Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

The upcoming Jefferson Lab K-Long experiment at Hall D will require unique beam conditions with a much lower bunch repetition rate and atypically high bunch charge. To optimize the Continuous Electron Beam Accelerator Facility (CEBAF) injector for this experiment, we performed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) to determine the magnetic elements and RF settings necessary for the K-long bunch charge (0.64 pC) at 200 kV. We also investigated the transmission and beam characteristics of low to high charge per bunch electron beams through the injector for simultaneous operations of all four CEBAF Halls and characterized the transmission as a function of the photocathode laser spot size and pulse length. Our findings provide valuable insights into optimizing the CEBAF injector for the Jefferson Lab K-Long experiment, as well as for other experiments with similar beam conditions

Kazimi, R.↗

HE Production Update at JLab - Introducing an Enhanced Nitrogen Purge for Clean String Assembly

A major limitation to cryomodule performance is field emission caused by particulates within the superconducting cavities. To reduce contamination of the inner surfaces during assembly in a cleanroom, the whole string can be connected to a purge system, which maintains a constant overpressure of dry, clean nitrogen gas. Following successes of similar systems at XFEL and Fermilab, Jefferson Lab followed this example for the production of LCLS-II HE cryomodules. Implementing this system required new procedures, infrastructure, and hardware, as well as significant testing of the system before production began. This paper will summarize the implemented controls and procedures, including lessons learned from Fermilab, as well as the results of mock-up tests. Based on the latter, the system was used to assemble the first article string in April 2022, and was also used during a rework required due to issues with cold FPC ceramics two months later. The benefits of using a purge system with regards to procedure, time savings, and added flexibility for potential rework have already proven to provide a significant improvement for the production of LCLS-II-HE cryomodules at Jefferson Lab.

Owen, P. D.↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

K-Long Facility for JLab and its Scientific Potential

Our main interest in creating a secondary high-quality KL-beam is to investigate hyperon spectroscopy through both formation and production processes. We propose to study two-body reactions induced by the KL-beam on the proton target. The experiment should measure both differential cross sections and self-analyzed polarizations of the produced Λ-, Σ-, and Ξ-hyperons using the GlueX detector at the Jefferson Lab Hall D. New data will greatly constrain partial-wave analysis and reduce modeldependent uncertainties in the extraction of strange resonance properties, providing a new benchmark for comparisons with QCD-inspired models and LQCD calculations. The measurements will span c.m. cos θ from -0.95 to 0.95 in c.m. range above W = 1490 MeV and up to 4000 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin physics with CLAS and CLAS12

An extensive experimental program to measure the spin structure of the nucleon has been conducted in Hall B at Jefferson Lab with the CEBAF Large Acceptance Spectrometer (CLAS) in the last decade. Using a longitudinally polarized beam scattering off longitudinally polarized NH{sub 3} and ND{sub 3} targets, inclusive Deep Inelastic Scattering (DIS), Semi-Inclusive DIS (SIDIS) and DVCS experiments were carried out that make a significant contributions to the existing data. The inclusive double spin asymmetry A{sub ||} was measured over a large range in Q{sup 2} and W, providing data of impressively high precision that give a better understanding of the structure of the nucleon in the DIS and the valence quarks regions. Using parameterizations A2 and F1 from world data, the virtual photon asymmetry A1 and the structure function g1 were extracted in a Q{sup 2} range from 0.05 to 5 GeV{sup 2} and a W range from 1.08 to 3.0 GeV. As a result of the extended kinematical range, first moments of structure functions were measured over a large range in Q{sup 2} and duality was tested. Furthermore, newly proposed experiments, using an upgraded accelerator at Jefferson Laboratory and an improved CLAS detector (CLAS12), are expected to increase the statistical precision of the current measurements and extend them to kinematic regions presently not accessible, such as high x. This will improve significantly our knowledge of the structure of the nucleon, including parton distribution functions, duality and higher twists contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q{sup 2}

