Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A cantilevered liquid-nitrogen-cooled silicon mirror for the Advanced Light Source Upgrade

This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.

47 OTHER INSTRUMENTATION↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated Performance of the Micro-Pocket Fission Detector in the Advanced Test Reactor Critical Facility

The Micro-Pocket Fission Detector (MPFD) is a small-form–factor real-time fission chamber. MPFD performance has been simulated in the Advanced Test Reactor Critical Facility (ATRC), located at Idaho National Laboratory (INL). Here, the neutron and gamma-ray flux profiles and magnitudes were simulated using Monte Carlo N-Particle (MCNP) in the near-core B-8 irradiation position. These simulations were performed at 69 discrete axial locations inside the B-8 position for three separate orientations of the nearby hafnium outer shim control cylinders and at a power level of 700 Wth. The resulting neutron and gamma-ray flux values were used to determine the MPFD response for various fissile masses and detector gas pressures. The optimal gas-operating pressure was determined to be between 30 and 60 psig. The required fissile-layer mass was determined to be between 1–2 µg of 235 U. Additionally, the gamma-ray to fission-fragment interaction rate was determined to be 4.42 × 10 -3 with average energy deposition for gamma rays and fission fragments in 30 psig argon gas to be 1 keV and 9.5 MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave Tank Testing Report for Controls Validation of a Heaving Point Absorber

The core objectives of this project is to improve the power capture of three different wave energy conversion (WEC) devices by more than 50% using an advanced control system and validate the attained improvements using wave tank and full scale testing. In parallel, we will bring along the development of a wave prediction system that is required to enable effective control and test it at full scale. The purposes of this report are to: 1. Plan and document the 1/25th scale device testing at the wave-tank facility; 2. Document the test article, setup and methodology, sensor and instrumentation, mooring, electronics, wiring, and data flow and quality assurance; 3. Communicate the testing results between the associated members; 4. Facilitate reviews that will help to ensure all aspects (risk, safety, testing procedures, etc.); 5. Provide a systematic guide to setting up, executing and decommissioning the experiment.

16 TIDAL AND WAVE POWER↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Coupling laser physics to radiation-hydrodynamics

In order to accurately model implosion hydrodynamics in a radiation-hydrodynamics code, it is essential to include accurate accounting for energy deposition physics. In inertial confinement fusion (ICF), where capsules are driven by lasers or laser-driven x-rays, energy deposition profiles and energy transport have a strong impact on the development and evolution of capsule dynamics and hydrodynamic instabilities. Nevertheless, accurately modeling laser beam propagation in radiation-hydrodynamics codes presents unique challenges associated with disparate resolution requirements, the potential to seed spurious noise in highly unstable systems, and computational expense. We discuss a new method for coupling laser ray-tracing physics to a radiation hydrodynamics code, developed in the process of implementing the Mazinisin laser ray-trace into the xRAGE radiation hydrodynamics code. In contrast to previous approaches, in which laser ray-tracing is performed on the radiation-hydrodynamics mesh, our method involves a mesh generation and evolution strategy that addresses the unique requirements of the laser ray-trace in a separate mesh, enabling performance enhancements and strategies to reduce noise seeded by the discretization of beams into computational rays. In addition, we have employed several methods to ensure that spurious mesh imprinting is minimized. These involved optimizing the laser and radiation-hydrodynamics meshes as well as interpolation between them and requires the use of an exact initialization method for the radiation-hydrodynamics mesh. Furthermore, these techniques have enabled efficient computation of laser-driven implosions and other experiments with minimal introduction of spurious noise.

