Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A Novel Technique of Extracting UCN Decay Lifetime from Storage Chamber Measurements Dominated by Scattering Losses

The neutron’s lifetime is a critical parameter in the standard model. Its measurements, particularly measurements using both beamline and ultracold neutron storage techniques, have revealed significant tension. In this work, we review the status of the tension between various measurements, especially in light of the insights provided by the β-decay correlation measurements. We revisit the lifetime measurement in a material storage chamber, dominated by losses from scattering off the walls of the storage chamber. The neutron energy spectra and associated uncertainties were, for the first time, well-characterized using storage data alone. Such models have applications in the extraction of the mean time between wall bounces, which is a key parameter for neutron storage disappearance experiments in search of neutron oscillation. A comparison between the loss model and the number of neutrons stored in a single chamber allowed us to extract a neutron lifetime of τn*=880(+158/−78)stat.(+230/−114)sys.s (68.3% C.I.). Though the uncertainty of this lifetime is not competitive with currently available measurements, the highlight of this work is that we precisely identified the systematic sources of uncertainty that contribute to the neutron lifetime measurements in material storage bottles, namely from the uncertainty in the energy spectra, as well as from the storage chamber surface parameters of the Fermi potential and loss per bounce. In doing so, we highlight the underestimation of the uncertainties in the previous Monte Carlo simulations of experiments using the technique of ultracold neutron storage in material bottles.

Mohanmurthy, Prajwal (ORCID:0000000275737010)↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

New Homogeneous Chromophore/Catalyst Concepts for the Solar-Driven Reduction of Carbon Dioxide

One of the major scientific and technical challenges of this century is to develop chemical means to store solar energy in the form of fuels. This can be accomplished by developing light-absorbing and catalytic compounds that function cooperatively to rearrange the chemical bonds of feedstocks in a way that allows solar energy to be stored and released on demand. The research conducted during this project was directed toward addressing fundamental questions that underlie the conversion of CO 2 to a solar fuel using homogeneous molecular systems. The research focused particularly on developing methods for extracting the reducing equivalents for these photochemical conversions from H 2 , which is a renewable molecule sourced to water. The research followed two main lines. One effort focused on understanding the general principles that govern how light-absorbing molecules interact with independent H 2 oxidation and CO 2 reduction catalysts to produce a functional cycle for driving the energy-storing reverse water-gas-shift reaction with light. The second effort centered on developing the excited-state properties and H 2 activation chemistry of tungsten–alkylidyne complexes. These chromophores were found to be powerful excited-state reducing agents, which could be incorporated into light-light-harvesting assemblies, and to hold the potential to be regenerated using H 2 .

14 SOLAR ENERGY↗

Characterization of solution processed, p-doped films using hole-only devices and organic field-effect transistors

We report a solution-processed approach for a p-type doped hole transport layer in organic light emitting devices (OLEDs). UV-vis-NIR absorption spectra identified the charge transfer between the donor and acceptor in the solution processed doped films. Single carrier device and field-effect transistor were utilized as test vehicles to study the charge transport property and extract important parameters such as bulk mobile carrier concentration and mobility. OLEDs with p-type doped hole transport layer showed significant improvement in power efficiency up to 30% at the optimal doping ratio. This approach has the great potential to reduce the power consumption for OLED solid state lighting while lowering the cost and boosting the throughput of its manufacturing.

Swensen, James S.↗

Measurement of the generalized form factors near pion threshold via gamma*p --> npi^+ in CLAS

We extracted the multipoles near pion threshold for the first time at high momentum transfers (Q2) in the nπ+ final state channel. The dominance of the S-wave transverse multipole (E0+) is expected in this region, which allows us to access the new generalized form factors G1, G2 within the Light-Cone-Sum-Rule (LCSR) framework. In this analysis, we used one of the recent CLAS experimental data sets which utilized the high-energy polarized electron beam on unpolarized proton target using the 4π detector coverage. We measured the differential cross sections and extracted the multipoles using two methods, LCSR and multipole fit. Both methods show consistent results, which are almost Q2 independent.

43 PARTICLE ACCELERATORS↗

Conversion of above- and below-bandgap photons via InAs quantum dot media embedded into GaAs solar cell

Quantum dots (QDs) provide photovoltaic conversion of below-bandgap photons due to multistep electron transitions. QDs also increase conversion efficiency of the above-bandgap photons due to extraction of electrons from QDs via Coulomb interaction with hot electrons excited by high-energy photons. Nanoscale potential profile (potential barriers) and nanoscale band engineering (AlGaAs atomically thin barriers) allow for suppression of photoelectron capture to QDs. To study these kinetic effects and to distinguish them from the absorption enhancement due to light scattering on QDs, we investigate long, 3-μm base GaAs devices with various InAs QD media with 20 and 40 QD layers. Quantum efficiency measurements show that, at least at low doping, the multistep processes in QD media are strongly affected by the wetting layer (WL). The QD media with WLs provide substantial conversion of below-bandgap photons and for devices with 40 QD layers the short circuit current reaches 29.2 mA/cm{sup 2}. The QD media with band-engineered AlGaAs barriers and reduced wetting layers (RWL) enhance conversion of high-energy photons and decrease the relaxation (thermal) losses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theory of the Lamb Shift and fine structure in muonic {sup 4}He ions and the muonic {sup 3}He– {sup 4}He Isotope Shift

