmenting Micro-X-ray Computed Tomography Images of Wood Cellular Structures

To further enhance the performance of wood products, improved tools are needed to study in situ cellular scale phenomena like mechanical deformations and moisture swelling. Micro-X-ray computed tomography (μXCT) using brilliant synchrotron light sources now has the spatial and temporal resolution for real-time visualization of phenomena in three-dimensional cellular structures. However, the tradeoff for speed includes the loss of intensity contrast between different types of materials within the imaged structure, such as cell wall and air in wood. This loss of contrast prevents traditional histogram-based segmentation methods from being used effectively. A new convolutional neural network (CNN) approach was therefore developed to segment fast μXCT images of wood into cell wall and air volumes. The fast μXCT and segmentation were demonstrated in the study of moisture swelling in loblolly pine (Pinus taeda) earlywood and latewood cellular structures conditioned at 0%, 33%, 75%, and 95% relative humidity (RH). The CNN segmentation results had a mean intersection over union (IoU) metric accuracy of 96%. Initial analysis of the swelling in the latewood revealed cell walls swelled about 25% when conditioned from 0% to 95% RH. Additionally, the widths of ray cell lumina in the transverse plane of latewood could be observed to increase at higher RH. The segmentation method presented here will facilitate future quantitative analyses in in situ μXCT studies of wood and other similar cellular materials.

Arzola-Villegas, Xavier (ORCID:0000000305369766)↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Surface Electronic Structure of Cr Doped Bi 2 Se 3 Single Crystals

Here, by using angle-resolved photoemission spectroscopy, we showed that Bi 2-x Cr x Se 3 single crystals have a distinctly well-defined band structure with a large bulk band gap and undistorted topological surface states. These spectral features are unlike their thin film forms in which a large nonmagnetic gap with a distorted band structure was reported. We further provide laser-based high resolution photoemission data which reveal a Dirac point gap even in the pristine sample. The gap becomes more pronounced with Cr doping into the bulk of Bi 2 Se 3 . These observations show that the Dirac point can be modified by the magnetic impurities as well as the light source.

36 MATERIALS SCIENCE↗

Development of a High Min-Entropy Quantum Random Number Generator Based on Amplified Spontaneous Emission

We present the theory, architecture, and performance characteristics of a quantum random number generator (QRNG) which operates in a PCI express form factor-compatible plug-and-play design. The QRNG relies on a thermal light source (in this case, amplified spontaneous emission), which exhibits photon bunching according to the Bose–Einstein (BE) statistics. We demonstrate that 98.7% of the unprocessed random bit stream min-entropy is traceable to the BE (quantum) signal. The classical component is then removed using a non-reuse shift-XOR protocol, and the final random numbers are generated at a 200 Mbps rate and shown to pass the statistical randomness test suites FIPS 140-2, Alphabit, SmallCrush, DIEHARD, and Rabbit of the TestU01 library.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heat Diffusion in High-Cp Nb3Sn Composite Superconducting Wires

A major focus of Nb3Sn accelerator magnets is on significantly reducing or eliminating their training. Demonstration of an approach to increase the Cp of Nb3Sn magnets using new materials and technologies is very important both for particle accelerators and light sources. It would improve thermal stability and lead to much shorter magnet training, with substantial savings in machines’ commissioning costs. Both Hypertech and Bruker-OST have attempted to introduce high-Cp elements in their wire design. This paper includes a description of these advanced wires, the finite element model of their heat diffusion properties as compared with the standard wires, and whenever available, a comparison between the minimum quench energy (MQE) calculated by the model and actual MQE measurements on wires.

43 PARTICLE ACCELERATORS↗

Overview and Commissioning Status of the UCLA MITHRA Facility

Presented here are the first results of commissioning of the S-Band hybrid photoinjector and laser systems at the new accelerator and light source facility, MITHRA, at UCLA. The radiation bunker and capabilities of the facility are described with motivation for detailed measurement of beam parameters explained. Following thorough characterization of the photoinjector, a 1.5 m linac is to be installed and experiments up to 30 MeV will begin. These will include experiments in basic plasma physics, space plasma, terahertz production in dielectric structures, and inverse Compton scattering and applications for the X-rays produced.