47 OTHER INSTRUMENTATION↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

TropiRoot 1.0: Database of tropical root characteristics across environments

Tropical ecosystems contain the world's largest biodiversity of vascular plants. Yet, our understanding of tropical functional diversity and its contribution to global diversity patterns is constrained by data availability. This discrepancy underscores an urgent need to bridge data gaps by incorporating comprehensive tropical root data into global datasets. Here, we provide a database of tropical root characteristics. This new database, TropiRoot 1.0, will be instrumental in evaluating an array of hypotheses pertaining to root functional ecology and plant biogeography, both within the tropics and relative to other global biomes. The data compilation was conducted by the TropiRoot Initiative, in partnership with the Fine-Root Ecology Database (FRED) and the Global Root Trait (GRooT) database, Colorado State University (CSU) and the Smithsonian Tropical Research Institute (STRI). Literature search and data extraction were conducted between 2020 and 2024. Literature was identified using Web of Science, Scopus, and complemented using the expert knowledge of members of TropiRoot. To provide broad environmental and geographical distributions, literature searches included root characteristics (traits) across global change drivers, natural gradients, and from different continents. We adopted FRED standardized data columns and streamlined the format to enhance accessibility for data extraction across various user groups. This optimized framework resulted in a smaller, yet comprehensive datasheet. To make the database compatible with other global root trait initiatives, column identification was standardized following the codes provided by FRED. These efforts culminated in data extracted from 104 new sources, resulting in more than 8000 rows of data (either species or community data). Most of the data in TropiRoot 1.0 include root characteristics such as root biomass, morphology, root dynamics, mass fraction, architecture, anatomy, physiology, and root chemistry. This initiative represents a 30% increase in the currently available data for tropical roots in FRED. TropiRoot 1.0 contains root characteristics from 25 different countries, where seven are located in Asia, six in South America, five in Central America and the Caribbean, four in Africa, two in North America, and 1 in Oceania. Due to the volume of data, when ancillary data were available, including soil data, these data were either extracted and included in the database or its availability was recorded in an additional column. Multiple contributors checked the entries for outliers during the collation process to ensure data quality. For text-based observations, we examined all cells to ensure that their content relates to their specific categories. For numerical observations, we ordered each numerical value from least to greatest and plotted the values, checking apparent outliers against the data in their respective sources and correcting or removing incorrect or impossible values. Some data (soil and aboveground) have different columns for the same variable presented in different units, including originally published units, but root characteristics data had units converted to match those reported in FRED. By filling a gap from global databases, TropiRoot 1.0 expands our knowledge of otherwise so far underrepresented regions and our ability to assess global trends. This advancement can be used to improve tropical forest representation in vegetation models. The data are freely available and should be cited when used.

FRED↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated tabletop exfoliation and identification of monolayer graphene flakes

Over the past two decades, graphene has been intensively studied because of its remarkable mechanical, optical, and electronic properties. Initial studies were enabled by manual “Scotch Tape” exfoliation; nearly two decades later, this method is still widely used to obtain chemically pristine flakes of graphene and other 2D van der Waals materials. Unfortunately, the yield of large, pristine flakes with uniform thickness is inconsistent. Thus, significant time and effort are required to exfoliate and locate flakes suitable for fabricating multilayer van der Waals heterostructures. Here, we describe a relatively affordable tabletop device (the “eXfoliator”) that can reproducibly control key parameters and largely automate the exfoliation process. In a typical exfoliation run, the eXfoliator produces 3 or more large (≥ 400 μm 2 ) high-quality graphene monolayer flakes, allowing new users to produce such flakes at a rate comparable to manual exfoliation by an experienced user. Furthermore, we use an automated mapping system and a computer vision algorithm to locate candidate flakes. Our results provide a starting point for future research efforts to identify more precisely which parameters matter for the success of exfoliation and to optimize them.

47 OTHER INSTRUMENTATION↗

Large-area low-noise flexible organic photodiodes for detecting faint visible light

Silicon photodiodes are the foundation of light-detection technology; yet their rigid structure and limited area scaling at low cost hamper their use in several emerging applications. A detailed methodology for the characterization of organic photodiodes based on polymeric bulk heterojunctions reveals the influence that charge-collecting electrodes have on the electronic noise at low frequency. The performance of optimized organic photodiodes is found to rival that of low-noise silicon photodiodes in all metrics within the visible spectral range, except response time, which is still video-rate compatible. Solution-processed organic photodiodes offer several design opportunities exemplified in a biometric monitoring application that uses ring-shaped, large-area, flexible, organic photodiodes with silicon-level performance.