We provide an up to date summary of the theory contributions to the 2S → 2P Lamb shift and the fine structure of the 2P state in the muonic helium ion (μ{sup 4}He){sup +}. This summary serves as the basis for the extraction of the alpha particle charge radius from the muonic helium Lamb shift measurements at the Paul Scherrer Institute, Switzerland. Individual theory contributions needed for a charge radius extraction are compared and compiled into a consistent summary. The influence of the alpha particle charge distribution on the elastic two-photon exchange is studied to take into account possible model-dependencies of the energy levels on the electric form factor of the nucleus. We also discuss the theory uncertainty which enters the extraction of the {sup 3}He–{sup 4}He isotope shift from the muonic measurements. The theory uncertainty of the extraction is much smaller than a present discrepancy between previous isotope shift measurements. This work completes our series of n=2 theory compilations in light muonic atoms which we have performed already for muonic hydrogen, deuterium, and helium-3 ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying the Solubility of Boron Nitride Nanotubes and Sheets with Static Light Scattering and Refractometry

The dissolution of nanoparticles, particularly those containing boron, is an important area of interest for polymer nanocomposite formation and material development. In this work, the solubility of boron nitride nanotubes (BNNT), functionalized boron nitride nanotubes (FBNNT), and boron nitride sheets (BNZG) is quantified in toluene and THF with static light scattering, refractometry, UV vis spectroscopy, and physical observations. UV vis spectroscopy provides a method to determine the concentration and solubility limits of the solutions tested. Using light scattering, the second virial coefficient, A2, is determined and used to calculate , the solute solvent interaction parameter. The Hildebrand solubility parameter, , is then extracted from this data using the Hildebrand Scatchard Solution Theory. A list of potential good solvents based on the estimated value is provided for each nanoparticle. Single-walled carbon nanotubes (SWNTs) and prepolymers (EN4 and EN8) used to synthesize polyurethanes were also tested, because the published and molar attraction constants of these materials provided a selfconsistent check. The dn/dc of SWNTs and boron-containing particles was measured for the first time in this work. A solvent screen for BN-ZG provides additional information that supports the obtained and . Three systems were found to have values below 0.5 and were thermodynamically soluble: BNNT in THF, EN8 in THF, and EN8 in toluene.

Mutz, M↗

On the minimum dark matter mass testable by neutrinos from the Sun

We discuss a limitation on extracting bounds on the scattering cross section of dark matter with nucleons, using neutrinos from the Sun. If the dark matter particle is sufficiently light (less than about 4 GeV), the effect of evaporation is not negligible and the capture process goes in equilibrium with the evaporation. In this regime, the flux of solar neutrinos of dark matter origin becomes independent of the scattering cross section and therefore no constraint can be placed on it. We find the minimum values of dark matter masses for which the scattering cross section on nucleons can be probed using neutrinos from the Sun. We also provide simple and accurate fitting functions for all the relevant processes of GeV-scale dark matter in the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoelectron spectroscopy of CsK2Sb photocathode at Synchrotron Radiation Facility using vacuum transport system

As accelerators and electron microscopes become more advanced, high-performance photocathodes are required. In particular, Cesium potassium antimonide (CsK 2 Sb) photocathode is of interest because of its low emittance, excitability in visible light, and high quantum efficiency (QE). The challenge is its high susceptibility to environment that lead to low operating vacuum pressure and short lifetime/low extraction charge. To resolve these issues, it is necessary to understand the molecular structure of the cathode and its degradation mechanism. In this study, we transported CsK 2 Sb photocathode to a beamline of synchrotron radiation facility using a vacuum transport system for molecular structure analysis. Specifically, the cathode was deposited in an evaporation system at Nagoya University. We transported it to Aichi Synchrotron Radiation Center (Aichi SR) located 15 km away, and analyzed it in the depth direction by X-ray photoelectron spectroscopy (XPS) at BL7U. Based on the results, we quantitatively evaluated the composition ratios and stoichiometry of the cathode elements (Sb, K, Cs). A Cs ex-cess state of surface was observed at the surface, and it is consistent with previous studies. The intended atomic structure of CsK 2 Sb was formed only at a few nanometres of the surface on the Mo substrate. On the other hand, the CsK 2 Sb cathode structure on the graphene substrate was preserved further in the depth direction.

