Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Life Support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Integrated developmental model of life-support capabilities in wheat

The objective of this project was to develop a model for CO2, O2, H2O, and nitrogen use during the life cycle of wheat. Spreadsheets and accompanying graphs were developed to illustrate plant population reactions to environmental parameters established in the Controlled Ecological Life Support System (CELSS) program at Kennedy Space Center, Fl. The spreadsheets and graphs were produced using validated biomass production chamber (BPC) data from BWT931. Conditions of the BPC during the 83 day plant growth period were as follows: The BPC area is 27.8 m(exp 2), volume is 113 m(exp 3). Temperatures during the 83 day plant growth period ranged from 16.3 to 24.8 C during the light cycle (except for day 69, when the minimum and maximum temperatures were 7.7 C and 7.9 C, respectively) and 14.5 C and 23.6 C during the dark cycle (except for day 49, when the minimum and maximum temperatures were 11.1 C and 11.3 C, respectively). Relative humidity was 85 percent for the first seven days of plant growth, and 70 percent thereafter. The plant leaf canopy area was 10 m(exp 2). Presented is a list and explanation of each spreadsheet and accompanying graph(s), conditions under which the data were collected, and formulas used to obtain each result.

Darnell, R. L.↗

Progress in the Development of Direct Osmotic Concentration Wastewater Recovery Process for Advanced Life Support Systems

Direct osmotic concentration (DOC) has been identified as a high potential technology for recycling of wastewater to drinking water in advanced life support (ALS) systems. As a result the DOC process has been selected for a NASA Rapid Technology Development Team (RTDT) effort. The existing prototype system has been developed to a Technology Readiness Level (TRL) 3. The current project focuses on advancing the development of this technology from TRL 3 to TRL 6 (appropriate for human rated testing). A new prototype of a DOC system is been designed and fabricated that addresses the deficiencies encountered during the testing of the original system and allowing the new prototype to achieve TRL 6. Background information is provided about the technologies investigated and their capabilities, results from preliminary tests, and the milestones plan and activities for the RTDT program intended to develop a second generation prototype of the DOC system.

Cath, Tzahi Y.↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A pervious TCV version with a linear actuator and diverter valve has been tested extensively to attempt to control the flow accurately. The previous TCV diverter valve has a non-linear flow response relative to valve position and has struggled to accurately meet the setpoints desired for precision thermal control. While many diverter valve design variations have been attempted, previous designs have all had difficulty in meeting set points. Additionally, high precision machining is required for these diverter valves to create a metal-on-metal seal which has its own drawbacks and doesn’t always meet requirements for internal leakage. This metal compression seal also requires stalling the linear actuator to load the seal in compression or tension which has demonstrated valve sticking failures when stalled. The xEMU PLSS TCV implements a new approach and design for a TCV which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. A new geometric design modification to the ball outlet can create a set-able orifice like hole which is more predictable at controlling flow than using an annulus with the previous diverter valve. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the space suit Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure for the crew member during pre-breathe, extra-vehicular activity (EVA), post EVA airlock operations, and decompression sickness treatment. The last time a spacesuit oxygen regulator was designed was for the Space Shuttle Program EMU. The regulator & EMU were then used on the International Space Station (ISS) with no significant changes to the regulator throughout its life. This xEMU PLSS spacesuit oxygen regulator implements many elements of the previous EMU Secondary Oxygen Pack (SOP) design while integrating numerous new improvements and changes. There are changes both to the high-level regulator architecture approach in the suit itself, in addition to modernizations with electrical motor control & sensing. For architecture, there are two oxygen regulators for each space suit, a primary and secondary that are nearly identical to each other and have the same maximum design pressure of 3750 Pounds per Square Inch Absolute (PSIA). The primary regulator provides nominal pressure during EVA, while the secondary provides a backup pressure only in case of primary regulator failure or if an emergency purge of the suit oxygen is required. The design was based originally off of the secondary oxygen regulator on the EMU which utilizes a two-stage regulator to improve safety and controllability. The xEMU PLSS Oxygen Regulator development started with a modification to add a linear actuator to the design to control the downstream pressure electronically instead of a manual control with a wire linkage system used with the EMU. The design was iterated to include a Monel body for oxygen fire safety, and sensors for pressure verification at each stage. Then the regulator design was packaged to fit into the xEMU PLSS envelope. Development included extensive testing which brought to light some issues with the design which were addressed at each stage of development. This paper will review the design history, development, testing results, and lessons learned designing the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Comparison of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Metal-oxide absorbents (MOAs) have a demonstrated capability for removal of both metabolic CO2 and H2O from breathing atmospheres, simplifying portable life support system (PLSS) design and affording reversible operation for regeneration. Attention is presently given to the comparative performance levels obtained by silver-oxide-based and silver/zinc-oxide-based systems, which also proved to be longer-lasting than the silver oxide-absorber system. The silver/zinc system is found to substantially simplify the ventilation loop of a prospective Space Station Freedom PLSS.