Williams, Oliver (ORCID:0000000255874982)↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Relations between Shot Noise, Gain Bandwidth, and Saturation of Instabilities

There are numerous instabilities present in charged particle beams that undergo exponential growth and reach saturation. In various applications, such as free-electron lasers or micro-bunching light sources, achieving saturation is desirable. Conversely, there are applications where these instabilities are utilized as linear broad-band amplifiers for signals embedded in the charged beam. In the latter scenario, the saturation of an instability induces non-linear distortions in the imprinted signal, thereby limiting the useful range of such amplifiers. Accurate evaluation of these instabilities necessitates a complete and comprehensive modeling approach that includes shot noise within the beam. Unfortunately, such modeling is not always feasible or practical. In this paper, we introduce a methodology utilizing the frequency and bandwidth of the instability as key parameters. Through this, we derive an estimation for the range of linear instability growth. Our derivation is conducted in a model-independent manner, making it applicable to a broad spectrum of instabilities. To validate our approach, we employ established and thoroughly benchmarked simulations with a free electron laser (FEL) code as well as self-consistent 3-dimensional simulation of plasma-cascade instability using code SPACE.

43 PARTICLE ACCELERATORS↗

Binary Amplitude Reflection Gratings for X-ray Shearing and Hartmann Wavefront Sensors

New, high-coherent-flux X-ray beamlines at synchrotron and free-electron laser light sources rely on wavefront sensors to achieve and maintain optimal alignment under dynamic operating conditions. This includes feedback to adaptive X-ray optics. We describe the design and modeling of a new class of binary-amplitude reflective gratings for shearing interferometry and Hartmann wavefront sensing. Compact arrays of deeply etched gratings illuminated at glancing incidence can withstand higher power densities than transmission membranes and can be designed to operate across a broad range of photon energies with a fixed grating-to-detector distance. Coherent wave-propagation is used to study the energy bandwidth of individual elements in an array and to set the design parameters. We observe that shearing operates well over a ±10% bandwidth, while Hartmann can be extended to ±30% or more, in our configuration. We apply this methodology to the design of a wavefront sensor for a soft X-ray beamline operating from 230 eV to 1400 eV and model shearing and Hartmann tests in the presence of varying wavefront aberration types and magnitudes.

47 OTHER INSTRUMENTATION↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Near L-edge Single and Multiple Photoionization of Doubly Charged Iron Ions

Using the photon-ion merged-beams technique at a synchrotron light source, we have measured relative cross sections for single and up to five-fold photoionization of Fe 2+ ions in the energy range of 690-920 eV. This range contains thresholds and resonances associated with ionization and excitation of 2p and 2s electrons. Calculations were performed to simulate the total absorption spectra. The theoretical results show very good agreement with the experimental data, if overall energy shifts of up to 2.5 eV are applied to the calculated resonance positions and assumptions are made about the initial experimental population of the various levels of the Fe 2+ ([Ar]3d 6 ) ground configuration. Furthermore, we performed extensive calculations of the Auger cascades that result when an electron is removed from the 2p subshell of Fe 2+ . These computations lead to a better agreement with the measured product-charge-state distributions as compared to earlier work. We conclude that the L-shell absorption features of low-charged iron ions are useful for identifying gas-phase iron in the interstellar medium and for discriminating against the various forms of condensed-phase iron bound to composite interstellar dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗

Field Deployable Mirror Soiling Detection Based on Polarimetric Imaging

Heliostat mirror soiling is one of the significant factors for reduced optical efficiency of Concentrated Solar Power (CSP) fields. However, it remains challenging to determine the mirror soiling patterns across the large area of the CSP field. Here we propose a fast and field deployable inspection method to measure the heliostat mirror soiling levels based on polarization images in regular daylight settings without additional light sources. Under sunny and clear sky conditions, we have demonstrated accurate measurement of reflection efficiency (error ~1%) for mirrors with different soiling levels.

14 SOLAR ENERGY↗

Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher

Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.

54 ENVIRONMENTAL SCIENCES↗

LCLS RF Station Phase Anomaly Candidate Dataset

A public anomaly detection dataset constructed from RF station faults for phase at SLAC's LCLS (Linac Coherent Light Source). We have compiled a dataset of the RF station diagnostic phase data and the beam-position monitor (BPM) signals, alongside the hand labels, for a labeled study period. The dataset consists of two HDF5 files (one for train and one for test) containing the raw data, two CSV files containing information about the candidates. The CSV file for the test dataset also contains the label.

Liang, Jia [Stanford Univ., CA (United States). In↗

Fluorescent air leakage detection system for enclosures

Provided is a Fluorescent Air Leakage Detection (FALD) system and method for locating a defect in an enclosure that uses a nontoxic fluorescent solution as a marker. The solution is aerosolized with an atomizing device and guided to defects by a gas pressure modifying device. Defects are visually located by surveying the enclosure with an ultraviolet or visible light source and identifying a location where accumulated solution fluoresces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