Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source

X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5 × 10 11 photons shot –1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ≈0.47% below 9 keV is characterized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Merging single-shot XFEL diffraction data from inorganic nanoparticles: a new approach to size and orientation determination

X-ray free-electron lasers (XFELs) provide new opportunities for structure determination of biomolecules, viruses and nanomaterials. With unprecedented peak brilliance and ultra-short pulse duration, XFELs can tolerate higher X-ray doses by exploiting the femtosecond-scale exposure time, and can thus go beyond the resolution limits achieved with conventional X-ray diffraction imaging techniques. Using XFELs, it is possible to collect scattering information from single particles at high resolution, however particle heterogeneity and unknown orientations complicate data merging in three-dimensional space. Using the Linac Coherent Light Source (LCLS), synthetic inorganic nanocrystals with a core–shell architecture were used as a model system for proof-of-principle coherent diffractive single-particle imaging experiments. To deal with the heterogeneity of the core–shell particles, new computational methods have been developed to extract the particle size and orientation from the scattering data to assist data merging. The size distribution agrees with that obtained by electron microscopy and the merged data support a model with a core–shell architecture.

36 MATERIALS SCIENCE↗

Single-particle imaging without symmetry constraints at an X-ray free-electron laser

The analysis of a single-particle imaging (SPI) experiment performed at the AMO beamline at LCLS as part of the SPI initiative is presented here. A workflow for the three-dimensional virus reconstruction of the PR772 bacteriophage from measured single-particle data is developed. It consists of several well defined steps including single-hit diffraction data classification, refined filtering of the classified data, reconstruction of three-dimensional scattered intensity from the experimental diffraction patterns by orientation determination and a final three-dimensional reconstruction of the virus electron density without symmetry constraints. The analysis developed here revealed and quantified nanoscale features of the PR772 virus measured in this experiment, with the obtained resolution better than 10 nm, with a clear indication that the structure was compressed in one direction and, as such, deviates from ideal icosahedral symmetry.

47 OTHER INSTRUMENTATION↗

SpeckleNN: a unified embedding for real-time speckle pattern classification in X-ray single-particle imaging with limited labeled examples

With X-ray free-electron lasers (XFELs), it is possible to determine the three-dimensional structure of noncrystalline nanoscale particles using X-ray single-particle imaging (SPI) techniques at room temperature. Classifying SPI scattering patterns, or `speckles', to extract single-hits that are needed for real-time vetoing and three-dimensional reconstruction poses a challenge for high-data-rate facilities like the European XFEL and LCLS-II-HE. Here, we introduce SpeckleNN, a unified embedding model for real-time speckle pattern classification with limited labeled examples that can scale linearly with dataset size. Trained with twin neural networks, SpeckleNN maps speckle patterns to a unified embedding vector space, where similarity is measured by Euclidean distance. We highlight its few-shot classification capability on new never-seen samples and its robust performance despite having only tens of labels per classification category even in the presence of substantial missing detector areas. Without the need for excessive manual labeling or even a full detector image, our classification method offers a great solution for real-time high-throughput SPI experiments.

47 OTHER INSTRUMENTATION↗

First Soft X-ray Quantum Efficiency Measurements on Microwave Annealed Thin-Entrance Window Sensors

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. In addition, there are other light sources such as the FERMI, EuXFEL, and FLASH XFELs, as well as numerous synchrotrons such as the ALS, where soft x-ray science would benefit from detectors with higher quantum efficiency in the 20 eV to 1.5KeV range.A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. Previously, SRP and SIMS measurements were used to characterize the shallow dopant profile, and sensors with the new entrance window process were deployed successfully to measure an Fe-55 x-ray spectrum. For the first time, we present quantum efficiency measurement for soft x-rays. Furthermore, the resulting estimate of the entrance window is 20nm for an arsenic implanted entrance window and 55nm for a boron implanted entrance window.

47 OTHER INSTRUMENTATION↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Optical damage considerations in the design of the matter in extreme condition upgrade (MEC-U) laser systems

The Matter in Extreme Conditions Upgrade (MEC-U) project is a major upgrade to the MEC instrument of the LINAC Coherent Light Source (LCLS) X-ray free electron laser (XFEL) user facility at SLAC National Accelerator Laboratory. Here, the envisioned MEC upgrade will significantly enhance the capabilities of the pump laser sources in current MEC experimental station, boosting the energy of the nanosecond shock driver from 100 J to the kJ level, and increasing the power and repetition rate of the short pulse laser from 25 TW at 5 Hz to 1 PW at 10 Hz rate. Building such high energy/power pump laser systems presents challenges to minimize and mitigate against laser-induced optical damage. Here, as part of the system design, we have identified the optics at high-risk to damage and we have designed the laser systems to mitigate against these damage risks to ensure sustained facility operation.

Coating↗

SU-F-T-294: The Analysis of Gamma Criteria for Delta4 Dosimetry Using Statistical Process Control

Purpose: To evaluate the sensitivity of gamma criteria for patient-specific volumetric modulated arc therapy(VMAT) quality assurance of the Delta{sup 4} dosimetry program using the statistical process control(SPC) methodology. Methods: The authors selected 20 patient-specific VMAT QA cases which were undertaken MapCHECK and ArcCHECK with gamma pass rate better than 97%. The QAs data were collected Delta4 Phantom+ and Elekta Agility six megavolts without using an angle incrementer. The gamma index(GI) were calculated in 2D planes with normalizing deviation to local dose(local gamma). The sensitivity of the GI methodology using criterion of 3%/3mm, 3%/2mm and 2%/3mm was analyzed with using process acceptability indices. We used local confidence(LC) level, the upper control limit(UCL) and lower control limit(LCL) of I-MR chart for process capability index(Cp) and a process acceptability index (Cpk). Results: The lower local confidence levels of 3%/3mm, 3%/2mm and 2%/3mm were 92.0%, 83.6% and 78.8% respectively. All of the calculated Cp and Cpk values that used LC level were under 1.0 in this study. The calculated LCLs of I-MR charts were 89.5%, 79.0% and 70.5% respectively. These values were higher than 1.0 which means good quality of QA. For the generally used lower limit of 90%, we acquired over 1.3 of Cp value for the gamma index of 3%/3mm and lower than 1.0 in the rest of GI. Conclusion: We applied SPC methodology to evaluate the sensitivity of gamma criteria and could see the lower control limits of VMAT QA for the Delta 4 dosimetry and could see that Delta 4 phantom+ dosimetry more affected by the position error and the I-MR chart derived values are more suitable for establishing lower limits. Acknowledgement: This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (No. 2015R1D1A1A01060463)

60 APPLIED LIFE SCIENCES↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LCLS2

This is the LCLS II development repository developed at SLAC National Accelerator Laboratory.

Dubrovin, Mikhail↗

slaclab/l2Mps

Driver for the LCLS-2 Machine Protection Systems (MPS), which is based on the ATCA High Performance System (HPS).

Vasquez, Jesus↗

slaclab/lcls-cu-inj-live

This project contains the tools for running the live online model for the lcls-cu injector. The model is served over EPICS and the client uses bokeh for web-based rendering.

Garrahan, Jacqueline↗