Stonesifer, Greg T.↗

Life-Support-System Analyzer

Paper describes software system, called Generic Modular Flow Schematic (GMFS), developed for use in synthesis, mathematical modeling, and analysis of life-support systems aboard spacecraft, ranging from simple open-loop configurations to complex closed-loop ones. GMFS also compares alternative systems.

Seshan, Panchalam K.↗

Proposed Schematics and Modeling Results for a Lunar Portable Life Support System

The Constellation Space Suit Element (CSSE) is an integrated assembly made up of primarily a Pressure Garment System (PGS) and a Portable Life Support System (PLSS). The PLSS is further composed of an oxygen (O2) subsystem, a ventilation subsystem, and a thermal subsystem. This paper baselines a detailed schematic of the CSSE PLSS to provide a basis for current and future CSSE PLSS development efforts. Both context diagrams and detailed schematics describe the hardware components and overall functions for all three of the PLSS subsystems. Additionally, PLSS functions are presented for multiple operational scenarios as follows: 1) Nominal Extravehicular Activity (EVA) Mode; 2) Umbilical Modes; a) No Recharge, b) With Recharge; 3) Decompression Sickness (DCS) Treatment Mode; 4) Buddy Mode; 5) Secondary O2 Modes; a) Helmet Purge; b) Suit Purge; c) Operational; and 5) PLSS Removed Umbilical Mode. A performance modeling effort is being performed to provide a preliminary confirmation of this layout and the current state of the thermal hydraulic modeling efforts being conducted for the PLSS is presented. The goal of these efforts is to provide realistic simulations of the PLSS under various modes of operation. Modeling approaches and assumptions are discussed as well as component model descriptions. Results from the models are included that show PLSS operations at steady-state and transient conditions. Finally, conclusions and recommendations are offered that summarize results, identify PLSS design weaknesses uncovered during review of the analysis results, and propose areas for improvement to increase model fidelity and accuracy.

Conger, Bruce↗

Humidifier Development and Applicability to the Next Generation Portable Life Support System

A development effort at the NASA Johnson Space Center investigated technologies to determine whether a humidifier would be required in the Portable Life Support System (PLSS) envisioned for future exploration missions. The humidifier has been included in the baseline PLSS schematic since performance testing of the Rapid Cycle Amine (RCA) indicates that the RCA over-dries the ventilation gas stream. Performance tests of a developmental humidifier unit and commercial off-the-shelf (COTS) units were conducted in December 2009. Following these tests, NASA revisited the need for a humidifier via system analysis. Results of this investigation indicate that it is feasible to meet humidity requirements without the humidifier if other changes are made to the PLSS ventilation loop and the Liquid Cooling and Ventilation Garment (LCVG).

Conger, Bruce↗

Humidifier Development and Applicability to the Next Generation Portable Life Support System

A development effort at the NASA Johnson Space Center investigated technologies to determine whether a humidifier would be required in the Portable Life Support System (PLSS) envisioned for future exploration missions. The humidifier has been included in the baseline PLSS schematic since performance testing of the Rapid Cycle Amine (RCA) indicates that the RCA over-dries the ventilation gas stream. Performance tests of a developmental humidifier unit and commercial off-the-shelf (COTS) units were conducted in December 2009. Following these tests, NASA revisited the need for a humidifier via system analysis. Results of this investigation indicate that it is feasible to meet humidity requirements without the humidifier if other changes are made to the PLSS ventilation loop and the Liquid Cooling and Ventilation Garment (LCVG).

Conger, Bruce C.↗

ISS Regenerative Life Support: Challenges and Success in the Quest for Long-Term Habitability in Space

The International Space Station's (ISS) Regenerative Environmental Control and Life Support System (ECLSS) was launched in 2008 to continuously recycle urine and crew sweat into drinking water and oxygen using brand new technologies. This functionality was highly important to the ability of the ISS to transition to the long-term goal of 6-crew operations as well as being critical tests for long-term space habitability. Through the initial activation and long-term operations of these systems, important lessons were learned about the importance of system redundancy and operational workarounds that allow Systems Engineers to maintain functionality with limited on-orbit spares. This presentation will share some of these lessons learned including how to balance water through the different systems, store and use water for use in system failures and creating procedures to operate the systems in ways that they were not initially designed to do.

Bazley, Jesse↗

NASA's Interests in Bioregenerative Life Support

NASA and other space agencies and around the world have had long-standing interest in using plants and biological approaches for regenerative life support. In particular, NASA's Kennedy Space Center, has conducted research in this area for over 30 years. One unique aspect to this testing was NASA's Biomass Production Chamber, which had four vertically stacked growing shelves inside a large, 113 cubic meter chamber. This was perhaps one of the first working examples of a vertical agriculture system in the world. A review of some of this research along with some of the more salient findings will be presented.

Wheeler, Raymond M.↗