47 OTHER INSTRUMENTATION↗

Anisotropic electron damping and energy gap in Bi 2 ⁢Sr 2 ⁢CaCu 2 ⁢O 8+𝛿

The many-body electron-electron interaction in cuprates causes broadening of the electronic bands in 𝒌 space, leading to a deviation from the standard Fermi liquid. While a 𝒌-dependent anisotropic electronic scattering (𝒌-DAES) has been assessed by photoemission, its fingerprint in 𝑸 space has been scarcely considered. Here, we explore the 𝑸-dependent electron dynamics in optimally doped Bi 2⁢ Sr 2 ⁢CaCu 2 ⁢O 8+𝛿 through the evolution of low-energy charge excitations as measured by resonant inelastic x-ray scattering (RIXS). In the normal state, the RIXS spectra display a continuum of excitations down to 0 meV, while the superconducting state features a spectral weight suppression below 80 meV without any enhancement at higher energies. To interpret the energy and 𝑸 evolution of our data, we introduce a phenomenological expression of the charge susceptibility by including the 𝒌-DAES. We show that only the charge susceptibility with 𝒌-DAES captures the RIXS data, highlighting the importance of 𝒌-DAES when describing the 𝑸 dependence of charge excitations from 0 to a few eV scale. Furthermore, we also find that the inclusion of 𝒌-DAES is essential when quantitative parameters such as the electronic energy gap are extracted from RIXS data.

36 MATERIALS SCIENCE↗

Online regularization of Poincaré map of storage rings with Shannon entropy

A measurable chaos indicator is used as the online optimization objective in tuning a complicated nonlinear system—the National Synchrotron Light Source-II storage ring. Through analyzing the Shannon entropy in measured Poincaré maps, not only can the commonly used nonlinear characterizations be extracted, but more importantly, the chaos can be quantified and then used for an online regularization of these maps. The method itself is general and applicable to other tunable nonlinear systems as well. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

Quantitative Prediction of Uranium Speciation and Amidoxime Binding in Seawater from Advanced Simulation Techniques

The goal of this project was to quantitatively predict stability of uranium species and thermochemistry of uranium binding with amidoxime ligands in realistic seawater conditions. The specific aims of the project were: (i) determine the stable species of uranium and its solvation structure in realistic seawater conditions; also speciation and solvation of uranium's major competing species in seawater, vanadium; (ii) accurately predict the free energies (and thereby stability constants) of binding between uranium and amidoxime; (iii) accurately predict the reaction enthalpies and entropies of binding between uranium and amidoxime as well as between vanadium and amidoxime. Main results and conclusions are as follows. First-principles molecular dynamic simulations found that the structure of the Ca 2 UO 2 (CO 3 ) 3 complex is very stable and that one Ca ion binds to the center UO 2 (CO 3 ) 3 4- anion stronger than the other Ca ion. This finding suggests that using time-resolved EXAFS spectra may confirm the asymmetry in binding of the two Ca ions in the aqueous Ca 2 UO 2 (CO 3 ) 3 complex. To consider the common ions, solvation of the Ca 2 UO 2 (CO 3 ) 3 complex in seawater was simulated by classical molecular dynamics simulation. It was found that the structure of the Ca 2 UO 2 (CO 3 ) 3 complex is very stable in the model seawater. A Na+ ion was found to be closely associated with the Ca 2 UO 2 (CO 3 ) 3 complex by indirectly interacting with one axial oxygen atom of the UO 2 group bridged by a water molecule. In addition, the Na + ion interacts closely with one Ca 2+ ion than the other. The present simulations revealed the key role of common ions such as Na + in impacting the solvation, structure, and apparent charge of the Ca 2 UO 2 (CO 3 ) 3 complex in seawater. The sequential processes of UO 2 2+ binding with the three CO 3 2- groups and the two Ca 2+ ions in pure water and in 0.1 M NaCl were simulated by classical molecular dynamics with both the non-constrained brute-force approach and umbrella sampling. The simulated free energies show excellent agreement with the experiment. The coordination structures of UO 2 (CO 3 ) 3 4- and CaUO 2 (CO 3 ) 3 2- were found to be significantly affected by the presence of Na + ions, leading to a monodentate binding of a carbonate group to U and a water molecule entering the first coordination shell of U. To shed light on the binding between uranyl and glutardiamidoxime (H 2 B), an important model and state-of-the-art ligand for seawater uranium extraction, a suite of computational methods was employed. From molecular dynamics (MD) simulations, it was found that the binding configurations of B 2- with uranyl favor the twofold distorted η 2 binding between the oximate ends (C=N-O-) and U, while HB - prefers the chelating mode for the oximate end with the neutral end being solvated by water. The free energies of sequential ligand binding to form UO 2 B, [UO 2 B 2 ] 2- , and [UO 2 (HB)B] - were simulated with umbrella sampling and very good agreement with the experimental values was achieved, which corroborates the structural insights into the binding mode. State-of-the-art polymeric sorbents employ both amidoximate and carboxylate groups on the side chains to achieve optimal U uptake and selectivity, so we simulated the binding of a model amidoximate–carboxylate bifunctional ligand with uranyl. Classical MD and free-energy simulations in 0.5 M NaCl showed that the carboxylate group binds first to uranyl, leading to a loose intermediate state, and then, the amidoximate group binds, resulting in a more stable and tight chelate state. Binding of the second bifunctional ligand follows a similar process, and the two ligands prefer a trans configuration around the uranyl group. The simulated free energies indicate that the two bifunctional ligands bind with uranyl 14 kcal/mol stronger than the two ligands with only amidoximate groups, confirming an important synergy between amidoximate and carboxylate groups in binding uranyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics with polarized light ions at an EIC

