Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Carbon monoxide detector

A sensitive carbon monoxide detector, developed specifically for spacecraft use, is described. An instrument range of 0 to 60 ppm CO in air was devised. The fuel cell type detector is used as a highly sensitive electrolysis cell for electrochemically detecting gases. The concept of an electrochemical CO detector is discussed and the CO oxidation behavior in phosphoric and sulfuric acid electrolytes is reported.

Holleck, G. L.↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

Monolithically-Fabricated Tunable Long-Wave Infrared Detectors Based on Dynamic Graphene Metasurfaces.

In this paper, the design, fabrication, and characterization of an actively tunable long-wave infrared detector, made possible through direct integration of a graphene-enabled metasurface with a conventional type-II superlattice infrared detector, are reported. This structure allows for post-fabrication tuning of the detector spectral response through voltage-induced modification of the carrier density within graphene and, therefore, its plasmonic response. These changes modify the transmittance through the metasurface, which is fabricated monolithically atop the detector, allowing for spectral control of light reaching the detector. Importantly, this structure provides a fabrication-controlled alignment of the metasurface filter to the detector pixel and is entirely solid-state. Using single pixel devices, relative changes in the spectral response exceeding 8% have been realized. These proof-of-concept devices present a path toward solid-state hyperspectral imaging with independent pixel-to-pixel spectral control through a voltage-actuated dynamic response.

47 OTHER INSTRUMENTATION↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

Space Detectors for Gamma Rays (100 MeV-100 GeV): from Egret to Fermi LAT

The design of spaceborne high-energy (E is greater than 100 MeV) gamma-ray detectors depends on two principal factors: (1) the basic physics of detecting and measuring the properties of the gamma rays; and (2) the constraints of operating such a detector in space for an extended period. Improvements in technology have enabled major advances in detector performance, as illustrated by two successful instruments, EGRET on the Compton Gamma Ray Observatory and LAT on the Fermi Gamma-ray Space Telescope.

Gamma rays Detectors Space↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NICMOS Spectroscopy of HD 189733b

Spectral features corresponding to methane and water opacity were reported based on transmission spectroscopy of HD 189733b with Hubble/NICMOS. Recently, these data, and a similar data set for XO-1b, have been reexamined in Gibson et al. 2010, who claim they cannot reliably reproduce prior results. We examine the methods used by the Gibson team and identify two specific issues that could act to increase the formal uncertainties and to create instability in the minimization process. This would also be consistent with the GPA10 finding that they could not identify a way to select among the several instrument models they constructed. In the case of XO-1b, the Gibson team significantly changed the way in which the instrument model is defined (both with respect to the three approaches they used for HD 189733b, and the approach used by previous authors); this change, which omits the effect of the spectrum position on the detector, makes direct intercomparison of results difficult. In the experience of our group, the position of the spectrum on the detector is an important element of the instrument model because of the significant residual structure in the NICMOS spectral flat field. The approach of changing instrument models significantly complicates understanding the data reduction process and interpreting the results. Our team favors establishing a consistent method of handling NICMOS instrument systematic errors and applying it uniformly to data sets.

infrared↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

CCD camera systems and support electronics for a White Light Coronagraph and X-ray XUV solar telescope

Two instruments, a White Light Coronagraph and an X-ray XUV telescope built into the same housing, share several electronic functions. Each instrument uses a CCD as an imaging detector, but due to different spectral requirements, each uses a different type. Hardware reduction, required by the stringent weight and volume allocations of the interplanetary mission, is made possible by the use of a microprocessor. Most instrument functions are software controlled with the end use circuits treated as peripherals to the microprocessor. The instruments are being developed for the International Solar Polar Mission.

Harrison, D. C.↗

Design and test of the Near Infrared Mapping Spectrometer /NIMS/ focal plane for the Galileo Jupiter Orbiter mission

A Near Infrared Mapping Spectrometer (NIMS) will fly past Jupiter on the Galileo spacecraft in 1982. The infrared detector assembly (focal plane) used in the NIMS instrument is to be passively cooled to 80 K by radiation into space. The focal plane contains 15 InSb and two silicon detectors, each with an associated dual J-FET preamp and feedback resistor. Preliminary fabrication and test experience will be described for an experimental five-channel hybrid detector assembly. Measurements of spectral noise density along with a plasma cleaning technique will also be described. The final NIMS focal plane will contain much of the design experience gained from the experimental hybrid detector assembly.

Bailey, G.↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1986 Nuclear Science Symposium, 33rd, and 1986 Symposium on Nuclear Power Systems, 18th, Washington, DC, Oct. 29-31, 1986, Proceedings

Papers are presented on space, low-energy physics, and general nuclear science instrumentations. Topics discussed include data acquisition systems and circuits, nuclear medicine imaging and tomography, and nuclear radiation detectors. Consideration is given to high-energy physics instrumentation, reactor systems and safeguards, health physics instrumentation, and nuclear power systems.

Stubblefield, F. W.↗