47 OTHER INSTRUMENTATION↗

Machine-Learned Manifold-Based Models for Large Eddy Simulation of Turbulent Combustion

Reduced-order manifold combustion models are commonly used to lower the cost of reacting Large Eddy Simulations (LES) and may be derived either from physical principles as in flamelet models or from data-driven methods like Principal Component Analysis (PCA). In either case, neural networks are increasingly used as part of these models to provide a nonlinear mapping between a small set of pre-defined variables that parameterize the manifold and outputs of interest, such as reaction rates. In this work, we propose a new manifold-based modeling approach that combines the definition of the manifold-parameterizing variables (linear combinations of species), the nonlinear mapping to the outputs, and closure of filtered quantities for LES into the structure of a single neural network. This allows the process used to train the neural network to simultaneously optimize both the functional form of the model and the identities of the inputs to the model. The new approach can flexibly incorporate thermochemical data from any combustion system; if trained on data from 1D flames it can be interpreted as an optimized flamelet model, but it can also be used to learn models from data from more complex configurations. This work presents a priori evaluations of the new approach in both contexts. Evaluation using data from 1D premixed flames demonstrates the physical interpretability of the manifold variables generated by the new approach. Evaluation using data from direct numerical simulations of turbulent flames shows improved predictions relative to either flamelet or PCA-based models in a more complex configuration.

47 OTHER INSTRUMENTATION↗

Development of a Multi Sensor Data Science System for Monitoring a Solvent Extraction Process

Idaho National Laboratory is designing and constructing a solvent extraction test bed, Beartooth, as part of a nuclear fuel cycle stewardship initiative. The test bed will provide facilities and equipment for testing novel extraction processes and give early career scientists opportunities to gain skills in performing separations chemistry. The test bed is being uniquely designed to enable machine learning capabilities for the characterization of chemical process operations. One of the intentions of incorporating machine learning methods is to provide process operators with enhanced situational awareness for the optimization of separations techniques and possible detection of a diversion event. As a result, the objective of this Laboratory Directed Research and Development project is to develop a multi-sensor data collections system and implement machine learning techniques on signals from an existing centrifugal contactor cascade to identify equipment usage and process events. This presentation will provide an overview of sensors used and experiments conducted to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

rmc-discord : reverse Monte Carlo refinement of diffuse scattering and correlated disorder from single crystals

A user-friendly program has been developed to analyze diffuse scattering from single crystals with the reverse Monte Carlo method. The approach allows for refinement of correlated disorder from atomistic supercells with magnetic or structural (occupational and/or displacive) disorder. The program is written in Python and optimized for performance and efficiency. Refinements of two user cases obtained with legacy neutron-scattering data demonstrate the effectiveness of the approach and the developed program. It is shown with bixbyite, a naturally occurring magnetic mineral, that the calculated three-dimensional spin-pair correlations are resolved with finer real-space resolution compared with the pair distribution function calculated directly from the reciprocal-space pattern. With the triangular lattice Ba 3 Co 2 O 6 (CO 3 ) 0.7 , refinements of occupational and displacive disorder are combined to extract the one-dimensional intra-chain correlations of carbonate molecules that move toward neighboring vacant sites to accommodate strain induced by electrostatic interactions. The program is packaged with a graphical user interface and extensible to serve the needs of single-crystal diffractometer instruments that collect diffuse-scattering data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

srlife: A Fast Tool for High Temperature Receiver Design and Analysis

This report describes a tool for estimating the structural service life of tubular, panel solar receivers operating at high temperatures. A complete version of the tool is available as open source software at https://github.com/Argonne-National-Laboratory/srlife and can be installed through the PyPi (https://pypi.org) package manager. Given the basic receiver geometry and the thermal loads on the receiver, the tool provides 1D, 2D, or 3D thermal and structural (single tube and simplified system) analysis and creep-fatigue service life prediction for six metallic alloys – 316H, 800H, Alloy 617, Alloy 740H, and Alloy 230. With the exception of Alloy 230 where the material data is preliminary, the software included a detailed set of models for the materials, well-supported by high temperature experimental test data. The tool is designed for easy integration with a software stack, including solar field and thermohydraulic simulations, for optimizing receiver designs to meet service life and economic targets. The report describes several heuristics that can be applied in srlife to reduce the analysis time by several orders of magnitude but with fairly accurate life estimation when compared with full analysis. The report provides several examples demonstrating the utility of srlife in receiver design. Finally, the report discusses high temperature tests on Alloy 282, collected as part of this project, used to develop and support the material model for that alloy.

47 OTHER INSTRUMENTATION↗