Physics with polarized light nuclei such as He-3, and at JLab also vector- and tensor polarized deuterium, form an important part of the EIC program. Polarization, and a capability of high-resolution detection of all the outgoing target fragments in coincidence with the scattered electron and any particles produced in the current jet, allows the EIC to tackle physics at the crossroads between deep-inelastic scattering (QCD factorization, partonic structure) and low-energy nuclear structure (nuclear wave functions from many-body theory, spectral functions). A program with light nuclei at an EIC would include: 1) Neutron's partonic structure, essential for quark-flavor decomposition of the nucleon spin and the extraction of flavor non-singlet sea quark distributions. 2) The bound nucleon in QCD - the modifications of the single nucleon's structure due to nuclear binding and the quark/gluon origin of the nuclear force. 3) Collective quark/gluon fields. Coherent scattering, in which the nucleus remains intact, probes the quark/gluon field of the entire nucleus. Similar information comes from diffractive scattering on deuterium, where the tensor polarized structure function of is zero in single-nucleon scattering and precisely identifies the QCD double-scattering contribution.

Nadel-Turonski, Pawel↗

A method for the frequency control in time-resolved two-dimensional gigahertz surface acoustic wave imaging

We describe an extension of the time-resolved two-dimensional gigahertz surface acoustic wave imaging based on the optical pump-probe technique with periodic light source at a fixed repetition frequency. Usually such imaging measurement may generate and detect acoustic waves with their frequencies only at or near the integer multiples of the repetition frequency. Here we propose a method which utilizes the amplitude modulation of the excitation pulse train to modify the generation frequency free from the mentioned limitation, and allows for the first time the discrimination of the resulted upper- and lower-side-band frequency components in the detection. The validity of the method is demonstrated in a simple measurement on an isotropic glass plate covered by a metal thin film to extract the dispersion curves of the surface acoustic waves.

36 MATERIALS SCIENCE↗

SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus or minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations

Purpose: The purposes of this work were: (1) To determine if a spectral method can accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for situations where the Cerenkov light is dominant over the scintillation light and (2) to develop a procedural guideline for accurately determining the calibration factors of PSDs. Methods: The authors demonstrate, by using the equations of the spectral method, that the condition for accurately correcting the effect of Cerenkov light is that the ratio of the two calibration factors must be equal to the ratio of the Cerenkov light measured within the two different spectral regions used for analysis. Based on this proof, the authors propose two new procedures to determine the calibration factors of PSDs, which were designed to respect this condition. A PSD that consists of a cylindrical polystyrene scintillating fiber (1.6 mm{sup 3}) coupled to a plastic optical fiber was calibrated by using these new procedures and the two reference procedures described in the literature. To validate the extracted calibration factors, relative dose profiles and output factors for a 6 MV photon beam from a medical linac were measured with the PSD and an ionization chamber. Emphasis was placed on situations where the Cerenkov light is dominant over the scintillation light and on situations dissimilar to the calibration conditions. Results: The authors found that the accuracy of the spectral method depends on the procedure used to determine the calibration factors of the PSD and on the attenuation properties of the optical fiber used. The results from the relative dose profile measurements showed that the spectral method can correct the Cerenkov light effect with an accuracy level of 1%. The results obtained also indicate that PSDs measure output factors that are lower than those measured with ionization chambers for square field sizes larger than 25x25 cm{sup 2}, in general agreement with previously published Monte Carlo results. Conclusions: The authors conclude that the spectral method can be used to accurately correct the Cerenkov light effect in PSDs. The authors confirmed the importance of maximizing the difference of Cerenkov light production between calibration measurements. The authors also found that the attenuation of the optical fiber, which is assumed to be constant in the original formulation of the spectral method, may cause a variation of the calibration factors in some experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