A high precision measurement of the proton elastic form factor ratio {mu}{sub p}G{sub Ep}/G{sub Mp} in the range Q{sup 2} = 0.3-0.7 GeV{sup 2}/c{sup 2} was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q{sup 2} range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller G{sub Ep} at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deeply Virtual Exclusive Reactions with CLAS

Deeply virtual exclusive reactions offer an unique opportunity to study the structure of the nucleon at the parton level as one has access to Bjorken x{sub B} and momentum transfer to the nucleon t at the same time. Such processes can reveal much more information about the structure of the nucleon than either inclusive electroproduction or elastic form factors alone. Dedicated experiments to study Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) have been carried out in Hall B at Jefferson Lab. DVCS helicity–dependent and helicity–independent cross sections and beam spin asymmetries have been measured with CLAS, as well as cross sections and asymmetries for the {pi}{sup }0, {eta} , {rho}{sup }0, {rho}{sup +}, {omega} and {phi} for exclusive electroproduction. The data were taken in a wide kinematic range in Q{sup 2}=1–4.5 GeV{sup 2}, x{sub B}=0.1–0.5, and {absval t} up to 2 GeV{sup 2}. We will discuss the interpretation of these data in terms of traditional Regge and Generalized Parton Distributions (GPDs) models. The successful description of the recent CLAS pseudoscalar meson exclusive production data by GPD-based model provides a unique opportunity to access the transversity GPDs. We view the work presented in this report as leading into the program of the Jefferson Lab 12 GeV upgrade. The increased energy and luminosity will allow us to acquire data at much higher Q{sup 2} and x{sub B}, and perform Rosenbluth L/T separations of the cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged Pion Photoproduction

We extracted the differential cross section for the {gamma}n{yields}{pi}{sup -}p process from a deuterium target using the CLAS detector at Jefferson Lab in Hall B for photon energies between 1.0 and 3.5 GeV and pion center-of-mass (c.m.) angles ({theta}{sub c.m.}) between 50 deg. and 115 deg. We confirm a previous indication of a broad enhancement around a c.m. energy ({radical}(s)) of 2.1 GeV at {theta}{sub c.m.} = 90 deg. in the scaled differential cross section, s{sup 7}(d{sigma}/dt) and a rapid fall-off in a center-of-mass energy region of about 400 MeV following the enhancement. Our data show an angular dependence of this enhancement as the suggested scaling region is approached for {theta}{sub c.m.} from 70 deg. to 105 deg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A test of local Lorentz invariance with Compton scattering asymmetry

Here, we report on a measurement of the constancy and anisotropy of the speed of light relative to the electrons in photon-electron scattering. We also used the Compton scattering asymmetry measured by the new Compton polarimeter in Hall~C at Jefferson Lab to test for deviations from unity of the vacuum refractive index ($n$). For photon energies in the range of 9 - 46 MeV, we obtain a new limit of $1-n < 1.4 \times 10^{-8}$. In addition, the absence of sidereal variation over the six month period of the measurement constrains any anisotropies in the speed of light. These constitute the first study of Lorentz invariance using Compton asymmetry. Within the minimal standard model extension framework, our result yield limits on the photon and electron coefficients $\tilde{\kappa}_{0^+}^{YZ}, c_{TX}, \tilde{\kappa}_{0^+}^{ZX}$, and $c_{TY}$. Though, these limits are several orders of magnitude larger than the current best limits, they demonstrate the feasibility of using Compton asymmetry for tests of Lorentz invariance. For future parity violating electron scattering experiments at Jefferson Lab we will use higher energy electrons enabling better constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scaling Phenomenology in Meson Photoproduction from CLAS

In the high energy limit, perturbative QCD predicts that hard scattering amplitudes should follow simple scaling laws. For hard scattering at 90 deg., we show that experiments support this prediction even in the ''medium energy'' regime of 2.3 GeV{<=}{radical}(s){<=}2.84 GeV, as long as there are no s-channel resonances present. Our data consists of high statistics measurements for five different exclusive meson photoproduction channels (p{omega}, p{eta}, p{eta}', K{sup +{Lambda}}and K{sup +{Sigma}0}) recently obtained from CLAS at Jefferson Lab. The same power-law scaling also leads to ''saturated'' Regge trajectories at high energies. That is, at large -t and -u, Regge trajectories must approach constant negative integers. We demonstrate the application of saturated Regge phenomenology by performing a partial wave analysis fit to the {gamma}yp{yields}p{eta}'differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Observation of Quark-Hadron Duality in the Free Neutron {ital F}{sub 2} Structure Function

Using the recently published data from the BONuS(Barely Off-shell Nucleon Structure) experiment at Jefferson Lab, which utilized a spectator tagging technique to extract the inclusive electron-free neutron scattering cross section, we obtain the first direct observation of quark-hadron duality in the neutron F-2 structure function. The data are used to reconstruct the lowest few (N = 2, 4, and 6) moments of F-2 in the three prominent nucleon resonance regions, as well as the moments integrated over the entire resonance region. Comparison with moments computed from global parametrizations of parton distribution functions suggest that quark-hadron duality holds locally for the neutron in the second and third resonance regions down to Q(2) approximate to 1 GeV2, with violations possibly up to 20% observed in the first resonance region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The First Measurement of Neutron Transversity on a Transversely Polarized {sup 3}He Target

We recently measured the neutron target single spin asymmetry in the semi-inclusive deep inelastic {sup 3}He{sup {up_arrow}}(e,e'{pi}{sup {+-}})X reactions with a transversely polarized {sup 3}He target. The experiment was performed in Hall A at Jefferson Lab from October 2008 to February 2009. Pions were detected in the high-resolution spectrometer in coincidence with scattered electrons detected by the BigBite spectrometer. The kinematic coverage focuses on the valence quark region, x = 0.1-0.4, at Q{sup 2} = 1-3 (GeV/c){sup 2}. With good particle identifications using a RICH detector and an aerogel Cherenkov counter, data on kaons were obtained at the same time. The data from this experiment, when combined with the world data, will provide constraints on the Transversity and Sivers distributions on both u-quark and d-quark in the valence quark region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of silicon photomultipliers and their applications to GlueX calorimetry

The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pion structure function from leading neutron electroproduction and SU(2) flavor asymmetry

In this paper, we examine the efficacy of pion exchange models to simultaneously describe leading neutron electroproduction at HERA and the $\bar{d}-\bar{u}$ flavor asymmetry in the proton. A detailed $\chi^2$ analysis of the ZEUS and H1 cross sections, when combined with constraints on the pion flux from Drell-Yan data, allows regions of applicability of one-pion exchange to be delineated. The analysis disfavors several models of the pion flux used in the literature, and yields an improved extraction of the pion structure function and its uncertainties at parton momentum fractions in the pion of $4 \times 10^{-4} \lesssim x_\pi \lesssim 0.05$ at a scale of $Q^2$=10 GeV$^2$. Also, we provide estimates for leading proton structure functions in upcoming tagged deep-inelastic scattering experiments on the deuteron with forward protons, based on the fit results, at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Electron- and positron-proton elastic scattering in CLAS

There is a significant disagreement between measurements of the proton electric form factor, G{sup p}{sub E}, using Rosenbluth separations and polarization transfer. This disagreement, if not explained, could pose a fundamental challenge to our understanding of electron scattering or proton structure. Two-photon exchange (TPE) processes, although not fully calculable, are the most likely explanation of this disagreement. We will definitively test this assertion by comparing the electron-proton and positron-proton elastic scattering cross section in the Jefferson Lab CLAS. We will make a mixed identical electron and positron tertiary beam by passing a 5.5 GeV primary electron beam through a radiator to make a photon beam and then passing the photon beam through a converter to make electron-positron pairs. Measuring the elastic cross sections simultaneously using identical lepton beams should significantly reduce systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